Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC 1090 GROUND FLOOR SECTOR 18 C CHANDIGARH | ₹17.4 L | L1 | Accepted-AOC Due to lower rates |
| 2 | L2₹17.4 LRejected-Finance | ₹17.4 L | L2 | Rejected-Finance Due to higher rates |
| 3 | Rejected-Technical H NO 238 SECTOR 41 D BADHERI CHANDIGARH | - | - | Rejected-Technical Rejected |
Tender Value
₹21.0 L
EMD Value
₹42,006
Closing Date
25 Feb 2026, 11:00 amClosed
EEPH Divn No. 3 Chd
EEPH Divn No. 3 Chd
Providing and fixing of Air Conditioners and allied works in the existing block and workshop extension block in CCET (Diploma Wing) Sector 26, Chandigarh
2026_CHD_90743_1
PH3/2026/70
Open Tender
Public Health Products
90 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹42,006
11 Mar 2026
19 Feb 2026
25 Feb 2026
19 Feb 2026
25 Feb 2026
19 Feb 2026
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
Inverter Type - Cooling Only
1.5 TR with 5 Star BEE Rating
Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoorunit (IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply . the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified.
2.0 TR with 3 Star BEE Rating (Minimum cooling capacity 6700 W)
Manufacturing, Supplying and fixing of MS stand ( Powder Coated ) for Outdoor Unit of Split Type / Cassette Type Air Conditioner including grouting complete to the satisfaction of EIC.
Providing and fixing of UPVC pipe of size 20mm Class 5 for condensate drain including cutting, jointing costing of solvent complete
Providing and fixing of 22 Guage soft/ hard copper piping 3/8" & 5/8" or as per OEM Specification, for liquid and sunction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing of original condition. the rate per metre includes cost of 1 metre each of both 3/8" & 5/8" with insulation and other works total line etc.
Providing and laying of Multicore flexible cable PVC Insulated with Bare Copper Conductor as per IS marked complete including making connection to the satisfaction of EIC Make : Havells, Polycab, Finolex or as per approved make list
2.5 sqmm x 3 Core
Providing and fixing of Voltage Stablizer suitable for 2.0 TR AC Unit 15 Ampere capacity working range 150 VAC to 285 VAC with low and high voltage cut off protection , built in thermal overload protection, digital / analog display for input / output voltage, wall mouted type, with metal cabinet complete of make V-Guard model VND 400 or equivalent model of Deol, Luminous, Microtech
Providing and fixing PVC Channel to cover copper pipe, drain pipe and wire in case of exposed in the wall size 100x50 mm
Supply installation Testing and Commissioning of surface mounted switch socket box including 3 pin top of rating 16Amp
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness EDSR 4.1.4
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral EDSR 2.10.5
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.43 MB
BOQ_110968.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid