Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L1 | Accepted-AOC QUOTED LOWEST RATE | |
| 2 | L2₹28.6 L+₹2.2 L (8.48%)Rejected-Finance | L2 | Rejected-Finance QUOTED HIGH RATE |
Tender Value
₹32.3 L
EMD Value
₹65,000
Closing Date
20 Jan 2024, 6:00 pmClosed
CWE AF JAISALMER
AIRFORCE STATION JAISALMER RAJASTHAN
SPECIAL REPAIR TO BIDG NO P6 P7 AND IMPROVEMENT TO BLDG NO P104 P105 AT AIR FORCE STATION MOUNT ABU
2023_MES_633275_1
80282
Open Tender
Civil Works
Item Rate
300 days
AGE (I) (AF) MOUNT ABU
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) AF MOUNT ABU
₹65,000
Yes
7 Mar 2024
18 Dec 2023
22 Jan 2024
18 Dec 2023
20 Jan 2024
8 Jan 2024
Amount
Taking down chowkhats or frame not exc 1.50 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.50 & n.exc. 4 sqm in each complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar complete all as specified and as directed.
Taking down cement plaster of any description, on brick or stone or PCC block masonry walls/ceiling etc. including raking out joints, hacking for key, scrubbing down with water etc and including removing debris/rubbish from the premises upto 500m from site complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or any thickness, pointed in any mortor or any height in floors, aprons etc laid bedded & pointed in any mortar complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position/height not exceeding 15cm thickness (below or above ground level) and including removing debris/rubbish from the premises upto 500m outside the MoD land complete all as specified and directed.
Dismantling of existing APP water proofing treatment with plaster, concrete works of any location on existing RCC roof slab by chiesling,drilling,scraping etc. and including removing debris/rubbish from the premises upto 500m from site complete all as specified and directed.
Cleaning of roof slabs/chajjas by sweeping with brooms, removing all depositions/mud/ vegetations etc complete all as specified and directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry (1:3) complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections and fittings, including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections and fittings, including cleaning for refixing or removal from site complete all as specified and directed.
Dismantling wrought iron/mild steel work/stainess steel posts, baiiuster top railing as in staircase railing, etc complete all as specified and as directed.
M&L for 25mm thick plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in Roof padding on roof for correction of slope, levelling coarse, roof kerbs of mud stops or similar works, etc complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in floors and drain finishing the surface even and smooth with using extra cement complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4 type B0 (12.5mm graded aggregate) as in louvres and jallies,35mm thick (measured solid), set in CM 1:4 including all mouldings complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/hard standing finished even and fair surfaces.
M&L for brick work built in cement mortar (1:6) using sub class 'B' old size bricks curved or straight in plan exc 6m mean radius complete all as specified and directed.
M&L for 10mm thick rendering cement plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering cement plaster in cement mortar (1:4) with water proofing compound on surfaces of fair faces of brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. ( water proofing compound shall be measured and paid separately as supply only).
M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick cement screed in cement mortar 1:3, including finishing even and smooth with out using extra cement to receive roof treatment, mixed with liquid water proofing compound mixed as per manufacture instruction by weight of cement over cleaned roof surface, as in grading to RCC roof surface,complete all as specified and directed. Note- Water proofing compound shall be measured and paid separately as supply only).
Supply only water proofing compound, make as approved by GE complete all as specified and directed.
M&L for preparing new plaster surfaces and applying 1mm thick readymixed wall putty on entire surface of wall etc cutting and finishing with appropriate sand paper and applying two coat of oil bound distemper (White or tinted) over one coat of primer after smoothening of surfaces of wall complete all as specified and directed.
M&L for preperation of new plastered surfaces by brooming down and steel wire brushing, scrapping, down smoke soot, and greasy spot etc, and applying two coats of plastic exterior emulsion paint over a coat of primer on surfaces of walls any colour as approved by GE complete all as specified and directed.
M&L for preparing new plaster surfaces by scrapping and washing and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparing Old decorative surfaces of any description and applying two coats of white wash on ceiling complete all as specified and directed.
M&L for complete removal of existing treatment on old decorative surfaces, filling up undulation and applying 3.0mm thick readymixed wall putty on entire surface of wall etc cutting and finishing with appropriate sand paper and applying two coat of oil bound distemper (White or tinted) over one coat of primer after smoothening of surfaces of wall complete all as specified and directed.
M&L for preperation of old decorative surfaces of any description and applying two coats of plastic exterior emulsion paint over a coat of primer on surfaces of walls any colour as approved by GE complete all as specified and directed.
M & L preparing new wood & wood based surfaces and applying two coats of synthetic enamel paint over a coat of pink primer, exc 10cm width or girth complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20mm thick over and including 20mm thick cement morter 1:4 screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone slabs 18-20mm thick as in skirting/dado over and including 15mm thick cement morter 1:4 jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20mm thick Granite (of any type) tiles, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 20mm thick screed of beding layer in cement plaster (1:4) complete complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors etc over and including 15mm thick screed bedding in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
M&L for coloured printed ceramic tiles area of each tile exceeding 0.18 but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete to match in floor over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed.
M&L for 300mmx450mmx7 to 8mm thick coloured glazed ceramic tiles as in vertical surfaces such as skirting, dado, etc. over and including 10mm thick bedding layer in CM 1:4 set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and directed.
M&L for Vitrified Ceramic tiles light shade 9 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 1.00 sqm, in floors etc. over and including 15mm thick screed bedding in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Chequered PVC Moulded cement concrete tiles dark shade 30 cm x 30 cm x 22 mm thick set , jointed and pointed in neat cement slurry in floors with gray cement and pigment with screed bed 15 mm CM 1:6 complete all as specified by Engr- in- Charge
M&L for preparing new surfaces of roof/wall and applying two coats of Colour Polyurethene (PU) acrylic based Water proofing liquid compound over and including a coat of diluted elastomeric self primer with reinforcing fabric sheet as per manufacturer's instruction to stop leakage/seepage from roof/wall complete all as specified and directed. Note :- Unit rates quoted by the contractor shall be deemed to be included for work in buildings/ structure of any height.
M&L for powder coated anodised aluminium sliding window & ventilator in three track of size 63.50 x 38.5 x 1.8 mm thick fixed on a powder coated Aluminium frame of size 63.5 x 46 x 1.2 mm with Stainless steel wire mesh of 0.36 mm dia with aperture of 1.40mm fixed with aluminium F chanal including provision of 5.5mm thick Sheet glass fixed with powder coated aluminium snap and rubber beading complete all as specified and directed. Note:- (a) Aluminium anodised spring to be locking device 02 Nos of 100 mm long in each window. (b) Aluminium eye hook/stopper in each leaf. (c) Two sliding shutters of glass and one sliding shutter of SS wire mesh
S&F powder coated aluminium anodized grill of 6/7 mm dia rod square, rectangular, circular or similar type of shape, fixed with channel 38 mm x 12 mm x 1.30 mm (Sec No 8778) complete all as specified and directed.
S&F Aluminium doors shutters air tight with natural anodized alunimium frame with on or more rebate partly glazed and partly panelled of with hollow profile PVC panelling of thickness 12mm (all aluminium member Top, bootom, vertical & middle of shutter made of size 82.55x44.45x1.80mm thick including necessary jointing cleats, glazing clips, 5mm thick tinted glass, rubber packing with anodized aluminium beading /glazing clip size 19.00x17.30x0.70mm, wt 0.097 Kg/RM of both side and fixing aluminium fittings i.e aluminium hinges 100mm three numbers, handles 200mm long two numbers, tower bolts 150mm two numbers and mortic lock with 06 lever fitting shoiuld be ISI marked complete in all respect as Engr-in-Charge. (Rates will also include making good floor /wall jambs of doors/ windows surface with plaster and match with existing finishes) Make of aluminium : hindalco, Jindal, Indalco.
S&F 35 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc (without sash bars) fitted with cut and mitred securing beads for securing glass etc complete as specified and directed sizes of members of shutters as specified in SSR Part I Section 8 clause 8.24 (a).
S&F Solid PVC Double door frame of size Solid PVC Double door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter With Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F Stainless steel (Grade SS-304) wire cloth 0.36mm nominal dia of wire and average width of aperture1.4mm and fixed with stainless steel wire staple fixed with aluminium beading etc complete all as specified and as directed.
S&F Aluminium alloy anodised sliding door bolt with hasp&staple ( bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and as directed.
S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised complete all as specified and as directed.
S&F aluminium alloy butt hinges 100 mm long, for PVC door complete all as specified and directed.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section as per specified and directed.
S&F 150 mm size, Aluminium handles, cast type, anodised as per specified and directed.
S&F in repair for Anodised Aluminium snap grid frame work with size of grid 605x605mm for false celing all as spacified including dismantling existing board existing frame work complete all as specified and directed.
S&F Gypsum board of 12mm thick for false ceiling complete as per specified and directed.
S&F in repair of 25mm Harrison rails (Curtain rails) of anodised aluminium alloy chromium with fixing brackets stops, rollers etc complete all as specified and as directed.
S&F galvanised steel tubing 15mm bore (ISI) marked medium grade with necessary fittings lie tees, elbows, sockets, reducers, bends etc including necessary cutting, threading laid in trenches/floors, fixed to walls(concealed) etc complete all as specified and directed.
S&F galvanised steel tubing 20mm bore (ISI) marked medium grade with necessary fittings lie tees, elbows, sockets, reducers, bends etc including necessary cutting, threading laid in trenches/floors, fixed to walls(concealed) etc complete all as specified and directed.
S&F of 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), Tripple layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F of 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), Tripple layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F repairs Vitreous china wash down water closet pan (pedestal pattern) with any type of 'P' or 'S' trap excluding flushing cistern and flush pipe, including fixing of water closet complete with plastic water closet seat black/white closed pattern witrh flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repair water closet vitreous china squatting pan Orissa pattern of size 630x450mm white with integral foot rest front/back inlet (excluding flushing cistern and flush pipe) including provision of cement concrete bedding in PCC (1:5:10) type E2 and making good to disturb surface complete all as specified and as directed.
S&F in repairs Vitreous China wash basin, wliile, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but fixing on counter top slab including waste fitting, brass chromium plated 32 mm size with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and as directed.
S&F in repairs vitreous china half stall urinal White complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flishing cistern with brackets, flush pipe, grating and union for discharge pipe(exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
S&F in repair PVC valveless, syphonic action type, flushing cistern 10ltrs capacity, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, excluding 32 mm dia. PVC flushing pipe,complete all as specified.
S&F in repair Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
Supply only PVC connection 15mm dia 600 mm long with brass fly nut at both ends complete all as specified and directed.
S&F in repair health faucet with double lock 1.0meter brass plated stainless stell flexible hose and wall hook complete all as specified and directed.
S&F in repair 15 mm angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed of Make- Jaquar or Equvlent.
S&F in repair pillar taps , cast copper alloy with capstan heads , chromium plated , screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm complete all as specified.
S&F in repair 15 mm bore bib taps, chromium plated cast copper alloy, high pressure screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F waste coupling suitable for 32mm dia bore of discharge pipe of PTMT (half or full threated) for WHB minium weight 45 gms complete all as specified and directed.
S&F in repair grating doom 100 mm dia of PTMT (minimum weight 25gms ) complete all as specified and directed.
S&F in repair PVC (SWR) floor trap of 75 mm outlet plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repair PVC (SWR) 110 mm dia pipes single socketed in any length with rubber ring joints laid in trenches/floor or fixed to walls including digging and making good as existing complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in concrete bed for 110 mm dia PVC (SWR) pipes including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) bend any radius complete all as specified and as directed.
S&F in repair 110 mm PVC (SWR) Junction single (Single T) equal or unequal complete all as specified and as directed.
S&F in repair PVC (SWR) branch pipe, single Y equal or unequal 110mm dia complete all as specified and as directed.
S&F in repair PVC (SWR) 75 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to walls including digging and making good as existing complete all as specified and as directed.
S&F in repair 75mm dia PVC (SWR) bend any radius complete all as specified and as directed.
S&F for steel work in tubular tresses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St -240 complete all as specified and directed.
S&F Fe 410W (Gde E-250) quality A for Roof truses (framed), trussed, purlins, crane grantries, rails and fasternings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, clests etc complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (Fe-290, GdeE-165) complete all as specified and directed.
S&F joist channel angle, tee sections, MS pipe, MS square tube ,bars , MS plate fixed in purlin rafter cleat, support etc incl welding, riveting etc conf to Fe-410-W Gde E-250 quality-A complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed self tapping screws complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed self tapping screws complete all as specified and directed.
S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges,hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide zinc chrome complete all as specified and directed.
Taking down carefully aluminium point wiring on wooden battens/through conduit (light fan, socket or power) complete with fittings such as switches, wooden batten, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed.
Taking down carefully unserviceable MCB's of any type any capacity complete all as specified and as directed.
Taking down carefully unserviceable distribution board any type any capacity complete all as specified and as directed.
Takling down Ceiling/Exhaust fan/Wall fan for refixing after wiring work completed, complete all as specified and directed.
Dismantling of Split airconditioning unit of any capacity complete all as specified and directed.
Taking down carefully unserviceable submain wiring any type any rating complete all as specified and as directed.
M&L for concealed Point wiring including cutting and chasing on wall / roof surface controlled by one switch with 1.50 Sqmm (nominal area) FRLS, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable and FRLS, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, not less than 1.50mm thick, drawn through in and including rigid PVC conduit (Medium Grade) of suitable size, with all fittings, ISI marked and accessories, the pipe shall be fixed with clamping and shadle including provision of mild steel terminal boxes/Sunken boxes of suitable size made with 1.22 mm thick mild steel sheet recessed in wall with a coat of black bituminus paint and providing of with 3mm thick bakelite/PVC sheet ISI marked top cover , suitable for fixing of switches / sockets / regulators etc. fixed in recess of wall with brass chromium plated screws and cap washer complete all as specified and directed for the following :-
(a) One light point/exhaust fan/ceiling controlled by one switch one way & ceiling fan with one way switch & regulator.
(b) One socket out let 5/6 amps point on the same board
(c) One socket out let 5/6 amps point on the independent board
(d) One call bell point controlled by one bell push .
All as per item No 97 above but wiring with 2.5sq mm with PVC single core sheathed multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F ceiling rose, surface Bakelite 65x50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) complete all as specified and directed.
S&F Modular switch, single pole, 6 Amp, 230 V AC, one way, one module, ISI marked complete all as specified and directed.
S&F Modular switch, single pole, 16 Amp, 230 V AC, one way, one module, ISI marked complete all as specified and directed.
S&F Modular shuttered Socket outlet, 5Pin, 6A, 2 module, 230V AC, ISI marked complete all as specified and directed.
S&F Modular shuttered Socket outlet, 6Pin, 16A, 2 module, 230V AC, ISI marked complete all as specified and directed.
S&F modular Fan regulator step type, 120W, 2 module suitable for 1200/1400mm sweep energy saving fans, ISI marked complete all as specified and directed.
S&F in reapir Aesthetically designed LED panel for surface mounting which provides soft-light and glare free symmetrical illumination 34 watt, of size 2 x 2 LED light fitting, including twin core flexible copper cable for connection of the lights and connectors where required complete all as specified and directed. Make - Havells cat part No:PLANO2x2PLR34WLED865S or equivalent as approved by GE
Refixing of split Aircondtioning unit 1.5/2.0 Ton capacity in the original position with all connections and necessary fittings and fixtures complete all as specified and directed.
M & L in repair sub main wiring concealed with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLSH cable 1100 Volts grade including 6 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLSH as continuous earth 6 mm wire drawn through concealed conduit Cutting chases in stone wall , pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth and connecting to common earth terminals complete all as specified and directed. Note : Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm cable as earth continuity conductor and 25mm rigid PVC conduit shall be measured and paid as one unit.
M & L in repair sub main wiring concealed with 2 single core, 4 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLSH cable 1100 Volts grade including 4 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLSH as continuous earth 6 mm wire drawn through concealed conduit Cutting chases in stone wall , pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth and connecting to common earth terminals complete all as specified and directed. Note : Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm cable as earth continuity conductor and 25mm rigid PVC conduit shall be measured and paid as one unit.
Supply and in reapir fix sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete all as specified and directed. Note : Rates are deemed to be included for flashing in wall concealed complete making good and matching existing surface.
Supply and fix in reapir sheet metal enclosures double door, single pole and neutral, 8 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete all as specified and directed. Note : Rates are deemed to be included for flashing in wall concealed complete making good and matching existing surface.
S&F MCB, 6 to 32 Amp, SP, 240 Volt, 'C' series, having current rating 10KA, complete all as specified and directed.
S&F MCB, 32 Amp, SPN, 'C' series, having current rating 10KA, complete all as specified and directed.
S&F MCB, 40 Amp, SPN, 'C' series, having current rating 10KA, complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed.
Fixing only old serviceable of LED light fitting any type taken down alongwith wiring complete all as specified and directed.
M& L for replacement 30 W 6500K,PF>.8, new generation technology in LED,post top lantern,energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having iP65 protection and impact resistance of iK07 with 10KV Built-in surge Protection device complete all as specified and directed.
S&F Modular white cover plate with frame 2 module complete all as specified and directed.
S&F Modular white cover plate with frame 8 module with blank switches as required complete all as specified and directed.
M.S. ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .