Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC | ₹48.0 L Quoted ₹49.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹50.4 L+₹59,594.55 (1.20%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹50.4 L+₹59,594.55 (1.20%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹51.6 L+₹1.8 L (3.70%)Rejected-Finance | ₹51.6 L+₹1.8 L (3.70%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹57.6 L+₹7.8 L (15.7%)Rejected-Finance | ₹57.6 L+₹7.8 L (15.7%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹57.8 L+₹8.0 L (16.0%)Rejected-Finance DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | ₹57.8 L+₹8.0 L (16.0%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
13 Nov 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
REPAIR AND MAINTENANCE OF ROADWAY LIGHTING SYSTEM, DEHUMIDIFER,FIRE FIGHTING SYSTEM, INCINERATOR, FIRE DETECTION SYSTEM AND OTHER CONNECTED WORKS UNDER AGE E/M-I AT GE MINNIE BAY
2023_MES_623534_1
8308/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹95,000
Yes
19 Dec 2023
16 Oct 2023
15 Nov 2023
17 Oct 2023
13 Nov 2023
31 Oct 2023
Amount
Taking down defective street/security light / flood light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The cost for Items like LED lamp, electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items as "Supply only" here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The cost for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply only for carrying out repairs under item No.1 above with Electronic driver with THD less than 10%, suitable for 90 to 120 W LED light complete all as specified and directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.1 above with Electronic driver with THD less than 10%, suitable for 70 to 80 W LED light fitting complete all as specified and directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.1 above with Electronic driver with THD less than 10%, suitable for 30 to 60 W LED light fitting complete all as specified and directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.1 above with Surge protection device of capacity 10 KV suitable for LED light fitting complete all as specified and directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.1 above with Lamp Holder suitable for 40 watt LED complete all as specified and directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.1 above with LED Lamp 40 watt complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MCB 40 Amps, TP, 415 volt, breaking capacity 10 KA, ISI marked complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair for aluminium cable lugs for fixing of armoured cables in panels for the following sizes of cables complete all as specified and directed :-
Taking down of old UG Cable of any size/core and any type complete from trenches/cable duct/on wall/roof carefully, identifying for faults, dismantling unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Suppy, laying and testing XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: The cost of material and labour for earth work,DWC pipe,straight through joints if required will be measured and paid separately.The quoted rate shall deemed to include cost of necessary cable lugs, Cable Gland and necessary insulation taping etc.
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
Supply & Laying in repair of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40mm and inner dia 32mm polythylene including coupler & Bend with smoooth internal and corrugated external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge.
S&F in repair GI pipe of light grade ISI marked 40 mm dia all fitting fixture for fixing with wall and road crossing etc complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5m wide and not exc 1.5m in depth for foundation, pipe, laying of cable etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out complete all as specified and as directed by Engineer-in-Charge
All as per item No 14.00 above but exc 1.5 m or part there of in depth beyond 1.5m depth complete all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
S & F in repair for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 25 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
Relaying/ Rerouting old serviceable UG cable of size 10 to 25 Sqmm any core retrieved under this work in trench/pipe/DWC pipes /on wall /cable duct with necessary saddles/clamps of suitable size complete all as directed. Note: Earth work, replacement of DWC pipe/GI pipe will be measured and paid separately.
S&F as in repair loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm GI clamp, including suitable gland and lugs for connecting cable including dismantling old one complete all as specified and as directed by Engineer-in-Charge
Material and labour for painting to Steel tubular pole 9 m long with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal and lettering the pole details with adhesive sticker of dia 125 mm with white letters (indicating pole No/location code) on blue/black ground etc complete all as specified and as directed by Engineer-in-Charge
M&L for preparation of old painted surfaces of 9 m long RCC poles incl removing oily/greasy spots and applying one coat of synthetic enamel paint of black and yellow in alternate strips of 30 cm width upto 1.0 mtr height including applying a coat of white wash on pole, pole coping and lettering the pole details with adhesive sticker of dia 125 mm with white letters (indicating pole No/location code) on blue/ black background complete all as specified and as directed by Engineer-in-Charge
Material and labour for painting to coping of poles after making good the surface with Plain Cement Concrete 1:3:6 C2 using 40mm stone aggregate, preparation of surfaces and applying 02 coats of synthetic enamel paint over a coat of primer, the colour of paint shall be black/yellow or blue/white in zebra pattern complete all as specified and as directed by Engineer-in-Charge Note: PCC for making good the coping shall be measured and paid seperately under relevant item.
Material and labour for fixing in repair radium reflective, water proof adhesive sticker of width not less than 100 mm wrapped around the street light pole of approved colour complete all as specified and as directed by Engineer-in-Charge.
Dismantling old RCC / rusted poles including PCC and supply & erect minimum 7 mtr height above GL / foundation made out of Hot dip Galvanized single section octogonal pole with foundation base place of size 250x250x16 mm, foundation bolts 04 Nos of size m24 x 700/750 mm,with signle type arm bracket 1500 mm long, the pole shaft shall be tapered with single longitudinal welding and door opening for cable with 01 No MCB SP 6 Amp and 32 Amp connector and 03 run of 1.5 sqmm PVC wire for connecting street light fitting from MB complete all as specified and as directed by Engineer-in -charge. Note : Earth work, cement concrete in foundation, coping etc will be measured and paid seperately under relevant item.
M&L for Plain cement concrete Nominal mix in foundations filling and mass concrete of B1 grade with using 20 mm aggregate (1:2:4) complete all as specified and as directed by Engineer-in-Charge
M&L for Plain cement concrete 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete all as specified and as directed by Engineer-in-Charge
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work complete all as specified and as directed by Engineer-in-Charge. Note: The cost of dismantling of existing broken pole coping shall deemed to be included in this quoted rate.
S&F as in repair PVC copper cable insulated shealthed of size 1.5sqmm x 3 core complete all as specified and as directed by Engineer in charge.
Supply and laying as in repair on wall of CPVC pipes outer diameter 20mm SDR 13.5 pipes & plain CPVC SDR 11 fittings complete all as specified and as directed by Engineer-in-Charge
Supply and fix as in repair GI bracket for street lights made out of light grade GI pipe 40mm dia, not less than 1.2m long bend to shape as directed, fixed on poles with two Nos GI clamp of size 25 x 3mm flat iron suitable for steel tubular pole including suitable GI flat nuts and bolts washers complete all as specified and as directed by Engineer-in -charge.
M&L for GI bracket for street light fitting made out of 25 mm bore pipe ISI marked light grade GI tube bent to shape required,not less than 1.20m long, fixed with and including MS flat iron clamps made out of 25x3 mm GI flat, bolts, nuts, washers etc complete including dismantling old defective one all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of clamp made out of MS flat 40x6 mm including applying red oxide primer and two coats of synthetic enamel paint all per existing colour for steel tubular poles all as specified and directed by Engineer-in-charge.
Dismantling LED light fitting of capacity 90 to120watts ,strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and as directed by Engineer-in-Charge Note : The rate quoted is not inclusive of cost of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items all as specified and as directed by Engineer-in -charge.
Dismantling LED light fitting of capacity 70 to 80watts ,strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and as directed by Engineer-in-Charge Note : The rate quoted is not inclusive of cost of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items all as specified and as directed by Engineer-in -charge.
Dismantling LED light fitting of capacity 40 to 60watt ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and as directed by Engineer-in-Charge Note : The rate quoted is not inclusive of cost of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items all as specified and as directed by Engineer-in -charge.
Supply & fixing in replacement of LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 90 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08 SPD of capacity 10 KV etc ccomplete all as specified and as directed by Engineer-in-Charge Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule-A item.
Supply & fixing in replacement of LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 8640 lumens suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 72 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, SPD of capacity 10 KV etc complete all as specified and as directed by Engineer-in-Charge Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule-A item.
Supply & fixing in replacement of LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 7200 lumens suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 60 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, SPD of capacity 10 KV etc ccomplete all as specified and as directed by Engineer-in-Charge Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule-A item.
Supply & fixing in replacement of LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5400 lumens and suitable wattage for system efficiency not less than 120 lumens/Watt, having secondary optics, Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed by Engineer-in-Charge. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule item.
Supply & fixing in replacement of LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 3000 lumens and suitable wattage for system efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 25 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed by Engineer-in-Charge. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F in replacement energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long LED 25 W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50m, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth lead and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.
S&F MCB SP 6 to 40 Amps, 240 volts 50 Hz AC supply,10 KA C series complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 50 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Supply & fixing in replacement LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 18000 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 150 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply & fixing in replaceement LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 14400 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optic, minimum wattage 120 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply & fixing in replacement of LED bay light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame, (with total lumen output not less than 9600 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 80 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix/Luker .
Supply & fixing in replacement 1W solar LED bollard light fitting housed in die cast aluminium body, having high efficiency poly crystalline solar module, inbuilt maintenance free lithium battery with backup for 2 days, CCT 5700 K, IP 65 protection etc complete and testing on completion all as specified and as directed.
Supply & fixing as in repair 1W solar LED gate light fitting housed in die cast aluminium body, having high efficiency poly crystalline solar module, inbuilt maintenance free lithium battery with backup for 2 days, CCT 5700 K, IP 65 protection etc complete and testing on completion all as specified and as directed.
Supply & fixing as in repair 4watt water proof, weather proof sensor based illumination control solar LED wall light fitting made up of plastic having high efficiency poly crystalline solar module, inbuilt maintenance free lithium battery with backup for 3 days, CCT 5700 K, IP 65 protection, charging time 8-9 hrs etc complete and testing on completion all as specified and as directed.
Supply and fixing as in repair of Service wire Aluminium Conductor Weather Proof 10 Sqmm 2 core complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair Digital Timer control panel ,contactor pre wired Distribution Board complete time lite 40A 3 Pole 415 V complete as specifed and directed by Engineer-in -charge. Make : Indo Asian cat pt No TL040DB0
M&L for surface excavation n.exc. (not exceeding) 30 cm deep and averaging 15 cm deep and getting out soft / loose soil including removing the materials to a distance not. exc 60m complete all as specified and directed by Engineer-in -charge.
M&L for wiring of unserviciable Timer panel box complete and replacement of existing size of copper wire and copper lugs and testing complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair contactors of capacity 40amps 3 Pole 415 V with 2NO+2NC complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair NO/NC auxillary contacts of capacity 40A of 415 V complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair digital timer switch, current capacity 16A, with 1 changeover complete all as specified and as directed by Engineer-in -charge.
M&L for Inspection, maintenance and servicing of 60 HP Diesel Engine pump as per OEM manual for 'B' check once in a 03 month or 250 hrs whichever is earlier of the engine for smooth functioning and carrying out the complete checks as per the manufacturers instructions all as specified and directed by the Engineer-in-Charge:- (a) Replace the lubricating oil. (b) Replace lubricating oil filter element. (c) Replace lubricating oil by pass filter element. (d) Replace the fuel filter element. (e) Check engine coolent. (f) Check the crank case breather. (g) Check turbo charger (for turbo fitted engine). (h) Draining out unserviceable engine oil from sump. (i) Checking & adjusting fan belts. Note. Engine oil & radiator coolant are included in the rate quoted.
Dismantling the pump of 60 HP - 40 HP capacity, isolating suction / delivery line connections, checking the worn out parts like impeller, shaft, stuffing box, shaft sleeve using Micrometer and transporting to workshop for repairs, check for condition of bearings, removing scales from impeller and pump housing, building the worn out metal of transmission shaft to required level, machining to the required size on lathe machine, grinding and finishing to match the sleeve, and fixing into the housing, re-assembling, transport back to the installation, installing in position, check for alignment with dial gauge, inserting shims where necessary, refixing with coupling, tightening with torque wrench to required level, re-connecting the flanged pipe connections of suction/ delivery, greasing for bearings including replacement of rubber insertion etc complete all as specified and directed by the Engineer-in-Charge. Note :- Spares will be measured and paid separately under relevant schedule.
All as per item No 61.00 above but of 12.5 HP / 10 HP all as specified and directed by the Engineer-in-Charge
Supply only for carrying out repairs under item No. 61.00 above with the following items for incorporating of pumpset repair work for the of capacity 60 HP - 40 HP :-
Shaft bushes with check nuts (stainless steel) for above pumpset.
Ball bearings suitable for above pump.
Metal Coupling for above pumpset.
Gland packing end cover (Stainless steel of suitable grade) as per existing size
Supply only for carrying out repairs under item No. 61.00 above with the following items for incorporating of pumpset repair work for the capacity 12.5 HP / 10 HP :-
Shaft bushes with check nuts (stainless steel) for above pumpset.
Ball bearings suitable for above pump. Make : NBC / SKF.
Metal Coupling for above pumpset.
Gland packing end cover (Stainless steel of suitable grade) as per existing size
M & L for dismantling the defective induction motor of 60 HP - 40 HP capacity/make/class of insulation from foundation bed, disconnecting all electric supply connections, duly coupled with pump/compressor, trasnporting to workshop removing burnt out widing from stator/rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE /NDE bearings, insulation materials, varnishing , heating, greasing of bearings etc complete, re-assembling, testing and commissioning of following capacity motors all as directed. Note : Terminal block, Bearings of motor if required will be measured & paid separately under relevant schedule items.
All as per item No 64.00 above but of 12.5 HP / 10 HP
Dismantling of motor of 60 HP - 40 HP capacity pumpset from installed position after disconnecting the coupling and electric connections and transporting the motor to the work shop, strip opening of the motor complete incl dismanlting stator, rotor assembly and cleaning the complete assemblies by taking out perished glass sleeve of connecting leads from common termination to terminal block,and washing with carbon tetra chloride, decarbonising and cleaning the rotor with CTC solution.Replacing the glass sleeve of connecting leads from common termination to terminal block, binding the loose coils with binding cloth, varnishing the coils complete and applyng bectol on the excitor coils, stator coils and heating complete, reassembling the unit and testing with megger for insualtion value and re-assembling, aligning with pump, re-inserting shims where necessary, refixing with coupling, tightening with torque wrench to required level, re-connecting the electric cable etc and check for drawing current testing, commissioning etc all as directed by Engineer-in-Charge.
All as per item No 66.00 above but of 12.5 HP / 10 HP
M&L for replacement of rubber bush coupling for 60 HP to 40 HP capacities of pumpsets complete all as directed.
All as per item No 69.00 above but of 12.5 HP / 10 HP
Supply only following bearings required during winding of motors all as directed
DE/NDE bearings suitable for 40 to 60 HP motor
DE/NDE bearings suitable for 12.5 / 10 HP motor.
Supply only terminal block complete with hardware of following capacity motors
(a) 60 HP to 40 HP
(b) 12.5 HP / 10 HP
Supply and fixing in replacement of pressure gauge 0-21 kg/cm² ,4" dia complete with necessary fittings incl dismantling old one all as directed.
Supply and fixing as in repair fully automatic starter delta startor 3 Phase 415 Volt 50 HZ suitable for 60 HP inducdtion motors for the following capacity.
Supply and fixing as in repair DOL starter three phase, 415 Volt with over load relay suitable for 10/12.5 HP capacity with sheet steel enclosure complete all as directed.
Material and labour for preparation/cleaning of outer surface by scrapping with emery paper or other means and painting of fire fighting pump motor of following sizes with two coat of synthetic enamel paint over a coat of red colour all as specified and as directed.
M& L for preparation to external old steel surface of fire fighting pipe line/hose box/door/panel board and connected accessories of various sizes by scraping and applying a coat of synthetic enamal paint complete all as specified and as directed. Note :- (i) Colour of paint will be decided by Engr-in-Charge. (ii) Scaffolding and other safety precution equipment will be arranged by the contractor for the pipes which are upto G+3 floor height and cost for the same shall be deemed to be included in the quoted rate.(iii) Contractor shall made good all disturbed surfaces and quoted rate deemed to be inclusive for the same.
Taking down old unserviceable MS pipe of any class and any size complete all as specified and as directed.
Supply and lay as in repair of MS pipe ERW Heavy (IS1239) errect, jointing complete of 150 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc and taking down old unserviceable MS pipe complete all as specified and as directed.
All as per item srl No 80.00 above but of 100 mm dia complete all as specified and as directed.
All as per item srl No 80.00 here-in-before but of 80 mm dia complete all as specified and as directed.
All as per item srl No 80.00 here-in-before but of 50 mm dia complete all as specified and as directed.
All as per item srl No 80.00 here-in-before but of 25 mm dia complete all as specified and as directed. Note : for item Nos.80 to 84 (i) The excavation earth work measured and paid seperately under relevant item. (ii) Flanges & gaskets at both ends of each pipe shall be included in the quoted rate. (iii) The quoted rates also include for cutting of existing pipe for insertion of fittings / new branch pipe. (iv) Painting to the new pipe including applying primer shall be measured and paid seperately.
M& L for preparation to external new steel surface of fire fighting pipe line/hose box/door/panel board and connected accessories of various sizes by scraping and applying two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed. Note :- (i) Colour of paint will be decided by Engr-in-Charge. (ii) Scaffolding and other safety precution equipment will be arranged by the contractor for the pipes which are upto G+3 floor height and cost for the same shall be deemed to be included in the quoted rate.(iii) Contractor shall made good all disturbed surfaces and quoted rate deemed to be inclusive for the same.
S&F in replacement Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Addressable manual call point resettable type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Fire Alarm Sounder cum strobe shall have audibility level not less than 85 DB measured at 1 Mtr, strobe shall have not less than 75 cd flashing at 1 Hz for visual indication with control module, operating voltage 24 volts DC the sounder cum strobe shall be integrated with control modules of existinf FACP complete all as specified and as directed by Engineer in Charge.
Cleaning of semi underground static water tank of capacity 1.65 lakh ltrs by the following method :- (a) The inner surface of the walls of the tank shall be cleaned with wire brush after emptying the water in the tank to adjacent tank. (b) After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed. (c) After removing the sludge from tank the tank shall be cleaned with anti bacterial agents. (d) Applying water proofing compound to arrest leakages and seal the cracks on walls. (e) After complete treatment, writing of "Tank capacity" 'Date of cleaning and due date of cleaning' on wall including applying two coats of white washing to external surfaces complete all as specified and as directed
All as per item No 89.00 above here-in-before but of semi underground sump capacity 60000 Liters complete all as directed.
S&F in repair butterfly valve with CI body of size 100 mm dia with suitable gasket, nut & bolts including necessary welding works as required complete all as specified and as directed
S&F in repair butterfly valve with CI body of size 150 mm dia with suitable gaskit, nut & bolts including necessary welding works as required complete all as specified and as directed
S&F in repair butterfly valve with CI body of size 80 mm dia with suitable gaskit, nut & bolts including necessary welding works as required complete all as specified and as directed
Supply and fixing in repair cast Iron Non return valve, short body type, flanged ends heavy duty as per IS 5312, PN 1.6 of size 100 mm dia including 6mm thick rubber insertion ring complete all as specified and as directed.
M & L in repair for yard hydrant post 80 mm dia MS of flange type complete all as specified and as directed.
M & L for servicing of 24 No fire hydrant posts for arresting any leakage, replacing damaged O rings, lock plugs, end caps with chain complete all as specified and as directed by Engineer in Charge. Note: (i) lock plugs shall be measured and paid seperately under relevant item as supply only.
Supply only for carrying out repairs under item No. 97.00 above with lock plugs for fire hydrant posts complete
Supply and fixing in repair fire hydrant valve, single headed including required washer and fittings complete all as specified and directed.
Supply and fix in repair C P Hose of 15 m length complete all as specified and as directed.
Supply and fix in repair branch pipe gun metal 63 mm inlet made threaded outlet 15mm bore nozzle short complete all as specified and as directed.
M & L in repair for hose box of any description and providing new hose box made of 18 gauge MS sheet 800x600x250mm with double door with 4mm thick glass and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard including taking down unserviceable hose box complete all as specified and as directed.
Supply and fix in repair Hose reel Drum including 30 m long and 20 mm dia high pressure hose reel and taking down unserviceable hose reel drum complete all as specified and as directed.
Supply and fix as in repair of transparent acrylic sheet thickness of minimum 3 mm for hose box complete all as specified and as directed.
M & L for Cutting the tarmac / hard standings and excavating in trenches across the road for laying pipe / LT UG cable / GI pipe / DWC pipe including making good the excavated portion by means of PCC 1:3:6, type C2 matching with the surroundings all as directed.
M&L for precast cement concrete solid block masonry exc 10cm in width type C1, 1:3:6 (using 20mm stone aggregate ) set in CM (1:6) for value pit chember etc including demolition of old masonry complete all as directed.
Carrying out repair, maintenanace, servicing and attending breakdown of oil fired incinerator of Make HATT, including inspecting all parts, control circuit wiring and control circuit boards / mother board for general repairs / servicing / over hauling as per OEM instructions for ensuring smooth and trouble free operation of equipment to the entire satisfaction of user / department all as specified and as directed by Engineer in Charge. (a) The rep of OEM shall visit the installation site for periodic preventive maintenance check up of the Fire incinerator system for every 3 months other than breakdown job . During this the system shall be cleaned and general performance will be checked including inspection of all spare parts such as fuel injection pump, primary burner system, secondary burner system, operation of hydraulic doors, ID fan, FD fan, entire control circuit wiring, PCB board / control circuit board and all other connected items for functioning of the fire incinerator and repairing the same if found defective and testing & commissioning after rectifying defect complete all as specified and as directed. Note: (i) All spare parts such as nozzle assembly, photo cell light detector, fuel pump, solenoid switch,ignition electrode, thermocouple, control circuit borad / mother board / PCB, burners, hydraulic oil shall be measured and paid seperately. (ii) The quoted rate inclusive of cleaning of Fire incinerator and connected system as per OEM instructions and control wiring. (iii) The charges for fixing, commissioning, testing of new spares including diamantling old units is included in the quoted rate.(Each job per incinerator is for 06 months and breakdown call will be measured and paid seperately). :
Supply only following spares for carrying out repairs / maintenance / servicing
Supply only Nozzle assembly
Supply only Photocell Light detector
Supply only control circuit board / mother board
Supply only hydraulic oil
Supply only Fuel pump BFP 41L3
Supply only Solenoid switch
Supply only Ignition electrode
Supply only Thermo Couple .
Material & Labour in repair of inside fire chamber with fire bricks and zypsm of side wall and roof of the primary and secondary chamber including testing and commissioning complete as as specified and directed.
Material and labour for cleaning of chimeny of incinerator from chamber to upto 10 m height and removing all dirt, particles from inside and refixing with gland, nuts and bolts and cleaning of mild steel water tank, removing all particles from tank, replacement of GI Pipe connected from chimeny to water pump including valves and arresting any leakage in water collectin tank and other accessories complete all as specified and as directed.
M&L for carrying out inspection, checking, repair, maintenance and attending breakdowns for 2 Nos. IGBT based UPS of capacity 40 KVA each of Microtek make at INHS Dhanvantari comprising of the following outlined services:- (Set of 2 Nos UPS will measured as one Job) (a) The Contractors technical team shall visit the installation site for periodic preventive maintenance check up of the UPS system and the batteries for every 3 months other than breakdown job . During this the system shall be cleaned and general performance will be checked including inspection of all spare parts such as iGBT, Drive cards, relay cards, AC capcitors, inverter cooling fan, ceramic fuses and including replacing the defective spares if any complete, re-assembling, calibration of UPS complete and testing & commissioning complete all as specified and as directed.(b) DC back up source will be maintained by applying white petrolium jelly, checking/ servicing of batteries etc as applicable.(c) Apart from the periodic preventive maintenance visits, all break down calls on the systems covered under AMC shall be attended.(d) Cost of all the spares except Charger card, Power card, Driver card, AC/DC capacitors, IGBT, replacement of Batteries to put the UPS in working condition shall be born by the contractor during the AMC period.(e) Response time during normal working hours shall be 4 Hrs from the time of receipt of complaint and the resolution time shall bemaximum 48 hrs, based on the nature of complaint and replacement of components and boards.(f) Major Spares such as Charger card, Power card, Driver card, AC/DC capacitors, IGBT, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.(g) In addition to the above the contractor shall attend and rectify all types of defects arised during the contract period, to keep the UPS system in operational condition.
M&L for carrying out inspection, checking, repair, maintenance and attending breakdowns 6 Nos. IGBT based UPS of capacity 05 KVA each of Microtek make at INHS Dhanvantari comprising of the following outlined services (Set of 6 Nos UPS will measured as one Job):- (a) The Contractors technical team shall visit the installation site for periodic preventive maintenance check up of the UPS system and the batteries for every 3 months other than breakdown job . During this the system shall be cleaned and general performance will be checked including inspection of all spare parts such as iGBT, Drive cards, relay cards, AC capcitors, inverter cooling fan, ceramic fuses and including replacing the defective spares if any complete, re-assembling, calibration of UPS complete and testing & commissioning complete all as specified and as directed. (b) DC back up source will be maintained by applying white petrolium jelly, checking/ servicing of batteries etc as applicable. (c) Apart from the periodic preventive maintenance visits, all break down calls on the systems covered under AMC shall be attended. (d) Cost of all the spares except Charger card, Power card, Driver card, AC/DC capacitors, IGBT, replacement of Batteries to put the UPS in working condition shall be born by the contractor during the AMC period. (e) Response time during normal working hours shall be 4 Hrs from the time of receipt of complaint and the resolution time shall bemaximum 48 hrs, based on the nature of complaint and replacement of components and boards. (f) Major Spares such as Charger card, Power card, Driver card, AC/DC capacitors, IGBT, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.(g) In addition to the above the contractor shall attend and rectify all types of defects arised during the contract period, to keep the UPS system in operational condition.
Supply only the following spares for carrying out repairs to UPS of capacity 40 KVA of Make: Microtek :-
Charger Card
Power Card / Mother board
Capacitor
Supply only the following spares for carrying out repairs to UPS of capacity 5 KVA of Make: Microtek :-
Charger Card
Power Card / Mother board
Driver Card
Capacitor
12 V, 26 AH SMF Batteries
Carrying out repair, maintenanace and attending servicing / breakdown of following capacity chemical desiccant dehumidifiers, including strip opening of dehumidifier inspecting parts / spares for general repairs / servicing / over hauling as per the following scope of work given below for ensuring smooth and trouble free operation of equipment to the entire satisfaction of user / department all as specified and as directed by Engineer in Charge. :Scope of work: (i) Filters: Check for physical status of filters, cleaning the both process and reactivation air filters by racking out filters from dehumidifiers and clean both the filters with compressed air or wash with warm soap solution and refix both the filters in their location. If the filters are damaged replace the filters of OEM recommended make.(ii) Desiccant Rotor: Check the desiccant rotor for smooth operation, no sign of discoloration, pits, cracks due to dirt, dust or other foreign material. The desiccant rotor should be removed for cleaning from its position safely as per OEM instaructions. Cleaning the rotor by dry vaccum and dusting brush with attachment with soft bristle brush and vaccum both the surfaces of rotor or by applying moisture free compressed air of pressure rating less than 2 Kg/sqcm on one side at lease 250mm away from rotor surface and vaccum on other side, refix the rotor in its original position. The cleaning of desiccant rotor is upto full satisfaction of Engineer in charge and if the rotor replacement is inevetable due to poor performance of rotor the same should be replaced with new desiccant rotor of OEM make complete all as directed.(iii) Seals: Check the seals for any wear and tear and air leakge, the same should be replaced with high performing silicone seals complete all as directed.(iv) Reactivation air heater: Check the heater element complete all as directed.(v) Fan Motors: Check for any abnormal sound from the motors and clean both the process and reactive motors by removing from their original postion, remove the impeller and clean the fan impeller throughly and refix the same in original location.
.(vi) Bed drive unit: Disconnect the bed drive motor supply check for any wear and tear of bed drive timing belt and replace the same if damaged and care should be taken for to avoid revese rotation of motor while refixing.(vii) Electric circuit: Tighten all connections by applying proper torque . (viii) Attending complaints of Dehumidifier of following capacity, checking for control circuit and power circuit connections from MCB TPN / SPN plug socket control point to dehumidier, healthiness of process fan & react fan motor winding, functionality of the contactors, over load relay, differential pressure switch, delay timer, heater coil, thermostat, limit switches, illuminating switches, rotation of dessicant rotor / bed drive reduction unit, complete as per nature of complaint and rectify the defect by replacing concerned material / rewinding of fan motors complete to make the dehumidifier operational all as specified and as directed by Engineer in Charge. Note: (i) The quoted rate is inclusive of control wiring. (ii) Each complaint / servicing attended shall be measured as one job through job card and after completion the same shoud be signed by Engineer in Charge. (iii) All spare parts incorporated should be as per OEM recommendation only. (iv) Sapres like control wiring, nuts / bolts / washers etc, T&P for servicing are deemed to be included in the quoted rate. (v) Replacement of spares such as filters, desiccant rotor, bed drive unit, Bed drive timing belt limit switch, thermostat, seal group, heater coil, LED lamp, switches, contactors, relays, MCBs, rewinding of fan motor will be measured and paid separately under relevant items.
(vi) It is responsibility of contractor to engage required manpower as per requirement and take necessary measures to run the equipment in event of breakdown to the satisfaction of user and as directed by Engineer in Charge. Considering the sensitive nature of installation the contractor shall always be in a position to make alternate standby arrangement in case of break down. Contractor shall keep his spares ready in advance for carrying out repairs without any delay. Any break down shall be attended within 2 Hrs and defects shall be rectified within 24 Hrs of time otherwise a recovery of Rs 2000/Hr along with cost of perished storage products due to non-functional of equipment shall be attributed to contractor without any further claim. The cost for same is deemed to be included in scope of item. The labour charges for fixing, commissioning, testing of new spares including diamantling old units is included in the quoted rate.(Each job per each dehumidifier unit for 03 months and breakdown call will be measured and paid seperately).
Dehumidifier of capacity 600 cmh (FFB - 600)
Dehumidifier of capacity 300 cmh (FFB - 300)
Dehumidifier of capacity 170 cmh (FFB - 170)
Supply only following spares for carrying out repairs / maintenance / servicing of dehumidifier
Filter of size 280 x 160 x 25 mm for FFB 600 model.
Supply only filter of size 350 x 160 x 38 mm for FFB 600 model.
Supply only Desiccant rotor of OEM make for FFB 600 model.
Supply only seal group of OEM make for FFB 600 model.
Supply only bed drive timing belt of OEM make for FFB 600 model.
Supply only filter of size 215 x 160 x 25 mm for FFB 300 model.
Supply only filter of size 286 x 115 x 38 mm for FFB 300 model.
Supply only Desiccant rotor of OEM make for FFB 300 model.
Supply only seal group of OEM make for FFB 300 model.
Supply only bed drive timing belt of OEM make for FFB 170 model.
Supply only Desiccant rotor of OEM make for FFB 170 model.
Supply only seal group of OEM make for FFB 170 model.
Supply only bed drive timing belt of OEM make for FFB 170 model.
Supply only MCB TPN, 415 Volts, 32 Amps 10 KA complete
Supply only power contactor 3 phase, operated by 230 volts complete. Cat Part No. 10919
supply only Thermal overload relay complete Cat part No. 10968
Supply only differential pressure switch complete Cat part No. 11065
Supply only delay timer 0-10 (s/m/h) range Cat Part No. 11093
Supply only heater coil 2.4 KW,230 Volts AC tubular type complete Cat Part No. 11168
Supply only thermostat of range 50-300º C complete Cat Part No. 11089
Supply only limit switch SPDT Cat part No. 11067
Supply only illuminating switch Cat Part No. 11077
Supply only bed drive reduction unit with gear motor of capacity 0.34 HP, 230 volts complete. Cat part No. 10682
Rewinding of process / React fan motors of capacity 0.5 HP, 3 phase 415 volts complete
Supply only MCB SPN 230 Volts, 25/32 Amps 10 KA complete
Supply only heater coil 1.8 KW,230 Volts AC tubular type complete Cat Part No. 10711
Rewinding of process / React fan motors of capacity 0.125 HP, 1 phase, 220 volts complete
Supply and fix MCCB 3 Pole 125 A, 16 KA breaking capacity, thermal magnetic release including taking out old unserviceable MCCB complete all as specified and as directed.
Supply and fix MCCB 3 Pole 63 A, 16 KA breaking capacity, therma; magnetic release including taking out old unserviceable MCCB complete all as specified and as directed.
Supply and fix MCB TPN 40-63 A, 10 KA breaking capacity including taking out old unserviceable MCB complete all as specified and as directed.
Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 180 AH including terminal clamps, copper lead of suitable length including testing and commissioning all as directed by Engineer-in-Charge.
Material and labour for Servicing of 5 Ton capacity Manual operated crane all as per OEM recommendation, greasing, oiling, complete including replacement of minor spares, oil, lubricants, grease etc., complete including testing all as specified and as directed by Engr-in-Charge
A. R. ELECTRICALS
bansal construction
NAVJEEVAN ENTERPRISES
PTech Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .