| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹21.2 L+₹1.2 L (5.82%)Rejected-Finance FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹23.7 L+₹3.7 L (18.2%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Mar 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
SPL REPAIR TO WATER PROOFING TREATMENT OF CERTAIN BLDG AND CREATION OF VENDOR INTERACTION ROOM AND A TECH STORE FOR 3D PRINTING FACILITY AT 1 CIMD AT AF STN OJHAR
2025_MES_696382_1
8263/E8
Open Tender
Civil Works
Item Rate
240 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
Yes
1 Jul 2025
4 Feb 2025
3 Mar 2025
5 Feb 2025
1 Mar 2025
15 Feb 2025
Amount
Taking down carefully existing bitumen tarfelt including plastering upto 15mm thick cleaning the surface and make free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and removing all foreign materials / Bitumenous primer completely , cleaning and washing the existing surface of roof/slab, terraces including flashings and junctions of parapets/Curb walls etc and as directed by Engineer-in-charge. Note : (i) Contractor will not throw the debris and taking down material from roof with suitable arrangement. (ii) If taking down of plaster is exceeding 15mm than PCC and plaster both shall be measured separately. iii) Any Lightning arrester (Earthing Strip) and pipe removing and refixing in same position. iv)) Removing of the rubbish to a distance outside MoD land at own arrangement of Contractor.
Demolition of cement Concrete of any description and in any position not otherwisespecifically provided for complete all as specified and as directed.
M&L providing cement slurry @ 3Kg per sqm on existing roof surface before laying PCC/ Plaster complete all as specified and as directed.
M&L for providing cement concrete 1:2:4 Type B0 (Using 12.5mm graded stone aggregate) as in bed plate/roof kerb/PCC padding and haunching etec all as specified and directed by Engr in Charge Note : PCC shall be laid in slope and thickness shall be averege (minimum average thickness 25 or as oer site requirement for maintaing the slope) as per site including filling in depression by providing concrete bench marks for maintaining th perfect slope to drain out the rain water as directed by Engr-in-Charge. No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof by Manually/ mechanically to acheive the proper strength and workmen ship.
M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces mixed with water proofing compound @ 0.12 ltr per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement. Note:- (Supply only water proofing compound shall be measured and paid separately).Complete all as specified and directed by Engineer-in-charge.
Supply only liquid water proofing compound
M&L for cleaning the newly plastered surfaces throughly with wire brushes and providing water proofing treatment all as given here in after (a) Bituminous primer @ 0.3lit per Sqm conforming to IS-3384-1986 (b) 3 mm thick APP polymer modified moply FP of M/S TEXSA Ltd or M/S STP Ltd or ASIAN PAINTS of Hydrostop Tiki Dan of M/s Tikki tar Ltd with minimum wt 3.0 Kg per square metre membrane (one layer) laid by torch application method. (c ) Applying two coat of bituminous based aluminium paint @ 0.20 Kg in two coats (total in two coats) per square metre over membrane. Complete all as specified and directed by Engineer-in-charge. (d) The overlaps of APP shall be SSR part 1 and APP shall be laid by expert/ skilled workers only, bitumen based aluminious paint applied by brushes only. (e) Any type of Lightning arrester, Earthing Strip and pipe removing and refixing in same position.
Taking Down Cement plaster on brick or stone wall any description including raking out joints , hacking for key , scrubbing down with water etc. complete all as specified and as directed
M & L For 15mm thick rendering on brick /concrete surfaces on broken edges or chajjas , facia slab , roof , projection and any other brick/concrete surface in patch work in CM 1:4 and finishing fair and even without using extra cement with using 2% intregal water proofing compound by weight of CementComplete all as specified and as directed ( Note :-i) Water Proofing compound will be measured and Paid sepreately under relevent item . ii) The rate quoated shall be deemed to include for work up to four story building and height up to 15.00 mtr including all safety measures , scafolding etc., rerquired for carrying out the work and nothing extra on this account shall be admisable.
M&L preparation of newly plastered surface of wall and applying 2 coats of cement based paint on on ecoat of alkali resistant primer complete all as specified and as directed.
Disconnecting existing PVC water tanks of any description, of capacity exc. 500 & n. exc. 1000 lit., setting aside for repair, cleaning etc. and hoisting if required reconnecting and re-fixing in position.complete all as specified & as directed by Engineer in charge.
S&F for Galvanised Iron tubes 20 mm dia medium grade with all fittings and fixtures such as bends , elbows ,tees ,short pieces , back nuts , connectors , diminishing pieces caps pegs and clamps union etc. laid in wall/floor/ceiling as in concealed work including cutting chase in wall and making good surface .
Supply and fixing in repair 500 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete and all as specified and as directed by Engineer-in-Charge
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair 20mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Removing Debris /Waste Material received from demolition exc.1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
M&L for Repair to RCC structure using micro concrete all as per manufactureres instructions, as descripbed below and as specified and directed. (a) chipping off existing loose and damaged/craked concrete/plaster surfaces at location decided by engr-in-charge to depth n.exc 100mm using peneumatic tools or with light chiseling & wire brush, descale the exposed surfaces of reinforcement with wire brushes removing all loose rust scales from rebar blowing all loose dust with blower and washing concrete surfaces. A coat of alkali rust converting primer to be applied on the reinforcement bar surfaces.(b) Welding additional reinforcement bars where dia of existing bar is found reduced than specified limit as directed. Note : Supply only reinforcement will be measured and paid separately. (c) Applying coat of anticorrosive protective coating on both old & new reinforcement bars surfaces as per manufactureres instructions.(d) Applying coat of epoxy resin concrete bonding agent to exposed concrete surfaces and rebars.(e) Providing polymer modified cement mortar in specified composition for making manufactureres instructions (Thickness varies from 25mm to 100mm) Note : - (i) The rate for necessaryscaffolding & formwork is included in the quoted rate. (ii) The work will be carried out upto G+4 floors
Supply only mild steel TMT Bars of 5mm dia and over upto and including 10mm in stirrups spacers and binding cut to length bent to shaps required,including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securibg with clips
M&L for 25mm cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in sub base complete all as specified and directed.
M&L for dark shade double charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set over 15mm screed bed in 1:6 cement mortar and jointed in neat cement slurry and pointed in white or coloured cement to match
All as per above item but in skirting on 10mm thick backing coat in 1:4 cement mortar
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth and getting out in hard/dense soil. complete all as specified and as directed by Engineer-In-Charge.
M&L for hard core (broken stone or boulders) of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M & L for cement concrete type C-2 (1:3:6) usng 40 mm graded broken stone aggregate 75 mm thick as sub base/plinth protection . complete all as specified and as directed by Engineer-In-Charge.
M&L for rubber moulded Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and as directed by Engineer-In-Charge.
Supply only well graded gravel for cushioning of required thickness and gradation under floors /hardstanding
M & L for Reinforced cement concrete B1 1:2:4 using 20 mm graded aggregates as in Columns, pillars, piers, posts and struts.complete all as specified and as directed by Engineer-In-Charge.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions on rough finished flat surface of concrete. complete all as specified and as directed by Engineer-In-Charge.
M & L for Reinforced cement concrete type B1 1:2:4 20 mm graded aggregates as in Beams, cantilevers, bressummers, lintels over 1.5m span. complete all as specified and as directed by Engineer-In-Charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by Engineer-In-Charge.
S&F mild steel TMT bars of 8 mm dia and over cut to length bent to shape required including cranking and binding with mild steel annealed wire not less than 0.9 mm dia or securing with clips. complete all as specified and as directed by Engineer-In-Charge.
Ditto,but 5 mm dia and over up to and including 10 mm dia in stirrups , spacers and binders. complete all as specified and as directed by Engineer-In-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-In-Charge.
M & L for rendering 20mm thick in cement plaster 1:4 on fair surfaces of brick work in two layers or concrete surfaces, is to be finished even and smooth without using extra cement in external using integral water proofing compound complete all as specified and as directed by Engineer-In-Charge.
ditto but 10 mm thick rendering in cement plaster 1:6 in internal.
M&L for applying 3mm wall care putty working in two layers with sanding to smooth and flawless surface complete all as specified and directed.
M&L for preparation of newly plastered surface and applying 2 coats of OBD over a coat of primer Complete all as specified and as directed by Engineer-In-Charge.
Complete removal of existing treatment and applying 2 coat of OBD on a coat of alkali resistant primer complete all as specified and directed.
Material and labour for new plastered surface applying two coat of exterior acrylic emulsion (Weather coat) over a coat of exterior acrylic primer of approved colour of ASIAN/Berger/CHOKSEY/STP of equivalent all as specified and as directed.Note: The rate quoted shall be deemed to include for work up to four storey building & height upto 15.00m including all safety measures, scaffoldings etc., required for carrying out the work and nothing extra on this account shall be admissible.
Material and labour for Preparation of old surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and greasy spots , removing nails etc., bringing surface to level by applying external wall care putty and applying two coats of exterior Acrylic emulsion (Apex)/Equivalent any colour on walls with and including provision of scaffolding required for the treatment to external surfaces of building with required safety measuers etc complete all as specified and as directed by Engineer in charge
M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engineer-In-Charge.
M & L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth as specified complete all as specified and as directed by Engineer-In-Charge.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc to store and rubbish not exc. 50m
M&L for Granite (of any colour or any grains as approved) work with 20 mm thick table rubbed and polished as in steps jambs , pillers , window cills, cooking platform and similar works including pointing in with cement using 1:2 using marble dust and admixture of pigments to match with the shade of granite over and including 15mm thick screed bed in CM 1:6 for laying granite all as specified and directed including taking down / dismantling of existing plaster/ stone of any type. Note : Granite shall be best quality and shall be provided one piece and width minimum 70mm in jambs except of cooking platform which shall be of full width as per site including full moulding of exposed edges with polishing. The back surface of granite shall be made rough by sprinkling small pebbles using adhesive for bonding with bedding layer.
M & L for powder coated aluminium sliding window with anodized aluminium frame of 3 Track of size 92mmx32mmx 1.5mm thick, with sliding shutters(02 glass and 01 Wirecloth) with necessary channels (top rail, bottom rail and style of size 40mmx 18mm x1.10 mm thick) including glazing with tinted sheet glass panel 4.00mm thick and Aluminum alloy wirecloth 0.40mm nominal dia and avg width of aperture 1.4mm, fitted with necessary joining cleats, glazing clips,locking device one for each shutter , rubber packing, aluminium beading, screws, rawl plugs including all necessary holes / drilling etc, complete all as specified as directed by Engineer -in -charge
Material and labour for providing Aluminium shutter with powder coated frame 88.9mmx47.63mmx1.60 mm thick and size of shutter with top rail , middle rail and bottom rail and style of size 85 mm x 44.5 mm x 1.56 mm thick with 200 mm size powder coated 2 nos with each leaf , Heavy duty powder coated aluminium tower bolt 150mm long 2 Nos per leaf, 3 nos Heavy duty aluminium powder coated hinges of size 125mm with each leaf including 12 mm thick both side prelaminated particle board / 5.5 mm thick glass pane in the both panel with necessary joining cleats, rubber packing, aluminium beading, hydraulicc door closer ,screws etc complete all as specified and as directed Note - All fitting shall be of same finished as of door shutter and shutter may be single/ double leaf, if the shutteris more than 1.10mtr it shall be of double leaf, the hollow section of vertical style where the hinges are to be provided the complete vertical style shall be provided with soft wood and minimum 65mm long screw provided for fixing of hinges compete all as specified as directed.
M&L for powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
M&L for Elegant Tile made of perforated cement fiber composite 595x595/295X1195/595X1195x5mm covered with absorptive microfiber coating on the front side and Acoustics fiber on the back side, water resistance, fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results. Note : If electrical cables are running at site aand required to be relocated electric fittings on walls are required to be shifted including refixing of fan/ light fittings and other light accessory including making good the wall surface.shall be deemed to be included to the rates.
S&F steel work in tubular trusses of design as approved, purlins, rafter, posts, gusset plates cleats, wind ties etc including special shape washers etc complete using ERW or induction butt welded tubes confirming to IS 116-1979 grade (medium grade)
S&F mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square but exc 5 cm but n.exc 10 cm long, dia of shank 5 to 10 mm.
M & L two coats of synthetic enamel paint on steel surfaces over one coat of red oxide or zinc chrome primer, of any description over 10cm width or girth including preparation of new or previously untreated surfaces of steel. compete all as specified as directed by Engineer -in -charge
S&F Collapsible steel gates, side operating, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete
S&F 12mm thick tinted toughened glass for door or vertical cladding or railing etc Make : Saint Gobain/ Modi/Swastik or any equvilant shall be provided with monogram/logo ( one logo of 1CIMD and other of Airforce) by etching on glass, filling the etching with multiple colour & design or any approved by Engr-in-Charge. Film coating , making holes to glass for fixing , fixed pivet in glass door, edge polishing to glass complete all as directed by Engr-in-Charge.
S&F 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P.laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
S&F for 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified by the manufacturer and as per directions of Engineer- in-charge.
S&F for 150mm Extruded aluminium alloy handles, fabricated type, anodised
S & F 300 mm long and Mild steel Chromium plated sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed compete all as specified as directed by Engineer -in -charge
S & F 150 mm aluminium anodised barrel tower bolts of extruded section, ISI marked compete all as specified as directed by Engineer -in -charge
Removing of building materials & debries of any type the rate included i.e loading ,unloading and stacking/spreading etc outside of MD land upto 1 km (6cum considered per load) with own arrangement by Contractor.
M & L for Point wiring with 1.5 Sqmm (nominal area) PVC( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm medium grade as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
All as per item no 64 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 64 but for One 5amps switch socket point independent.
M & L for Point wiring with 2.5 Sqmm (nominal area) PVC( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm medium grade as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
Supplying and fixing Modular switch , one way, 16 amps, one Module of Make:- Ancher Roma/Legrand/ Crabetree.
Supplying and fixing Modular socket 16 amps-6 pin multipin, 2 Module of Make:- Ancher Roma/Legrand/ Crabetree.
Modular switch one way 6 Amp,1 Module , Make Legrand / Anchor Roma/Crabetree .
Supplying and fixing Modular socket, 6 amps-2/3 pin combined, 2 Module, Make Legrand / Anchor Roma/Crabetree .
Supply & Fix Modular Fan regulator electronic step type 230 V 2 Module. Make :Legrand/Anchor/Roma.
Supply & Fix Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm two to three terminals. Make : Anchor/Leader.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA C series. MCB with separate short circuit indication type Make Legrand Cat. Nos 408595 Or equivalent Make :Siemens/L&T, Complete all as specified & as directed by Engineer-In-Charge
Supply and fix in repair MCB SPN 6 to 32 Amps 240 volts 10 KA. Make Legrand Cat. Nos 408617 Or equivalent Make :Siemens/L&T, Complete all as specified & as directed by Engineer-In-Charge
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar ,8 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
M&L wiring for circuit/ sub main wiring of 2x4.00 Sqmm+1x4.00 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in and including in PVC conduit 20mm dia medium grade complete all as directed by Engr -in- Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240 V of capacity 20 amps , complete all as specified and as directed by Engr-in-Charge.
S&F Exhaust fan 300 mm sweep ( Metallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers including making suitable size hole in the existing wall, plastering, white washing or colour washing to the disturbed surface of wall complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector including writing MES No. on Exhaust fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Havells Ventil Air DB NEO or equivalent in crompton / usha
S&F ceilling fan BLDC 1200 mm sweep operated on 230/240V AC Single phase electric supply ,5 star complete including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to fan connector including writing MES No. on Exhaust fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Bajaj ENERGOS28 or equivalent in Crompton /havells.
Supply, install, testing & commissioning hi wall split unit indoor/outdoor complete with cordless remote control unit and inverter type with minimum 5 star rating air conditioner electric driven, single phase of capacity 1.5 TR, as specified and as directed by engineer-in-charge.
Supply & Fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 280V with output voltage stabilized at 230V with accuracy of 2.5% and capacity of 4.0 KVA, complete all as specified and as directed by engineer in charge.
Santhi Enterprises (BID ID -3245932)
M/S PRAMOD SURESHCHANDRA AHER (BID ID -3252387)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .