Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.4 L+₹2.3 L (14.5%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹20.1 L+₹4.0 L (25.1%)Rejected-AOC 30 KM GANDHI NAGAR CAMPBELL BAY | CAMPBELL BAY | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | L3 | Rejected-AOC Rejected |
Tender Value
₹14.8 L
EMD Value
₹29,500
Closing Date
4 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) Campbell Bay
GE (I) Campbell Bay, Army land, Campbell Bay, Great Nicobar-744302
PROVN OF ONE 125 KVA GENERATOR FOR ARMY LAND AT CAMPBELL BAY
2023_MES_579081_1
8053/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) Campbell Bay
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹29,500
25 Apr 2023
4 Feb 2023
6 Mar 2023
4 Feb 2023
4 Mar 2023
17 Feb 2023
Amount
Supply, install, testing and commissioning of Silent engine generating set with acoustic enclosure as per CPCB norms 415 volts 125 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition at coastal area and conforming to condition under latest edition of IS 4722, BS 5514/2613/5000 with and including the following:- (i) The capacity of Generator set shall be net after all due de-rating factors as per relevant IS design (ii) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator to the LT Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test (A) Alternator :- Standard design alternator rated at 125 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722 i) Insulation class - 'H‘ ii) Temperature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as acousted by the accepting officer based on design and manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable sizing upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump vi) Air Intake System : Air intake Manifold with Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
(D) Construction Details/specification:- Acoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set batteries and control panel should be inside the enclosure. a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum) vi) The acoustic should be composite in construction and fully assembled integral unit v) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form vi) The DG Set should be provided with external Emergency stop push button vii) The noise level should be 75 dba at 1m under free field conditions. viii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade Make : KOELGREEN of KIRLOSKAR / CUMMINS /PERKINS /CATERPILLAR /CG
Supply, laying and testing cable XLPE Insulated heavy duty electric cables with aluminium conductor 1100 V grade, crossectional area 95 sq mm 3.5 core complete all as specified & directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip of 32x6mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 5 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel 15mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion.
KCM BUILDERS & CONSTRUCTIONS (INDIA) PVT.LTD
M/S RAJBUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .