Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹33.0 L+₹25,034 (0.76%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹35.3 L+₹2.6 L (7.84%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹36.6 L+₹3.9 L (11.8%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | Rejected-Technical | - | Rejected-Technical documents mismatch |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
31 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8878/E8
2020_MES_364125_1
GE/ALP (8878) OF KOLKATA 2020-21
Open Tender
Civil Works
Item Rate
334 days
GE ALIPORE KOLKATA
Class D Category a ii
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹66,000
Yes
26 Nov 2020
25 Jul 2020
1 Sept 2020
25 Jul 2020
31 Aug 2020
10 Aug 2020
60 days
Amount
Testing, inspecting with operating of fire fighting pumping installation installed at Main pump house for CH(EC), including testing of riser, hydrant, hose reel working with minor repair of all parts involved for smooth operation/function of plant including greasing, cleaning, adjustment, minor repairs of nuts, bolts, washers etc of centrifugal fire fighting & jockey pump sets etc with other related equipments of the pump house/ installations alongwith valves including cleaning of inside and outside areas of the respective pump houses, maintenance of suction and delivery pipe lines, primary fill up of priming tanks at Main pump house fire fighting installation consist of (i) 60 HP electric driven centrifugal pump set - 01 No complete all as specified and as directed.
All as Item No 1 but location Defi Tech Bldg fire fighting installation consist of (i) 2850 LPM, 70 m head electric driven centrifugal pump set - 02 Nos (ii) 900 LPM, 30 m head electric driven booster pump centrifugal type - 01 Nos (iii) 2850 LPM, 70 m head IC Engine driven centrifugal pump set - 01 No (iv) 2850 LPM, 70 m head jockey pump set - 01 No
All as Item No 1 but location New pump house at II Line ,fire fighting installation consist of (i) 100 HP electric driven centrifugal pump set - 03 Nos (ii) 82.5 BHP IC Engine driven centrifugal pump set - 01 No (iii) 25 HP jockey pump set - 0 No (iv) 20 HP jockey pump set - 01 No
All as Item No 1 but location MAP Phase I pump house fire fighting installation consist of (i) 75 HP electric driven centrifugal pump set - 01 No (ii) 92 BHP IC Engine driven centrifugal pump set - 01 No (iii) 20 HP jockey pump set - 01 No
All as Item No 1 but location MAP PH-II Fire fighting(i) main nhydrant pump 37 KW-01 No (ii) Jockey pump 9.3KW-1 No ,(iii) IC Engine driven centrifugal pump set - 01 No
S&F in repair the following items in repair for maintanance of IC Engine driven pump set :-
Greaves lub oil
Lubrication oil filter and element
Filter element with O ring
Fuel insrt with o ring
Fuel Off sol,12V DC with fine
Coolant additive
Battery cable (2 PC set)
Oil pressure switch
Tempreture switch
Supply, installing, testing of battery charger in repair suitable for 150 AH battery complete all as specified and as directed.
Supply, installing ,testing in repair of 12 V DC lead acid battery 150AH complete all as specified and as directed.Make: EXIDE/ AMCO/ MICROTECH
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation etc or for shaft, wells man holes, fire holes etc. and getting out in soft/loose soil complete all as specified and directed.
Returning,filling in, including spreading,leveling watering and well ramming in layers not exc . 25cm in soil. complete all as specified.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc, 1.5 mtr above the starting point complete all as specified and as directed.
Taking up unserviceable MS Pipe both end flanged 150 mm dia from trencehes/floor/wall including all fittings complete all as specified and as directed.
Taking up unserviceable MS Pipe both end flanged 100 mm dia from trencehes /floor/wall including all fittings complete all as specified and as directed.
Taking up unserviceable MS Pipe both end flanged 80 mm dia from trencehes /floor/wall including all fittings complete all as specified and as directed.
Supply and fixing of MS ERW pipes 150 mm dia IS-1239 heavy grade laid in ground complete with all fittings, bends including necessary connections of pipe complete all as specified and as directed.
Supply and fixing of MS ERW pipes 100 mm dia IS-1239 heavy grade laid in ground complete with all fittings,bends including necessary connections of pipe complete all as specified and as directed.
Supply and fixing of MS ERW pipes 80 mm dia IS-1239 heavy grade laid in ground complete with all fittings,bends including necessary connections of pipe complete all as specified and as directed.
Supply and fixing of MS ERW pipes 25 mm dia IS-1239 heavy grade laid in ground complete with all fittings,bends including necessary connections of pipe complete all as specified and as directed.
Material and Labour for flanged joints of MS pipes 150 mm dia with rubber or fibre board gasket, bolts etc complete all as specified and as directed.
Material and Labour for flanged joints of MS pipes 100 mm dia with rubber or fibre board gasket, bolts etc complete all as specified and as directed.
Material and Labour for flanged joints of MS pipes 80 mm dia with rubber or fibre board gasket, bolts etc complete all as specified and as directed.
Material and Labour for MS clamp of any sizes for fixing 150 mm dia riser line including drilling hole to the wall and fixing nut Bolt,washer,gasket etc. complete all as specified and as directed.
Supply and Fixing MS bend 150 mm dia,flange type with holes,gasket,nut bolts etc complete all as specified and as directed.
Supply and Fixing MS bend 100 mm dia,flange type with holes,gasket,nut bolts etc complete all as specified and as directed.
Supply and Fixing MS bend 80 mm dia,flange type with holes,gasket,nut bolts etc complete all as specified and as directed.
Taking down Centrifugal pump set from existing position for carrying out for repair works at work shop and re-assembling, re-installing the pump set in original position for pump capacity 75 HP complete all as specified and as directed. Note: Spare parts required for renewal shall be measured and paid separately.
All as item No 26 but for fire fighting pump capacity 20HP.
Dismantling and opening the motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding by carrying the motor to outside the cantonment area, re-assembling and refixing the same with pump in original position for the following capacity of motor :-
(a) 75 HP 3 Phase .
(b) 20 HP 3 phase .
Supply and fixing of following spare parts for pump set including motor complete for 20 HP centrifugal pump:-
(a) Impeller CI
(b) Pump shaft
(c) Neck ring
(d) Shaft Sleeve
(e) Bearings No 6305/6306/6309 as per site Make : SKF or equivalent
Supply and fixing of following spare parts for pump set including motor complete for 75 HP centrifugal pump:-
(a) Impeller CI
(b) Pump shaft
(c) Neck ring
(d) Shaft Sleeve
(e) Bearings No 6305/6306/6309 as per site Make : SKF or equivalent
Supply and Fixing in repair Gun-metal, globe or gate valves, 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and Fixing in repair stainless steel 63 mm fire hydrant valve conforming to IS-908 single headed with double locked adapter with iron wheel including gasket,nut & bolts etc. for fixing in high rise building complete all as specified and as directed.
Supply and Fixing in repair stainless steel 63 mm fire hydrant valve double headed conforming to IS-908 with double locked adapter with iron wheel including gasket,nut&bolts etc. for fixing in stand post at the bottom of above buildings complete all as specified and as directed.
Supply and Fixing in repair MS blank flange having suitable Nos of holes and including all necessary jointing materials complete all as specified and as directed.
Supply and Fixing Rubber hose reel of 20 mm dia and 30 m long with MS make hose reel drum set with necessary accessories conforming to IS:884, like connector, adaptor and ss shut off nozzle complete all as specified and as directed.
Supply and Fixing branch pipe and stainless steel nozzle for 20 mm dia hose real conforming to IS 903 complete all as specified and as directed.
Supply and Fixing in repair cast iron sluice valve flange type conforming to IS-14846 of class PN 1.6 complete of size 150 mm dia complete all as specified and as directed.
Supply and Fixing in repair cast iron sluice valve flange type conforming to IS-14846 of class PN 1.6 complete of size 80 mm dia complete all as specified and as directed.
Supply and Fixing in repair cast iron sluice valve flange type conforming to IS-14846 of class PN 1.6 complete of size 25 mm dia complete all as specified and as directed.
Material and labour for painting hose box, MS pipes with two coats of synthetic enamel paint red in colour over a coat of red oxide primer after removing/scrubbing old painted / rusted surface complete all as specified and as directed.
Supply and Fixing Branch pipe gun metal 63 mm and nozzle confirming to IS 903 incl with all jointing materials complete all as specified and as directed.
Supply and Fixing in repair 63 mm dia and 15 m long RRL canvas hose conforming to IS 636 complete including male& female coupling complete all as specified and as directed.
Material & Labour for CI fitting such as Tee, bend, taper, Tail pieces and type upto 150mm bore pipe complete all as specified and as directed.
Supply and Fixing in repair Foot Valve CI conforming to IS 4038,complete of size 150 mm dia complete all as specified and as directed.
Supply and Fixing in repair Foot Valve CI conforming to IS 4038,complete of size 80 mm dia complete all as specified and as directed.
Supply and fix double flanged single door type swing check reflux (Non return) with by pass arrangement valve in repair confonning to IS-5312 of size 150 mm including supply and fixing suitable size of nut bolts washer and gasket etc.complete all as specified and as directed.
Supply and fix double flanged single door type swing check reflux (Non return) with by pass arrangement valve in repair confonning to IS-5312 of size 100 mm including supply and fixing suitable size of nut bolts washer and gasket etc.complete all as specified and as directed.
Supply and fix double flanged single door type swing check reflux (Non return) with by pass arrangement valve in repair confonning to IS-5312 of size 80 mm including supply and fixing suitable size of nut bolts washer and gasket etc.complete all as specified and as directed.
Supply and Fixing for fire fighting hose box made of 18 gauge MS sheet 800 mm x 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 mm gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and as directed.
Supply and fixing the following Items for Fire Fighting Alarm System complete all as specified and as directed.
(i) S&F in repair for sounder and flasher EN-54 suitable for addressable fire panel all as specified and directed by Engr-in- Charge Make- Hochiki/Honeywell/Agni/Appolo
(ii) Supply and fixing in repair multi detectors with acc-en intelligent multi sensor Complying with and type certified to EN - 54 all as specified and directed by E-in-Charge Make Hochiki/Honeywell/Agni/Appolo
(iii) S&F in repair of manual call point suitable for existing addressable fire alarm panel with chain hammer, MS housing, powder coated chain hammer to break glass complete all as specified and as directed.Make:- Hochiki/Honeywell/Agni/Appolo
(iv) Supply ,commissioning, installing ,testing in repair of network card for latitude panel-addressable for connecting the existing repeater panel suitable for existing panel all as specified and directed by Engr-in- Charge Make:- Hochiki/Honeywell/Agni/Appolo
(v) Supply,Installation Testing Commissioning of Networkable Analogue Addressable Fire Alam Control Panel. The Panel Shall be compliant with EN54-4 and approved by LPCB. The Fire Alarm control Panel should have 4 loops & shall have expandable capacity to 8/ loops. The panel must have full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The panel must also have the capability to take addressable intelligent wire and wireless devices on same loop. Each loop shall have a capacity of 127 analogue addressable devices and 127 base sounders/Base sounder beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The panel shall have three access levels. Panel Shall support filterable and printable. The panel shall have three access levels, Panel shall support upto 500 cause & Effects entries, with upto 20,000 inputs controlling & 20,000 controlling outputs across the network. The panel shall have capability for peer to peer networking through Rs 485 network card. The panel must have 4 inbult programmable sounder circuits, each circuits rated at 2.5A . The panel must have inbult 3 programmable inputs and 5 inbult programmable relay outputs. The panel shall have up to sub-addressable 512 programmable inputs/outputs via optional Rs 485 COMMS serially connected expansion cards. The panel shall have 240V AC power supply alongwith automatic Battery Charger. The panel shall be fully expandable via common plug in loop driver boards, The user shall have a choice of using the panel with 5.25 Amp o 10.25 Amp power supply unit which is inbult in the FACP and should be approved to EN54-4. The panel shall have configurable via USB port to PC or memory stick. The panel shall have dedicated Rs 232 serial port for optional printer. Approved by EN54.Make Hochiki Model No.Latitude 4 Loop EN54 or eqv in Honeywell/Agni/Appolo
Material and labour for fire fighting point wiring with copper conductor from Ground floor to Top Floor for MCP/Hooter/Control Pannel Board(Control panel Board to Each MCP located at Each floor and hooter) including appropriate size of PVC casing capping with all accessoriese such as tees, bends, elbows, reducers, bell mouth tube ends, couplers, lock nuts, saddles, pipe hooks etc. for surface/concealed wiring as per existing with and including 2 run of 1.5 sqmm PVC insulated FRLS garde copper cable of 1100 volt main wire and one RM of 1.5 sqmm PVC insulated FRLS grade copper cable 1100 Volts grade for earh wire complete all as specified and as directed. Note -3 RM of copper cable shall be constituted as unit rate.
Supply & fixing sheet glass ordinary quality with 4 mm thickness for fire cabinet box complete all as specified and as directed.
Supply and fixing as in repair CI screwed end single Air valve 25mm nominal size as per IS:14845, (Refer to IS-210, 318 (HP office)), all with basic materials, PN-1.6, complete all as specified and as directed.
Supply and fixing in repair Sprinkler glass bulb type (Standard response) as per S:15106/TAC guidelines 68 degree temperature rating pendent type complete all as specified and directed.
S&F Rotational moulded polyethylene multilayered water storage tanks 2000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position and tapping both tank by 80mm pipe complete all as specified and directed.
M&L for Construction of measonary valve pit chamber with burnt brick (Sub class "B") in cement mortor (1:6) and 10 mm thick plastering in CM 1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally on 1000 mm x 1000 mm x 1000 mm with 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces including earth work complete all as specified and as directed.
ELECTRO FREEZE
KWALITY CONSTRUCTION
JAIN CONSTRUCTION AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .