| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC D 2 32 FIRST FLOOR KH NO 28 1 KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.4 L+₹16,961 (0.98%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹18.1 L+₹80,146.90 (4.64%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹18.1 L+₹82,765 (4.79%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹18.3 L+₹1.0 L (6.02%)Rejected-Finance 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
18 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
WELCOME MAINT AND ALLIED SERVICES IN H TYPE OFFRS MD ACCN AT SHANKAR VIHAR UNDER AGE B/R-II AND AGE E/M OF GE (SOUTH) DELHI CANTT-10
2023_MES_621939_2
GE/DS-62/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹85,000
Yes
15 Dec 2023
28 Oct 2023
20 Nov 2023
28 Oct 2023
18 Nov 2023
4 Nov 2023
Amount
Please refer Notes after Srl item No.96 before quoting the rates
M&L for prepartion of old treated/painted wall surface by washing down, rubbing and stopping including brooming down or steel wire brushing scrapping down smoke soot, moulds moss and efforescent salts and trading oil and greasy spots thereafter filling of holes and cracks with birla wall care putty to obtain an even and smooth wall surface and applying one coat of oil bound distemper on wall surface including scaffolding arrangement, trestles, ladders complete all as specified and as directed.
All as per Srl item No.2 above, but two coats of oil bound distemper, complete all as specified and as directed.
All as per Srl item No.2 above, but one coat of white wash on ceiling complete all as specified and as directed.
M&L for preparation of old plastered surfaces of wall thereafter filling of holes and cracks with wall care putty to obtain an even and smooth wall surface and applying one coat of white wash alongwith including scaffolding arrangement, trestles, ladders complete all as specified and as directed.
All as per Srl item No.5 above, but two coat of white wash on wall surface, complete all as specified and as directed.
M&L for complete removal of Existing Treatment and applying two coats of oil bound distemper over and including one coat wall care putty complete all as specified and as directed.
M&L for preparation of old plastered surfaces on external wall/ceiling, applying a coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance eterior paint of required shade (Company Depot Tinted) complete all as specified and as directed.
M&L for Preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel of any description over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel of any description over 10cm width or grith and applying one coat of aluminum paint, complete all as specified and as directed.
M&L for complete removal of existing treatment from internal surfaces of walls or a part thereof (In Patches ), area exe 1.00 Sqm but not exceeding 3.00 Sqm, which is damage due to seepage or any other reason & preparing and levelling the disturbed surfaces by using wall care putty to obtain even and smooth wall surfaces of that portion and using sand paper and than applying two coats of oil bound distemper over a coat of primer, including scaffolding arrangement, trestles, ladders complete all as specified and as directed.
M&L for complete removal of existing treatment from internal surfaces of walls or a part thereof (In Patches), area exceeding 3.00 Sqm but n.exc 5.00 Sqm, which is damage due to seepage or any other reason & preparing and levelling the disturbed surfaces by using wall care putty to obtain even and smooth wall surfaces of that portion and using sand paper and than applying two coats of oil bound distemper over a coat of primer,including scaffolding arrangement, trestles, ladders complete all as specified and as directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 5mm thick rendering in CM 1:3 on ceiling and finished fair even and smooth without using extra cement complete all as specified and as directed.
M&L for preperation of old decorated surfaces and applying one coat of cement base paint on wall etc. complete all as specified and as directed.
M&L for preparing of new plastered or unplastered surfaces of ceiling and applying three coats of White wash complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls applying two coat cement base paint complete all as specified and as directed.
Preparation of newly plastered surface of walls and apply three coats of white wash complete all as specified and as directed.
M&L for Preparing new plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over and including one coat of white putty on whole surface complete all as specified and as directed.
Hacking out old broken glass any thickness size and quality from wooden/steel frames etc. complete all as specified and as directed.
S&F sheet glass ordinary quality, 3 mm thick and glazing with oil putty in square n. exc. 0.50 Sqm in each pane complete all as specified and as directed.
S&F 3 mm figured glass, pin head type and glazed with oil putty in sqm n.exc 0.50 Sqm in each pane complete all as specified and as directed.
S&F in repairs SS curtain rod of 25 mm dia, with fixing brackets, side knobs etc. (SS/any pattern) complete all as specified and as directed.
S&F in repairs corner sheet glass shelf assemble consisting of 5.5mm thick sheet glass shelf with chromium plated bracket guard and railing complete all as specified and as directed. Make prayag cat No BEA 44 or equivalent
S&F in repairs SS toilet paper holder complete all as specified and as directed.
S&F in repairs of plastic WC seat cover white/off white closed pattern with flat bottom end cover and mild steel CP hinging device complete all as specified and as directed.
S&F in repairs CP health faucet alongwith 1.00 to 1.50 meter good quality SS flexible connection pipe suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 litre capacity complete all as specified and as directed. Make : Prayag/Cera/Commander
S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), including connecting to drain (or outgoing pipe), fix with white cement, white/ off white complete all as specified and as directed. Make : Hindware/Parryware/Cera
S&F in repairs vitreous china wash hand basin of size 550x400mm, white flat back, including waste coupling of PTMT 32 mm and waste pipe, 02 no of bracket and bolt complete all as specified and as directed. Make : Hindware/Parryware/Cera.
S&F in repairs sink mixing valve 15mm dia, Hot and Cold CP brass fancy including joints to steel pipe or unions, including fittings, complete all as specified and as directed.
S&F in repairs mixing valve 15mm dia, Hot and Cold CP brass fancy including joints to steel pipe or unions for centre hole wash hand basin including fittings complete all as specified and as directed.
S&F in repairs wall mixing valve Hot and Cold water Screwed Down for iron pipe 15mm dia CP brass fancy including joints to steel pipe or unions , including fittings for complete all as specified and as directed.
S&F in repairs Brass chromium plated shower rose 125mm size with arm complete all as specified and as directed.
S&F in repairs CP waste coupling 32/40 mm dia suitable for wash hand basin or kitchen sink complete all as specified and as directed.
S& F in repairs staianless plate rack made of 0.8 mm thick stainless steel sheet of size 750 mm x 900 mm x 210mm consisting of 3 shelf for bowls and one shelf for keeping six nos of big utensil and seven nos of small utensils divided by 10 mm dia stainless steel hollow pipe @ 60 mm centre to centre or as per drg and sample kept in GE"s office complete all as specified and as directed.
S&F in repairs cabinet mirror size 400x500 mm complete all as specified and as directed.
S&F In repairs 40/50 mm dia cup bord knobs fixed with nut ,screw and washer of aluminum complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premices complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surfaces 300x200x7mm/450x300x7mm thick set and jointed in cement slurry and pointed in white or coloured cement to match laid over & including 15mm thick cement mortar 1:4 complete all as specified and as directed.
M&L for Virified Ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. laid over and including 15mm thick cement mortar screed bed of CM (1:6) , set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile, complete all as specified and as directed.
M&L for Virified Ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. over and including 10 mm thick CM (1:4), set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile complete all as specified and as directed.
M&L for Non skid ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.11 sqm not exceeding 0.18, in floors etc. laid over and including 15mm thick cement mortar screed bed of CM (1:6), set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile complete all as specified and as directed.
M&L for Non skid ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.11 sqm not exceeding 0.18, in skirting etc. over and including 10 mm thick CM (1:4), set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile complete all as specified and as directed.
Disconnectiong existing tanks of capacity exc 500 & not exc 1000 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position including cleaning and removing all the scale and dirt, etc from tank and from months of circulating pipes etc. complete all as specified and as directed.
S&F in repairs for stainless steel door stopper 150mm long with double legged rubber bushes at the end complete all as specified and as directed.
S&F in repairs 4.8 mm thick sheet glass ordinary quality and glazing with Al glazing clips& EPDM beading in square exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for running welding in repairs including cleaning and preparing surfaces for welding thickness of metal to be welded not exc 6mm such as MS butt hinges to MS frame, broken steel windows or ventilators, iron doors and similar work complete all as specified and as directed.
Dismantling of stone slab and tiles laid bedded and pointed in any mortar of any discription or thickness in floors complete all as specified and as directed.
S&F Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including grinding and polishing as in cooking plateform complete all as specified and as directed.
Rounding to edges of stone slabs one edge such as in steps cooking platform and other similar situations complete all as specified and as directed.
S&F in repairs switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F in repairs Socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and as directed.
S&F in repairs switch piano type 15/16 Amps SP one way complete all as specified and as directed.
S&F in repairs universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and as directed.
S&F in repairs switch socket combination 5-in-1, 6/16 Amps flush type complete all as specified and as directed.
S&F in repairs switch socket combination 2-in-1, 6 Amps flush type including PVC gang box complete all as specified and as directed.
S&F in repairs switch socket combination 5-in-1, 6/16 Amps flush type, including PVC gang box complete all as specified and as directed.
S&F in repairs lamp holder Angle/Batten type bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repairs Electric Bell (Buzzer) AC, 230 volts single phase complete all as specified and as directed.
S&F in repairs Bell Electric Ding Dong type 230 volts single phase complete all as specified and as directed.
S&F in repairs old unserviceable plug top 15/16 Amps for Geyser complete all as specified and as directed.
S&F in repairs electronic fan regulator minimum 4 stepped Switch type suitable for ceiling fan of 1200/ 1400mm sweep as per site requirement complete all as specified and as directed.
S&F in repairs white cover plate with frame, 1 module complete all as specified and as directed.
S&F in repairs white cover plate with frame, 2 module complete all as specified and as directed.
S&F in repairs white cover plate with frame, 3 module complete all as specified and as directed.
S&F in repairs white cover plate with frame, 4 module complete all as specified and as directed.
S&F in repairs white cover plate with frame, 6 module complete all as specified and as directed.
S&F in repairs white cover plate with frame, 8 module (vertical) complete all as specified and as directed.
S&F in repairs white cover plate with frame, 12 module complete all as specified and as directed.
S&F in repairs Switch modular type, 1Module, 6 Amps one way complete all as specified and as directed.
S&F in repairs Switch modular type 1M 6 Amp 2-waycomplete all as specified and as directed.
S&F in repairs Bell push modular type 1M 5/6 Amp complete all as specified and as directed.
S&F in repairs Socket outlet modular type 2M, 5 pin, 6 Amp complete all as specified and as directed.
S&F in repairs Switch modular type, 16 Amp complete all as specified and as directed.
S&F in repairs Socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp complete all as specified and as directed.
S&F in repairs Electronic fan regulator, modular type 2M, 4 steps complete all as specified and as directed.
S&F in repairs Blank plate modular type 1M complete all as specified and as directed.
S&F in repairs PVC casing and capping 20mm in size suitable for wiring complete all as specified and as directed.
S&F in repairs wall mounted LED Integrated batten T5 20Watt -4ft white, 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type, complete all as specified and as directed.
S&F in repairs wall mounted LED Integrated batten T5 10Watt -2ft white, 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and as directed.
S&F in repairs old unserviceable wall light fixture any type with Wall mounting fitting City-4,Decorative wall light fixture made up of Polycarbonate, of B-22 base suitable for lamps upto 15 Watt complete all as specified and as directed.
S&F in repairs LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including required LED bulb and all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed.
S&F surface mounting Round/ Square shaped LED downlighter 6 Watt any type complete with including new fliexble wire as required on site and including taking down of old unsv existing ceiling light fitting complete all as specified and as directed.
S&F surface mounting Round/ Square shaped LED downlighter 12 Watt any type complete with including new fliexble wire as required on site and including taking down of old unsv existing ceiling light fitting complete all as specified and as directed.
S&F in repairs top cover 3 mm thick plastic/laminated sheet of various sizes with screw and cup washer including connection of switch, socket, regulators including connection through required size copper conductor PVC unsheathed complete all as specified and making good to disturbed surface as existing finishes complete all as specified and as directed.
S&F in rerpairs MCCB TP, 415V, any type, 200 Amps with breaking capacity 36 kA or of any description including providing new lugs & thimbles of required size complete all as specified and as directed.
S&F in repairs MCB TP 63 Amps 415 volts, 'C' Series 10 KA complete all as specified and as directed.
S&F in repairs MCB SPN 63 AMPs C curve complete all as specified and as directed.
S&F in repairs MCB SPN 40 AMPs C curve complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 AMPs C curve complete all as specified and as directed.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through capping and casing 20 mm dia complete all as specified and as directed. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and as directed.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 10 Sqmm in 2 runs and 6Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and as directed. Notes for Srl item No.95 & 96:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Notes for BoQ :- The rates quoted by the tenderer shall be inclusive of the provisions as mentioned under Srl Note Nos. (i) to (v) here-in-after. The tenderers are advised to keep in mind these provisions while quoting his rates. 1. The tenderer has to bring the consumable material which loose their identity like synthetic enamel paint, OBD, cement base paint, plastic emulsion paint, Lime, exterior emulsion paint, electrical fittings etc well in advance along with original purchase voucher as per sample approval. These material when brought by the tenderer shall be checked by BOO as detailed by GE and shall be kept in custody of concerned JE and rep of contractor with double lock arrangement in store room. The material shall be issued on daily basis as per site requirement. A Pucca bond register shall be maintained by the contractor showing total quantity in hand, quantity issued and quantity incorporated in the particular quarter which shall be initiated by both the party i.e JE and rep of contractor:- (i) 25% of total reqd material as per CA provision within 10 days from the date of commencement of work. (ii) 25% of the total reqd material as per CA provision within 03 month from date of commencement of the work or earlier as per site requirement. (iii) 25% of the total reqd material as per CA provision within 06 months from the date of commencement of the work or earlier as per site requirement. (iv) Balance 25% of the reqd material as per CA provision within 02 month before the date of completion or earlier as per site requirement. (v) Engineer-in-charge/ JE shall ensure the above provision is followed before commencement of the work at site.
2. The Qtr for welcome maintenance shall be handed over to contractor as per vacation/ allotment of Qtr and users requirement. After handing over the Qtr, the tenderer has to complete the work within 07 days for normal repair and 15 days for major repair as decided by Engineer-in-Charge which includes Sunday/ holiday. Necessary panel recovery shall be made Rs. 1000 per day if the qtr not handed over within the above stipulated time after handing over of Qtr. A Pucca bond register shall be maintained at site showing Qtr No, date of vacation, date of handing over the Qtr, proposed date of completion and actual date of completion which shall be got signed by the Engr-in-Charge. 3. Every stage like preparation of surfaces, first coat, second coat/ final coat of finishes shall be got passed by Engineer-in-Charge. 4. The replaced fitting of fixture which have been replaced under this contract shall be intimated to BSO for incorporating in inventory before handing over the Qtr. 5. The contractor shall cover all the furniture item while doing painting and other repair work, clean the entire house including paint marks on joinery items, glass panes, cupboard etc with entire satisfaction of Engineer-in-Charge before handing over the key back after welcome maintenance. 6. All the above documents shall be produced for verification at the time of payment of each RAR/Bill.
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
Chaudhary Constructions
SABHARWAL CONSTRUCTION CO.
M/S Parmod Johar
A N BUILDERS
P R Constructions
M/S GOPAL JEE SINGH
HANUMAN BUILDERS
VED PRAKASH ARORA
JAIPAL AND BROTHERS
RV. Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .