Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | L1 | Accepted-AOC AOC issued | |
| 2 | L2₹4.4 L+₹57,450 (15.2%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L2 | Rejected-Finance That the Bid is not L1 | |
| 3 | L3₹4.6 L+₹80,661 (21.3%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance That the Bid is not L1 |
| Sl No | Description | Qty | Unit | DECADON ENGINEERING L1 | M/s Singh Electrical Works L3 | M/S R. K. ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing E.I. work by Co's own tools & tackles and remove unnecessary,scrap items away from site by maintening normalcy as far as possible and deposit necessary materials to section office as per direction of EIC . | 1 | Item | 1,000 ₹1,000 Lowest | 2,500 ₹2,500 | 2,500 ₹2,500 |
| 1.10A. Distribution wiring:--- | ||||||
| 2.00Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Cable / Polycab / Havell's/Glostar) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] vide pg no E-15 item no. 5 | ||||||
| 2.10 | avg run 10 mtr | 20 | Pt | 800 ₹16,000 | 325 ₹6,500 Lowest | 920 ₹18,400 |
| 3.00Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Cable / Polycab / Havell's/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. vide pg no E-14 item no. 1a | ||||||
| 3.10 | 3 X 1.5 sqmm | 30 | RM | 55 ₹1,650 | 11 ₹330 Lowest | 90 ₹2,700 |
| 3.20 | 2 X 2.5 sqmm + 1 X 1.5 sqmm | 190 | RM | 58 ₹11,020 | 13 ₹2,470 Lowest | 95 ₹18,050 |
| 3.30 | 2 X 4 sqmm + 1 x 2.5 sqmm ( for AC) | 50 | Mtrs | 200 ₹10,000 | 16 ₹800 Lowest | 135 ₹6,750 |
| 4.00Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. (P/No., E-3. I/No. 6 (a) | ||||||
| 4.10 | 19 mm dia 3 mm thick polythene pipe without earth continuity wire | 35 | RM | 35 ₹1,225 | 15 ₹525 Lowest | 125 ₹4,375 |
Tender Value
Refer Docs
EMD Value
₹9,340
Closing Date
22 Jul 2025, 1:00 pmClosed
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Renovation work of administrative office along with SITC of new Air Conditioning system at College of Nursing, Medical College and Hospital Kolkata E.I. Work.
2025_WBPWD_876264_1
WBPWD/AE/KMCESD/NIQ-41/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,340
9 Jul 2026
9 Jul 2025
1 Nov 2025
15 Jul 2025
22 Jul 2025
15 Jul 2025
Amount
Dismantling the existing E.I. work by Co's own tools & tackles and remove unnecessary,scrap items away from site by maintening normalcy as far as possible and deposit necessary materials to section office as per direction of EIC .
A. Distribution wiring:---
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Cable / Polycab / Havell's/Glostar) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] vide pg no E-15 item no. 5
avg run 10 mtr
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Cable / Polycab / Havell's/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. vide pg no E-14 item no. 1a
3 X 1.5 sqmm
2 X 2.5 sqmm + 1 X 1.5 sqmm
2 X 4 sqmm + 1 x 2.5 sqmm ( for AC)
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. (P/No., E-3. I/No. 6 (a)
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- RR Cable / Polycab / Havell's/Glostar) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. vide pg no E-9 item no. 1
3 X 1.5 sqmm
2 X 2.5 sqmm + 1 X 1.5 sqmm
2 X 4 sqmm + 1 x 2.5 sqmm ( for AC)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. vide pg no F-5 item no. 9
B. Plug & Sockets:--- Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Cable / Polycab / Havell's/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick as per GS.(on board) vide pg no E-15 item no. 4
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S& F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as to GS.(Vide page no E 7 Item no 26 )
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor mk.) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. vide page no E-6 item no 22
S & F 240 V, 6 A plug socket (2 nos) with separate 6 A piano key type switch (2 nos) (Anchor) on sheet metal switch board embedded in wall incl. S & F 175 x 100 x 65 mm MS (16) SWG switch board and bakelite /perspex top cover of 3 mm thick by brass screws after making housing for switch by cutting bakelite /perspex cover and making necessary connection as required .
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. vide pg no E-17 item no. 5a
C: Supply of Light fittings:- Supply and Delivery 4' long Single LED tube fittings (Philips T.M.C 502 1 X T - LED 22W/Wipro WIO921208P/ Lighting Technology) complete with 1 no 18/20 Watt LED tube tube (PHILIPS - LEDTUBE 18W 2100 lm 865 T8 (ve) / Wipro LL13 - 181 - 65 SESL1 - G1 / Lighting Technology)
Supply and Delivery 4' long Twin LED tube fittings (Philips T.M.C 502 2 X T - LED 22W/Wipro WIO922208P/Lighting Technology) complete with 2 no 18/20 Watt LED tube tube (PHILIPS - LEDTUBE 18W 2100 lm 865 T8 (ve) / Wipro LL13 - 181 - 65 SESL1 - G1 / Lighting Technology)
D. Fixing of Light Fittings :--- Fixing only single/twin fluorescent light fittings suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp (125mmx125mm) as per G S Vide page no C-2, Item no 17
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length as per G S Vide page no C2 Item no 16
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.Vide page no C2 Item no 14(b)
E. Supply of fans :--- S & D 250 V 50 HZ, 85watt, 18" (450 mm) high flo ( air delivery-- 4500 CFM, RPM-- 1420) non-oscillating type metal body Wall Bracket fan with inbuilt regulator, double ball bearing, intergally cast LM6 impeller (Make -EPC)
S & D 230V, 80 watt,1420 RPM heavy duty exhaust fan (Make -- EPC/ USHA,S.Ph TURBO Heavy duty,1400RPM,ISI Grey/ Orient Heavy duty/CG EXHD300-4-1) of following sizes 12" (300mm)
F: Fixing of fans :--- S & F socket type Electronic fan regulator(230V,100W, step type ) (Anchor make) Vide page no E 6 Item no 18 a
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. Vide page no C-3, Item no 21.a.
Fixing only Wall Bracket fan on wall by S & F 8" x 10" size (1" Thick) HW Board, rag bolts, nuts and washers (6 mm dia x 62 mm long) or as required incl. S & F 24/.20 PVC insulated flexible copper wire 0.5 mt. length.
S & F fan down rod (14 SWG) incl. necessary connection wire (2X1.5sqmm cu wire) and painting the down rod as per direction of EIC
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: Vide page no C 4 Item no 28
G. Miscellaneous :--- Supply and installation of 1-Phase timer in double door SPN DB (2+10) way(Make- L K /Legrand) providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires(make-RR Kabel/Havells/Polycab). The box should be painted by powder coated paint. a) 25A DP MCB -1 No.(Make- L K /Legrand) (b)Analog time switch - 1 No.(Make- LK) (c) 2-pole 30A single phase power contactor, - 1 No.(Make- L K /ABB) (d) Add-on auxiliary contact block(1 NO+1 NC) -1 no(Make- L K /ABB) (e) 60A capacity 3 way AC/DC Epoxy terminal block.- 1 No. (f) Indicator Lamp (ESBEE make)-2 Nos. (g) Toggle switch,(ON_OFF_ON)- 1 No. (h) Steel Key Lock – 1 No. (Make- L K /ABB)
Supply & fixing 250V control starter type OLP 30M, 11-21A range, starter with AC looad display (make-- ultratech/Electron) incl modular box on wall with nut bolts etc as required. .
Supply and fixing ding dong type call bell (mk Anchor )
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. Vide page no D 13 Item no 22
PART -B ---A.C Installation Work. Supply & delivery 2.0 TR capacity, R407/410 concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Make : Hitachi / O-General / Daikin/Voltas )
Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC
Supply & Charging Refrigerant - R410 / R407C/R32
Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga) of 9 mm thick on Suction & Liquid Line Copper Pipe.
Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finilex / Havell's)
Supply and fixing flexible double canvass connection for concealed split air conditioners
Supply and fixing of Al powder coated continious Grill
Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.
Supplying, fabrication & fixing 3Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making platform for installation of outdoor unit of 7.5TR concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2Nos. horizontal angle of 25 mm x 25 mm x 5 mm of 1m. length incl. S&F of safety cage made of angle (25X25X5mm) and flat (25X5mm) iron with necessary painting incl. shade arrangement with corogated PVC shade with proper clamping arrangement
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support With 25x25x3mm angle iron support 300x50x1.25mm (18SWG) (for the protection of copper pipe)
Supplying, fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mm x 25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm having size of 600mm x 600mm ceiling with aluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer - in - charge. (PWD Bldg Schedule, Part G,P / No. 167, Item 22)
Construction of Trap Door (after proper cutting of ACP covering) made of Heavy Gauge Channel and particle board (hinged type door) for concealed split IDU maintenance as per direction of EIC. (Trap Door Size 3' x 1.5').
PART C: Fire Detection System installation work. Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detectors sensor with decentralize intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard. [Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost].(Approved Make: Cerberus Pro (Siemens))
Supply, Installation,Testing & Commisioning of soft Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Cerberus Pro (Siemens))
Supply, Installation, Testing & Commissioning of soft Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base ( VDS / UL / FM / ULC approved) . (Approved Make: Cerberus Pro (Siemens))
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / Polycab / RR Kabel) with 20 mm NB PVC rigid conduit pipe MMS (Make: Precisson / Polycab) on the surface of the wall.
Commissioning the existing panel after installation of new devices as per direction of EIC
Making necessary drawing of total installation and submit to the office as per direction of EIC.
NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
TESTS: 1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system under active monitoring of OEM. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Before taking up the work necessary building drawing/ floor plan with layout should be prepared and to be approved from the appropriate authority of PWD according to the prevailing fire safety policy. After commissioning, necessary testing to be done in presence of the appropriate authority of PWD.
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
The Panel should be compatible with existing Siemens make graphical user interface (GUI) system for controlling & monitoring all the devises of this BOQ, from the said graphical user interface (GUI). Necessary hardware & software including interconnection & programming support should be provided by the bidder at no additional cost. Before taking up the work necessary drawing/layout should be prepared and must be approved from the appropriate authority of PWD according to the prevailing fire safety policy. After commissioning, completion certification should be obtained from same appropriate authority of PWD without which payment should not be released.
Defect Liability period 1 (One) Year from the date of commissioning
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
M/S R. K. ENTERPRISE (BID ID -6727144)
M/s Singh Electrical Works (BID ID -6738166)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .