11 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by the tenderer/Contractor. For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Name of the work: -Chennai Division-Electrical arrangements for variousworks as per (List of Works Enclosed)
ME-29-II-1104-2026~SR
ME-29-II-1104-2026
Open
Works - General
120 Days
Chennai, Tamil Nadu
₹0
₹64,300
27 Aug 2026
6 Aug 2026
13 Aug 2026
86 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 32,13,845 | ||
| — | — | — | Above/ 466560.00 Below/P | ||
| a)Excavation of Cable trench in all kinds ofsoils duly removing all obstructions in theway of cable trench, dumping at embankmentsite within railway land complete as perspecificationenclosed and in a manner as directed by theSection Engineer in charge at site. NOTE:The Section Engineer, in charge at site, willindicate the route of cable trench. b)Re-fillingof trench with excavated earth, ramming,consolidation and bringing back the surface tooriginal conditioncomplete in a manner as directed by theSection Engineer in charge at site. | — | 1920.00 | — | — | |
| — | — | — | Above/ 93810.00 Below/P | ||
| Demolishing plain cement concrete in platformor elsewhere, disposal of materialAtleast 6m away from track centre withinrailway land by saw cutting/breaker as per siteconditions to avoid any damage to nearby sitecomplete in a manner as directed by theSection Engineer incharge at site | — | 177.00 | — | — | |
| — | — | — | Above/ 1179528.00 Below/P | ||
| Supply and provision of mass concrete forplatforms or elsewhere with 1:2:4 ratiousing 20mm graded blue metal complete in amanner as directed by the Section Engineerinchargeat site.NOTE:i)Cement shall be Ordinary Portland Cement,43 grade, conforming to IS: 456 orlatest.ii)Proper compaction of cement concrete shallbe ensured as per standard industrialpractices.iii)The finished level should match withsurface level properly | — | 177.00 | — | — | |
| — | — | — | Above/ 81600.00 Below/P | ||
| Laying/leading of 4 core 25 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on walls andterminating in as many ends using suitablesingle compression cable glands, lugs ,sockets and other items required complete asper site conditions in a manner complete asdirected by Section Engineer in charge at site.Note:- 4Cx25 sq.mm LTUG Aluminium Cablealone will be supplied departmentally. | — | 3400.00 | — | — | |
| — | — | — | Above/ 69600.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on walls andterminating in as many ends using suitablesingle compression cable glands, lugs ,sockets and other items required complete asper site conditions in a manner complete asdirected by Section Engineer in charge at site.Note:- 4Cx35 sq.mm LTUGAluminium Cable alone will be supplieddepartmentally. | — | 2400.00 | — | — | |
| — | — | — | Above/ 24000.00 Below/P | ||
| Laying/leading of 4 core 50 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on walls andterminating in as many ends using suitablesingle compression cable glands, lugs ,sockets and other items required complete asper site conditions in a manner complete asdirected by Section Engineer in charge at site.Note:- 4Cx50 sq.mm LTUGAluminium Cable alone will be supplieddepartmentally. | — | 800.00 | — | — | |
| — | — | — | Above/ 21600.00 Below/P | ||
| Laying of 50 mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members of platformshelter or elsewhere using suitable GI fixingarrangements and couplers and otheraccessories required at appropriate locationsas per site conditions so that cable can beeasily inserted and removed wherever needarises complete in a manner as directed bySenior Section Engineer-in-charge at site.Note: 50mm dia HDPE pipe alone will besupplied departmentally | — | 800.00 | — | — | |
| — | — | — | Above/ 139200.00 Below/P | ||
| Laying of 63 mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members of platformshelter or elsewhere using suitable GI fixingarrangements and couplers and otheraccessories required at appropriate locationsas per site conditions so that cable can beeasily inserted and removed wherever needarises complete in a manner as directed bySenior Section Engineer-in-charge at site.Note: 63mm dia HDPE pipe alone will besupplied departmentally. | — | 4800.00 | — | — | |
| — | — | — | Above/ 71980.00 Below/P | ||
| Installation, Testing and Commissioning of theLT Earthing arrangements duly by excavating/auguring of earth pit in all kinds of soil/concretesurface or elsewhere, construction of masonryearth pit enclosure, provision of cover etc,complete including supply / leading / laying /burying and concealing of GI strip 32 X 6 mmalong with proper sleeve from earth electrodeto proposed MDB / SDB or elsewhere and in amanner as directed by Senior SectionEngineer in charge at site.Note:1) Masonry earth pit enclosure and cover shallbe as per drawing numberEL/P/TYPE/1022.2) LT Earthing Electrode alone will be suppliedDepartmentally. | — | 61.00 | — | — | |
| — | — | — | Above/ 10850.00 Below/P | ||
| Drawing of inside mains using 4 runs of 10 sq.mm [from MCB DB to switch boards andfrom switch boards to switch boards / orelsewhere] multistranded copper conductorcables duly inside the PVC conduit concealed/ laid vide item No. 15 below complete as perthe specification enclosed and in a manner asdirected by Senior Section Engineer in chargeat site.Note: - 4 runs of 10 sq. mm copper cableare taken as 1m for quantity purpose andwill be supplied Departmentally | — | 350.00 | — | — | |
| — | — | — | Above/ 7150.00 Below/P | ||
| Drawing of inside mains using 2 runs of 6 sq.mm [from MCB DB to switch boards andfrom switch boards to switch boards / modularfurniture or elsewhere] multistranded copperconductor cables duly inside the PVC conduitconcealed / laid vide item No. 14 belowcomplete as per the specification enclosedand in a manner as directed by Senior SectionEngineer in charge at site.Note: - 2 runs of 6 sq. mm copper cable aretaken as 1m for quantity purpose and willbe supplied Departmentally | — | 550.00 | — | — | |
| — | — | — | Above/ 61945.00 Below/P | ||
| Drawing of inside mains using 2 runs of 4 sq.mm [from MCB DB to switch boards andfrom switch boards to switch boards / modularfurniture or elsewhere] multistranded copperconductor cables duly inside the PVC conduitconcealed / laid vide item No. 14 belowcomplete as per the specification enclosedand in a manner as directed by Senior SectionEngineer in charge at site.Note: - 2 runs of 4 sq. mm copper cable aretaken as 1m for quantity purpose and willbe supplied Departmentally | — | 4765.00 | — | — | |
| — | — | — | Above/ 15600.00 Below/P | ||
| Drawing of inside mains using 2 runs of 2.5 sq.mm [from MCB DB to switch boards and fromswitch boards to switch boards / modularfurniture or elsewhere] multistranded copperconductor cables duly inside the PVC conduitconcealed / laid vide item No. 14 belowcomplete as per the specification enclosedand in a manner as directed by Senior SectionEngineer in charge at site.Note: - 2 runs of 2.5 sq. mm copper cableare taken as 1m for quantity purpose andwill besupplied Departmentally | — | 1200.00 | — | — | |
| — | — | — | Above/ 223160.00 Below/P | ||
| Concealing of 25mm dia rigid PVC conduitsalong with all accessories and includingcutting/ chipping the wall/ceiling or elsewhereand making good the same includingreplastering and painting wall to originalcondition /clamped at regular intervals, notexceeding 500 mm in a manner as directed bySection Engineer in charge at site and as perspecification for wiring/ rewiring enclosed.[Approximate length of PVC conduit]Note: 25 mm dia PVC conduitpipe,Bends,Junction Boxes alone will besupplied Departmentally | — | 7970.00 | — | — | |
| — | — | — | Above/ 6000.00 Below/P | ||
| Concealing of 32mm dia rigid PVC conduitsalong with all accessories and includingcutting/ chipping the wall/ceiling or elsewhereand making good the same includingreplastering and painting wall to originalcondition /clamped at regular intervals, notexceeding 500 mm in a manner as directed bySection Engineer in charge at site and as perspecification for wiring/ rewiring enclosed.[Approximate length of PVC conduit]Note: 32 mm dia PVC conduit pipe, Bends,Junction Boxes alone will be suppliedDepartmentally | — | 200.00 | — | — | |
| — | — | — | Above/ 102408.00 Below/P | ||
| Drawing of earth wire using 1.5 sq.mm PVCinsulated copper conductor cables dulyalong wires vide item No's 11,12,13 above andlight and fan points vide item No's 18 and 19below or elsewhere complete in a manner asdirected by Senior Section Engineer in chargeat site.Note: 1.5 sq.mm copper cable alone will besupplied departmentally. | — | 12801.00 | — | — | |
| — | — | — | Above/ 1600.00 Below/P | ||
| Drawing of earth wire using 4 sq.mm PVCinsulated copper conductor cables duly alongwires vide item No's 10 above or elsewherecomplete in a manner as directed by SeniorSection Engineer in charge at site.Note: 4 sq.mm copper cable alone will besupplied departmentally. | — | 200.00 | — | — | |
| — | — | — | Above/ 289836.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Mediumpoint i.e. length between 3 to 6 mtr] by supplyand drawing of 2 runs of 1.5 sq. mm FireRetardant Low Smoke PVC insulated coppermulti- stranded copper cables of 1100 V grade[conforming to IS: 694/1990 or latest] dulyinside the PVC conduit concealed vide itemNo. 14 above complete with provision of 6 AModular type switch conforming to IS:3854/1997 or latest, 1 No. 3 plate ceiling roseconforming to IS: 371/1999 or latest and withall standard accessories complete and in amanner as directed by Section Engineer incharge at site. | — | 996.00 | — | — | |
| — | — | — | Above/ 11010.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Longpoint i.e. length between 6 to 9 mtr] by supplyand drawing of 2 runs of 1.5 sq. mm FireRetardant Low Smoke PVC insulated coppermulti stranded copper cables of 1100 V grade[conforming to IS: 694/1990 or latest] dulyinside the PVC conduit concealed vide itemNo. 14 above complete with provision of 6 AModular type switch conforming to IS:3854/1997 or latest, 1 No. 3 plate ceiling roseconforming to IS: 371/1999 or latest and withall standard accessories complete and in amanner as directed by Section Engineer incharge at site. | — | 30.00 | — | — | |
| — | — | — | Above/ 1512.00 Below/P | ||
| Installation ,Testing and commissioning ofmodular frame plate with matching cover plateincluding and suitable for 12 modules,switches, sockets, blank plates etc. dulyaccommodated onto suitable modular switchboard box complete and recess mounting/concealing the same onto the wall usingsuitable fixing arrangements including cutting/chipping/ making recess on the wall orelsewhere including all wiring works completeincluding replastering painting etc. completeand in a manner as directed by Senior SectionEngineer in charge at site.Note: -12 module Frame plate withmatching cover plate, switch, socket andModular GI box alone will be SuppliedDepartmentally. | — | 8.00 | — | — | |
| — | — | — | Above/ 1488.00 Below/P | ||
| Installation ,Testing and commissioning ofmodular frame plate with matching cover plateincluding and suitable for 8 modules, switches,sockets, blank plates etc. duly accommodatedonto suitable modular switch board boxcomplete and recess mounting/ concealing thesame onto the wall using suitable fixingarrangements including cutting/ chipping/making recess on the wall or elsewhereincluding all wiring works complete includingreplastering painting etc. complete and in amanner as directed by Senior SectionEngineer in charge at site.Note: -8 module Frame plate with matchingcover plate, switch, socket and Modular GIbox alone will be Supplied Departmentally. | — | 8.00 | — | — | |
| — | — | — | Above/ 6105.00 Below/P | ||
| Installation ,Testing and commissioning ofmodular frame plate with matching cover plateincluding and suitable for 6 modules, switches,sockets, blank plates etc. duly accommodatedonto suitable modular switch board boxcomplete and recess mounting/ concealing thesame onto the wall using suitable fixingarrangements including cutting/ chipping/making recess on the wall or elsewhereincluding all wiring works complete includingreplastering painting etc. complete and in amanner as directed by Senior SectionEngineer in charge at site.Note: -6 module Frame plate with matchingcover plate, switch, socket and Modular GIbox alone will be Supplied Departmentally. | — | 37.00 | — | — | |
| — | — | — | Above/ 1520.00 Below/P | ||
| Installation ,Testing and commissioning ofmodular frame plate with matching cover plateincluding and suitable for 4 modules, switches,sockets, blank plates etc. duly accommodatedonto suitable modular switch board boxcomplete and recess mounting/ concealing thesame onto the wall using suitable fixingarrangements including cutting/ chipping/making recess on the wall or elsewhereincluding all wiring works complete includingreplastering painting etc. complete and in amanner as directed by Senior SectionEngineer in charge at site.Note: -4 module Frame plate with matchingcover plate, switch, socket and Modular GIbox alone will be Supplied Departmentally. | — | 16.00 | — | — | |
| — | — | — | Above/ 10830.00 Below/P | ||
| Installation, Testing and commissioning oftime switch assembly comprising of: -a)1 No. timer switch with daily setting similar toL&T catalogue reference J648B1 [FM1Quartz].b)1 No. 3 pole 25A power contactorconforming to IS: 13947/P4/1993 or latest,c)1 No. 40A DP [MCB type] isolatorconforming to IS: 13947/P3/1993 or latest,d)1 No. Neutral link etc.e)1 No. Earth link etc.f) Suitable rated control fusesall duly pre-wired and mounted on anappropriate sized well-seasoned woodenplank of thickness not less than 12 mm andduly housed into and powder coat finishedenclosure of size not less than 300mm X450mm X 300mm and made of 2mm thickSheet Steel complete and provision of thesame onto the wall or elsewhere using suitablefixing arrangements complete and in amanner as directed by Section Engineer incharge at site.Note:Timerswitch,Powercontactor,MCB,Neutral Link,Earthlink,fuses,wooden box,enclosures alonewill be supplied Departmentally. | — | 19.00 | — | — | |
| — | — | — | Above/ 2516.00 Below/P | ||
| Erection, Testing and commissioning of 63kVA SMC DT Metering Box of dimensionH=700mm,W=480mm,D=210mm including allcabling and wiring terminations at bothincoming and outgoing ends and usingsuitable fixing and mounting arrangementscomplete as per industrial standards as persite conditions is a manner as directed bySection Engineer in charge at siteNote: SMC DT Metering Box alone will besupplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 1480.00 Below/P | ||
| Installation,Testing and commissioning of the300mm sweep BLDC Exhaust fan onto thebuildings or elsewhere using suitable clampingand fixing arrangement complete as perindustrial practices including supplyconnection from ceiling rose by using 3 core1.5 sq. mm fire retardant Low smoke PVCinsulated, PVC round sheathed copper [White/ Ivory colour] conductor flexible pendant chordconforming to IS:694/1990 or latest completeas per industrial standards and in a manner asdirected by Senior Section Engineer in chargeat site.Note: 300mm sweep BLDC Exhaust fanalone will be supplied departmentally. | — | 8.00 | — | — | |
| — | — | — | Above/ 8987.00 Below/P | ||
| Installation, Testing and commissioning of1200mm sweep BLDC ceiling fan onto thebuildings or elsewhere using suitable clampingand fixing arrangement complete as perindustrial practices including supplyconnection from ceiling rose by using 3 core1.5 sq. mm fire retardant Low smoke PVCinsulated, PVC round sheathed copper [White/ Ivory colour] conductor flexible pendant chordcomplete in a manner as directed by SeniorSection Engineer in charge at site.Note: 1200mm sweep BLDC Ceiling fanalone will be supplied departmentally. | — | 43.00 | — | — | |
| — | — | — | Above/ 70900.00 Below/P | ||
| Installation, Testing and commissioning of 4feet 20W LED light fitting Batten type suitableto work on 240V single phase 50 Hz AC withlamp and all standard accessories usingsuitable mounting and fixing arrangement asper industrial practices including supplyconnection from ceiling rose by using 3 core1.5 sq. mm Fire Retardant Low Smoke PVCinsulated, PVC round sheathed copper[White/Ivory colour] conductor flexible pendantchord conforming to IS:694/1990 or latestcomplete as per industrial standards and in amanner as directed by Senior SectionEngineer in charge at site.Note: 4 feet LED 20W light fitting BattenType with lamp alone will be suppliedDepartmentally | — | 709.00 | — | — | |
| — | — | — | Above/ 14511.00 Below/P | ||
| Installation, Testing and commissioning ofSPN MCB DB's withDP/FP,MCB/RCCB,RCBO as Incomer alongwith combination of No's of SP/DP/TP/FP,MCB's as feeder controls along with Cableadaptor box on to the wall using suitable angleiron frame work and including cutting/chippingand re-plastering and bringing back walls tooriginal condition including painting the wallsto original condition complete including allcabling and termination works at bothincoming and outgoing ends complete as persite conditions and as per industrial practicesin a manner as directed by Senior SectionEngineer in charge at site.Note: MCB DB,MCB, Cable adaptor box etcalone will be supplied Departmentally | — | 21.00 | — | — | |
| — | — | — | Above/ 3300.00 Below/P | ||
| — | 4.00 | — | — | ||
| Testing Cable adaptor and to original endscomplete charge at | : - Installation, with40A/63A/100A,FP,RCBO/MCCB/RCCB alongwith the walls and outgoing in | and asIncomer box on to the re-plastering and conditioncomplete and as per site.Note: MCB | MCB DB's ofSP/DP/FP,MCB's iron frame work original condition terminationworks as directed etc alone | ||
| — | — | — | Above/ 48516.00 Below/P | ||
| Installation, Testing and commissioning of 45W LED street fittings using suitable GI tubularmounting arm bent to act as tubular support foranchoring arrangement onto walls includingsupply connection from ceiling rose/junctionbox or elsewhere by using 3 core 1.5 sq. mmFire retardant low smoke PVC insulated, PVCround sheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrialstandards in a manner as directed by SectionEngineer in charge at site.Note: 45W LED street light fittings alonewill be supplied departmentally | — | 311.00 | — | — | |
| — | — | — | Above/ 5250.00 Below/P | ||
| Installation, Testing and commissioning ofSMC box assembly similar to SintexCatalogue reference No.GSJB-3020 alongwith strip connector block, Neutral link, fusebases and carriers onto lamp posts orelsewhere suing suitable clampingarrangements complete and in a manner asdirected by Section Engineer in-charge at siteNote: SMC GSJB-3020 box, stripconnector, neutral link, Earth link,Fuse bases and fuse carriers, MSclamping arrangements alone will besupplied Departmentally. | — | 42.00 | — | — | |
| — | — | — | Above/ 3192.00 Below/P | ||
| Installation, Testing and commissioning of 63A, FP,MCCB with Enclosure onto wall orelsewhere using suitable angle iron framework and mounting and fixing arrangementsas per industrial standards including all wiringand cable termination works at both Incomingand outgoing sides complete in a manner asdirected by Section Engineer in charge at site.Note: 63A, FP, MCCB with Enclosure alonewill be supplied Departmentally. | — | 21.00 | — | — | |
| — | — | — | Above/ 200.00 Below/P | ||
| Installation, Testing and commissioning of32A, DP, MCB with Enclosure onto wall orelsewhere using suitable angle iron framework and mounting and fixing arrangementsas per industrial standards including all wiringand cable termination works at both Incomingand outgoing sides complete in a manner asdirected by Section Engineer in charge at site.Note: 32A, DP, MCB with Enclosure alonewill be supplied Departmentally | — | 4.00 | — | — | |
| — | — | — | Above/ 50043.00 Below/P | ||
| Erection, Testing and commissioning of 5HPNon clog submersible sewage pump setcomplete with control panel suitable foroperation on three phase AC supply along withall accessories including fixing and mountingarrangements and other items required forsuccessful commissioning of pump completeas per site conditions and as per industrialstandards in a manner as directed by Sectionengineer in charge at site.Pipe Required asper site conditions upto length of 5m is coveredunder contractor's scopeNote:5 HP Non Clog Submersible Sewagepump with Control panel assembly alonewill be supplied Departmentally | — | 21.00 | — | — | |
| — | — | — | Above/ 27600.00 Below/P | ||
| Erection, Testing and commissioning of 3HPNon clog submersible sewage pump setcomplete with control panel suitable foroperation on three phase AC supply along withall accessories including fixing and mountingarrangements and other items required forsuccessful commissioning of pump completeas per site conditions and as per industrialstandards in a manner as directed by Sectionengineer in charge at site. Pipe Required asper site conditions upto length of 5m is coveredunder contractor's scopeNote:3 HP Non Clog Submersible Sewagepump with Control panel assembly alonewill be supplied Departmentally | — | 15.00 | — | — | |
| — | — | — | Above/ 1600.00 Below/P | ||
| Laying/Leading of 3 core 4 sq. mm PVCinsulated copper conductor flat submersiblecable including water proofing terminations,joints and connecting upto panels in a manneras directed by Section Engineer in charge atsiteNote: 3 core 4 sq.mm PVC Cable alone willbe supplied Departmentally | — | 200.00 | — | — | |
| — | — | — | Above/ 2752.00 Below/P | ||
| Supply, Installation, Testing andcommissioning of metal junction box(switchboard of size 200mmx150mmx50mmfabricated with 16 gauge steel an provided with3mm thick decolam sheet top, knockout, andrecess mounting/ concealing the same ontothe wall using suitable fixing arrangementsincluding cutting/ chipping/ making recess onthe wall or elsewhere including including allwiring works complete replastering paintingetc., complete and in a manner as directed bySenior Section Engineer in charge at site | — | 16.00 | — | — | |
| — | — | — | Above/ 1676.00 Below/P | ||
| Installation, Testing and commissioning of 0-60A CT operated Multifunction Energy Meterwith Enclosure onto wall or elsewhere usingsuitable angle iron frame work and mountingand fixing arrangements complete including allwiring and Cable termination works at bothincoming and outgoing ends complete as perindustrial standards and in a manner asdirected by Section Engineer in charge at site.Note: 0-60A CT operated Multi FunctionMeter with Enclosure alone will besupplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 49400.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3runs of 6 sq. mm [from MCB DB to switchboards and from switch boards to switchboards / modular furniture or elsewhere] fireretardant Low smoke PVC insulatedunsheathed multi-stranded copper conductorcables conforming to IS:694/1990 or latestduly inside the PVC conduit laid vide 40) b)below complete as per the specificationenclosed and in a manner as directed bySenior Section Engineer in charge at site.b) Supply and Concealing of 25mm dia rigidPVC conduits [IVORY colour] along withsuitable bends,Junction Boxes,clamps and allaccessories and including cutting/ chipping thewall/ceiling or elsewhere and making good thesame including replastering and painting wallto original condition /clamped at regularintervals, not exceeding 500 mm in a manneras directed by Section Engineer in charge atsite and as per specification for wiring/ rewiringenclosed. [Approximate length of PVC conduit]Note 1: - 3 runs of 6 sq. mm copperconductor and 1 m of 25mm dia PVCconduit pipe are taken as 1m for quantitypurposeNote 2: Bends,JunctionBoxes,Clamps,Screws and other itemsrequired for successful concealing of25mm dia PVC conduit pipe at fixedintervals ,site conditions and as perdirections of Section Engineer incharge atsite is covered under contractors scope ofwork. | — | 200.00 | — | — | |
| — | — | — | Above/ 19000.00 Below/P | ||
| a)Supply and Drawing of inside mains using 3runs of 4 sq. mm [from MCB DB to switchboards and from switch boards to switchboards / modular furniture or elsewhere] fireretardant Low smoke PVC insulatedunsheathed multi-stranded copper conductorcables conforming to IS:694/1990 or latestduly inside the PVC conduit laid vide 41) b)below complete as per the specificationenclosed and in a manner as directed bySenior Section Engineer in charge at site.b) Supply and Concealing of 25mm dia rigidPVC conduits [IVORY colour] along withsuitable bends,Junction Boxes,clamps and allaccessories and including cutting/ chipping thewall/ceiling or elsewhere and making good thesame including replastering and painting wallto original condition /clamped at regularintervals, not exceeding 500 mm in a manneras directed by Section Engineer in charge atsite and as per specification for wiring/ rewiringenclosed. [Approximate length of PVC conduit]Note 1: - 3 runs of 4 sq. mm copperconductor and 1 m of 25mm dia PVCconduit pipe are taken as 1m for quantitypurposeNote 2: Bends,JunctionBoxes,Clamps,Screws and other itemsrequired for successful concealing of25mm dia PVC conduit pipe at fixedintervals ,site conditions and as perdirections of Section Engineer incharge atsite is covered under contractors scope ofwork. | — | 100.00 | — | — | |
| — | — | — | Above/ 4030.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Mediumpoint i.e. length between 3 to 6 mtr] by supplyand drawing of 3 runs of 1.5 sq. mm FireRetardant Low Smoke PVC insulated coppermulti- stranded copper cables of 1100 V grade[conforming to IS: 694/1990 or latest] alongwith a)Supply and Concealing of 25mm diarigid PVC conduits [IVORY colour] along withsuitable bends,Junction Boxes,clamps and allaccessories and including cutting/ chipping thewall/ceiling or elsewhere and making good thesame including replastering and painting wallto original condition /clamped at regularintervals, not exceeding 500 mm in a manneras directed by Section Engineer in charge atsite and as per specification for wiring/ rewiringenclosed.b) Supply and provision of 6 A Modular typeswitch conforming to IS: 3854/1997 or latest,c)Supply and provision of 1 No. 3 plate ceilingrose conforming to IS: 371/1999 or latest andwith all standard accessories completerequired as per site conditions and in a manneras directed by Section Engineer in charge atsite. | — | 10.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SpecialconditionsofContractElectrical12months_1.pdf SPL CON for CONTRACT ELECRICAL
ATTACHMENT
ModelformofBGbondwithinstructions.pdf
ATTACHMENT
Checklist.pdf
ATTACHMENT
GCCIRSGCC1-11_compressed12.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
GeneralinstructionstoTenderers12months.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
Earthing.pdf
ATTACHMENT
EarthingType1032.pdf
ATTACHMENT
ListofWorks.pdf
ATTACHMENT
MCBDrawing.pdf
ATTACHMENT
SpecificationforlayingUndergroundcable.pdf
ATTACHMENT
specificationforwiringandrewiring.pdf
ATTACHMENT
TenderScheduleQtyBreakupDetails.pdf
ATTACHMENT
SpecialconditionsofContractElectrical12months_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .