Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC Ms Navjeevan Enterprises is the lowest bidder | |
| 2 | L2₹41.8 L+₹1.4 L (3.35%)Rejected-AOC SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-AOC L2 | |
| 3 | L3₹43.2 L+₹2.8 L (6.86%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹44.3 L+₹3.9 L (9.65%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹44.4 L+₹3.9 L (9.75%)Rejected-AOC B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 May 2022, 6:00 pmClosed
GE Brichgunj
GE Brichgunj, Port Blair
REPAIR AND MAINT OF INTERNAL ELECTRICAL FITTINGS AND FIXTURES AND OTHER CONNECTED INTERNAL ACCESSORIES AT MAP AREA UNDER GE BRICHGUNJ
2022_MES_512301_2
GE8210
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Brichgunj
As per NIT
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹80,000
Yes
26 Jul 2022
25 Apr 2022
18 May 2022
25 Apr 2022
16 May 2022
9 May 2022
Amount
Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / ceiling etc. and including 1.5 sqmm copper cable FRLS PVC insulated and unsheathed cable 1100 volts as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: - (a) One light point/Bell point controlled by one switch
(b) One fan point controlled by one switch and one regulator
(c) One 3 pin switch socket outlet point 5 amps on same board with other switches.
(d) One 3 pin switch socket outlet point 5 amps on independent board.
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in PVC casing & caping for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm FRLS PVC insulated and unsheathed cable 1100 volts size for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning complete all as specified and directed.
Material & labour for point wiring as per colour coding with 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 19 mm thick rigid non metallic PVC concealed conduit medium quality including new sunken terminal boxes duly epoxy painted and 3mm thick plastic laminated sheet top cover and continuity earth wire PVC insulated copper conductor standard unsheathed of size 1.5sqmm including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in brick wall. complete all as specified and as directed. (a) One light point/Bell point controlled by one switch
(b) One fan point controlled by one switch and one regulator
(c) One 3 pin switch socket outlet point 5 amps on same board with other switches.
(d) One light point controlled by two two way switch.
(e) One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No.4 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4Sqmm earth continuty conductor, complete all as specified and as directed.
Material and labour for point wiring with 1.5 Sqmm FRLS PVC insulated single core stranded copper conductor unsheathed cable in the existing PVC concealed conduit/ surface conduit including fittings and accessories complete with PVC insulated copper conductor earth wire 1.5 Sqmm for one light/ one bell/ fan point through regulator point controlled by one switch in old/ existing cast iron/ pressed steel terminal boxes but with new 3 mm thick plastic laminated sheet top cover, painting existing sunken boxes with anticorrosive bituminous paint after thorough cleaning complete all as specified and directed.
All as per srl item No. 13 here in before but for 2/3 pin socket outlet 5 Amps multi purpose on independent board including continuous earth wire PVC insulated unsheathed copper conductor 1.5 Sqmm and connected to earth dolly, complete all as specified and directed.
All as per srl item No. 13 here in before but for 2/3 pin socket outlet 5 Amps on the same board including continuous earth wire PVC insulated unsheathed single core stranded copper conductor 1.5 Sqmm and connected to earth dolly, complete all as specified and directed
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable in existing PVC concealed conduit/Surface conduit for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm size for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning, all as specified and directed.
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed.
Supply and fix switch socket outlet 3 & 2 pin (mult pin) 5 amps flush/box type, complete all as specified and as directed.
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed.
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed.
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge.
Supply and fix switch piano flush type single pole two way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge Make:-Anchor/Havells/Bajaj
Supply and fix bell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed.
Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed.
Supply and fixing Modular Bell push 5A, 1 module all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined , 6/15 Amps, 2 module, 230 volts all as specified and directed.
Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed by Engineer-in-Charge Make :Legrand/C&S/L&T Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix in repair MCB triple pole and neutral 63 amps B series complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair MCB single pole and neutral, 240 volts, 6 to 32 amps,10KA,230V, B series complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair MCB single pole and neutral, 240 volts, 40 amps,10KA,230V, B series complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair MCB single pole 240 volts, 5 to 32 amps,10KA,B series ,230v complete all as specified and as directed by Engineer-in-Charge
S & F in repairs Single Pole and Neutral Enclosure with Two Pin Earth Plug and Socket complete with one MCB, SP, 20 Amps, 240 Volts all as specified and as directed.
S & F LED Wall light 20 Watt, white colour provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable wall light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.Make -Philips Model No- Grace or Equivalent in Cormpton/Havells.
Supply and fix bluk head in die cast aluminium housing & frosted glass with LED bulb 9 w prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
M & L in repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
M & L in repairs for sub main wiring complete with two runs of 4 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 4 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
Supply & Fixing in repair PVC Casing caping of following sizes with accessories like PVC saddles, bend,Tees,Elbow and screws etc. (a) 25 mm
S & F in repairs Heavy duty PVC Domestic Surface type for Switches of following sizes (a) 1 Gang Box
(b) 2 Gang Box
(c) 3 Gang Box
(d) 4 Gang Box
(e) 5 Gang Box
(f) 6 Gang Box
(g) 7 Gang Box
Supply and fixing energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
S & F LED mirror light fitting 1 x 10 Watt provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable mirror light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S&F 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Supply and fix Star surface mounted LED 12 w Round type with in die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.Make - Philips model no 59135 or Equivalent in Bajaj/Crompton
Taking down storage type water heater of 25 ltrs capacity of any make and any type and disconnecting inlet/outlet pipe connections complete, including dismantling and servicing, leak testing and refixing the same in position with suitable nuts and bolts and connecting inlet/outlet connections including testing and commissioning all as specified and as directed.
Supply and fix in repairs Heating element of 1500 watts, 240 volts suitable for existing complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs Thermostat element suitable for 25 ltrs capacity water heater, suitable for existing complete all as specified and as directed.
Supply and fix in repairs Geyser "Hot & Cold" PVC pipe line connecting to stop cock off 15mm dia, 450mm length all as specified and as directed.
Supply and fix scotch screw 10mm for installation of water heater
Supply and fix neon bulb red and green in colour for indication of water heater
Supply and fix top cover of water heater
Supply only bottom cover of water heater
Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed.
Supply and fix in repalcement canopy of ceiling fan, complete all as specified and as directed.
Supply and fix in repalcement ceiling fan hanging clamp with bush, locking pin and nut and bolt, complete all as specified and as directed.
Dismantling and taking down ceiling fan of any size/sweep from existing position complete with blades, down rod and canopy etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply and fix down rod of appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply and replace in repairs fan condenser 2.5 mfd, AC 440 volts, 50 Hz complete all as specified and as directed. (Make : Universal /KEIL/Havells)
Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified and as directed by Engr-in-Charge.
All as per item No 69 above but PVC Ventilation fan 200 mm sweep complete all as specified and directed.
Supply and fix in repairs condensor 4/3.5 mfd, AC 230 volts, 50 Cycles, complete all as specified and directed.
Supply and fix in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed
Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position complete all as specified and directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Material & labour, earthing complete with galvanize steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4.0mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No, 5 of MES Sch Part-1 (2009), complete all as specified and directed.
M&L in repairs Stringing drawing earth continuity wire PVC insulated unsheathed multistranded copper conductor FR/FRLS by opening junction boxes/corner/wall paneling/ fitting/ fixtures etc connecting to common earth point & connecting to earth dolly for following sizes. (a) 1.5 Sq mm
(b) 2.5 Sq mm
S&F 1100 Volt grade heavy duty twin core 10 Sq mm of size,(2 core) flat or circular cablePVC PVC tape and over all PVC sheathed as in sevice connections suspended by insulated hangers not more than 1.00 meter apart including 4 mm dia GI suspension wire and taking down old unservicable wire of any type and any size complete all as specified and directed.
Repairing the existing double door steel panel by welding etc, replacing of damaged/broken door hinges and repairing damaged door, and including painting with two coats of synthetic enamel paint in complete inner and out meter box including taking down of meters and , DB and refixing of meters/DB box etc complete all as specified and directed
Numbering of meter box with black paint Qtr wise complete all as specified and directed.
A. R. ELECTRICALS
bansal construction
SHUSHANT ASSOCIATES
KAPOOR AUTOMOBILES
Kakolil Trade Agencies
AMR TRADERS
PSS ELECTRICAL WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .