| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC RATES QUOTED ARE REASONABLE | |
| 2 | L2₹29.7 L+₹5.3 L (21.9%)Rejected-Finance | L2 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹44,500
Closing Date
1 Jul 2021, 6:00 pmClosed
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE THANJAVUR
CONSTRUCTION OF TWO CLASS ROOMS FOR KG SCHOOL AT AFS THANJAVUR AND PROVISION OF LIGHTNING ARRESTER WITH AOL OF 15m HEIGHT OPS LOCATION AT KODIAKKARAI
2021_MES_450370_1
8830/E8
Open Tender
Civil Works
Lump-sum
270 days
THANJAVUR
AS PER NIT
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER AIRFORCE THANJAVUR
₹44,500
Yes
28 Oct 2021
10 Jun 2021
2 Jul 2021
10 Jun 2021
1 Jul 2021
17 Jun 2021
Amount
GENERAL SUMMARY NOTE: Schedule 'A' Part-I to II are prepriced by MES under Ser No 2.00 to 3.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for "BUILDING OR WORKS" as listed in Sch 'A' Part-I.
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Sch 'A' Part-II.
Note:- Schedule 'A' Part-III (Misc items) are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green filed under Col.6
INTERNAL ELECTRIFICATION:- Supply and fix SABER LED merges Classic styling with cutting edge technology suspended mounted, 4 feet system wattage of 36/40 watts (included suspension system)with life time of 50000 burning hours with 70% of its intial lumen maintained. CRI>80, power Factor >0.95,TDH< 10% colour temperature - 6500K, surge protection 3KV in cm , IP-20 protected, meets LED IS specification,Class-1,SDCM<5, Short circuit and over circuit protection, voltage range-150 to 270 Volts AC, Temprature range 0 to 50 Degree C, system efficacy at luminaire level ≥ 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible from ceiling rose to fitting fixed complete all as specified and directed. Make : Havells catalogue No SABER LP36W LED840SPMMAWH. OR QUIVALENT MAKE PHILIPS/ WIPRO
Supply and fix of LED Security/Street light fitting ENDURA PEARL 30W MP around and the building, aluminum pressure Die cast housing with pure polyester powder coated for long life ,High purity lenses for superior performance, IP66 Protection, suitable for external pipe dia Up to 50 mm, with luminaries efficacy >100lm/W,driver Voltage range 150- 270V AC, Temperature range-0 to 50degC,Driver efficiency > 85%, Power factor > 0.95, TDH<10%, CRI >70 , Colour Temperature- 6500K , With luminaries efficacy ≥ 100 Surge protection from overvoltage- 3.5KV in CM , Safety Extra Low voltage safe level <60V DC as as per IEC standerd 50000 burning hoursas per L70 criteria, including provision of 40mm GI light grade pipe 1.5 mtr length bend to shape and necessary clamp etc for fixing the light fittings on wall/ pole fixed complete all as directed. Make :Havells Cat part No ENDURAPEARLS30WLED757SASYTOPCMP or equivallent make PHILIPS/ WIPRO.
Supply & fix Ceiling Fan 1200 mm sweep single phase 50 HZ BLDC technology , 5 star rated 26 watt and making connections with PVC insulated and sheathed 2/3 core copper wire complete all specified and as directed by engineer in charge. Make Havells Cat Part No EFFCINCIA (BLDC) or equivalent in Crompton
S&F of Lightning Arrester type PETEX-L early steamer emission (ESE) terminal for protection from external lightning strike with range of protection 107 meter radius of protection level-4, maximum surge handling capacity 200 KA , sensitivity 3KA, IP-65 protection and CPRI approved, Environment, Emission Test, Mechanical Test of the ESE Terminal with NFC -17 102 Δ T:60Ms, relative humidity upto 97% complete all as directed of Make: FOREND of M/S 2C Technologies, Hyderabad, M/S Nexeon Power Technologies, Noida, Aegis Power Solutions Pvt Ltd, Vadodara.
S&F lightning counter or lightning strike counter with digital illuminated display with 6 digit counter facility, IP -20 protection IEC/ EN 62561-6 with all connection including fixing accessories of lightning counter complete all as specified and directed by engineer- in-charge . Make Protec Power solutin / Tursel / Alltec/ CAPE Electric or quivalents.
S&F self-supported 15 mtr triangular type GI mast consisting of various members fabricated from hot dip galvanized as per IS 4759-1968, IS: 1161-1998 and IS: 4736. All unspecified holes should be 17.5 mm dia for 16 mm dia bolts confirming property class 5.6 for all members of tubular hybrid mast. All welds should be 6mm fillet UNO. All tubes should be confirming to grade YST 240 MPS as per IS 806-1968. Filled connection shall be bolted with lock washers. No field welding should be allowed. Tolrance for fabrication of steel structures IS: 7215 complete all as specified and directed as per the sketch enclosed in Appendix "A". Note: The rate is inclusive for two coat of enamalled panit over a coat of redoxide on 15 meter tower.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 70 sqm single core. Make L&T/ Havells/ Plaza / Finolex
S&F red LED aviation obstruction light with IP 55 rating 36/40 watt aluminium alloy material body input voltage 180 to 280 volts, Make: cat part no 110731 of Bajaj or equivalent in Geltronix.
Supply, installation, testing and commissioning of chemical earthing system. The earthing shall consist of :- a) 4 Nos of copper rod of dia should not be less than 15 mm and length 3 meter. b) The electrode shall be installed in a 150 mm dia 3000 mm deep augured bore hole. The hole shall be filled with highly conductive and eco friendly ground enhancing compound as per IEC 62561-7 shall not be less than 50kg per pit. c) 4 No of copper bus bar size 25x50x150 mm should be exothermic welded with copper rod. d) 4 No pre cast chamber with cast iron pit cover for covering the earthing bore holes. e) Exothermic connection of 25x6x150 mm bus bar to 70 sq mm copper cable. Note: (i) Distence of earth pit (centre to centre) should not be less than 3 meter. (ii) The quoted rates are inclusive 4 numbers bore holes of size 150 mm dia and 3 mtr depth. (iii) The datails are as per the sketch enclosed in Appendix "B".
M&L for PCC foundation 1:2:4 type B1 (using 20 mm graded stone aggregate) of size 1.2 mtr x 1.2 mtr x 1.7 mtr for self supported 15 meter height triangular type GI mast. Mast foundation shall be designed to bear 150km/hrs wind load being a sea shore area including excavation work for mast foundation complete all as directed by engineer in charge.
Supply, laying/ fixing of PVC insulated, PVC sheathed cable galvanized steel strip or wire armored, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,3 core, 1100 Volts grade. Electrical connection will be done from exiting street/ security light pole loop in loop out FRP box complete all as directed by engineer in charge . Make : L&T/ Havells/ Plaza / Finolex
Returning and filling of trenches in two parts (i) using riddled soil obtain from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
Note: BOQ sl.No: 08 to 16 & Sch “A” Part- II Sl.No: 15 to 19 is to be carried out in Kodiakkarai which is 120 Km (appx) away from this station. The rate quoted by the bidder is deemed to inclusive of the factors involved in quoting accordingly
p.chinnasamy
Bidder Name
p.chinnasamy
A.AROCKIA JUSTIN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .