Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹8.5 L+₹1,650 (0.19%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹8.6 L+₹11,761 (1.39%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹9.4 L+₹89,797 (10.6%)Rejected-Finance SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | L4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
16 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Fatehgarh
AGE (I) Fatehgarh
REPAIR/MAINT OF LT EXTERNAL WORKS OF MD/ACCN OF SLI AT FATEHGARH CANTT
2024_MES_688831_1
AGE(I)/FAT/ET-53 OF 2024-2025
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Fatehgarh
₹20,000
Yes
22 Feb 2025
18 Dec 2024
22 Jan 2025
18 Dec 2024
16 Jan 2025
3 Jan 2025
19 Dec 2024 - 2 Jan 2025
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth and getting out soft/loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well remming in layer not exc 25 cm.
Removing excavated material n.exc 50 m and depositing where directed a level n. exc 1.5 m above the starting point all as direced.
M&L for sand cushioning to U/G cable in layers of 23 cm thick (8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned down volume shall be measured.
Supply and lay burnt best quality locally available old size sub class `B' brick laid in trenches prependicular to U/G cable for cable protection complete all as specifed and as directed
Laying only old serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable), laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE cable of size 120 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross complete all as specified and as directed.
All as per item above but for size 95 Sq mm X 3.5 core…ditto as above…..
All as per item above but for size 70 Sq mm X 3.5 core…ditto as above…..
All as per item above but for size 35 Sq mm X 3.5 core…ditto as above…..
All as per item above but for size 16 Sq mm X 4 core…ditto as above…..
All as per item above but for size 16 Sq mm X 2 core…ditto as above…..
All as per item above but for size 10 Sq mm X 2 core…ditto as above…..
Relaying of existing serviceable cable in trenches or passing through pipe obtaind from 10 Sqmm to 120 Sqmm 2/3.5/4 Core after taking out complete all as specified and directed.
Taking out old unserviceable LT U/G cable from trenches or passing through pipe of size 10 Sqmm to 120 Sqmm 2/3.5/4 core complete all as specified and as directed.
Supply and laying in replacement GI tubing light grade galvanised 80 dia bore in trenches, wall/poles and across the road with all fittings such as bends, elbow,tees, short pieces, connectors, back nuts, diminishing pieces, caps, lugs etc including, cutting, screwing/threading and waste for making forged bends on pipe socket and union etc complete all as specified and directed. Note :- (i) The cost of the clamp, nuts, bolts and washers will be paid separately under the relevant item.
All as per itme above but for size 40 mm dia…ditto as above…
All as per itme above but for size 25 mm dia…..ditto as above…..
S&F in structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, complete all as specified and directed.
Dismantling of steel work (brackets, clamps, channels including disc pin insulator, nut & bolts) from exsiting LT poles all as specified and directed by Engr-in-Charge.
Restretching of existing loose OH,LT ACSR conductor wire including GI wire along the span of poles for sagging within the permissible limit,(five/four/two wireline), including binding/rebinding/joining with Aluminium winding wire in case of breakge of condouctor, size of winding wire shall not be less than 2 sqmm complete all as specified and directed by Engr-in-charge. Note:- (i) Contractor shall take electric shutdown before stat the wrok form main station and start line after triming of tree and informed to the JE Engineer-in-charge. (ii) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during the stretching.
S & F in repair shackle type,vitreous Insulator incl one galvanised mild steel spindle, two galvanised iron washerrs,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt,complete all as specified and directed.
Fabrication, supply, installation testing and commssioning in replacement outdoor type LT Feeder Pillar Box(FPB) with provision of 02 Nos MCCB(01 Incommer and 01 No Outgoing)made out from 3.15 mm thick sheet CRCA MS sheet (CPRI approve) over all size 0.75x0.60x0.30m front operated, two part hinged doors with locking arrangement with aluminium bus bar suitable for 3 phase 415 Volts, 50 Hz, AC supply 200 Amps rated mounted on SMC/DMC insulators with heat shrinkable PVC sleeves having RYB-B colour code, drilled and tapped with nuts, bolts and washers with two openable front and rear door for connection of incoming and outgoing complete powder coated painting, testing and insttalation on angle iron stand of suitable size with 40mm x 40 mm x 6 mm thick angle iron frame work in PCC of 1:3:6 complete all as specified and directed. Note :-(i) MCCB will be paid and measured separately under relevant item. (ii) Provision of MCCB be made to be fixed in independent cabin in horizontal position with Main bus bar chamber.
Supply, fixing, fabrication, installation, Testing and commissioning of out door type lT feeder Pillar box of over all dimesnion 0.70x0.50x1.0 m with front and rear opening doors with electrolysis Aluminium bus bars of 1 ½ times mounted on SMC/DMC insulators from the incoming capacity of MCCB made of 3.15 mm thick out side door and 2.00 mm thick inside (MCCB cabin) doors with provision of lock & key of CRCA MS Sheet duly preleminated, pre treated and powder coated, factory fabricated panel with provision of extension, dust/vermin proof and weather proof, cubical cable alloy for panel mounted on stand of angle iron of size 40 mm x 40 mm x 6 mm thick and goruted to ground with PCC 1:3:6. The panel comprises of the following :- (a) S&F MCCB 4 Pole 415 Volts Ac 50, 160 Amps rupturing capacity 16 KA Ics/Icu rating-100% - 01 No (incoming). (b) S&F MCCB 4 Pole 415 Volts Ac 50, 100 Amps rupturing capacity 16 KA Ics/Icu rating-100% - 02 Nos (Outgoing). (c) S&F MCCB 4 Pole 415 Volts Ac 50, 63 Amps rupturing capacity 16 KA Ics/Icu rating-100% - 02 Nos (outgoing). (d) S&F Digital Digital volt Ammeter 96 Sqmm (Square type) complete with slector switch with suitable size of CTs complete -01 Set. (e) S&F Voltmeter complete of size 96 Sqmm (Square type) complete with slector switch -01 No (f) S&F aluminium bus bar (RYB-B) of suitable size shall be provided form the main bus bar to the out going MCCBs. (g) S&F RYB LED indicator lamp - 01 Set.
Taking out/Dismantling exsiting unserviceable feeder pillar box including disconnection from different site.
M&L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth Strip of size 25mmx4mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and earth strip protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
Taking out/dismantling of old material obtained form old unsv earthing like earth plate electrode and earth continuity conductor, watering pipe, funnel and earth test point etc complete all as specified and directed
S&F MCCB 400 Amps, 4 Pole, 415 Volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with exisiting size and make as suitable to fit in the exisiting lT FPB and Ics/Icu rating = 100% complete all as specified and directed.
S&F MCCB 315 Amps, 4 Pole, 415 Volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with exisiting size and make as suitable to fit in the exisiting lT FPB and Ics/Icu rating = 100% complete all as specified and directed.
S&F MCCB 250 Amps, 4 Pole, 415 Volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with exisiting size and make as suitable to fit in the exisiting lT FPB and Ics/Icu rating = 100% complete all as specified and directed.
S&FMCCB 200 Amps, 4 Pole, 415 Volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with exisiting size and make as suitable to fit in the exisiting lT FPB and Ics/Icu rating = 100% complete all as specified and directed.
S&F MCCB 200 Amps, 3 Pole, 415 Volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with exisiting size and make as suitable to fit in the exisiting lT FPB and Ics/Icu rating = 100% complete all as specified and directed.
M&L straight through joints (epoxy) for LT underground cale including joint kits suitable for aluminium conductor cable of size 10 Sqmm to 120 Sqmm (3.5/4 core)complete all as specified and directed.
M&L outdoor/indoor type LT end termination joints heat shrink kits for LT undergroound cable sutiable for aluminium XLPE low tension under ground cable of size 10 sqmm to 120 Sqmm (2/3.5/4 core) complete all as specified and directed.
Taking out/dismantling of Old unsv LT joint end termination/strainght through form under gorund cable and LT panel/Feeder Pillar Box complete all as specified and directed.
Trimming / cutting tree branches with clearing space upto 2 meter from the over head conductor system all around for LT distriution system all as specified and directed. Note:- (i) Contractor shall take electric shutdown before stat the wrok form main station and start line after triming of tree and informed to the JE Engineer-in-charge. (ii) Photographic evidance shall be submitted by contractor alongwith RAR duly signed by concered JE and Engs-in-Charge.
M&L for cleaning of vegitation of around LT panel 5 Meter all side and welding of hinge and locking arrangement of LT incluing painting of LT Panel with two coat of paint (suitable colour match to the LT Panel) with spray painting over a coat of red oxide primer complete all as specified and directed.
S&F in replacement of Busbar Chamber in CRCA MS Sheet made out of 3.15 mm thick sheet 100 Amp, 4 Way 415 Volts of aluminium bus bar drilled holes including cadmium coated nuts, bolts, washers etc fixed on wall complete all as specified and directed.
S&F in replacement of Busbar Chamber in CRCA MS Sheet made out of 3.15 mm thick sheet 200 Amp, 4 Way 415 Volts of aluminium bus bar drilled holes including cadmium coated nuts, bolts, washers etc fixed on wall complete all as specified and directed.
Disconnecting and dismantling of existing serviceable under gorund cable of size 10 Sqmm to 120 Sqmm 2/3.5/4Core from LT panel/FPB and taking out cable/cable loop from undergorund by excavation of soft/loose soil and insertion of end termination heat shrinckable joint with PVC colour sleeves on cable of size 10 Sqmm to 120 Sqmm of 2/3.5/4 Core and crimping with suitable size of cable glands/thimble as required and refixing the same in its origina position complete all as specifed and directed. Note : Heat Shrinkable end termination joit and straight through joint (epoxy) will be paid separately under relevant item.
M/S CHAUHAN ELECTRIC WORKS (BID ID -3215923)
M/S BEE ESS ENTERPRISES (BID ID -3215354)
M/s Dinesh Kumar (BID ID -3216436)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .