| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.8 LQualified Make: Cooper Corp
Model: 10 KVA COOPER ENGINE 2A1D1C10.3CW - 1.2 mm Thk 3P AMF 0 THAPAK BAAG KUMAR KA BAAG OUT SIDE DATIA GATE JHANSI JHANSI UTTAR PRADESH 284001 | JHANSI | UTTAR PRADESH | 284001 | Make: Cooper Corp
Model: 10 KVA COOPER ENGINE 2A1D1C10.3CW - 1.2 mm Thk 3P AMF | ₹3.8 L | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
26 May 2018, 1:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 10 10 No of Phase - Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No
if applicable - - Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic Class of governer A1 A0
A1
A2 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for 10 - 1/4 one hour for every 11 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 10 - Power Factor of AC generator 0.81 - Efficiency at rated Power factor at 75% of full Load 88.1 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 55 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 Thickness of Foam 33.4 - Density of Foam for sound insulation 32.4 - Noise level at 1 meter (dB) 73 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 3 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sarvesh Ramnath Naik 403401
Indian Institute of Technology Goa
At Goa Engineering College Campus
Admin Block
Farmagudi
Ponda
Goa 1 15 EMD Required No ePBG Required No
93451
GEM/2018/B/13334
diesel generators- DG Sets
15 days
Goa; South Goa
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 10 10 No of Phase - Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No | - | - | - |
| if applicable - - Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic Class of governer A1 A0 | - | - | - |
| A1 | - | - | - |
| A2 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for 10 - 1/4 one hour for every 11 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 10 - Power Factor of AC generator 0.81 - Efficiency at rated Power factor at 75% of full Load 88.1 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 55 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 33.4 - Density of Foam for sound insulation 32.4 - Noise level at 1 meter (dB) 73 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 3 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sarvesh Ramnath Naik 403401 | - | - | - |
| Indian Institute of Technology Goa | - | - | - |
| At Goa Engineering College Campus | - | - | - |
| Admin Block | - | - | - |
| Farmagudi | - | - | - |
| Ponda | - | - | - |
| Goa 1 15 EMD Required No ePBG Required No | - | - | - |
Exempted
26 May 2018
16 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_93451.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .