Tender Value
₹1.3 Cr
Closing Date
17 Feb 2021, 3:00 pmClosed
Manager Electrical
Manager Electrical,ITPO Pragati Maidan New delhi
Supply, Installation, testing and commissioning of cooling towers along with connecting accessories of HVAC Plant for hall No.8-11 and 12,12A at Pragati Maidan New Delhi.
2021_ITPO_612826_1
169-ITPO(1)E-E/20-21/2073
Open Tender
Electrical Works
Item Rate
365 days
ITPO Pragati Maidan New delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,180
Yes
Office of ITPO
Exempted
ITPO Hall No 7 Pragati Maidan NewDelhi
29 Nov 2021
29 Jan 2021
18 Feb 2021
29 Jan 2021
17 Feb 2021
10 Feb 2021
4 Feb 2021
Amount
Supply Installation Testing and Commissioning of Induced draught counter flow FRP Cooling Tower of 562.5 TR for 450 TR Chiller capacity with cooling tower components, FRP casing, FRP basin, base frame (galvanized), Fills, fittings with intact Louvers dynamically balanced Arial flow type fan direct driven TEFC/TEAO induction motor, suitable Inspection Ladder, Electrical cable and tray and connections to the panel including of emergency push button, starter(star-delta),Vibration Isolator, Anti Vibration Mountings etc complete with connection to the old existing system along with dismantling and buy-back of existing cooling tower etc. as required. Cooling towers shall be certified by CTI (Cooling Tower Institute). The new cooling tower must have following specifications:- Heat Rejection Capacity : 562.5TR, Water Flow rate: 1800 USGPM Hot water Temp.: 97.5°F, Cold water Temp. : 90°F,Wet Bulb approach: 7°F, Wet Bulb temperature: 83°F,Evaporation Loss: Not more than 0.7%, Drift Loss: Not more than 0.001%, Total water loss: Not more than 0.7%, Fan Material: Cast Aluminum alloy blades with MSHRD Hub, Motor rating : Appropriate Motor make: ABB/Havells/Hindustan/New India, Motor Type: Squirrel Cage (IP55), TEFC/TEAO, Premium Efficiency(IE3), Fills: High efficiency PVC fills with UV stabilization Tower Structure- Casing: FRP,Basin: FRP, Fill Support: HOT DIPPED GALVANISED FRAME, Bird Screen: HOT DIPPED GALVANISED FRAME Distribution Support: HOT DIPPED GALVANISED FRAME HARDWARE: Stainless Steel,Ladder: MSHDG, Base frame: Galvanized (mini. 632 gsm) Cooling Tower Make: BELL/ MIHIR/PAHARPUR/DELTA
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete with painting in all respect including dismantling and buyback of existing damaged pipe etc. as reqd. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes up to 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia. and above. MAKE: TATA/SAIL/JINDAL
500 mm dia
400 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
80 mm dia
65 mm dia
40 mm dia
Supplying, fixing, testing and commissioning BUTTERFLY VALVE (MANUAL) of following size for condenser water circulation as per specifications. with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified along with fittings, Gasket, Nut-Bolts, Flanges etc. complete as required after dismantling and buyback of existing damaged valve etc. as reqd. MAKE: CASTLE/ADVANCE/AUDCO
300 mm dia
250 mm dia
200 mm dia
80 mm dia (Drain Valve)
40mm dia (Gate valve)
40mm dia (Float valve)
Supply, Installation, Testing & Commissioning of Balancing valves of 300 mm dia., C.I. Body Bonnet SG Iron IS : 1865 GR 420/7 Disc : EN 3 along with fittings, Gasket, Nut-Bolts, Flanges etc. complete as required after dismantling and buyback of existing damaged valve etc. as reqd. MAKE: CASTLE/ADVANCE/AUDCO
Supply, Installation, Testing & Commissioning of Balancing valves of 250 mm dia., C.I. Body Bonnet SG Iron IS : 1865 GR 420/7 Disc : EN 3 along with fittings, Gasket, Nut-Bolts, Flanges etc. complete as required after dismantling and buyback of existing damaged valve etc. as reqd.. MAKE: CASTLE/ADVANCE/AUDCO
Designing, Providing and Construction of RCC vertical column suitable for installation of cooling towers on roof top of halls complete with shuttering, reinforcement, plastering, whitewashing etc. as required including dismantling and disposing off the existing damaged columns as per the direction of engineer in-charge.
AIRWAVES ENGINEERS P. LTD.
Accurate Engineers
CONSENSUS INDUSTRIAL SOLUTION
Hemcool Engineers
Supertech Engineers
snowmex engineers ltd
HV AIRCONDITIONING SYSTEMS PVT. LTD.
WEATHER COOL SALES PVT LTD
Aircon Technique Pvt Ltd
VOLTAS LIMITED
stage.html
html • 0.08 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .