Refer Docs
EMD Value
₹95,000
Closing Date
27 Jan 2022, 11:00 amClosed
Jyotishman Kakoty 9435593212
Numaligarh Refinery Limited
Supply, installation, testing and commissioning of HVAC system at Adm. Building annex. NRL Site
2021_NRL_656228_2
OC15000319/JYO
Open Tender
Miscellaneous Works
Works
75 days
Numaligarh Refinery Limited
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹95,000
Yes
21 Feb 2022
13 Jan 2022
28 Jan 2022
13 Jan 2022
27 Jan 2022
13 Jan 2022
Amount
Miscellaneous electrical jobs for temporary construction power facilities etc. for NREP
10 HP Heat Pump Type (Cooling & Heating ) Nominal Capacity in Single modules including interconnection kit & MS Stands
permitted. 12 HP Heat Pump Type (Cooling & Heating ) Nominal Capacity in Single modules including interconnection kit & MS Stands
14 HP Heat Pump Type (Cooling & Heating ) Nominal Capacity in Single modules including interconnection kit & MS Stands
16 HP Heat Pump Type (Cooling & Heating ) Nominal Capacity in Single / Two or more modules including interconnection kit & MS Stands
18 HP Heat Pump Type (Cooling & Heating ) Nominal Capacity in Single / Two or more modules including interconnection kit & MS Stands
20 HP Heat Pump Type (Cooling & Heating ) Nominal Capacity in Single / Two or more modules including interconnection kit & MS Stands
Supply Instalaltion, testing & commissioning of Indoor Units
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit
Supply Instalaltion, testing & commissioning of Indoor Units
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit
Supply Instalaltion, testing & commissioning of Y-joints.
Supply Instalaltion, testing & commissioning of AHU EEV KIT
Supply Instalaltion, testing & commissioning of self diagnostic type remote controllers . Cordless/corded type
Supply Instalaltion, testing & commissioning of Main Intelligent Touch Screen central controller system suitable for 128 indoor units
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -41.3 mm O.D. Pipe Size with insulation of 25 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -34.9 mm O.D. Pipe Size with insulation of 25 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -28.6 mm O.D. Pipe Size with insulation of 25 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -22.2 mm O.D. Pipe Size with insulation of 25 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -19.1 mm O.D. Pipe Size with insulation of 25 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -15.9 mm O.D. Pipe Size with insulation of 19 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -12.7 mm O.D. Pipe Size with insulation of 19 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -9.5 mm O.D. Pipe Size with insulation of 19 mm thick
Refrigerant Piping Supply& Fixing of Interconnecting copper refrigerant pipe work -6.4 mm O.D. Pipe Size with insulation of 19 mm thick
S&F of UPVC drain water piping
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Flexible Duct Dia 100 mm
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supply,installation and testing of multiblade type GI Duct Damper for duct/collars to be provided with suitable links and quadrants for control of volume of air
Supplying & fixing of powder coated Linear extruded aluminium Supply / Return Air Grills with aluminium volume control dampers as per specifications. 100 mm
"Supplying & fixing of powder coated Linear extruded aluminium Supply / Return Air Grills with aluminium volume control dampers as per specifications. 150 mm
Supplying & fixing of Fresh air intake louvers with bird screen dampers (Aluminium extruded only
"Supplying and fixing of acoustic lining of duct with Open Cell Nitrile Rubber density 140-180 Kg/m³. Applied by Adhesive, conforming to standard specification. 10 mm thick open cell nitrile rubber.
"Supply & Installation of Thermal Insulation on Ducts -19mm
"Supplying, installing, testing and commissioning of Pressure Independent Variable Air voulme Terminal units -700cfm
Supplying, installing, testing and commissioning of Pressure Independent Variable Air voulme Terminal units -1200cfm
Supplying, installing, testing and commissioning of Pressure Independent Variable Air voulme Terminal units -1400cfm
Supplying, Fixing,testing and commissioning of fire dampers
Supplying, Fixing,testing and commissioning of fire dampers
MOTOR CONTROL CENTRE For Total 328 HP Unit
POWER & CONTROL CABLING 4C x 6 Sq mm
POWER & CONTROL CABLING 4C x 10 Sq mm
POWER & CONTROL CABLING 2C x 1.5 Sq mm
POWER & CONTROL CABLING 3C x 2.5 Sq mm
Supplying and installing following size of perforated pre-painted M.S cable trays -150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays -300 mm width x 50 mm depth x 1.6 mm thickness
Providing & fixing of weather-Proof Isolator 40A with ELCB for each Outdoor unit
Providing & fixing of weather-Proof Isolator 63A with ELCB for each Outdoor unit.
"Supply installation, testing and commissioning of Tube Axial fan confirming to IS-3588 (revised) Air Qty. = 3000 CFM
"Supply installation, testing and commissioning of Tube Axial fan confirming to IS-3588 (revised) Air Qty. = 5000 CFM
"Supply installation, testing and commissioning of Tube Axial fan confirming to IS-3588 (revised) Air Qty. = 9000 CFM
"Supply installation, testing and commissioning of Tube Axial fan confirming to IS-3588 (revised) Air Qty. = 11000 CFM
"Supply installation, testing and commissioning of Tube Axial fan confirming to IS-3588 (revised) Air Qty. = 8000 CFM
"Supply installation, testing and commissioning of Tube Axial fan confirming to IS-3588 (revised) Air Qty. = 26000 CFM
Supply installation, testing and commissioning of Inline Fan directly coupled TEFC Sq.cage induction motor Air Qty. = 800 CFM
32 A 6 pole isolator switch for S/Ex Fan Motor with sheet metal enclosure, rain protection etc. as required to suit the site condition.
Supply installation, testing and commissioning of single phase propellar fan suitable for 220V±10%, 50 Hz. 1 phase electric supply complete electrica with required hardware etc. 200 mm di
Supply installation, testing and commissioning of single phase propellar fan suitable for 220V±10%, 50 Hz. 1 phase electric supply complete electrica with required hardware etc. 450 mm dia
For Ventilation Fan ( 1 x UP to 15 HP Fan Motor Each) 01 Set - 40 A TP MCB with BIS DOL starter , overload relay start/stop push buttons, ammeter (0-40A), on / off / trip indication lights with protection fuse, single phase preventer.
Space Art Pvt Ltd
Purvi Engineers India Pvt Ltd
Opsis Projects India Pvt Ltd
Aqua Cool Co. Pvt.Ltd.
TRAC FUJICO AIR SYSTEMS LLP
JOS ENGINEERING CO.
Anemo Projects Pvt Ltd
SUPER TECH AIRCON PRIVATE LIMITED
ACE ALLIANCE (P) LTD
Elemech Solution Private Limited
JOY S ENTERPRISE
RS COOLING APPLIANCES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .