Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹42.4 L+₹1.0 L (2.51%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹45.1 L+₹3.8 L (9.15%)Rejected-Finance 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
7 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR AND IMPROVEMENT OF LT NETWORK CABLE AND PANEL UNDER GE (EAST) MATHURA
2022_MES_568536_1
8200-1318/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹1 L
13 Jan 2023
10 Dec 2022
9 Jan 2023
10 Dec 2022
7 Jan 2023
24 Dec 2022
10 Dec 2022 - 31 Dec 2022
Amount
Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundations, laying of cables and getting out in soft/loose soil complete all as specified and as directed.
All as per item serial No 2.00 here-in-before but depth exc 1.5 m but n exc 3.00m complete all as specified an as directed.
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep as specified after laying and stretching the cable and punned complete all as specified and as directed. Note:- Punned depth shall be measured for payment.
Supply and laying PCC cable cover class LV type 1 flat size 250 mmx150mmx40mm complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supply and laying GI Pipe light grade with all fitting and fixed complete to walls/poles/underpass and ceilings or laid in floors complete all as specified and as directed of following sizes:-
50 mm bore
80 mm bore
100 mm bore
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 10 to 16 Sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 400 sq mm complete all as specified and as directed.
Supply and Fixing in replacement of Ammeter on LT panel board/Bus bar/LT feeder box in four step (R,Y,B and OFF) without CT, 63 Amp rating including nuts,bolts etc complete all as specified and as directed.
Supply and Fixing in replacement of Voltmeter on LT panel board/Bus bar/LT feeder box in four step (RY,YB,BR and OFF) including nuts,bolts etc complete all as specified and as directed.
Labour & tools for trimming tree branches upto 100 mm girth of any location around existing HT/LT OH lines giving clearance of 1.5 m on all sides complete all as specified and as directed. Note : Trimming of tree branches irrespective in numbers in each tree shall be measured as one unit).
Supply and fixing in replacement of CT coil suitable for Amp meter 100 /5 Amp complete all as specified and as directee.
Supply and fixing in replacement of indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing one complete all as specified and as directed.
M&L for carrying out calibration of Air Circuit Breaker 630 Amp to 1000 Amps,over fault relay,earth fault relay,checking of alignment of ACB isolating contacts,servicing of electronic operating mechanism including tripping and closing system of the breakers,dehydrating,decorbonising of panel,bus section & circuit section. Removing perished monoplus compound cleaning and re-insulating with LT taps wherever necessary ,also supply and fixing Outdoor/indoor type ACB mounting panel conopy as per suitable size 2.00 mm thick CRCA sheet ,front and back opening and locking arrangement of ACB mechanism,with fixing arrangement at foundation and including replacement of burnt out/defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc, underthe supervision of authorised dealer/representative, and refixing the ACB breaker in its original position and testing entire satisfaction of Engineer-in-charge.
Supply and fix in replacement LT heavy duty 4 pole OFF load change over break switch ,415 volts 50 hz complete with handle assembly having door interlock and pad locking arrangement in sheet steel enclosure. of 400 Amps, incl electric connections to the extg cables complete all as specified and as directed.
Supply and Fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed.
Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape / wire armoured heavy duty electric underground cable, 1100 volts grade with stranded aluminium conductor of following nominal cross sectional area :-
10 sqmm 2 core.
16 sqmm 4 core.
25 sqmm 3.5 core.
35 sqmm 3.5 core.
50 sqmm 3.5 core.
70 sqmm 3.5 core.
95 sqmm 3.5 core.
120 sqmm 3.5 core.
150 sqmm 3.5 core.
185 sqmm 3.5 core.
240 sqmm 3.5 core.
300 sqmm 3.5 core.
M&L for chemical earthing in replacement with copper earth plate electrode 90 cm X 60 cm X 5 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 32 X6 mm as earthing strip by means of bolts,nut check nut and washers protected with and including 40 mm dia medium grade GI pipe, necessary excavation and earth work, magnesium sulphate (80 Kg), charcoal (2 Qtl) and common salt (2 Qtl) filling, watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover, GI funnel with test point, testing (all as shown in electrical plate No 5 and commissioning complete all as specified and as directed. Note:- On testing ,after completion ,if the earth resistance below 1 Ohms is not obtained ,earthing will rejuvenated at no extra cost till the desired earth resistance is obtined.
Dismantling of old unserviceble Aluminium conductor off sizes from existing over head lines complete all as specified and as directed.
All as per item serial No 28.00 here-in-before but GI wire/stay wire.
Dismantling/taking down old unserviceable pin/loop/shackle type insulator any type/size complete all as specified and as directed.
Dismantling U/S cross arms and anti climbing devices of any size from pole /structures complete all as specified and as directed.
Dismantling of stay assembly complete from site complete all as specified and as directed.
M&L for ACSR conductor any sizes drawn over for over head lines fixed to insulators with binding wire after allowing specified sag complete all as specified and as directed.
M&L for GI wire 4mm dia as continuous earth wire, guarding and craddles to OH line including binding wire complete all as specified and as directed.
Supply & fixing pin type porcelain vitreous insulator 100 mm height and 65 mm dia for 1100 Volts grade including galvanised mild steel spindle, one nut and two washers complete all as specified and as directed.
Supply and fixing shackle type insulator porcelain vitreous white,brown and green of size 75 mm heaight and 90 mm dia incl galvanised MS straps 31x3 mm size ,washers,insulator bolt 12 mm dia and nut for working pressure 1100 Volts grade complete all as specified and as directed.
M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5 mm complete all as specified and as directe.
M&L for work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directe.
M&L for stay assembly complete with MS stay plate 300x300x6mm thick galvanized stay rod not less than 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc all as shown in electrical plate No1of SSR part-I complete all as specified and as directed. Note : Excavation,earthwork,cement concrete loop type insulators and stay wire shall be included in quoted rates.
M&L Galvanised stay strand, size 7/4mm complete all as specified and as directed.
Dismantling steel tubular poles of any size complete all as specified and as directed.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-31 (9.00 metre long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as as directed. Note : Earth work and PCC in foundation shall be measured separately.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-55 (11.00 metre long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation shall be measured separately.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600mm x 600mm x 6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. RCC cover with concrete (1:2:4) type B-1 using 8mm bars @ 100mm C/C both way with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion including taking down existing earthing complete all as specified and as directed. Note : The unit rate includes for protection pipe and GI Earth strip 32 x 6mm from top of earth plate upto 7.5m above ground level.
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified and as directed. Note : GI wire and protection pipe upto 7.5 Mtr length from earth electrode shall be included in quoted rate of item.
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
M&L for cutting wild grass, bushes, creaper, unwanted vegetation and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance from inside / surrounding of E/M sub station (transformers) including cutting creapers from barbed/cattle fencing of the sub stn as when directed and removing of unwanted material from installation fencing/compound and depositing where directed after taking proper electric shutdown form MRS Mathura. Note :- (i) The item shall be operated maximum two times in entire period of contract in the same installations. (ii) Area measured separately each time.
Supply and fixing in replacement of MCCB 630Amp rating (Ics = 100% of Icu), 4-pole 415V, Electronic release with overload and short circuit adjustable type breaking capacity 50 KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 400Amp rating (Ics = 100% of Icu), 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 50 KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 250Amp rating (Ics = 100% of Icu), 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 160 Amp rating (Ics = 100% of Icu), 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 100Amp rating (Ics = 100% of Icu), 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 63 Amp rating (Ics = 100% of Icu), 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 250Amp rating (Ics = 100% of Icu), 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 200Amp rating (Ics = 100% of Icu),3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.
M&L for preparation of steel structures surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and as directed. Note : The tools like ladders etc for painting of pole structures at MRS upto height 11 metre is included in quoted rate. No Extra Payment will be admissible.
Supplying, installing, testing and commissioning in replacement of out door type HT feeder pillar box of size 100cmx80cmx50cm with aluminium insulated bus bar of size 500mmx50x10mm(03 Nos) suitable for 3 phase, front and back openable with locking arrangment both side and CPRI approved for capacity at 11000 volts, factory made is an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust/vermin proof mounted on angle iron frame of size 50x50x10mm & general construction confirming to IS:8623/93 complete all as specified and as directed. Note:- Grouting of panel 60cm above GL, embedded in cement concrete 1:2:4 (using 20 mm graded stone aggregate) up to 30 cm complete all as specified and as directed. Note : Drawing of Pillar box shall be got approved from Engineer-in-Charge before procurement.
Supply and fixing in replacement Air Circuit Breakers 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps, ultimate breaking capacity (Icu) of 50 KA complete all as specified and as directed.
Supply and laying broken stone of gauge 45 mm over installation complete all as specified and as directed.
Supplying and fixingin replacement of feeder pillar box out door type made out of MS sheet of 3.15 mm thick with alluminium busbar, duly powder coated & mounted on angle iron frame made out of size 50x50x6mm, 90 cm high consisting of the following accessories complete all as specified and as directed:- (i) MCCB TPN 415 volts 250 Amp. 36 KA - 01 Nos (for incoming) complete. (ii) MCCB TPN 415 volts 100Amp. 16 KA ---04 Nos (for outgoing) complete. (iii) MCCB TPN 415 volts 63 Amp. 16 KA --01 Nos (for outgoing) complete. (iv) LED Indicating lamp cluster type set of three colour in RED/BLUE/ GREEN - 01 Set complete. (v) MCB SPN 63 Amp -02 Nos complete. (vi) Grouting of panel 60cm above GL, embedded in cement concrete 1:2:4 using (20 mm graded stone aggregate) up to 30 cm complete. Note : Drawing of Pillar box shall be got approved from Engineer-in-Charge before procurement.
Supplying and fixing in replacement of feeder pillar box out door type made out of MS sheet of 3.15 mm thick with alluminium busbar, duly powder coated & mounted on angle iron frame made out of size 50x50x6mm, 90 cm high consisting of the following accessories and make as approved by GE from approved list:-:- (i) MCCB TPN 415 volts 200 Amp. 36 KA ---01 Nos (For incoming) complete. (ii) MCCB TPN 415 volts 100Amp. 16 KA ---04 Nos (For out going) complete. (iii) MCCB TPN 415 volts 63 Amp. 10 KA ---01 Nos (For out going) complete (iv) LED indicating lamp cluster type set of three colour in RED/BLUE/ GREEN - 01 Sets complete. (v) MCB SPN 63 Amp -02 Nos complete. (vi) Grouting of panel 60cm above GL, embedded in cement concrete 1:2:4 (using 20 mm graded stone aggregate) up to 30 cm complete. Note : Drawing of Pillar box shall be got approved from Engineer-in-Charge before procurement.
Ms Kamal Kant Agarwal
M/s DEVI DAYAL CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .