Loading…
Loading…
Tender Value
₹36.6 L
EMD Value
₹73,111
Closing Date
18 Jul 2026, 3:00 pm2d left
Executive Engineer(E)
Judiciary Electrical Division-I, PWD, Yamuna Western Bank, Lok Nayak Setu, New Delhi-110002
Up-gradation of old conventional type Fire Alarm System into Automatic Addressable intelligent Fire Alarm System in ACI Block at District Court Karkardooma Delhi. (Balance Work)
2026_PWD_293353_2
68/EE(E)/JED-1/PWD/2026-27
Open Tender
Electrical Works
Percentage
30 days
Karkardooma Court Complex
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹73,111
10 Jul 2026
10 Jul 2026
18 Jul 2026
10 Jul 2026
18 Jul 2026
10 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. | |||||
| 1.1 | 6 Zone | 7 | Each | 13,269 | ₹92,883 |
| 2 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. | 21 | Each | 513 | ₹10,773 |
| 3 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. | 21 | Each | 600 | ₹12,600 |
| 4 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. | 7,300 | Meter | 386 | ₹28,17,800 |
| 5 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. | 200 | Each | 1,136 | ₹2,27,200 |
| 6 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. | 400 | Each | 1,223 | ₹4,89,200 |
| 7Repairing, testing & commissioning Main/sector panel of following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities i/c change of IC, internal wiring, Display and Power supply etc complete as required | |||||
| 7.1 | 2 Zone Panel | 4 | Each | 1,568 | ₹6,272 |
| 7.2 | 4 Zone Panel | 4 | Each | 3,155 | ₹12,620 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.87 MB
BOQ_392702.xls
BOQ • 0.34 MB
RecallNIT.pdf
Tender Documents • 1.86 MB
Corrigendum.pdf
PDF • 0.33 MB
Download all tender documents and submit your bid