Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.9 LAccepted-AOC R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-1 | Accepted-AOC Accepted Being L-1 | |
| 2 | L-2₹6.3 L+₹40,129 (6.83%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L-2 | Rejected-Finance Other Than
L-1 | |
| 3 | L-3₹6.9 L+₹1.1 L (18.0%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L-3 | Rejected-Finance Other Than
L-1 |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
PROVISION OF CERTAIN SANCTIONED AND REVENUE WORKS AT HQ CIF (K) UNDER AGE (I) CIF (K).
2022_MES_539259_1
CA NO. AGE (I) CIF (K)-57/2022-23
Open Tender
Civil Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹17,000
Yes
20 Aug 2022
19 Jul 2022
18 Aug 2022
19 Jul 2022
16 Aug 2022
2 Aug 2022
Amount
B/R Works: Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out and removing surplus soil to a distance not exceeding. 50 metre and making good surface in hard/dense soil , complete all as specified and as directed by the Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified as directed by the Engineer-in-Charge.
Mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and asdirected by Engineer-in-Charge.
Mild steel screw bolts (machine made) dia of neck 11 to 16mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 22.5cm but not exceeding 30cm long, complete all as specified as directed by the Engineer-in-Charge.
Pre-painted galvalume aluminum zinc coating GI based corrugated profile steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to ridges, valley gutters etc. fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
Surface excavationn.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying of cable and foundation of poles, stays etc. n exc 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, complete all as specified and as directed by Engineer-in-Charge.
Hardcore of broken stone or boulders, gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by the Engineer-in-Charge.
Plain cement concrete, 1:4:8, type D-2 using 40mm graded crushed stone aggregate, 100mm thick, as in sub-base of floor/path, sub base etc. finishing surfaces even and rough to receive topping layer, complete all as specified and as directed by the Engineer-in-Charge.
Pre-painted Chequered cement concrete coloured tiles of size 300 cm x 300 cm x 25mm (2.5 cm) thick (Glossy finished) set, jointed and pointed in neat cement slurry in floors,with grey cement and pigment, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n.exc 1.5 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) , complete all as specified and directed by the Engineer-in-Charge.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n.exc 4 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost), complete all as specified and as directed by the Engineer-in-Charge.
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and asdirected by the Engineer-in-Charge.
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including powder coating of any colour (Thickness or powder coating not less than 50 micron), complete all as specified and as directed by the Engineer-in-Charge.
5mm Printed PVC sheet used instead of plain colour PVC shect in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining , Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site, complete all as specified and as directed by the Engineer-in-Charge.
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) including powder coating of any colour (Thickness or powder coating not less than 50 micron). complete all as specified as directed by the Engineer-in-Charge.
Aluminium (extruded section body) door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed , complete all as specified as directed by the Engineer-in-Charge.
Mild steel framed work such as grills, gratings with ends of bars shouldered or reveted or forged into spikes, framed guard bars, iron door etc and similar work, conforming to Fe-290, Gde E-165, complete all as specified as directed by the Engineer-in-Charge.
Mild steel round bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by the Engineer-in-Charge.
Sheet glass 4mm thick ordinary quality and glazing with in aluminium frames including necessary joining cleats,glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitting as required in squares not exc. 0.5 Sqm in each pane, complete all as specified as directed by the Engineer-in-Charge.
Mild steel galvanised wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, wire staples or beading etc., complete all as specified as directed by the Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles including removing of rubish, complete all as specified and as directed by the Engineer-in-Charge.
Brick work with subclass 'B' bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortor 1:6, complete all as specified and as directed by the Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces, complete all as specified as directed by the Engineer-in-Charge.
Reinforced cement concrete (Nominal mix) 1:2:4 type B-1 using 20mm graded crushed stone aggragte as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified as directed by the Engineer-in-Charge.
Plain cement concrete 1:2:4, type B-1 ( using 20 mm graded crushed stone aggregate) as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and asdirected by the Engineer-in-Charge. Note:- Reinforcement shall me measured and paid for separately under respective item of this BOQ.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge.
Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge.
Supply only liquid water prppfing compound of approved make., complete all as specified and as directed by Engineer-in-Charge.
Preparation of new plastered surfaces of wall and applying two coats of colour wash over a coat of white wash, complete all as specified and as directed by the Engineer-in-Charge.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and as directed by the Engineer-in-Charge.
Filling under floors with available earth including spreading and levelling in layers not exceeding 25cm thick, well ramming and watering as required, complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete, 1:2:4, type B-1 using 20mm graded crushed stone aggregate, 50mm thick, as in flooring, surface finished even and smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed by the Engineer-in-Charge.
Preparation of newly untreated steel or iron surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate,complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate, 75 mm thick as in plinth protection laid in alternate bays (n exc 2 Sqm each) and finished even and fair without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and as directed by Engineer-in-Charge.
E/M Works: Point wiring with 1.5 sqmm copper conductor (Multistranded) PVC insulated and unsheatheted FRLS electric cable 1100 volts grade and including PVC casing caping/conduit pipe of suitable size with all fittings accessories and including PVC insulated electric cable 1100 volts, 1.5 sqmm (multi stranded) copper conductor single core (Green colour) cable as continious earth wire connected to common earth dolly including sunk sheet terminal box made out of 1.6 mm thick MS sheet concealed on wall or on surface as per site requirement and making good distrubed surface of wall ,covered with 3 mm thick plastic laminated for mounting of switches, socket, fan regulators etc., complete all as specified and directed by the Engineer-in-Charge for the following:-
One light /fan/bell point controlled by one No, one way 5 Amps switch. complete all as specified and as directed by the Engineer-in-Charge.
One 3/5 pin socket outlet, 5 Amp, independent, controlled by one No. one way switch on independent board, complete all as specified and as directed by the Engineer-in-Charge.
One 3/5 pin socket outlet, 5 Amp controlled by one No, one way switch on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per serial item No 40 here-in-before ,but for one socket out let 15 Amp on the independent board with 2.5 sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts (ISI MARKED) including PVC insulated and unsheathed electric cable 1100 volts, 2.5 sqmm copper stranded conductor as continious earth wire connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge.
Sheet metal enclosure factory made (single door) shutter type for MCB DB SPN horizental type, 440 Volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and as directed by the Engineer-in-Charge.
MCB SPN, 40 to 63 Amps, 230 volts, 10 KA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
MCB SP, 5 -32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
Piano type switch one way, SP, flush type, 5 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Piano type socket outlet, flush type, 2 in 1, 3 pin, 5 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Piano type switch one way, SP, flush type, 15 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Piano type socket outlet, flush type, 2 in 1, 3 pin, 5 and 15 amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Ceiling rose surface type, 65 mm x 50 mm three terminals/PVC/polycarbonate, isolated body fixed on PVC block,complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by the Engineer-in-Charge. Make: Havells Cat part No LHEXBLP7PN1W018 or equivalent in Bajaj/Crompton Greaves /Phillips
Angular Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings , complete all as specified and as directed by the Engineer-in-Charge. Make:- Anchor/Havells/Plaza/SSK.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire,4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009), complete all as specified and directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc., including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note:- Earthing work, Sand cushioning and Brick shall be measured and paid separately
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge.
Galvanized iron tubing 50mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables including taking out down/out old existing pipe, complete all as specified and directed by Engineer- in-Charge.
Note :- An amount of Rs. 2,350.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S SHEIKH FEROOZ AHMAD
JK BUILDERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .