Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAdmitted-Fee/PreQual/Technical/Finance | ₹8.0 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹8.2 L+₹18,632.45 (2.32%)Admitted-Fee/PreQual/Technical/Finance | ₹8.2 L+₹18,632.45 (2.32%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹8.5 L+₹44,238.45 (5.51%)Admitted-Fee/PreQual/Technical/Finance | ₹8.5 L+₹44,238.45 (5.51%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | A K R Agency L3 | MSM INFRATECH L2 | Sabareesan L1 |
|---|---|---|---|---|---|---|
| 1.00 | Earth work excavation and refilling for pipe line works
Having bed width of 1.25m and below on linear measurement basis | 225 | Rm | 600 ₹1,35,000 | 282 ₹63,450 | 155.52 ₹34,992 Lowest |
| 2.00 | Supply and fixing of HDPE 110 MM DIA WD-M0187 using in Waste water source including all material and labour cost etc.Complete as per standard specification.TWAD P.No:41. | 225 | Rm | 400 ₹90,000 | 510 ₹1,14,750 | 353.12 ₹79,452 Lowest |
| 3.00 | Lowering of HDPE 90 MM DIAs and specials in the trenches and laying to proper grade and
alignment and as directed by the TWAD Officers TWAD P.No:167. | 225 | Rm | 300 ₹67,500 | 20 ₹4,500 | 19.16 ₹4,311 Lowest |
| 4.00 | Jointing the HDPE 110 MM DIA pipes and specials with molten lead and Yarn including caulking the joints. (Including cost of jointing materials) TWAD P.No:169. | 38 | Nos | 400 ₹15,200 | 350 ₹13,300 | 218.35 ₹8,297.3 Lowest |
| 5.00 | Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump, wear resistance with submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smooth and designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type, single vane / multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should be provided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be at least 30% above the operating speed.Pumps should have double bearings between the pump & motor. The bearings life shall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic coupling device including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chain conforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low duty pumpsets. Casing and impeller should be of CI Gr. FG 260:IS210 more preferably with hardened impeller.Shaft should be of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible motor shall be operated with 3ph, 415 V (+or– 10%), 50Hz (+or-5 %) dry induction type. Motor shall be capable of giving rated output without reduction in the expected life span when operated continuously. The rotating assembly shall be dynamically balanced as per standards. The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta or ATS starting under any circumstances .The motor shall be suitable for full voltage star delta / ATS starting. The locked rotor current of the motor shall not exceed 600% of full load current unless otherwise specified. Motor shall be designed to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction of rotation. The motor vibration shall be within the limit specified in applicable standards. Motor should be of IE2, explosion proof compatible for VFD operation together with star-Delta /ATS starter, protection against increase in stator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminal box shall be provided and to be suitably interlocked with the control panel for tripping the pump in case of increase in temperature beyond set limit. Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691.Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with power cable of PVC insulated and PVC sheathed,copper, flexible, round type with required conductor size and number of cores as per starting method and of specified length for continuous use under water and air. The control cable of PVC insulated, PVC sheathed, flexible for stator winding temperature sensor 3core x 1.5 sq.mm copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall be provided. Motor shall be supplied with 10m of round submersible copper cable of suitable size.
The non clog submersible pumpset shall be provided with suitable starter control panel having
all protections as mentioned above. (upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta
Panel and beyond 25 HP shall be ATS) | 1 | Nos | 4,10,000 ₹4,10,000 Lowest | 5,00,000 ₹5,00,000 | 5,53,157.49 ₹5,53,157.49 |
| 6.00sub Total | ||||||
| 7.00 | GST18% | 1 | Nos | 1,29,186 ₹1,29,186 | 1,25,280 ₹1,25,280 | 1,22,437.76 ₹1,22,437.76 Lowest |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
17 Sept 2026, 11:00 amClosed
Member Secretary
Chennai Rivers Restoration Trust, Chennai - 600028
Laying of Waste Water pipe line and installation of pumping system from the Education centre waste water sump to site office waste water collection chamber
2026_CRRT_701390_1
CRRT/Infra/Tender/01/2026
Open Tender
Pipe Laying Works
Works
Chennai Rivers Restoration Trust
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹9,000
Yes
17 Sept 2026
3 Sept 2026
17 Sept 2026
3 Sept 2026
17 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work excavation and refilling for pipe line works
Having bed width of 1.25m and below on linear measurement basis | 225 | Rm | - | - |
| 2 | Supply and fixing of HDPE 110 MM DIA WD-M0187 using in Waste water source including all material and labour cost etc.Complete as per standard specification.TWAD P.No:41. | 225 | Rm | - | - |
| 3 | Lowering of HDPE 90 MM DIAs and specials in the trenches and laying to proper grade and
alignment and as directed by the TWAD Officers TWAD P.No:167. | 225 | Rm | - | - |
| 4 | Jointing the HDPE 110 MM DIA pipes and specials with molten lead and Yarn including caulking the joints. (Including cost of jointing materials) TWAD P.No:169. | 38 | Nos | - | - |
| 5 | Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump, wear resistance with submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smooth and designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type, single vane / multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should be provided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be at least 30% above the operating speed.Pumps should have double bearings between the pump & motor. The bearings life shall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic coupling device including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chain conforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low duty pumpsets. Casing and impeller should be of CI Gr. FG 260:IS210 more preferably with hardened impeller.Shaft should be of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible motor shall be operated with 3ph, 415 V (+or– 10%), 50Hz (+or-5 %) dry induction type. Motor shall be capable of giving rated output without reduction in the expected life span when operated continuously. The rotating assembly shall be dynamically balanced as per standards. The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta or ATS starting under any circumstances .The motor shall be suitable for full voltage star delta / ATS starting. The locked rotor current of the motor shall not exceed 600% of full load current unless otherwise specified. Motor shall be designed to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction of rotation. The motor vibration shall be within the limit specified in applicable standards. Motor should be of IE2, explosion proof compatible for VFD operation together with star-Delta /ATS starter, protection against increase in stator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminal box shall be provided and to be suitably interlocked with the control panel for tripping the pump in case of increase in temperature beyond set limit. Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691.Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with power cable of PVC insulated and PVC sheathed,copper, flexible, round type with required conductor size and number of cores as per starting method and of specified length for continuous use under water and air. The control cable of PVC insulated, PVC sheathed, flexible for stator winding temperature sensor 3core x 1.5 sq.mm copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall be provided. Motor shall be supplied with 10m of round submersible copper cable of suitable size.
The non clog submersible pumpset shall be provided with suitable starter control panel having
all protections as mentioned above. (upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta
Panel and beyond 25 HP shall be ATS) | 1 | Nos | - | - |
| 6 | sub Total | - | - | - | - |
| 7 | GST18% | 1 | Nos | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_843136.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .