| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC M S CHANANA ENGINEERS CONTRACTORS AZAD CHOWK FEROZEPUR CANTT FEROZEPUR PUNJAB 152001 | FIROZEPUR | PUNJAB | 152001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.0 L+₹90,549 (6.43%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹21.4 L+₹7.3 L (51.9%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L3 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹34,500
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR/ MAINT OF SUMMER AND WINTER APPLIANCES AT MH JRC UNDER GE (EAST) JALANDHAR CANTT
2020_MES_387450_1
GE/JULL/ET-51/2020-21
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹34,500
Yes
1 Jan 2021
9 Nov 2020
11 Dec 2020
9 Nov 2020
9 Dec 2020
23 Nov 2020
60 days
Amount
Material and labour for servicing and maintenance of AC's split type of capacity 1/1.5/2.0 TR inner & outer unit of any make, cleaning of outdoor condenser unit by taking down, cleaning of condenser coil and fins with chemical solutions C-shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightening all electrical connections, and re-fixing outdoor unit, cleaning of indoor unit, cleaning of cooling coils with chemical solution C-shine or equivalent, washing of air filter, oiling and tightening of all nuts, bolts, replacement of condensed water flexible drain pipe etc complete all as specified and directed
Material and labour for servicing and maintenance of AC's window type of capacity 1.5/2.0 TR of any make, by taking down AC, cleaning of condenser coil and fins with chemical solution C-shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightening all electrical connections, cleaning of cooling coils with chemical solution C-shine or equivalent, washing of air filter, oiling and tightening of all nut, bolts etc complete all as directed. Note for Srl Item No. 1.00 & 2.00 : Contractor will have to complete the work before 15 Apr 2021 failing which penalty @ 2% of CA amount will be recovered from his dues
Material and labour for replacement of compressor sealed unit of capacity 1.5 TR unit suitable for air conditioners window mounted type including taking out old unserviceable compressor, cleaning, flushing, vaccumizing the system, re-charging of gas in adequate quantity, soldering, brazing of suction, discharge and charging line complete all as specified and directed. Make:- Kirloskar/ LG/ Toshiba/ Hitachi/ Gujral/ Carrier/ Tecumshah/ Usha Shri Ram.
All as per srl item No. 3.00 here-in-before but suitable for air conditioners of capacity 2.0 TR
Material and labour for replacement of compressor sealed unit suitable for air conditioner split type of capacity 1.5 TR in outdoor unit including taking out old unserviceable compressor, cleaning flushing, vaccumizing the system, recharging of gas in adequate quantity, soldering/ brazing of suction, discharge and charging line complete all as specified and directed. Make:- Kirloskar/ LG/ Toshiba/ Hitachi/ Gujral/ Carrier/ Tecumshah/ Usha Shri Ram.
All as per srl item No. 5.00 here-in-before but suitable for air conditioners of capacity 2.0 TR. Note for item No. 3.00 to 6.00 : Cost of wasted gas during charging shall be deemed to be included in the item rate. Nothing shall be paid extra on this account.
Supply, replacement, connecting and testing of double shaft motor 1/5 HP blower motor with blades 240 volts single phase for window type AC 1.5 TR as per existing type and size complete all as directed. Make: Khaitan/ Universal/ CG./ Carrier/ Voltas/ Sidwal.
Supply, replacement, connecting and testing of double shaft blower motor with blades 240 volts, single phase suitable for window type AC 2 TR as per existing type and size complete all as directed. Make: Khaitan/ Universal/ CG./ Carrier/ Voltas/ Sidwal.
Supply, replacement, connecting and testing of condenser blower motor with blades suitable for 1.0/1.5 TR split AC 240 volts single phase, as per existing type and size complete all as directed. Make: Khaitan/ Universal/ CG./ Carrier/ Voltas/ Sidwal.
Supply, replacement, connecting and testing of condenser blower motor with blades suitable for 2 TR split AC 240 volts single phase, as per existing type and size complete all as directed. Make: Khaitan/ Universal/ CG./ Carrier/ Voltas/ Sidwal.
Supply, replacement, connecting and testing of cooling blower motor suitable for 1.0/1.5/2.0 TR split AC 240 volts single phase, as per existing type and size complete all as specified and directed. Make: Khaitan/ Universal/ CG./ Carrier/ Voltas/ Sidwal.
Supply and replacement of blower drum as per sample suitable for 1.0/1.5 /2.0 TR split AC as per existing type and size complete all as directed. Make: Khaitan/ Universal/ CG./ Carrier/Voltas
Supply and replacement of blower drum as per sample suitable for 1.5/2 TR Window AC as per existing type and size complete all as directed. Make: Khaitan/ Universal/ CG./ Carrier/ Voltas
Supply and fixing in replacement of temperature sensor as per existing type and size suitable for 1.0/1.5/2 TR Window/ Split AC complete all as specified and directed..
Supply and fixing in replacement of starting/running capacitor conforming to IS specification suitable for 1.0/1.5/2 TR Window/ Split AC complete all as specified and directed.. Make: Havells/ Unistar/ Asian/ EPCOS/ Sarda
Supply and fixing in replacement single pole contactor of rating 32 Amps with magnetic coil 208-240 VAC, 50 Hz suitable for split AC's of capacity 1.0/1.5/2 TR complete all as specified and directed. Make: Schneider/L&T/C&S/BCH
Material & labour/ charging of refrigerant gas in window type AC 1.5 Ton capacity including vaccumizing, leakage test and rectification of leakages etc complete all as specified and directed.
All as per item No 17.00 here-in-before but of capacity 2.0 TR
All as per item No 17.00 here-in-before but for split type AC of capacity 1.0/1.5 TR
All as per item No 17.00 here-in-before but for split type AC of capacity 2.0 TR
Supply & fixing in replacement complete indoor unit of split type AC of capacity 1.0 Ton including cooling coils, PCB plate and display, remote control, cooling fan motor with blade, blower drum, complete with all accessories suitable for AC's of make Voltas/ Blue Star/ Samsung/ L.G complete including taking out old unit including cutting, brazing and testing all as specified and directed.
All as per item No 21.00 here-in-before but for capacity 1.5 Ton.
All as per item No 21.00 here-in-before but for capacity 2.0 Ton.
Supply & fixing in replacement complete outdoor unit of split type AC of capacity 1.0 Ton including condensor coils copper with colling fins, PCB plate and display, remote control, cooling fan motor with blade, including compressor, complete with all accessories suitable for AC's of make Voltas/ Blue Star/ Samsung/ L.G complete including taking out old unit including cutting, brazing and testing all as specified and directed.
All as per item No 24.00 here-in-before but for capacity 1.5 Ton.
All as per item No 24.00 here-in-before but for capacity 2.0 Ton.
Supply & fixing in replacement PCB remote plate DC operation suitable for hot and cold operation of AC split type 1.0/1.5 /2 TR of make LG/ Voltas/ Sidwal/ Carrier/ Blue Star, complete with remote all as specified and directed..
Supply & fixing in replacement PCB remote plate DC operation suitable for hot and cold operation of AC Window type 1.5 /2 TR of make LG/ Voltas/ Sidwal/ Carrier/ Blue Star, complete with remote all as specified and directed.
Supply and fixing in replacement white modular motor starter for AC's, upto 32 Amps, 250V AC, two module including metal flush mounting box and white cover plate including taking down existing AC plug top box etc complete all as specified and directed
Supply and fixing in repairs/replacement single pole & neutral sheet metal enclosure with 2 pin plug top and earth plug socket complete with MCB SPN, 32 A, 240 volts 10 KA all as specified and directed
Supply & fixing in replacement of outer body of AC window type of standard size made of 1.6mm thick GI sheet, suitable for AC of capacity 1.5/2.0 TR of make LG/ Voltas/ Sidwal/ Carrier/ Blue star as per site requirement and as specified and directed.
Supply and fixing in replacement of copper pipe for suction/ discharge line of dia 12.7mm with thickness 0.71mm (heavy duty) including heavy duty insulation with wrapping with packing brown tape suitable for AC split type of capacity 1.5/2.0 TR including cutting and soldering, brazing etc complete all as specified and directed
All as per Srl item No. 32.00 here-in-before but for copper pipe of dia 6.35mm and thickness 0.61mm
All as per Srl item No. 32.00 here-in-before but for copper pipe of dia 5/8".
All as per Srl item No. 32.00 here-in-before but for copper pipe of dia 3/8".
Supply & fixing in replacement front grill suitable for AC window mounted type of capacity 1.5/2.0 TR all as per existing type and size complete all as specified and as directed.
Supply and fixing in repair evaporative coil made out of copper pipe and fins suitable for AC window mounted type of capacity 1.5 TR all as per existing type and size including cutting soldering and testing complete all as specified.
All as per item No 37.00 here-in-before but for split AC 1.0/1.5 TR
All as per item No 37.00 here-in-before but for split AC 2 TR
Supply & fixing in repair capillary copper (heavy duty) of size 1/64" suitable for AC window/ Split type of capacity 1.5/2 TR including cutting, soldering, brazing etc complete all as specified and directed.
Supply and fixing in repair reversible valve 4 way with plunger AC 200/240 volts 50 c/s as per existing make and type suitable for AC split/window type of capacity 1.5 TR including repair/ modification to remote plate, cutting, soldering, brazing complete including charging if gas required to maintain the required pressure complete all as specified and directed. Note: Cost of all modification required including chargers in wiring connections and gas cycle system are deemed to be included in item rate nothing shall be paid extra.
Supply & fixing in replacement of voltage stabilizer copper wounded for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 05 KVA complete all as specified and directed. Makes: V-Guard/Blue Star/ Logicstat.
All as per item No. 42.00 here-in-before but for 4 KVA
All as per item No. 42.00 here-in-before but for 3 KVA
All as per item No. 42.00 here-in-before but for 02 KVA
Material and labour PVC insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 70/0.0076, ISI marked complete all as specified and directed.
Material and labour in replacement PVC insulated and sheathed, round flexible wire with multi stranded copper conductor wire of size 3 core, 2.5 Sqmm, ISI marked complete all as specified and directed
Material and labour in replacement PVC insulated and sheathed, round flexible wire with multi stranded copper conductor wire of size 3 core, 4 Sqmm, ISI marked complete all as specified and directed
Taking down old unserviceable sealed compressor and supply & fixing of new compressor sealed unit suitable for water cooler 150/150 Ltrs capacity including cleaning, vaccumizing, gas charging of adequate quantity and testing on load complete all as specified and directed. Make: USHA / Sriram /Emerson / Kirloskar/ Carrier/ Tecumshah.
All as per description of Srl item No 49.00 here-in-before but sealed unit compressor suitable for water cooler capacity 60/120 Ltrs
All as per description of Srl item No 49.00 here-in-before but sealed unit compressor suitable for water cooler capacity 40/80 Ltrs
Material and labour for repair to body of water cooler/ refrigerator/ deep freezers of any capacity by fixing of MS sheet angle iron/ MS flat etc all as per existing sizes including cutting, welding, riveting, drilling, bending to shape etc, at site including grinding, finishing and applying of one coat of primer complete all as specified and as directed. Note : Transportation of equipments/ T&P required at site will be responsibility of the contractor, nothing shall be paid extra on this account.
Supply and replacement of water tap brass CP with inner/outer threads push type or with rotary knob of size 15 mm dia as per existing type and size complete all as specified and directed.
Supply and fixing in repalcement of thermostat switch suitable for water coolers complete all as specified and directed. Make : Danfoss/ Renutrol/ Indfoss or equivalent
Supply and fixing in repalcement of starting relay suitable for water coolers of capacity 150/120/80 Ltrs complete all as specified and directed. Make :- Danfoss/Renutrol/ Indfoss or equivalent.
Supply & fixing in replacement of starting/running capacitor suitable for water coolers 150/120/80 ltrs complete all as specified and directed. Make :- USHA/UNIVERSAL/ HAVELLS/EPCOS/ sarda or equivalent.
Supply and fixing in replacement of overload protector suitable for water cooler of capacity 150/120/80 Ltrs complete all as specified and directed. Make :- Danfoss/Renutrol/ Indfoss or equivalent.
Supply & fixing in replacement fin type condenser with copper pipes suitable for water cooler of capacity 60/120 Ltr as per existing type and size including cutting, soldering/ brazing etc complete all as specified and directed.
All as per item No. 58.00 here-in-before but of capacity 40/80 Ltrs.
All as per item No. 58.00 here-in-before but of capacity 150/150 Ltrs.
Taking down old and unserviceable sealed compressor and supply and fixing new sealed compressor unit for refrigerator of capacity 230/310/360 Ltrs including cleaning, vaccumizing, gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge and charging line complete all as specified and directed. Make: Kirloskar/ LG/ Voltas/ Godrej/ Hitachi/ Toshiba/ Carrier.
All as per item No 61.00 above but for Refg of capacity 165/175/185/180/215 Ltr .
Taking down old and unserviceable sealed compressor and supply and fixing new sealed compressor unit for deep freezer of capacity 405 Ltrs including cleaning, vaccumizing, gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge and charging line complete all as specified and directed. Make: Kirloskar/ LG/ Voltas/ Godrej/ Hitachi/ Toshiba/ Carrier.
All as per item No. 63.00 but for deep freezer of capacity of 200Ltrs.
Supply and fixing of evaporative coil (cooling coil ) of refrigerators of capacity 230/310/360 Ltrs as per existing type and size including cutting, taking out to old coil, brazing/ soldering and testing complete all as specified and directed.
All as per item No 65.00 above but for refrigerator of capacity 165/175/185/180/215 Ltr.
Supply and fixing magnetic door gasket suitable for refrigerator of capacity 165 to 360 Ltrs as per existing type and size complete all as specified and directed.
Supply and fixing freezer door suitable for refrigerator of capacity 165 to 360 Ltrs as per existing type and size complete all as specified and directed.
Supply and fixing Crisper tray for refrigerator of capacity 165 to 360 Ltrs as per existing type and size complete all as specified and directed.
Supply and fixing chiller tray for refrigerator of capacity 165 to 360 ltrs as per existing type and size complete all as specified and directed.
Supply and fixing thermostat switch suitable for refrigerator of capacity 165 to 310 Ltrs as per existing size and type complete all as specified and directed. Make :- Danfoss/ Renutol/ Indfoss or equivalent.
Supply and fixing of starting relay with over load protector kit complete as per existing size and type complete all as specified and directed. Make :- Danfoss/ Renutol/ Indfoss or equivalent.
Material & labour for charging refrigerant gas of existing type in refrigerator of capacity 165 to 360 ltrs including vaccumizing, leakage test and rectification of leakage etc complete all as specified and directed.
All as per item No. 73.00 but for deep freezer of capacity 200/405 Ltrs.
Supply and fixing in replacement cooling motor with fan, 100mm sweep suitable to operative on AC, 220/240 volts, 50 c/s complete with frame square all as per existing size/type suitable for deep freezers and water coolers all as specified and directed
Material and labour for de-scaling of collector unit and piping complete and testing of solar water heaters of capacity 300 LPD complete all as specified and directed.
Supply and fixing in repair of solar water heating element 3 KW Single phase, 230 Volts, ISI marked as per existing type and size complete all as specified & directed.
Supply and fixing thermostat switch suitable for solar water heater of capacity 300 LPD all as per specified ISI marked as per existing type and size complete all as specified & directed.
Supply and fixing in repair heat collector glass size 80"x40" suitable for solar water heaters of capacity 300 LPD as per existing type and thickness complete all as specified & directed
Material and labour for replacement of copper pipe with insulation of size 20mm dia in collector of solar water heaters of capacity 300 LPD including cutting, soldering and testing complete all as specified and directed.
Material and labour re-painting of desert cooler internally and externally including removing of old paint and preparing surfaces for repainting and applying two coats of synthetic enamel paint by using spray gun and writing of MES/ GE (E) JRC complete all as specified and directed.
Supply and fixing in repair front air grill of desert cooler complete as per existing type and size all as specified and directed.
Supply & replacement of submersible water pump of capacity 18 watt, single phase, 220 V for desert cooler with switch/ wiring, PVC water pipe with junctions complete for 01 desert cooler etc complete all as specified and directed. Make: Universal/ Khaitan /CG
Supply and replacement Wood wool pad at site for desert cooler any size / cap complete all as specified and directed.
Supply & fixing in repairs Starting capacitor 2.5/3.15/4 mfd heavy duty suitable for desert cooler/ ceiling fan complete all as specified and directed. Make: Usha/ Tibeon/ Keltron/ Asian/ Havells/ EPCOS or equivalent.
Supply and fixing in replacement top plug 6 Amp complete all as specified and directed. Make : Anchor/ Havells/ Cona/ SSK
Material and labour for painting of ceiling fans 1200mm sweep including blades issued from MES store complete (as per existing colour), with synthetic enameled paint by spraying including filling cavities with filler one coat after cleaning all dust etc including rewinding of stator complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), and quick dry type varnishing including replacement of insulated material and greasing complete and depositing in MES store after testing of any make and type complete all as specified and directed. Note : Transportation of unserviceable fans from MES store yard to workshop and workshop to MES store yard shall be carried out by contractor without any extra cost.
All as per item No. 88.00 here-in-before but for ceiling fan of 1400mm sweep.
All as per item No. 88.00 here-in-before but for exhaust fan of 300mm sweep.
All as per item No. 88.00 here-in-before but for exhaust fan of 380mm sweep.
All as per item No. 88.00 here-in-before but for exhaust fan of 450mm sweep.
All as per item No. 88.00 here-in-before but for PVC exhaust fan of 250/300mm sweep.
Material and labour for rewinding of wall/cabin mounted fan stator complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans) and quick dry type varnishing including replacement of insulated material and oiling of the following size of wall fans of size 300/400mm sweep of any type and make and testing complete and depositing in MES store all as specified and directed.
Material and labour for replacement of ball bearing of existing type and size make SKF/ TATA/ NBC in ceiling fan of any make of 1200mm/ 1400mm sweep including greasing complete all as specified and directed
All as per item No. 95.00 here-in-before but of exhaust fan of 300/380/450mm sweep.
Material and labour for replacement of old worn out GM bushes as per existing size in ceiling fans of any make of size 1200/1400mm sweep including greasing complete all as specified and directed
All as per item No. 97.00 here-in-before but of exhaust fan of 300/380/450mm sweep.
Supply and fixing in replacement for CPVC pipe for drain pipe of ACs condensed water fixed complete to walls, ceilings or in floors etc. of size 40mm dia alongwith Sockets, Tees, Bends, Elbows, Wall Clamps, necessary joining material other accessories required for fixing of pipe with wall/ floor complete all as specified and directed
All as per item No. 99.00 here-in-before but of size 25mm dia.
Supply and fixing in replacement for PVC pipe for drain pipe of ACs condensed water fixed complete to walls, ceilings or in floors etc. of size 75mm dia, class-2 alongwith sockets, tees, bends, elbow, wall clamps, necessary joining material other accessories required for fixing of pipe with wall/ floor all as specified and directed
Taking down existing split AC 1.5/2.0 TR indoor unit and outdoor unit complete by disconnecting refrigerant suction and discharge lines, opening nuts and bolts taking out brackets of indoor and outdoor unit from walls, taking out voltage stabilizer form wall, taking indoor unit, outdoor unit and voltage stabilizer to another department within Military Hospital's premises without damaging the AC's all as specified and directed
Fixing of split AC's 1.5/2.0 TR indoor and outdoor unit with walls by fixing bracket with wall and fixing indoor unit and outdoor unit with brackets, tightening of nuts bolts, soldering/ brazing of suction, discharge and charging line, fixing of voltage stabilizer with wall and making electrical connections of indoor to outdoor units and to voltage stabilizer complete all as specified and directed
Supply and fixing in replacement brackets for fixing split AC 1.5/2.0 TR indoor and outdoor unit with walls made of MS duly powder coated company made with 08 Nos bolts, nuts and washers and 04 Nos of fasteners complete all as specified and directed
Material and labour for shifting of window type AC 1.5/2.0 TR by taking out AC from one room and shifting it to another room/ department within Military Hospital's premises and fixing it at place where directed by department all as specified and directed Note for Srl item No. 103.00 to 105.00 (a) Contractor will have to complete the work within one month from the date of work order failing which penalty @ 2% of CA amount will be recovered from his dues. (b) Contractor will have to deploy one highly skilled AC and Refrigerant mechanic and one helper with mobile for attending complaints from 0900 Hrs to 0500 Hrs and their attendance record will be maintained by the department. (c) Complaints record will be maintained by the department
Material and labour in repair sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 2.5 Sqmm PVC insulated with green insulation complete all as specified and directed. Note: Two runs of cable 4.0 Sqmm, one run of cable 2.5 Sqmm and one run of PVC conduit will be measured as one unit RM.
Material and labour in repair sub main wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed. Note: Two runs of cable 6.0 Sqmm, one run of cable 4.0 Sqmm and one run of PVC conduit will be measured as one unit RM.
Supply and fixing in replacement geyser inner water tank S/S or copper suitable for Geyser Capacity 50 Ltrs as per existing shape and type complete all as specified & directed.
Supply and fixing in replacement geyser inner water tank S/S or copper suitable for Geyser Capacity 25 Ltrs as per existing shape and type complete all as specified & directed.
Supply & fixing in replacement geyser assembly brass C P type 9 hole as per existing type and size complete all as specified & directed.
Supply & fixing in replacement geyser assembly brass C P type 6 hole as per existing type and size complete all as specified & directed.
Supply & fixing in replacement geyser assembly brass C P type 8 hole as per existing type and size complete all as specified & directed.
Supply and fixing in repairs geyser heating element triangle/ cup type 1.5/ 2.0 KW complete all as specified and directed
Supply and fixing in repairs geyser thermostat adjustable type suitable for geyser 25/35/50 Ltr capacity complete all as specified and directed
Supply and fixing in repairs PVC connection suitable for geysers 450mm long complete all as specified and directed
Attending complaints for unserviceable split/ window AC's of (any size/ capacity), Refrigerators, Deep Freezers, Desert Coolers, Geysers, Solar water Heaters, Water coolers, ceiling fans, exhaust fans, pedestal fans, leakage of condensed water pipes of AC's of any size/ capacity including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections, nuts, bolts screws, MCBs etc as required to make the item function during 0900 Hrs to 1700 Hrs by deploying highly skilled AC and Refrigerant mechanic and one helper (having mobile phone) including necessary T&P complete all as specified and directed. Note : (a) Number of complaints may vary day to day and shall be on required basis. contractor shall quote their rates accordingly. (b) In case of failure on the part of contractor for attending complaints a penalty shall be imposed @ Rs. 200/- per complaints per day and will be recovered from his dues
M&L for servicing and maintenance of mortuary cabinet AC unit comprising of 04 separate cabinets, cleaning of condenser unit by taking down, cleaning of condenser coil and fins with chemical solutions C-shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightening all electrical connections, and re-fixing outdoor unit, cleaning of cooling coils with chemical solution c-shine or equivalent, washing of air filter, oiling and tightening of all nuts, bolts, replacement of condensed water flexible drain pipe, cleaning of mortuary cabinets, replacements of hinged doors 04 Nos of cabinets, greasing of sliders etc complete all as specified and directed.
J.K & Company
CHOUDHARY AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .