Loading…
Loading…
Tender Value
₹2.1 Cr
EMD Value
₹4.2 L
Closing Date
10 Jun 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less ;where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b)(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender.
Supply, Installation, Testing and commissioning of Split and/or Window Room Air Conditioner of at least one work of 1/3rd tonnage with or without maintenance contract of the total tendered Air Conditioning tonnage
35 conditions · 7 needing a document upload
Valid copy of PAN and GSTIN needs to be furnished along with the documents.
Tenderer should fill up the Tender Form (First Sheet) as per 'Annexure-I' of GCC. Incomplete or partial fill up the Tender Form (First Sheet) by the Tenderer will be liable to reject.
For Sole Proprietorship firm a)Affidavit as per 'Annexure'. b)Special power of Attorney as per proforma given in 'Annexure' to be submitted by sole proprietor firm duly notarized.(Not required if tender documents are submitted by proprietor himself)
For Partnership firm a)Self/Notary attested copies of Partnership deed. b)Special Power of Attorney as per proforma given in 'Annexure' to be submitted by Partnership firm. (Not required if one or more partners are authorized in Parternership deed to sign on behalf of the firm.)
For Limited Company a) Copy of Memorandum & Articles of Association of Company. b)Self /Notary attested copy of resolution passed by Board of Directors authorizing its Director/Employee to deal with tender on behalf of company. c) Attested copy of Notarized Special Power of Attorney including ratification clause duly signed by person authorized by the company.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The total cost is including GST. Hence tenderer are advised to quote the tender inclusive of GST.
All the dismantled material should be handed over to E.I.C. at site with proper challan
All the materials should be got inspected and approved by the competent authority Sr.DEE/G/RNY or his representative & Engineer in Charge at site should be contacted before execution of work.
The contractor(s) have to supply all petty stores, which may be required for successful commissioning of the equipments, but not mentioned in the schedule of works. The rate quoted against each item shall be inclusive of those petty stores.
The Contractor shall execute the work to entire satisfaction of the site Engineer, SR DEE/RNY(G) or his representative.
All materials which will be utilized for this work shall confirm to relevant IS specifications.
Successful Tenderer shall produce & hand over test and Guarantee certificate issued by manufacturer of all the equipment/ Component at the time of supply to Railways, failing which bill of the work will not be passed.
Wiring wire/Cable Make should be of Polycab/Goldmedal/Richa/Havell's/Kolors/Benlo/Anchor/BCH/Vinay Electricals.
Switch, socket, power unit, ceiling rose, holder, concealed box, AC starter etc make should be of Kolor/Anchor/Goldmedal/Richa/Havell's/C&S/Benlo/Anchor/Vinay Electricals.
GI pipe make should be of Jindal/Bansal/TATA/Nezone.
MCB, RCCB, DB Make should be of BCH/C&S/ABB/Geco/Legrand/Havell's/Richa/Benlo/Goldmedal/Vinay Electricals.
PVC pipe should be of Richa/Presto Plast/J Plast.
Room Air Conditioner should be of Voltas/LG/Havell's/Samsung/ Blue Star.
XLPE armoured aluminium cable make should be of Havell's/KEI/Polycab/Richa.
Insurance policy has to be taken against contract by contractor, indemnifying the Railways of any financial implication arising due to payout of claims on account of damages, accidents, untoward incidents etc. during the execution of work.
Tenderer should submit the documents as per the Annexure-'A' attached at the time of submission of bill.
Successful contractor must follow guidelines as per extant rules of IR-Shramik Kalyan Portal.
Penalty :- In case of any damage causes to railway materials at the time execution of work, penalty will be imposed as per railway norms otherwise the same should be rectified as per original.
Agency should give their email id and mobile no. on which instruction for daily work will be issued for different site. 12 hours will be given after mail/message for arranging labour and site supervisor
No work can be carried out without availability of site supervisor. if site supervisor is not available, then work will be stopped, and action will be taken as per GCC.
Provision of Room Air Conditioner in Offices at Stations over Rangiya Division as a part of Passenger Amenities.
RNY-EL-T-01-2026-27
RNY-EL-T-01-2026-27
Open
Works - General
90 Days
Kamrup, Assam
₹0
₹4.2 L
10 Jun 2026
13 May 2026
27 May 2026
41 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,08,45,861.1 | ||
| — | 285.00 | — | — | ||
| Supply and Wiring of concealed AC point by PVC insulated and un-sheathed FRLS multi stranded copper cable, single core 4.0 sq.mm through PVC heavy gauge pipe with earth continuity by 1.0 sq.mm multistrand copper cable including unbreakable concealed box. Cable connection to be done through modular controlling switch, socket, 25A power unit, 6/16 A Top, installed in concealed unbreakable modular box (4 way x2), cover plate etc. with all accessories including massonary works as per direction of EIC at site. | — | — | — | 1,92,278.1 | |
| — | 285.00 | — | — | ||
| Supply and fixing of 25A, 240V, 50Hz 2 module single phase motor starter as per direction of EIC at site. | — | — | — | 2,45,499 | |
| — | 25.00 | — | — | ||
| Supply and handing over of 25A, 240V, 50Hz 2 module single phase motor starter to EIC at site. | — | — | — | 21,535 | |
| — | 285.00 | — | — | ||
| Supply and fixing of 6/16 A, 240V, 50Hz 2 module Universal Socket (with Safety Shutter) as per direction of EIC at site. | — | — | — | 80,712 | |
| — | 25.00 | — | — | ||
| Supply and handing over of 6/16 A, 240V, 50Hz 2 module Universal Socket to EIC at site. | — | — | — | 7,080 | |
| — | 285.00 | — | — | ||
| Supply and fixing of 6/16 A, 240V, 50Hz Kin 16A 3 Pin Plug Top with Indicator (with Special Pin) as per direction of EIC at site. | — | — | — | 60,534 | |
| — | 25.00 | — | — | ||
| "Supply and handing over of 6/16 A, 240V, 50Hz Kin 16A 3 Pin Plug Top with Indicator (with Special Pin) to EIC at site." | — | — | — | 5,310 | |
| — | 9500.00 | — | — | ||
| Supply & concealed wiring of earth continuity for Main line/ Submain line by 1.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable PVC heavy gauge pipe as required through the circuit as per direction of EIC at site. | — | — | — | 1,71,000 | |
| — | 12000.00 | — | — | ||
| Supply & concealed wiring of Submain/Main line by 4.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site. | — | — | — | 5,04,000 | |
| — | 9000.00 | — | — | ||
| Supply & concealed wiring of Submain/Main line by 6.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site. | — | — | — | 5,67,000 | |
| — | 5000.00 | — | — | ||
| Supply & concealed wiring of Main line by 10.0 sq mm PVC insulated & unsheathed, single core, multi stranded FRLS copper conductor cable through suitable size PVC heavy gauge pipe as required as per direction of EIC at site. | — | — | — | 5,30,000 | |
| — | 6500.00 | — | — | ||
| Supply & fixing of PVC heavy gauge pipe 25mm by concealing of wall for drawing of Main/Submain line as required as per direction of EIC at site. | — | — | — | 6,04,500 | |
| — | 150.00 | — | — | ||
| Supply, installation, testing & commissioning of SPN distribution board 8 way double door metal SPN DB consisting 40A, MCB DP - 1 no, 20A, MCB DP - 2 nos, 20A, MCB SP - 2 nos with enclosure and necessary fixing arrangements as per direction of EIC at site. | — | — | — | 7,67,829 | |
| — | 138.00 | — | — | ||
| Supply and erection of Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. etc as per direction of Engineer - in - charge at site. Drg ref no PCEE/ELG/DRG/2024/1 Dated 30.09.2024. | — | — | — | 8,22,204 | |
| — | 195.00 | — | — | ||
| Supplying , Installation, Testing and Commissioning of 2.0 ton Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). (Make - Voltas/LG/Havell's/Samsung). | — | — | — | 1,11,92,220 | |
| — | 90.00 | — | — | ||
| "Supplying , Installation, Testing and Commissioning of 1.5 ton Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). (Make - Voltas/LG/Havell's/Samsung)." | — | — | — | 39,18,510 | |
| — | 285.00 | — | — | ||
| Supply and fixing wall mounted MS stand with painted for fixing of outdoor unit of RAC with all accessories as per direction of EIC at site. | — | — | — | 2,13,750 | |
| — | 500.00 | — | — | ||
| Supply & laying of 1/2",1/4" & 5/8" copper pipe line for refrigerant with kinifoam insulation (indivisual & overall) from indoor to outdoor & outdoor to indoor unit as per direction of EIC at site. | — | — | — | 2,52,000 | |
| — | 1000.00 | — | — | ||
| Supply, testing & connections of 1100 V Grade, 25 sq mm 4 core, XLPE insulated and PVC sheathed Aluminium multistrand round armoured aluminium cable as per IS 7098 (Part 1) 1988 with upto Date Amendments as per direction of EIC at site. | — | — | — | 4,36,900 | |
| — | 1000.00 | — | — | ||
| Laying of 25 sq mm one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering as per direction of EIC at site. | — | — | — | 2,53,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-012026-27.pdf
ATTACHMENT
AnnexureNEW.pdf
ATTACHMENT
GCCUpdateduptoACS-7.pdf
ATTACHMENT
ACS-8.pdf
ATTACHMENT
ACS-09.pdf
ATTACHMENT
ACS-10.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
JPO8.5.24-CablediggingworksNFR.pdf
ATTACHMENT
TechCircularwithDrgforEarthingandCableLayingUG.pdf Earthing Drawing
ATTACHMENT
TechCircularwithDrgforEarthingandCableLayingUG.pdf
ATTACHMENT
Corrigendum1.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .