| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | ₹2.7 L Quoted ₹2.2 L | L1 | Accepted-AOC Accepted as L1 as per NIT |
| 2 | L2₹2.3 LRejected-Finance KATHARA DIST BOKARO 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | ₹2.3 L | L2 | Rejected-Finance Rejected as not L1 per NIT |
| 3 | Rejected-Technical AT MQ 49 BODIYA BASTI KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | - | Rejected-Technical Rejected as per NIT |
| Sl No | Description | Qty | Unit | M/S P. L. CONSTRUCTION L1 | M/S JAY GURU CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.01 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. | 2 | No | 7,383 ₹14,766 | 7,390 ₹14,780 |
| 1.02 | Supplying & Erection of galvanized stay set 11KV. O/ H lines complete with 19/20 mm dia x1.8 meters long stay rod, anchor plate of size 45cmx45 cm x7.5 mm thick, thimble, stay clamp, turn buckle (20mm x 600mm), 7/4.00 mm dia G.I stay wire and 11KV. strain insulator etc, in cement concrete 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. | 6 | No | 5,066 ₹30,396 | 5,100 ₹30,600 |
| 1.03 | Erection of all aluminum conductor of 7/3.40 mm to 7/4.00 dia meter including binding etc. as required. (07 span x 3 wire x 50 mtr..x 0. 342Kg./-mtr)= 359.10 Kg. | 359.1 | Kg | 162 ₹58,174.20 | 165 ₹59,251.50 |
| 1.04 | Supplying & erection of 11KV. grade disc insulator with hardware for 11KV. O/H lines with galvanized insulator fittings, ball & socket type and complete with galvanized strain clamp, bolts, nuts, washer etc. as required | 24 | No | 884 ₹21,216 | 885 ₹21,240 |
| 1.05 | Supplying & erection of 11KV. pin insulator with large steel hard G.I pin, nut, washer etc. as required | 27 | Set | 273 ₹7,371 | 275 ₹7,425 |
| 1.06 | Supplying of channel iron 75mm x 40 mm. x 7.14Kg. per meter pole top bracket/cross arm for single 11KV. O/H line conductor complete with 50mm x 6mm flat iron clamps, bolts & nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required | 20 | Each | 506 ₹10,120 | 510 ₹10,200 |
| 1.07 | Supplying of channel iron 75mmx40mm x 7.14 Kg. per mtr.) cross arm for two 11KV. overhead line conductors complete with 50mm x 50mm x 6 mm(angle iron bracket welded to the channel iron and complete with 50 mm x 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulators pins, bolts, nuts and washers etc.(as per drawing) and painting with primer and finish | 4 | Each | 2,082 ₹8,328 | 2,090 ₹8,360 |
| 1.08 | Dismantling of O/H lines comprising of copper/ Aluminum overhead conductor, G.I. wire, cross arms, insulators etc. as required. (a) Conductor 1.050 Km.x.342Kg./-Km.= 359.10 Kg.
(b) Channel bracket 6 mtr..x7.14/-Kg.M.)= 42.84 Kg.
(c) Disc insulator (24 Nos.x 6Kg)= 144.00Kg.
(d) Pin insulator 11KV. (27Nos.x 2Kg.)= 54.00Kg.
599.94Kg. | 599.94 | Kg | 70 ₹41,995.80 | 75 ₹44,995.50 |
| 1.09 | Dismantling of pole/ street light/strut embedded in cement concrete foundation etc. as required. | 2 | each | 208 ₹416 | 210 ₹420 |
| 1.10 | Erection of cradle guard as required | 4 | No | 118 ₹472 | 120 ₹480 |
Tender Value
₹2.5 L
EMD Value
₹3,200
Closing Date
2 Mar 2026, 4:00 pmClosed
Colliery Manager (M),Manager(F),Project Engineer(E
Colliery Manager (M),Manager(F),Project Engineer(E
Replacement of damaged pole, conductor, insulators and earth wire of 6.6 KV O/H line from Regional sub-station to electrical sub-station No.-02 of Kathara Colliery.
2026_CCL_353688_1
KTC/PE/EnM/25-26/93 Date-19.02.2026
Open Tender
Electrical and Maintenance Works
15 days
Project Engineer (EnM), Kathara Colliery
Replacement of damaged pole, conductor, insulators and earth wire of 6.6 KV O/H line from Regional sub-station to electrical sub-station No.-02 of Kathara Colliery.
5 documents required · 5 mandatory
₹3,200
19 Mar 2026
19 Feb 2026
3 Mar 2026
20 Feb 2026
2 Mar 2026
20 Feb 2026
20 Feb 2026 - 26 Feb 2026
Erection of metallic pole of following length in cement concrete 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
Supplying & Erection of galvanized stay set 11KV. O/ H lines complete with 19/20 mm dia x1.8 meters long stay rod, anchor plate of size 45cmx45 cm x7.5 mm thick, thimble, stay clamp, turn buckle (20mm x 600mm), 7/4.00 mm dia G.I stay wire and 11KV. strain insulator etc, in cement concrete 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
Erection of all aluminum conductor of 7/3.40 mm to 7/4.00 dia meter including binding etc. as required. (07 span x 3 wire x 50 mtr..x 0. 342Kg./-mtr)= 359.10 Kg.
Supplying & erection of 11KV. grade disc insulator with hardware for 11KV. O/H lines with galvanized insulator fittings, ball & socket type and complete with galvanized strain clamp, bolts, nuts, washer etc. as required
Supplying & erection of 11KV. pin insulator with large steel hard G.I pin, nut, washer etc. as required
Supplying of channel iron 75mm x 40 mm. x 7.14Kg. per meter pole top bracket/cross arm for single 11KV. O/H line conductor complete with 50mm x 6mm flat iron clamps, bolts & nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Supplying of channel iron 75mmx40mm x 7.14 Kg. per mtr.) cross arm for two 11KV. overhead line conductors complete with 50mm x 50mm x 6 mm(angle iron bracket welded to the channel iron and complete with 50 mm x 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulators pins, bolts, nuts and washers etc.(as per drawing) and painting with primer and finish
Dismantling of O/H lines comprising of copper/ Aluminum overhead conductor, G.I. wire, cross arms, insulators etc. as required. (a) Conductor 1.050 Km.x.342Kg./-Km.= 359.10 Kg. (b) Channel bracket 6 mtr..x7.14/-Kg.M.)= 42.84 Kg. (c) Disc insulator (24 Nos.x 6Kg)= 144.00Kg. (d) Pin insulator 11KV. (27Nos.x 2Kg.)= 54.00Kg. 599.94Kg.
Dismantling of pole/ street light/strut embedded in cement concrete foundation etc. as required.
Erection of cradle guard as required
Supplying of clamp Nut & bolt
Supply of 8 SWG GI wire (for cradling)
Supply and erection of 8 SWG GI wire (for earth continuity)
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.99 MB
BOQ_366497.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid