Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LQualified | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹32.9 L+₹37,815 (1.16%)Qualified 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Qualified MSE, MII, Category: General | |
| 3 | L3₹32.9 L+₹43,376 (1.33%)Qualified | L3 | Qualified MSE, MII, Category: General | |
| 4 | L4₹33.0 L+₹53,486 (1.65%)Qualified | L4 | Qualified MSE, MII, Category: General | |
| 5 | L5₹33.0 L+₹54,585 (1.68%)Qualified 228A GILL COLONY BHAI BANNOJI MARG KHURLA KINGRA JALANDHAR PUNJAB 144003 | JALANDHAR | PUNJAB | 144003 | L5 | Qualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Aug 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
)
6766137
GEM/2024/B/5274957
Two Packet Bid
Ammeter,Frequency metre,Over current and earth fault relay digital self power relay,Microprocessor
30 days
Punjab; Jalandhar
Total value wise evaluation
BOQ
9 documents required · 9 mandatory
1 yrs
₹3
Exempted
31 Aug 2024
10 Aug 2024
31 Aug 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Ammeter | Ammeter digital type 200/5Amps & 100/5Amps suitable for HT VCB 11kV. | 2 | Each | Kamaljits6566@2 | 30 |
| 2 | Frequency metre | Frequency metre 50c/s confirming to IS 1248 as per the existing specification. | 2 | Each | Kamaljits6566@2 | 30 |
| 3 | Over current and earth fault relay digital self power relay | Over current & earth fault relay digital self power relay showing earth fault & over current etc including taking down old defective removal and modification to existing panel to fix the new relay etc complete all as specified. MAKE Crompton Greaves (Type- CG-I 14 N) or equivalent make | 3 | Each | Kamaljits6566@2 | 30 |
| 4 | Microprocessor based numerical relay with OL EF and SC protection | Microprocessor based numerical relay with O/L E/F and S/C protection suitable to work on 24 volt DC supply in renewal of any type relay including modifications to existing panel so as to accommodate the new relay complete all as specified. MAKE Schneider (Formely Areva) cat part No. Schneider MICOMP 111L without communication or equivalent make | 5 | Each | Kamaljits6566@2 | 30 |
| 5 | Trip circuit supervision relay with hand reset contacts | Trip circuit supervision relay with hand reset contacts operating voltage 24 to 27 volt DC with 03 No + 02 NC including connectingwith existing system commissioning and testing. MAKE ALSTOM cat part No. VAX 31ZG8071BCH or equivalent make | 2 | Each | Kamaljits6566@2 | 30 |
| 6 | 03x Electrician | staffing and ops of 66 KV Grid Sub Staion/11KV Substation (comprising of different equipment viz VCBs transformer SF6 LT panels battery ban isolators DG Set etc.) in 66 KV yard and control room with 66 KV incoming & 11 KV outgoing supply including maintenace of 66 KV MRS and providing comprehensive maintenance and operation of external distribution network and including immediate attending breakdown related to electric supply sorrounding area to the sub station complete all as applicable in shift not exceeding 08 hours per day on all week days including Sundays and holidays all as specified and directed by Engineer-in-Charge. | 11 | Months | Kamaljits6566@2 | 335 |
| 7 | Single element high speed tripping relay | Single element high speed tripping relay with hand reset contacts operating voltage 24 to 27 Volt DC with 02 NO + 01 NC including connecting with existing system commissioning and testing. MAKE ALSTOM cat part No. VAJH13YF0002BBA or equivalent make | 2 | Each | Kamaljits6566@2 | 30 |
| 8 | LT ACB cut off relay for 800 630 400 Amps capacity | LT ACB cut off relay for 800/630/400 Amps capacity. | 3 | Each | Kamaljits6566@2 | 30 |
| 9 | Indoor end termination joint kit | Indoor end termination joint kit (heat shrinkable) complete with jointing material and accessories suitable for 3wire 11KV (Earthed)
grade HT underground XLPE insulated armoured aluminium conductor 3core 95Sqmm size cable | 5 | Each | Kamaljits6566@2 | 30 |
| 10 | All same as per item No 9 above but of size 3 core 120 Sqmm | All same as per item No 8 above but of size 3 core 120 Sqmm | 4 | Each | Kamaljits6566@2 | 30 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_6766137.pdf
GEM_BID
lift_spec_2024-08-09-20-36-48_58e44237557dc97e6e14f33250c1058c.pdf
BOQ
boq_item_lift_2024-08-09-20-36-48_bdbe46104b422e66a156eb4ac2be2f02.csv
BOQ
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .