| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹29.2 L+₹37,137 (1.29%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹30.1 L+₹1.3 L (4.44%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 4 | L4₹30.1 L+₹1.3 L (4.46%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 5 | L5₹30.2 L+₹1.4 L (4.98%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
21 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF WORN OUT ELECTRICAL WIRINGS EXISTING FITTINGS AND FIXTURES WITH MODULAR FITTINGS AND ALLIED WORKS IN CERTAIN SAILORS MARRIED ACCN IN RS COLABA AT NAVY NAGAR COLABA MUMBAI
2024_MES_669473_1
8396/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹92,000
Yes
3 Oct 2024
31 Aug 2024
23 Sept 2024
31 Aug 2024
21 Sept 2024
14 Sept 2024
31 Aug 2024 - 21 Sept 2024
Amount
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
Material and labour for point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling/floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin socket outlet, 5 Amps on the same board with other switches
One 3 pin socket outlet, 5 Amps, on the independent board
One bell point controlled by one push button
All as per item No 2.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F modular switch, 1 module, single pole one way 6 Amp confirming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp confirming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular socket 6A, 3 pin, 2 module confirming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6A, 3 pin, 2 module confirming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6/16A, 3 pin, 2 module confirming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed. Make : C&S/Bajaj/Havells/ Philips.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F in replacement with modular PVC Gang box of 12 module, ISI marked for mounting of modular switches and sockets including blank plate for blank module. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
All as per Item No- 18.00 above but of modular PVC Gang box, 8 module.
All as per Item No- 18.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 18.00 above but of modular PVC Gang box, 4 module.
All as per Item No- 18.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 18.00 above but of modular PVC Gang box, 1/2 module.
S&F modular white cover plate with frame, 12 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 4 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 1/2 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. Make of Light Fitting : Wipro/Crompton/Philips/Bajaj/Polycab
All as per Item No-30.00 above but Slim LED integrated batten of 10 Watt 2ft complete. Make of Light Fitting : Wipro/Crompton/Philips/Bajaj/Polycab
Taking out any type of bulkhead fitting/FTL and S&F in replacement 10W LED batten with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2 feet, polycarbonate extruted channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete with following specification. (i) housing-polycarbonate extrusion,diffuser- opal- polymer, LED type- MID power ,Light distribition- general Spread, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95, THD - <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection - IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of otion switches back to default operation, LED life- upto 30,000 Hrs.Surge Protection- not less than 1KV. Make:- Wipro, Philips, Bajaj, Jaguar
Taking out Old U/S and S&F MCB SPN, 63 Amp, 10 KA, 230 Volt.
Taking out old U/S and Supply and fixing of MCCB DB VTPN 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complele all as specified and directed.
Supply and fixing of MCCB 100A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu .
S & F in replacement with electric bell ding dong, AC, 230V single pole.
M&L for LT FPB, weather proof, vermin proof, double door made out of 3.3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Coper busbar strip of 600 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 50x50x5 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2. all as specified & Directed consisting of following :- (Note:- Before fabrication of panel, contractor has to take approval from accepting officer on drawing)
Incomer : (a) DPX³ 250 MCCB with Electronic Sg (LSIg) Protection Unit, 250A, 36KA, 4P - 01 Nos. Make : Legrand Cat ref : 420539 or equivalent in Siemens/Schneider/ABB
Outgoings :
(b) DPX³ 160, Thermal magnetic release , Ics=100% Icu MCCB 100A, 25kA, 4P - 2 Nos. Make : Legrand Cat ref : 420055 or equivalent in Siemens/Schneider /ABB
(c) DPX³ 160, Thermal magnetic release , Ics=100% Icu MCCB 63A, 25kA, 4P - 6 Nos. Make : Legrand Cat ref : 420053 or equivalent in Siemens/Schneider /ABB
(d) Digital Ammeter Make-HPL/L&T/AE - 01 Nos
(e) Digital Voltmeter Make-HPL/L&T/AE - 01 Nos
(f) Phase indicator lamp R,Y & B - Set of 3
(g) Coper Bus bar 600 Amps rated of suitable size - Set
Taking out old existing unarranged communications cable/conduits/casing caping/Lightening Protection cable from wall surfaces and keep a side and refixing the same after making good of wall surfaces under cable trunking/trays or using saddling complete all as specified and directed.
Supply and fixing of DLP PVC trunking system with all connected fittings for fixing on wall ceiling surfaces (end, joint of lid, joint of body, interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1 of under mentioned size and refixing/resaddeling of all dismantalled UG cables/submain inside the trunking and made connection as specified and directed : Make : Legrand/Honewell/Obo
PVC truncking 150X50MM
PVC truncking 80X50MM
Flexible cover 85MM width
Flexible cover 65MM width
Clip on partition
Base joint for tuncking
Joint for 85MM width cover
Joint for 65MM width cover
Flat angle for 150X50-DLP TRU
Flat angle for 80X50-DLP TRU
Internal angles adj 80-100 degree
External angles adj 60-120 degree
S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
shree arihant constrution (BID ID -3103861)
Shree Gajanan Enterprises (BID ID -3103996)
Panther Facilities (BID ID -3103680)
ASHOK ENTERPRISES (BID ID -3100903)
NOEL ENGINEERS (BID ID -3096291)
SHREE JAGDISH FURNITURE CO. (BID ID -3099592)
SHRI SAI ENTERPRISES (BID ID -3103422)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .