Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹11.6 L+₹12,577.80 (1.10%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹12.5 L
EMD Value
₹25,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVISION OF EXTERNAL SUPPLY FOR OFFICER INSTITUTE AND TRANSIT FACILITY AT VIGYAN VIHAR, RAIPUR ROAD, UNDER GE (I) R N D DEHRADUN
2022_MES_531851_1
GE(I)RND/9135/E8/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEAL DEHRADUN
Class E Category b (ii) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹25,000
Yes
13 Aug 2022
18 Jun 2022
29 Jul 2022
18 Jun 2022
27 Jul 2022
2 Jul 2022
18 Jun 2022 - 2 Jul 2022
Amount
Supplying,erecting and fixing of steel tubular swaged pole 410 SP-55 (11 metre long),in true vertical position complete conforming to IS : 2713 (Part-I & III) 1980 with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with two coat of aluminum paint over and including one coat of red oxide primer complete, all as specified and directed. Note :- Earthwork, cement concrete in foundation, coping, cross arms will be measured and paid separately under relevant items of BOQ.
Supply and fixing of steel & iron items from poles i.e cross arms, bracing, supports, clamps and back plates etc. including nuts & bolts complete and Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer ccomplete, all as specified and directed.
Supply, fixing, commissioning & testing of distribution class lighting arrestor of rating 12 KV capacity and 10 KA NDC(Peak) confirming to to IEC-99.4 including brackets, clamps, bolts, nuts and washers complete, all as specified and directed.
Supply , fixing commissioning & testing of outdoor gang operated switch air break tilting type of current rating up to 200 Amps , triple pole each pole consisting of galvanized steel base. HT insulators as per IS, consisting of twelve insulator (3 insulators in each phase and one each for DO fuse), non ferrous knife and spray loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers adequate lenth of GI pipe for phase separation, adequate length of GI pipe 25 mm dia light grade,for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous part hot dripped galvanized and non ferrous heavily tinned to with stand weather and suitable for vertical mounting 11000 volt 200 Amp current rating complete, all as specified and directed.
Supply, fixing, commissioning & testing of out door transformer 160 KVA capacity copper wound, three phase, step-down hermatically sealed, 11000/433 Volts at no load, oil immersed naturally cooled, corrugated wall design with external coolling tubes/fins core type, Delta connection on primary (HV side) in accordance with vector group DY-11 with neutral brought on secondary (LV side) and having tappings at + 2.5, + 5.0%, + 7.5% be changed by means of hand operated "OFF LOAD" tap changer gear complete, mounted on suitable size of PCC plate form as per manufacturer NORMS, including testing and comprising with followings :- (a) HT bushing suitable for 11 KV complete with all accessories -03 nos. (b) LT bushing suitable for 1100 V complete with all accessories -04 nos. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with first fill dehydrating agent. (e) Expiosive vent. (f) Thermometer pocket on tank cover. (g) One number 100mm dial type thermometer, vapour pressure type, having range 0-120 degree centigrade with maximum reading pointer, Max. Temperature indicator and resting device. (h) Rating plate with terminal marking. (i) Two Nos, earting terminals on tank and cover to facilitable fixing of 32mm x6mm strip. (j) Oil level gauge. (k) Oil drain filter valve. (l) Lifting lugs. (m) Oil filter hole with cap/plug with connection complete. (n) Air release valve plug. (o) Four plain solid cast steel detachable rollers. (p) First fill of fresh trams former oil conforming to relevant IS and tested upto 40 KV dielectric strength complete, all as specified and directed. Note :- PCC Plate form will be measured and paid separately under relevant items of BOQ.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete, all as specified and directed.
M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete, all as specified and directed
M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above the starting point complete, all as specified and directed
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete, all as specified and directed (NOTE : Thickness after punning shall be measured for payment)
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made complete, all as specified and directed
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of Class LV, Type I, flat, size 250mm x 150mm x 40mm complete, all as specified and directed
Supplying, laying & jointing of GI water tubing, under mentioned bore, light grade pipe as in sleeving etc laid in trenches /road/ ducts etc complete, all as specified and directed. MAKE : TATA/JINDAL/TT SWASTIK
100 mm bore
80 mm bore
Supplying, Laying, testing and commissioning of XLPE insulated, PVC sheathed (heavy duty) armoured shielded cable with aluminium conductor for working voltage upto 11KV (Earthed) of size 3 core 120 sq mm ,conforming to IS 7098 Part-II amended upto date complete, having cross sectional area under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection with VCB/2 pole structure etc.complete, all as specified and directed. Make:Havells/CCI/ICL/GLOSTER/Incab/ Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, PCC cover,GI pipe and clamps for holding cables shall be measured and paid separately )
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor cable of sixe 120 sq mm complete, all as specified and directed
Supplying, Laying, testing and commissioning of XLPE insulated,IS 7098 (Part-I)-1988 marked screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100V grade cross section area of the under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection, with busbar/MCCB/DB's & testing complete, all as specified and directed Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, shall be measured and paid separately )
150 Sqmm 3½ core
70 Sqmm 3½ core
Supply, install, testing and commissioning of factory made LT cubical outdoor type panel CPRI approved made of 3.15 mm thick totally enclosed with front and rear opening hinged doors with projectedan raised platform of suitable size weather and water proof with necessary locking arrangement along with lugs, cable glands of various sizes for cable,danger notice connector for connecting multi cables located in cable chamber terminated form the switchergear and the nuts/ bolts etc used are to be made of rust proof material including as per IS :8623 aluminium bus bar 400 Amps for phase and 200 Amps for neutral with insulators suitable for three phase and capacity complete & powder coating necessary internal electric connection as required and provision of the following:- ( Make of LT Panel : L&T/ABB/SHALABH/ ADVANCE TRICOLITE ADLAC) INCOMING:- (a) MCCB 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity , 35/36 KA with adjustable thermal magnetic setting, Qty – 01 No.(Make:Legrand/Schnieder/Siemens) (b) Digital Ammeter 3 Phase AC 0 – 200 Amps, with 3 current transformer of suitable ratio and capacity Qty -01 No. (c) Indicating lamps LED type for three phases -R Y B of 3 Nos, (d) Digital Voltmeter 3 Phase AC 0 – 500 Volts.Qty -01 No. (e) Bus-bar chamber having 3 nos insulated aluminium bus-bar of 400Amps rating and one No. bus bar of 200 Amps rating of suitable shape and size. OUTGOING:- (a) MCCB 4 Pole, 100 Amps, 415 volts, 50 Hz 'C' Curve having breaking capacity 10 KA , with thermal magnetic protection unit and testing Complete - 03 Nos. Make:Legrand/Schnieder/ Siemens).
M&L for earthing complete for LT Panel/ Mechine Equipment with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 metres below ground level connected to galvanized iron strip 32x6 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed.
M&L for PCC 1:4:8 type (nominal mix) D-2 with 40 mm graded crushed stone aggregates as in foundation filling land mass concrete for poles and stay/installation paths & near feeder pillar/LT panel, including form work, fair finishing to exposed surface complete all as specified and as directed.
M&L for PCC 1:2:4 type (nominal mix) B-2 using 40 mm graded crushed stone aggregates as in plate-form coping of pole and the like complete including weather slightly rounded or chamfered angles and throaty includinf use of form work complete, all as specified and directed.
M&L for PCC 1:3:6 type (nominal mix) C-2 using 40 mm graded crushed stone aggregates as in foundation filling land mass concrete for pole and stay/ installation paths complete, all as specified and directed.
MAHADEV ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .