Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC INDEX NO D 35 ADG NEI GUWAHATI OLD HASIMARA POST HASIMARA DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹45.4 L+₹5.8 L (14.5%)Rejected-Finance SUBHASINI TEA ESTATE HASIMARA PS JAIGOAN DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹46.7 L+₹7.1 L (17.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹47.1 L+₹7.5 L (18.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹48.4 L+₹8.8 L (22.2%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
1 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
ADDN/ALTN TO OLD HANGER FOR GROUND CREW REST ROOM, PROVN OF AC FOR STORAGE BLDG/COMPATMENTS FOR EAX/POWER CARTIDGES/PYROTECHNICS IN STN ARMOURY, WORK SERVICES FOR CONSTRUCTION OF SEPARATION WALL IN NGLGB LAB, PROVN OF WIRELESS REMOTE FOR OPERATION OF
2024_MES_670503_1
C/8808/2024-25/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹78,000
Yes
4 Oct 2024
2 Sept 2024
3 Oct 2024
2 Sept 2024
1 Oct 2024
17 Sept 2024
Amount
S&F for 600 x 600mm GI frame work for seamless ceiling comprising of Gl perimeter channnel 0.55mm thick with two unequal flanges of 20 and 30mm and web of of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and providing 4mm non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/aluminium framework with screws, 60 x 60cm in size, fixed with nails to timber framework or with staples on snap grid, complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description n. exc. 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, complete all as specified and directed.
M&L for brick work with sub class 'B' brick,s old size, burnt clay bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:6), complete all as specified and directed.
M&L 15mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and directed.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. including brushing neat cement slurry with and including 3 kg of cement per Sqm, complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregrate) as in beams, cantilevers. bressummers, lintels etc., complete all as specified and directed.
Use & waste formwork to sides and soffits of floor or roof beams, beam haunching’s, girders, breastsummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. fair finish flat surfaces of formwork, complete all as specified and directed.
S & F mild steel TMT bars 10mm dia and over (Grade Fe-500D or heigher), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia., or securing with clips, complete all as specified and directed.
M&L for applying of 2mm thick wall care putty over newly plastered surface to prepare the surface even and smooth and applying two coats of acrylic oil bound distemper (1st grade quality, ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification, complete all as specified and directed.
Taking down chowkats with shutter (without taking off shutter from the frame) not exc. 1.5 Sqm each., complete all as specified and directed.
Supply installation, testing and commissioning of wireless radio remote control dual speed for all motion EOT cranes with receiver station installed in cranes, stationary at one side for range of 100m maximum complete including all connected work required for installation of remote operation including re-fixing of existing hanging type remote operation switch carefully into cranes, complete all as specified and directed. Make: Gunatit Electro Power Pvt Ltd or equivalent model of Dinesh Enterprises/Microtech Engineers & Co/Electromech Material System India (P) Ltd
Supply and install split type Air conditioning units 1.5 TR indoor and outdoor complete with cordless remote control unit and with 5 star rated/BLDC type compressor unit with non CFC refrigerant, auto swing, LED display, noise level not more than 42 db function complete with all piping arrangment, etc complete all as specified and directed.
Supply and install split type Air conditioning units 2 TR indoor and outdoor complete with cordless remote control unit and with 5 star rated/BLDC type compressor unit with non CFC refrigerant, auto swing, LED display, noise level not more than 42 db function complete with all piping arrangment, etc complete all as specified and directed. Note for item No. 15.00 & 16.00 : (i) Condensate drain pipe of best quality to be provided and fixed in suitable manner till ground level/max up to 6.0 Mtrs fixed on wall/floor/ceiling. (ii) The quoted rate includes necessary fixing arragement for indoor and outdoor units and copper tubing upto 6.00 mtr length, brazing, welding including insulation, complete charging of refrigerator gas upto required level and filling the cavities on wall and setting of grill alignment and including testing & commissioning, complete all as specified and directed.
S&F voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5%, with digital display automatic high and low cut out with wall mounting accessories, complete all as specified and directed.
S&F voltage stabilizer of capacity 1 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5%, with digital display automatic high and low cut out with wall mounting accessories, complete all as specified and directed.
M&L for removing the split type AC/window type AC unit from existing position, including dismantling of all piping on wall/floor/ceiling of capacity 1.5/2 ton of any make and type and deposited to MES store complete with indoor, out door unit with remote, all copper tubing out door wall mounting bracket, complete all as specified and directed.
Supply and draw sub main wiring in repairs of two run 4.0 Sqmm single core (FRLSH) PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit (ISI marked), medium duty, of not less than 25mm size including all conduit accessories, concealed to the surfaces of the wall/ceiling including one run of 4.0 Sqmm single core (FRLSH) PVC insulated unsheathed copper earth continuity including taking down existing sub-main wiring, complete all as specified and directed. Note: (i) Two runs of single core cable with one run of earth continuity conductor including PVC conduit & accessories shall be measured and paid as one length. (ii) Cutting chases shall be measured and paid separately.
All as per item No. 20.00 here-in-before but drawn in and including casing-caping of suitable size, complete all as specified and directed.
S&F MCB DB 6 to 32 Amps, 240V, 10 KA, 'B' curve, including connection of testing, completes all as specified and directed.
S&F power unit suitable 25 Amp including sockets 25 Amps, and 02 module box for mounting of power unit and power socket, complete as specified and directed.
S&F in repair modular socket 16 Amp, 2 module box for mounting of power unit and power socket, complete all as specified and directed.
S&F in repair metal flush box, 2 module, mounting of power unit and power socket, complete all as specified and directed.
Supply and install refrigerator, electric driven (single phase), capacity 230 litres, 3 star, double door eco friendly CFC free refrigerant, frost free refrigerator, auto defrost function to prevent ice-build up with power plug of suitable rating including power cable with base stand, complete all as specified and directed.
Supply and install refrigerator, electric driven (single phase), capacity 310 litre, 3 star, double door eco friendly CFC free refrigerant, frost free refrigerator, auto defrost function to prevent ice-build up with power plug of suitable rating including power cable with base stand, complete all as specified and directed.
Supply and install refrigerator, electric driven (single phase), capacity 320 litres, 3 star, double door eco friendly CFC free refrigerant, frost free refrigerator, auto defrost function to prevent ice-build up with power plug of suitable rating including power cable with base stand, complete all as specified and directed.
Supply, installation, commissioning of glass top deep freezer capacity 400 litres capacity single phase 240 volt, 50 Hz 5 star rated with power plug of suitable rating including power cable, complete all as specified and directed. Note for Sl item Nos. 15.00, 16.00, 26.00 to 29.00: (i) Contractor has to submit the type/star rating/color of brand for approval from GE. Cost escallation with respect to minor variation of cooling capacity over and above described in BOQ as per the market availability/as per brand submitted by the contractor shall be deemed to be included in unit quoted rate. Contractor has to confirm the market availability of Nominal cooling capacity/type of Compressor/Eco friendly CFC refrigerant. (ii) Nominal cooling capacity of refrigerator/deep freezer is varies as per brand/star rating/local market availability. Quated rate for refrigearor is deemed to be included the variation of colling capacity maximum up to 10 % mentioned in BOQ.
M&L for point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLSH) size 4 sqmm drawn in and including PVC casing and caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan point controlled by one switch with pressed steel concealed terminal boxes covered with 3 mm thick laminated sheet / modular plate incl continous earth wire of PVC insulated unsheathed, (FRLSH) multi stranded copper conductor cable size 4 Sqmm for earth wire connected to common earth dolly, complete all as specified and directed.
S&F in repair socket outlet modular, 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, complete all as specified and directed.
S&F air circulator fans 230 volts single phase oscillating 450mm sweep, speed 1440 RPM, air delivery 125 CMM, power 100W with double ball bearing suitable for wall mounting with fixing arrangements and connecting up to ceiling rose with flexible wire, completes all as specified and directed.
S&F in repair switch modular type single pole, one way, 6 Amp, complete all as specified and directed.
S&F modular type sockets outlet 3 pin, 6 Amp, 02 module box for mounting socket, complete as specified and directed.
S&F power unit suitable 25 Amp including sockets 16 Amps, 04 module box for mounting of power unit and power socket, complete as specified and directed.
S&F sheet metal enclosure for double door MCB DBs, Triple Pole & Neutral (TPN), suitable for 8 way, 415 volts, IP 43 & IK 09 with metal door fixed on wall with din rail, neutral and earth bar, fixed in proper position, complete all as specified and directed.
S&F MCB TPN 40 to 100 Amps, 10 KA, 'B' curve, complete all as specified and directed.
S&F MCB SP 5 to 32 Amps, 10 KA, 'B' curve, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core including taking down old unserviceable UG cable of any description, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole/stay, or cable trenches etc and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
M&L for sub class ‘B’ old size bricks, burnt clay bricks, laid flat, dry in trenches for cable protection, complete all as specified and directed.
Supply, filling in trenches, spreading, leveling sand cushioning 8cm below cable and 15cm above the cable punned down to 18cm for under ground cable, complete all as specified and directed. (Note : Punned thickness shall be measured for payment)
Horizontal boring under the road (with manual method) below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed.
S&F socket outlet, modular, flush type, 5 pin, 6 Amp, 03 module, complete all as specified and directed.
S&F socket outlet, modular, flush type, 6 pin, 6/16 Amp, 03 module, complete all as specified and directed.
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including PVC conduit, medium grade, (ISI marked) , heavy duty of adequate size including its accessories not less than 20mm dia rigid PVC conduit 'medium grade ISI marked including all conduit accessories including pressed steel terminal box of required size factory made with top cover of ISI marked plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole, complete all as specified and directed.
All as per item No. 48.00 here-in-before but one switch socket combination 6 pin 5/15 Amp on independent point including PVC cable 2.5 Sqmm FRLSH type copper stranded conductor along with 2.5 Sqmm continious PVC insulated unsheathed standard copper conductor cable FRLSH type for as earth wire, complete all as specified and directed.
S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% and capacity 5 KVA, complete all as specified and directed.
M & L for flameproof point wiring surface/concealed type with 4 Sqmm (nominal cross sectional area) with PVC insulated unsheathed single core stranded copper conductor (ZHFR/HFFR) cable of working voltage 1100 volts grade conforming to IS-694 drawn in and including steel surface conduit with all fittings & accessories such as FLP flexible conduit, FLP junction box, brass glands/connector, bends etc. with 1.60mm thick pressed steel or mild steel sheet sunk box, including 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed single core stranded copper conductor (ZHFR/HFFR) cable as earth continuity conductor connected to main switch/ 'DB's or common earth dolly for one fan/light point controlled by one 16 Amps single pole FLP switch for the point wiring, complete all as specified and directed.
M & L flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P + earth (3 Pin) having full proof interlocking i.e plug cant be removed in ON condition, complete all as specified and directed.
S&F of flameproof split air conditioner CIMFR certified capacity 2 ton with flame proof indoor and outdoor unit, single phase, hermetically sealed explosion proof compressor working on R-407C, Eco-Friendly refrigerant, cooper cooling coil, flame proof control panel with indication lamp for (power on, compressor on, cooling motor on, compressor trip and cooling motor trip), temperature indicator 2 relay output, FLP RTD PT 100 3 wire, MCB, contactor & overload relay for protection compressor and condensing motor, cooling motor, suitable MCB for incoming, drainage pipe of suitable length, copper tubes for suction and discharge line of suitable length and dia complete all as specified directed.
M & L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, (ZHFR/HFFR) type, cables 6 Sqmm drawn through in and including steel conduit, 20mm dia, heavy duty surface conduits including 6 Sqmm ZHFR/HFFR) type, PVC insulated unsheathed multi stranded flexible copper conductor cable, 20mm dia as continuous earth wire with and including stove enamelled steel conduit of suitable size and connecting to common earth terminals including taking down existing sub-main wiring any size, complete all as specified and directed. Note :- Three runs of cables and one run of steel conduit and its accessories shall be measured as one length.
S&F in repair flame proof sheet metal enclosure 8 way SPN for sigle door IP 66 MCB DBs, phosphatised, powder coated, Triple Pole & Neutral (SPN) 63 Amp as incomer and 16 Amp SP MCB - 06 Nos & 06 Amp MCB-06 Nos as ougoing connection, 415 volts, IP 43 & IK 09 with metal door fixed on wall with din rail, neutral and earth bar, in proper position, complete all as specified and directed. Note : Cost of MCBs SPN & SP shall deemed to be included in the unit quoted rate.
M & L for flame proof junction box 8 way, 100mm dia with plain cover 3/4" ET, complete all as specified and directed.
M & L for heavy duty flame proof flexible metalic hose conduit of dia 20mm 300mm long, complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR including fixing arrangement, suction/discharge tube with proper insulation and drain pip of suitable diameter, completes all as specified and directed.
Note: An amount of Rs.2100.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S. VINITA CONSTRUCTION (BID ID -3123289)
M/S ANIL KUMAR BAUL (BID ID -3123399)
M/S SANMILAN NANDI (BID ID -3123447)
M/S ASHOK ENTERPRISE (BID ID -3122869)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .