Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC JAISALMER | JAISALMER | RAJASTHAN | 342310 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.7 L+₹1.4 L (3.43%)Rejected-Finance 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹46.1 L+₹5.8 L (14.5%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹47.9 L+₹7.6 L (18.8%)Rejected-Finance 5 L LEHAL COLONY PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹48.2 L+₹7.9 L (19.7%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
28 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPL REPAIRS TO 06 X SWTS (P-176, P-177, P-199, P-1011, P-1092 AND P-1096), SEPTIC TANK AT P-111 AND OTHER MINOR WORKS IN CERTAIN UNIT AT GE (A) JAISALMER
2023_MES_578528_1
8251/22-23/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹99,000
Yes
16 Mar 2023
1 Feb 2023
2 Mar 2023
1 Feb 2023
28 Feb 2023
15 Feb 2023
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in hard rock complete all as specified & directed by Engineer-in-Charge. Note (i) Hard rock obtained from excavation shall be stacked properly. Stacked hard rock shall be measured by deducting 50% quantity for voids for hard rock, remaining quantity will be considered of soft/disintegrated rock. (ii) Hard rock obtained shall be issued under Schedule of credit, which shall not be allowed for uses in work.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified & directed by Engineer-in-Charge.
M&L for plain cement concrete (1:2:4) type B-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified & directed by Engineer-in-Charge.
M&L for precast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in block masonry with solid blocks exceeding 10cm width and setting in cement mortar 1:6 and making kerb wall of 1500 mm height complete all as specified & directed by Engineer-in-charge.
M&L for rendering 10 mm thick plaster in cement mortar (1:6) on PCC block masonry fair faces of concrete surfaces of walls and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-charge.
M&L two coats of white wash on platform surface complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) medium grade galvanised, 15mm bore with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing 25 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete for hot/cold water pipe line complete all as specified and directed by Engineer-in-charge.
S&F fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F bib taps cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F stop valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15 mm bore iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F gun metal globe or gate valve, with iron wheel head, screwed both ends for 25 mm bore iron pipe all as specified & directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position including taking down old existing PVC tank complete all as specified and directed by Engineer-in-charge.
M&L for providing fibre reinforced micro concrete at the rate of 25kg per 0.0125 m3 with 20% properly graded 5mm to 10mm silt free aggregate as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine including demoliton of existing flooring, all as specified and directed. Make: Fosroc/STP/BASF/CICO or equivalent as specified in CA.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 including water proofing compound and finished even & smooth without using extra cement with taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as spd and directed. Note : (i) WPC to be paid separately under item Ser No 13 as supply only. (ii) The cost of scaffolding or any other type of wooden/iron fabricaction required to execute the work is included in the cost of item itself. No extra shall be paid for the same.
Supply of liquid integral waterproofing compound @ 100ml/per 50kg cement used. Make : - (IWC) CICO-SUPER or equivalent in Fosroc/Dr Fixit/ACC/ L&T/STP. Note : WPC to be used in rendering by mixing under item Ser No 02 above.
M&L for providing aliphatic acrylate based anti carbonation protective coating system for concrete/ masonry surfaces comprising of the following : - (a) Preparation of surfaces including dusting to receive new treatment. (b) Applying one coat of Silane/Silaxone blend primer @ 0.125 ltr/Sqm or covering 8.0 Sqm/Ltr using portable spray equipment of the knapsack type. (c) Applying polymer under coat over completely dired primer surface using brush or roller to achieve a uniform coating with wet film thickness of not less than 250 microns (coverage not more than 2.5 Sqm/ltr). (d) Applying aliphatic acrylate pigmented top coat (Shade as approved by GE) to a uniform wet film thickness of not less than 125 microns (coverage not more than 8.00 Sqm/ltr). Make :- CICO GUARD-WS / Deckguard S300 Chemical / Chemo System or equivalent in FOSROC/STP/SIKA . (Primer, Coat & Top Coat shall be of same brand.
Note :- (I) Rate of item are inclusive of material, labour, tools and tackle, scaffolding etc complete. (Ii) The structural rehabilitation treatment shall be applied by the company’s authorized applicator only. (ii) Contractor have to get prior approval of applicator or authorized agency by submitting its authorization letter to this office for approval prior to commencement of work. (iii) Submission of 10 year warranty certificate for waterproofing treatment work over roof is mandatory after completion of work. (iv) The cost of Scaffolding work required at certain places is including in the respective items catered for repairs itself. No extra shall be paid for the same.
Demolition of brickwork or stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m all as specified & directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for precast cement concrete (1:2:4) type B-0 using 12.50mm graded stone aggregate in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc and setting in CM (1:4) complete all as directed by Engineer-in-charge.
M&L rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
S&F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde E-250 quality-A) complete all as specified & directed by Engineer-in-charge.
M&L Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25 to 35cm wide, hoisted and set, jointed and grouted in cement mortar (1:3) complete all as specified & directed by Engineer-in-charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar complete all as specified & directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L for PCC (1:2:4) B-0 using 12.5 mm graded stone aggregate as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope complete all as specified & directed by Engineer-in-Charge. (Note :- Supply only water proofing compound shall be measured & paid separately).
Supply only liquid water proofing compound in sealed pack (ISI Marked) complete all as specified & directed by Engineer-in-charge.
M&L for cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in surface channels and drains etc like including necessary forms/ moulds complete all as specified & directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified & directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe complete all as specified & directed by Engineer-in-charge.
M&L for 150mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified & directed by Engineer-in-charge.
Excavating in post holes (or similar holes) in any type of soil, each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 Mtr and making good surface complete all as specified & directed by Engineer-in-charge.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed by Engineer-in-charge. Note :-Fixing only chain link fencing, steel round bars for protection will measured and paid separately.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete as specified & directed by Engineer-in-charge. Note :-Supply only chain link fencing will measured and paid separately.
S&F mild steel Round bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe-410-W Gde E-250 quality-A or Fe 290 (Gd eE-165) complete all as specified & directed by Engineer-in-charge.
S&F hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars for doors, balusters, nosing to steps including embending in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riverting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed by Engineer-in-charge.
S&F mild steel flat iron for securing of chain link fencing conforming to Fe-290 Gde E-165 in post and struts in fencing including fabrication i.e cutting tops drilling holes, notching for wire, welding etc complete all as specified & directed by Engineer-in-charge.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, or square nut. exc 30cm long long and diameter of neck n. exc 12mm complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, not exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide primer complete all as specified & directed by Engineer-in-charge.
Cleaning of septic tank, man holes and inspection chamber etc. by means of removing the silt, sludge, excreta etc. or other materials, manually or mechanically and depositing the same, where directed at a distance not exceeding 150m including excavation of pits of required size to accommodate the foul materials taken out from septic tank, manholes, soakage pits and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge. Note for item No. 1.00 :- (i) Depth of silt, sludge, excreta, etc shall only be measured and paid. (ii) Dewatering/pumping out of foul water shall be measured and paid separately.
Pumping out foul water from soakage wells/septic tank mechanically and removing sludge of capacity 100 users complete all as directed by Engineer-in-charge.
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper cable of size 4.0 Sqmm 1100 Volts grade drawing into and incl PVC cassing capping with all accessories and one single core PVC insulated unsheathed multi stranded copper cable of size 4.0 sqmm, 1100 Volts grade as earth continuity conductor connected to common earth dolly termination directed for sheet metal enclosure box complete all as specified & directed by Engineer-in-charge.
S & F sheet metal enclosure Geyser / AC Box having 20 Amp MCB SP as incomer complete all as specified & directed by Engineer-in-charge.
Supply & fixing of water heater storage type (Geyser) vertical type, with steel inner container of capacity 25 Ltr, power Consumption 2 KW, BEE 5 star rated pressure rating >8 Bar, Powder coated metal body with PUF insulation electrically operated 230 Volt complete all as specified & directed by Engineer-in-charge. Make: Havells Cat pot No : Monza DX GHWAMGSIN025 or equivalent Appx 'C' list of makes.
Supply & fix water heater storage type (Geyser) vertical type, inner container of capacity 50 ltrs, power Consumption 2.0 KW, BEE 5 star rated pressure rating >8 Bar electrically operated, AC 230 Volts, including as per site required Nos of fashner nuts required suitable size fixed in brick wall complete all as specified and directed. BEE 5 Star rated. Make: Havells Cat pot No : Monza DX GHWAMGSWH050 or equivalent Appx 'C' list of makes.
M & L for PVC connection pipe chromium plated 15 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 450 mm suitable for Hot/ cold water system complete all as specified & directed by Engineer-in-charge.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in casing caping including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-charge. (Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length)
S&F double door MCB distribution board SPN, 240 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified & directed by Engineer-in-charge.
S&F double door MCB distribution board SPN, 240 volts, 2 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 20 Amps to 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 40 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Taking down of old unsv tube light fitting of any description light fitting any type any watt complete all as specified & directed by Engineer-in-charge.
Refixing of LED tube light 20 watt ,220 V connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed by Engineer-in-charge.
S& F for I-Senser Smart LED linear Batten 20 W intelligent auto dimmable LED Batten with inbuilt smart sensor aluminium extruted housing ,duly powder coated with opaque polycorbonate diffuser for glare free light output. LED having intergral occupancy/Movement sensor opreating voltage 240 V, 50 Hz AC Supply and Opreating tempreature 0 to 50 C, power factor >_0.95, lumen output >_100, necessary mounting arrangements on PVC square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified & directed by Engineer-in-charge. Make : Shakti cat Ref No : SZSLAMX020-ISS or equivalent Appx 'C' list of makes.
M&L UPVC piping network and connected accessories of various size for 500 LPH RO Plant of required length including bends, tees, unions, end caps, stop cock (straight/ two way), flanges etc complete piping network and to make it complete all as specified and directed by Engineer-in-charge having following Items. Note:- Contractor should visit the site for assesment of piping work and will quote the item and get the work done from professional RO Manufacturer. Make of pipe and accessories: Astral, Ashirvad or equivalent.
ITEM NO. 1.00 CONTD... (a) One no. Raw Water pump of 1 HP with operating pressure 2.5 - 3.5 Kg/cm2 for boosting raw water upto sand filter complete all as specified and directed by Engineer-in-charge.Make: CRI/LUBI/Havells (b) One no. Pressure sand filter(FRP) of size 13" DiaX 54" Height for working pressure 2.5-3Kg/cm2 complete with sand and gravels media for removing > 50 Micron dusts & other suspended particles complete all as specified and directed by Engineer-in-charge.Make: STER LIGHT/PENTAIR. (c) One no. Activated Carban filter(FRP) of size 13" DiaX 54" Height for working pressure 2.5/cm2 complete with activated carbon complete all as specified and directed by Engineer-in-charge.Make: STER LIGHT/PENTAIR.
ITEM NO. 1.00 CONTD... (d) One no. Micron Cartidge filter FRP type having thraded filter20"X4" string wound for removing > 5 Micron suspended particles complete all as specified and directed by Engineer-in-charge. (e ) One no. Antiscalent dosing pump with dosing rate 6 LPH electronic type for antiscalent liquid and with dosing tank of capacity 100 Ltr HDPV complete for scaling resistance for membrane and increase membrane life complete all as specified and directed by Engineer-in-charge. (f) One no. Inline low pressure switch 0-5 Kg/cm2 complete all as specified and directed by Engineer-in-charge.Make: Danfoss (g) One no. High Pressure pump of 1.5 HP having operating pressure 9-11Kg/cm2 centrifugal type/multistage vertical type complete all as specified and directed by Engineer-in-charge. (h) One no. Inline high pressure switch 0-5 Kg/cm2 complete all as specified and directed by Engineer-in-charge.Make: Danfoss
ITEM NO. 1.00 CONTD... (j) Two nos RO Module with FRP type RO pressure tube housing with 4 Nos RO Membrane of size 4" each complete all as specified and directed by Engineer-in-charge.Make of Membrane: DOW/GE/HYDRONOTICS (k) One no. Elecronic panel with complete starter and control panel for operation of RO Plant complete all as specified and directed by Engineer-in-charge. (l) Two nos Flow meter acrylic type online type for RO plant complete all as specified and directed by Engineer-in-charge. (m) Six nos Pressure guage for low pressure from 0-150 PSI and for high pressure from 0-600 PSI burden tube type with bottom and back entry having 1/2" BSPT connection complete all as specified and directed by Engineer-in-charge.
Taking up carefully from trenches/walls/pillar CI/DI water mains incl all fittings with spigot and socket ends incl joint/rubber gaskets/lead wool/tyton joint for the following sizes:-
(a) 100 mm bore.
(b) 150 mm bore.
Relaying, realigning the DI/CI pipe line with spigot and socket ends (in any length) on wall/pillars with necessary fitments (tyton joint/rubber gasket,etc) for complete assembly of following sizes complete all as specified & directed by Engineer-in-Charge.
(a) 100 mm bore.
(b) 150 mm bore.
Supply and laying ductile iron pipe with internal cement mortar lining and external zink pipes with class of pipe K-9 of following sizes:-
(a) 100 mm bore.
(b) 150 mm bore.
Taking down old u/s Sluice valve of any size complete all as specified and directed by Engineer-in-charge.
Supply and fix Sluice valve PN-1.6 with gun metal spindle and wedge nut ISI maked (IS-14846:2000) complete with iron wheel of following sizes:- Note:- Rate includes neccesary arrangements and cutting the pipe of required dimension with attachments for fitting the sluice valve.
(a) 100 mm bore.
(b) 150 mm bore.
Supplying, fixing and testing of CI/DI pipe fitting for spigot socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing/ decreasing or double socket etc). Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs, for pipe upto 50mm bore all as specified & directed by Engineer-in-charge. Note:- Rate of cutting existing pipe for insertion of the fitting is included in the quoted rate.
M&L for PCC (1:3:6) type C-2, using 40 mm graded stone aggregate as in foundation concrete, mass concrete etc complete all as specified & directed by Engineer-in-charge.
Dismantling of valve chamber and removing material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed by Engineer-in-charge.
Construction of valve chamber of size 100 x 100 x 100 cm (internal dimensions) with the following specifications :-
(i) 15cm thick PCC 1:4:8 type D-2 (using stone aggregate) as in foundation concrete. (ii) PCC solid block masonry 200mm thick using grade C-5 block in CM 1:6 (iii) Rendering 15mm thick in CM 1:4 finished even and fair. (iv) PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping. (v) 3mm thick MS sheet cover alongwith MS angle iron frame 40 x 40x6 mm duly embedded in coping concrete with necessary locking arrangement. (vi) Painting MS sheet cover and frame with two coats of synthetic enamel paint over a coat of red oxide primer. (NOTE : Excavation and earthwork included under respective items of Sch 'A')
Cutting the existing PCC/bituminous road of any description to a size not exc. 0.5m wide x 0.5m deep for crossing of pipe including refilling, ramming and making top 100mm thick surface good with plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified and directed.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as specified & directed by Engineer-in-charge. (Note :- Punned thickness of sand cushioning shall only measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
Supply, laying, testing and commissioning of LT XLPE insulated, armoured heavy duty, electric cable, with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 Core including necessary cable glands, lugs etc and including taking down existing unserviceable cable complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB TPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
M&L for MCB TPN 63A, 415V, 10KA rating capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M&L for MCB TP 63A, 415V, 10KA rating capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
MARUDHARA CONSTRUCTION COMPANY
S K TRADER
M/s Shree Construction Company
AMBEY MAA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .