Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.4 L+₹2.2 L (10.2%)Rejected-Finance 93 61 AGARWAL FARM MANSAROVER JAIPUR 302020 | JAIPUR | JAIPUR | RAJASTHAN | 302020 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.5 L+₹3.3 L (15.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹25.9 L+₹4.7 L (22.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹25.9 L+₹4.7 L (22.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/s Prakash Enterprises L1 | M/S Anil Enterprises L2 | SHREE BHAGWATI ENTERPRISES L5 | LAKSHMI ASSOCIATES L3 | S.R.Enterprises L4 | Dev Enterprises L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in repair Gun metal gate non return valves for iron pipe of 15 mm bore dia of pipe complete all as specified and directed. | 40 | EACH | 500 ₹20,000 | 80 ₹3,200 Lowest | 350 ₹14,000 | 450 ₹18,000 | 250 ₹10,000 | 380 ₹15,200 |
| 2.00 | S&F in repair Gun metal gate non return valves for iron pipe of 20 mm bore dia of pipe complete all as specified and directed. | 10 | EACH | 600 ₹6,000 | 120 ₹1,200 Lowest | 400 ₹4,000 | 550 ₹5,500 | 300 ₹3,000 | 400 ₹4,000 |
| 3.00 | M&L in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately. | 360 | RM | 100 ₹36,000 | 75 ₹27,000 Lowest | 95 ₹34,200 | 90 ₹32,400 | 90 ₹32,400 | 145 ₹52,200 |
| 4.00 | M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified and directed.
Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately. | 250 | RM | 100 ₹25,000 | 95 ₹23,750 Lowest | 104 ₹26,000 | 110 ₹27,500 | 100 ₹25,000 | 180 ₹45,000 |
| 5.00 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 Sqmm (Green), in PVC casing & caping, not less than 25mm x 15mm, ISI marked ivory colour with all fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 Pin 15 Amps socket outlet on independent board, complete all as specified and directed.
Note :-
(i) The Switch / Socket accessories shall be measure and paid separately.
(ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate. | 60 | POINT | 300 ₹18,000 Lowest | 700 ₹42,000 | 700 ₹42,000 | 650 ₹39,000 | 700 ₹42,000 | 800 ₹48,000 |
| 6.00 | S&F in repair switch piano, flush type, 6 amps single pole, one way, complete all as specified and directed. | 190 | EACH | 20 ₹3,800 | 20 ₹3,800 | 18 ₹3,420 | 16 ₹3,040 Lowest | 22 ₹4,180 | 25 ₹4,750 |
| 7.00 | S&F in repair Fan step regulator, 120W - 2 module complete all as specified and directed. | 150 | EACH | 200 ₹30,000 | 350 ₹52,500 | 185 ₹27,750 | 290 ₹43,500 | 170 ₹25,500 Lowest | 180 ₹27,000 |
| 8.00 | S&F in replacement sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB of capacity 20 Amps complete all as directed. | 30 | EACH | 800 ₹24,000 | 650 ₹19,500 | 650 ₹19,500 | 605 ₹18,150 | 800 ₹24,000 | 600 ₹18,000 Lowest |
| 9.00 | S&F in repair sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 8 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed. | 8 | EACH | 1,500 ₹12,000 | 950 ₹7,600 | 1,400 ₹11,200 | 900 ₹7,200 Lowest | 1,600 ₹12,800 | 1,200 ₹9,600 |
| 10.00 | S&F in repair sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 12 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed. | 5 | EACH | 1,800 ₹9,000 | 1,300 ₹6,500 | 1,800 ₹9,000 | 1,250 ₹6,250 Lowest | 2,000 ₹10,000 | 1,450 ₹7,250 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINTENANCE OF SUMMER AND WINTER APPLIANCES AT SWC SIGNAL REGT, SUB AREA, STN HQ, PRATAP LINE (I TO V), NIRMAN VIHAR (I TO III), CWE OFFICE, GE(S), GE CTL, E/M INSTALLATIONS, GE (PROJECT) UNDER GE(S) JAIPUR AT MIL STN JAIPUR
2025_MES_726483_1
GE(S)/J-30P/2025-26 8412/E8
Open Tender
Civil Works
Item Rate
270 days
GE (S) Jaipur
Class D and category b(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹70,000
Yes
18 Oct 2025
18 Aug 2025
24 Sept 2025
18 Aug 2025
17 Sept 2025
3 Sept 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .