Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC FLAT NO 441 G F LIG FLATS PH 2 SECTOR 14 PKT 03 DWARKA NEW DELHI 110078 | NEW DELHI | NEW DELHI | DELHI | 110078 | ₹20.9 L | L1 | Accepted-AOC BEING L1 AND REASONABLE |
| 2 | L2₹23.6 L+₹2.7 L (13.0%)Rejected-AOC | ₹23.6 L+₹2.7 L (13.0%) | L2 | Rejected-AOC NOT BEING L1 |
| 3 | L3₹23.8 L+₹2.9 L (14.1%)Rejected-AOC H NO 28 FIRST FLOOR E BLOCK KARMPURA WEST DELHI 110015 | WEST DELHI | DELHI | 110015 | ₹23.8 L+₹2.9 L (14.1%) | L3 | Rejected-AOC NOT BEING L1 |
| 4 | L4₹24.1 L+₹3.2 L (15.3%)Rejected-AOC | ₹24.1 L+₹3.2 L (15.3%) | L4 | Rejected-AOC NOT BEING L1 |
| 5 | L5₹24.4 L+₹3.5 L (16.7%)Rejected-AOC | ₹24.4 L+₹3.5 L (16.7%) | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Feb 2024, 6:00 pmClosed
GE EM RR HOSPITAL, DELHI CANTT-10
GE EM RR HOSPITAL, DELHI CANTT-10
COMPREHENSIVE MAINTENANCE OF OT LIGHT, NURSE CALL SYSTEM, UPS AT AHRR ADC UNDER GE EM RR HOSPITAL, DELHI CANTT-10
2024_MES_638849_1
GE/H-44/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
DELHI CANTT 10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹60,000
Yes
30 Mar 2024
24 Jan 2024
24 Feb 2024
24 Jan 2024
22 Feb 2024
8 Feb 2024
Amount
Comprehensive preventive and periodical maintenance and checking serviceability of on line UPS installed in various switch rooms/Wards/Dept of CTVS Centre and Army Dental Centre as per manufacturer's recommendation in reliable safe and efficient manner using latest technique & expert consultancy by regularly examining and adjusting the mechanical & electrical driving equipment including replacement of defective /spare parts/items as and when required by employing 01 technician having qualification of ITI or diploma in electrical/ electronics engineering with adequate experience in the general shift from 0900 hrs to 1700 hrs including Sunday and holiday complete all as specified to entire satisfction of Engineer-in-charge. (i) 20 KVA UPS -05 Nos (ii) 30 KVA UPS - 12 Nos Notes : (i) The cost of all defective /userviceable spare parts/items required to be replaced is deemed to be included in the rate quoted by contractor (ii) Cost of any item and extra manpower required to make the system functional is deemed to be included in the rate quoted by the contracor. (iii) The contractor shall attend the complaints of UPS on receipt at any time round the clock including Sunday and Holiday and the cost of the same is deemed to be included in the rates quoted. The penalty for non attending the complaints of UPS upto six hrs shall be Rs. Rs.1000/- per day. (iv) Maint/ repair as enumerated above shall be under taken by the manufacturer or their authorized dealer/ rep. (v) The dust cleaning shall be carried out of each UPS in a week. (vi) The elect connections shall be checked regularly for looseness / tightening the same. (vii) The fortnightly periodical maint shall be carried out in rotation apart from breakdown for each UPS and record of same to be maintained duly signed by contractor rep and MES rep. (viii) The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work. (ix) Rate quoted by contractor for this item does not include replacement of battery and main transformer
Comprehensive Maintenance of Wired/Wireless multi services Nurse Call System installed at AHRR, of following location, employing 01 technician having qualification of ITI in electrical/electronics engineering with adequate experience in the general shift from 0900 hrs to 1700 hrs including Sunday and holiday to make the system functional in following wards :- (i) Main Bldg AHRR- 647 Nos bed unit and 26 Nos display (ii) CTVS Centre - 257 Nos bed unit and 12 Nos display Notes : (i) Preventive & routine repair/maintenance of Wireless Display and controlling units. (ii) Preventive & routine repair/maintenance of Wireless Bed Units (iii) Preventive & routine repair/maintenance of DC 12V batteries for Bed Units (iv) Preventive repair & Maintenance of all systems on monthly basis and upkeep of log book. (v) Attending to all complaints within 24 hours failling which penal recovery @ Rs 500.00 /complaint per day will be effected from contractor's dues (vi) Field Service Reports will be maintained and submitted to the concerned JE(MES) whenever required. (vii) All spares parts included in quoted rates excluding wireless bed unit and wireless display and controlling unit. (viii) The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work.
Comprehensive preventive and periodical maintenance of OT lights (21 Nos) installed at OT Complex of main bldg of AHRR, CTVS Centre and Army Dental Centre as per manufacture recommendation, in reliable, safe and efficient manner using latest techniques & expertise consultancy by 01 technician having qualification of ITI in electrical / electronics in general shift from 0900h to 1700h including sunday and holiday, and adjusting the mechanical and electrical driving equipment incl replacement of minor defective / spares parts / items i.e. lamp including complete accessories likes driver, ballast etc and wire, lugs, nut, bolts, screws etc as and when required, complete all as specified to entire satisfaction of Engr-in-charge. (i) Main Bldg Hospital (P-100) - 09 Nos (ii) CTVS Centre - 07 Nos (iii) Army Dental Centre - 05 Nos Note : (i) The cost of all kind of minor spares parts / items i.e. nut, bolt, washer, fastner etc is deemed to be included in the quoted rates. (ii) The cost of transportation (to and fro), skilled manpoer and other necessary equipment shall be arranged / brought by contractor to complete the job at site only and no extra cost shall be paid to the contractor in this effect. (iii) The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work. (v) The penalty for non attending the complaints upto six hrs shall be Rs. 500/-, per day.
Supply and installation including testing and commissioning of SMF Battery 12 Volts, 42 AH with battery copper terminals / thimples, battery inter-connection copper cable 16 Sqmm etc, complete all as specified. Note:- Minimum Replacement manufacture warranty for 2 years.
Supply and installation including testing and commissioning of SMF Battery 12 Volts, 65 AH with battery copper terminals / thimples, battery inter-connection copper cable 16 Sqmm etc, complete all as specified. Note:- Minimum Replacement manufacture warranty for 2 years.
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified and directed.
Material and labour for Sub main wiring with 4 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit with wall thickness 1.6mm thick and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified. Note : 1. The Four run of 6 Sqmm wire, one run of 6 Sqmm wire (for earth) and 1 mtr PVC conduit pipe will be measured as one unit.
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit with wall thickness 1.6mm thick and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified. Note : 1. The two run of 6 Sqmm wire, one run of 6 Sqmm wire (for earth) and 1 mtr PVC conduit pipe will be measured as one unit.
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit with wall thickness 1.6mm thick and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified. Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire (for earth) and 1 mtr PVC conduit pipe will be measured as one unit. Note for Item No 7 to 9 :- Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as specified.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as specified.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN DB 4 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCBs and isolators etc and making all necessary connections complete all as specified and directed.
S & F in replacement RCBO, 230 Volt, 40 Amp, 30mA, 50 Hz, with 10 kA short circuit capacity of Double pole for ensuring protection from leakage current, short circuit & over load to the user for a particular circuit. In normal use, it is safe to use and free of threat to user as well as to environment in accordance with IS 12640-2 & IEC 61009-1 in the SPN DB as outgoing all as specified.
S & F in replacement RCBO, 415 Volt, 40 Amp, 30mA, 50 Hz, with 10 kA short circuit capacity of 4 pole for ensuring protection from leakage current, short circuit & over load to the user for a particular circuit. In normal use, it is safe to use and free of threat to user as well as to environment in accordance with IS 12640-2 & IEC 61009-1 in the TPN DB as outgoing complete all as specified.
Supply and installation in replacement of a Surge Protective Device (SPD) , 40 Amp with T2/20KA, 2-pole, CT1 protection mode. SPN DB as incomer complete with all necessary connections.(Incomer) complete all as specified.
Supply and installation in replacement of a Surge Protective Device (SPD) , 40 Amp with T2/20KA, 4-pole, CT1 protection mode. TPN DB as incomer complete with all necessary connections.(Incomer) complete all as specified.
S & F in replacement MCB, SP, 40 to 63 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed
S & F in replacement MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed
Supply and fix environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD 4X1 LEDs panel of 36 Watt as light source, suitable for Armstrong/Grid ceiling, complete all as specified.
M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire including connecting testing etc complete all as specified and directed.
iswar enterprises
GE WORLD
LABOTEK
ACR ENTERPRISES
RUCHIKA ENGG.WORKS
yameen enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .