Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹1.7 CrSame as L1Accepted-AOC | ₹1.7 CrSame as L1 | L2 | Accepted-AOC Awarded |
| 2 | L1₹1.7 CrRejected-AOC | ₹1.7 Cr | L1 | Rejected-AOC Rejected |
| 3 | L2₹1.7 CrSame as L1Rejected-AOC VILL MAHAMAYA NAGAR P O HATSINGIMARI DIST DHUBRI ASSAM | ₹1.7 CrSame as L1 | L2 | Rejected-AOC Rejected |
| 4 | L3₹1.8 Cr+₹9.7 L (5.55%)Rejected-AOC | ₹1.8 Cr+₹9.7 L (5.55%) | L3 | Rejected-AOC Rejected |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
18 Nov 2022, 3:00 pmClosed
Chief Engineer,PWD(Border Roads NEC Works),Assam
O/o the Chief Engineer, Roads,PWRD Assam, chandmari, Guwahati-781003
MMPNA/2022-23/165 Please refer Tender documents.
2022_PWD_27472_165
CE/CMRDP/MMPNA/2022/2
Open Tender
Civil Works
Item Rate
90 days
Mankachar
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,900
₹3.9 L
Yes
O/o the Chief Engineer, Roads,PWRD Assam,chandmari
18 Mar 2023
29 Oct 2022
19 Nov 2022
29 Oct 2022
18 Nov 2022
29 Oct 2022
29 Oct 2022 - 17 Nov 2022
8 Nov 2022
Amount
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (Provided only on WBM surface)
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. Statement-3
20mm thick open graded Premix carpet using bituminous (penetration grade/ modified bitumen) Binder Providing , laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2 mm to 5.6mm aggregate eithe rusing penetration grade bitumen or emulsion to required line, grade and level to surfe as wearing course on a previously prepared base, including mixing in a suitable plan, laying and rolling with a three wheeler 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical specification clause:508 Case 1 By Manual Means (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Case I , Type A as per Technical Specification Clause:510 (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (80% length of the Road is considered),Painting of speed breaker
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801,800mm x 600mm rectangular
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (Provided only on WBM surface)
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. Statement-3
20mm thick open graded Premix carpet using bituminous (penetration grade/ modified bitumen) Binder Providing , laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2 mm to 5.6mm aggregate eithe rusing penetration grade bitumen or emulsion to required line, grade and level to surfe as wearing course on a previously prepared base, including mixing in a suitable plan, laying and rolling with a three wheeler 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical specification clause:508 Case 1 By Manual Means (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Case I , Type A as per Technical Specification Clause:510 (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (80% length of the Road is considered),Painting of speed breaker
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801,800mm x 600mm rectangular
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (Provided only on WBM surface)
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
20mm thick open graded Premix carpet using bituminous (penetration grade/ modified bitumen) Binder Providing , laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2 mm to 5.6mm aggregate eithe rusing penetration grade bitumen or emulsion to required line, grade and level to surfe as wearing course on a previously prepared base, including mixing in a suitable plan, laying and rolling with a three wheeler 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical specification clause:508 Case 1 By Manual Means (i) Bitumen (S-90),Providing Hump type speed breake
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Case I , Type A as per Technical Specification Clause:510 (i) Bitumen (S-90),Providing Hump type speed breake
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (80% length of the Road is considered),Painting of speed breaker
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801,800mm x 600mm rectangular
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (Provided only on WBM surface)
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. Statement-3
20mm thick open graded Premix carpet using bituminous (penetration grade/ modified bitumen) Binder Providing , laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2 mm to 5.6mm aggregate eithe rusing penetration grade bitumen or emulsion to required line, grade and level to surfe as wearing course on a previously prepared base, including mixing in a suitable plan, laying and rolling with a three wheeler 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical specification clause:508 Case 1 By Manual Means (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Case I , Type A as per Technical Specification Clause:510 (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (80% length of the Road is considered),Painting of speed breaker
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801,800mm x 600mm rectangular
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (Provided only on WBM surface)
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. Statement-3
20mm thick open graded Premix carpet using bituminous (penetration grade/ modified bitumen) Binder Providing , laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2 mm to 5.6mm aggregate eithe rusing penetration grade bitumen or emulsion to required line, grade and level to surfe as wearing course on a previously prepared base, including mixing in a suitable plan, laying and rolling with a three wheeler 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical specification clause:508 Case 1 By Manual Means (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Case I , Type A as per Technical Specification Clause:510 (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (80% length of the Road is considered),Painting of speed breaker
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801,800mm x 600mm rectangular
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (Provided only on WBM surface)
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
20mm thick open graded Premix carpet using bituminous (penetration grade/ modified bitumen) Binder Providing , laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2 mm to 5.6mm aggregate eithe rusing penetration grade bitumen or emulsion to required line, grade and level to surfe as wearing course on a previously prepared base, including mixing in a suitable plan, laying and rolling with a three wheeler 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical specification clause:508 Case 1 By Manual Means (i) Bitumen (S-90),Providing Hump type speed breake
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Case I , Type A as per Technical Specification Clause:510 (i) Bitumen (S-90),Providing Hump type speed breake
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (80% length of the Road is considered),Painting of speed breaker
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801,800mm x 600mm rectangular
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (Provided only on WBM surface)
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. Statement-3
20mm thick open graded Premix carpet using bituminous (penetration grade/ modified bitumen) Binder Providing , laying and rolling of open graded premix carpet of 20mm thickness composed of 13.2 mm to 5.6mm aggregate eithe rusing penetration grade bitumen or emulsion to required line, grade and level to surfe as wearing course on a previously prepared base, including mixing in a suitable plan, laying and rolling with a three wheeler 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical specification clause:508 Case 1 By Manual Means (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Case I , Type A as per Technical Specification Clause:510 (i) Bitumen (S-90),Providing Hump type speed breaker
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (80% length of the Road is considered )Painting of speed breaker
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork insubstructure as per technical specification
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801,800mm x 600mm rectangular
MR SHOBHAN KUMAR SAHA
ETI SAHA
Nozrul Islam
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .