| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.0 L+₹25,385 (0.73%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹39.9 L+₹5.2 L (14.9%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹58.9 L+₹24.2 L (69.6%)Rejected-Finance 412 51 PUL MOTIL LAL CHOWK LUCKNOW 226003 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226003 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
26 Nov 2019, 6:00 pmClosed
GE E/M Lucknow.
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR / MAINT OF WATER SUPPLY DISTRIBUTION SYSTEM AT VARIOUS LOCATIONS INCLUDING REPAIR MAINT OF RUSTED CORRODED CI/GI/DI PIPES UNDER AGE E/M EXT(WS) OF GE E/M LUCKNOW.
2019_MES_258470_2
GE/EM/EXT(WS)/ 20 OF 2019-2020
Open Tender
Civil Works
Item Rate
180 days
Luclnow Cantt
Class D or above category a (ii)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow.
₹98,000
Yes
3 Jan 2020
31 Oct 2019
27 Nov 2019
6 Nov 2019
26 Nov 2019
14 Nov 2019
Amount
S&F in repair (including taking down old unsv cable) PVC insulated & sheathed , heavy duty electric cable on RCC Pillar / dome of over head tank at height of 26 meter approximatelly from normal ground level including fixing arrangement with Copper conductor,multi stranded 1100 volts grade flat 04 Sqmm 3 core and taking out of existing unserviceable cable complete all as specified and directed by Engr-in-charge.
Supply, laying in repair (including taking down old unsv cable) XLPE insulated, armoured, heavy duty electric cable with aluminium conductor 1100 volts grade with stranded aluminium conductor complete all as specified and directed by Engr-in-charge of sizes 04 SQMM 02 core (Note :- Excavation & earth work will be measured and paid separately under respective item).
M&L in repair aviation Light fitting 100 Watt 230 Volts 50 Hz yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories.MAKE BAJAJ CAT PART NO-024973 BJAOL 2 BC GLS 2 x 100W BC or equivalent make in CG/Philips
S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240V,of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 02 way complete all as specified and directed by Engr-in-charge.
S&F in repair MCB single pole & neutral 20 Amp rating 'C' Series 240 Volt complete all as specified and directed by Engr-in-charge.
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of GI strip of size 32x6mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 50mm bore light grade GI pipe for protection of strip and GI pipe 20 mm light grade 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed by Engr-in-charge.
Supply ,laying,jointing and commissioning & testing of ductile iron water mains in repairs (including taking down) with flanged ends, centrifugally cast of class K-9, and wall thickness 6mm complete all as specified and directed of following bore sizes (note- rubber gas kit joints and CI specials/fitting shall be measured and paid separately)
S&F in repairs cast iron specials 'ISI marked' for pressure water mains up to 150 mm bore spigot and socket Tee,pieces, single or double branch connection or collar etc. complete all as specified and directed. (Note - Excavation and earth work shall be measured and paid for separately).
ditto all as item 8 above 200 to 300 mm bore for pipe line/header
S&F in repair cast iron connecting pieces one end flanged and other socket or spigot or bell mouth or any size tapper upto 300 mm bore complete all as specified and directed. (Note - Joints excavation and earth work shall be measured and paid separately)
M&L in repair run lead joints including burning out of old lead joint for spigot and socket ends for fittings/water mains in repair for new/old pipe lines and fittings of the following size complete all as specified and directed :-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
M&L in repairs flanged joints including dismantling existing flange joint complete with rubber or fibre board gasket for new/old pipe lines including nut bolts & washers etc. of the following sizes of water mains/fittings complete all as specified and directed :-
80 mm bore.
100 mm bore
150 mm bore.
200 mm bore.
Cutting in position cast iron water mains for insertion of new tee for branch connection all as directed for the following size :-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
M&L in repairs short pieces of CI/DI pipe duly thread and both end flanged as per site requirement upto 60 cm for the following sizes (Note- Length of pipe more than 60 cm will be measured and paid in the respective item of CI/DI pipe.):-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
S&F in repairs GI pipe medium grade including taking down of old /unsv G.I. Pipe with all fittings and fixed complete to wall / ceiling or laid in floor /trenches etc. complete all as specified and directed (Note - Excavation & earth work shall be measued paid seperately) of the following sizes
15 mm bore.
20 mm bore.
25mm bore.
40mm bore.
50mm bore.
80mm bore.
Cutting in position existing steel tubing for alteration or repair including screwing/threading complete all as directed of the following size:-
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
S&F in replacement gun metal globe or gate valve 'ISI marked' with iron wheel head screwed both end for iron pipe all as per latest IS specifications of the following sizes
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
Drilling &Tapping cast iron water mains in postion for branch connection of the following sizes :-
15 mm bore.
20 mm bore.
S&F in repairs (including taking down) connection & testing sluice valve both ends flanged and drilled cast iron body class PN-1conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts etc complete all as specified and directed of the following sizes :- NOTE: For those sluice valves which are fixed with pillar of over head tank work involve such as breaking of RCC/lead flange joints will be deemed to be included in the quoted rates, contractor will also repair the demaged floor etc.to match with existing (Joints shall be measured & paid seperately)
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
S&F in replacement Gun metal spindle with qutku "U" thread suitable for any make /model sluice valve of the following sizes :-
200 mm bore.
150 mm bore.
100 mm bore.
80 mm bore.
S&F in nreplacement of stuffing box of sluice valve complete with gland plate nut bults & gland packing etc. complete all as specified and directed of the following sizes :-
200 mm bore.
150 mm bore.
100 mm bore.
80 mm bore.
M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation of pillar/wall complete all as specified and directed.
M&L in repairs for valve pit masonery chamber of size 650x650x650 mm (internal dimension) with MS plate 3 mm thick top cover locking arrangement 50 mm lock - 01 No including painting with two coat of synthetic enamel paint over a coat of red oxide primer including excavation earth work, PCC plaster etc complete all as specified and directed and shown on drawing.
internal dimension 900x900x900 mm.
internal dimension 1200x1200x1000 mm.
M&L PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping in supporting pillar for pipe wall etc wall complete all as specified and directed.
M&L brick work with sub class 'B' bricks buit in CM 1:6 using old size bricks straight or curved on plan exc. 6 M mean radius complete all as specified & directed.
M&L rendering 10 mm thick with CM 1:6 on fair face of brick or concrete surfaces complete all as specified and directed.
M&L Fabricated MS work as in bands, straps supports or stay for pipe inlcluding bolts if required conforming to Fe-410.0 or Fe-310.0 complete all as specifed and directed.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for laying / taking out water supply pipe line in soft/loose soil, taking out excavated material,forming bottom etc complete all as specified and directed..
Returning filling in including,spreading ,levelling watering and well ramming in layer in n.exc 25 cm in soft/loose soil all as specified directed.
Removing excavated material n.exc 50 mtr and deposting where directed at a level n.exc. 1.5 mtr above starting point as in soft/loose soil complete all as specified and directed.
Cutting of road (in hard/ dense soil ) for laying pipe line or repair to pipes / lead joints etc .of any size upto 01 mtr. Depth and getting out including forming bottom surface to required level and making good the road as per existing all as specified and directedby EIC.
Drilling/boring (horizontally) upto 150 mm bore by penumatic tool or horizontal boring/drilling machine under the existing road (max. 10 mtr. In width) suitable for passing GI/CI/DI tubing complete all as specified and directed by EIC.
S&F in repairs Fountain light LED outdoor garden spot and spike 05 watt IP-65, warm white 3000k Aluminium body suitable for 230 VOLT,50 Hz.A.C. complete all as specified and directed.
S &F in repairs Fountain brass Nozzel 1/4 " adjustable jet straight /pound fountain nozzle heavy duty suitable for garden irrigation watering humidification etc.all as specified and directed
Supply and spread fine dry sand locally available for cable cushioning complete all as specified and directed by Engr-in-charge.
M&L for laying sub class 'B' brick in trenches as cable protection covers across the length of the cable complete all as specified and directed by Engr-in-charge.
Supply and Fixing in repairs (including taking down) pipe ductile Iron , S/S including specials, Class “K-9” ,150 mm (6”) dia across the RCC Pillar /Dome of over head tank at height of 26 meter approximatelly from normal ground level including fixing arrangement of bamboo or Steel tubing with suitable locking etc. as directed.
S&F in repairs brass column style fountain nozzle garden sprinkler pond fountain water nozzle heavy duty , sprinkler spray size 10x5x5 cm complete all as specified and directed by EIC.
S &F in repairs including taking down etc 50 mm dia (outer) 3-Layer PP-R ( Polypropylene random copolymer ) concealed pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropolene random fittings laid in trenches of following sizes.all as specified and directed by EIC. Note:-Excavation and earthwork shall be meassured and paid seperatelly.
63 mm dia (outer)
75 mm dia (outer)
90 mm dia (outer)
110 mm dia (outer)
M/S Nav Jyoti Enterprises
Sanjai sales and services
M/s I C Sharma and sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .