Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | ₹39.5 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹42.5 L+₹3.0 L (7.59%)Rejected-AOC MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹42.5 L+₹3.0 L (7.59%) | L2 | Rejected-AOC REJECTED |
| 3 | L3₹54.4 L+₹14.9 L (37.8%)Rejected-AOC | ₹54.4 L+₹14.9 L (37.8%) | L3 | Rejected-AOC REJECTED |
| 4 | Rejected-Technical GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | - | - | Rejected-Technical MOU NOT SUBMITTED |
| 5 | Rejected-Technical 602 6TH FLOOR BNG HOUSE D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | - | - | Rejected-Technical MOU AND DD NOT SUBMITTED |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Feb 2024, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
SMART PERIODICAL SERVICES TO INTERNAL AND EXTERNAL SURFACES OF BLDGS, COMMON AREA, STAIR CASE AND CONNECTED WORKS AT NCHC POWAI UNDER GE (NW) BHANDUP
2024_MES_635494_1
8313/B
Open Tender
Civil Works
Item Rate
270 days
POWAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹90,000
19 Mar 2024
2 Jan 2024
5 Feb 2024
2 Jan 2024
3 Feb 2024
20 Jan 2024
2 Jan 2024 - 12 Jan 2024
Amount
M&L for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. by skilled labour complete all as specified and directed.
M&L for waterproof cement based putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface.
M&L for one coat of acrylic water based interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.
M&L for two coats of smooth interior acrylic emulsion applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint with pro guard tehnology and capability of tracking pressure as per manufacturer instructions complete all as directed.
M&L for two coats of smooth interior acrylic emulsion with Texture finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 ltrs(undiluted) /10 sq mtrs diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions complete all as directed
M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
M&L for applying One coats of oil bound distemper to wall using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
M&L for applying One coats of oil bound distemper to ceiling using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
M&L for preparation of old wall surface and applying one coat of acrylic water based exterior grade primer @0.9 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.
M&L for preparation of old wall surface and applying one coat water based premium acrylic smooth exterior emulsion 100% weather proof, anti fungal of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.
M&L for preparation of old plastered or un plastered surface of walls, cornices etc by brooming down or steel wire brushing scrapping down smoke soot , moulds moss and efflorescent salts and trading oil and greasy spots including all necessary scaffolding and applying with automatic airless spray machine of paint applicationTwo coat cement base paint (white or tinted ) complete all as specified and directed.
M&L for preparation of old plastered or un plastered surface of walls, cornices etc by brooming down or steel wire brushing scrapping down smoke soot , moulds moss and efflorescent salts and trading oil and greasy spots including all necessary scaffolding and applying with automatic airless spray machine of paint application One coat cement base paint (white or tinted ) complete all as specified and directed.
M&L for preparation of old acrylic surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with Dr fixit crack filler or equivalent make and applying with automatic airless spray machine of paint application one coat of 100% antifungal acrylic paint of approved shade including necessary scaffolding work etc complete all as specified and directed.
M&L for one coat of synthetic enamel paint on old wooden painted surfaces including preparation of surfaces of any description not otherwise descriped over 10 cm width or grith complete all as specified.
M&L for one coat of synthetic enamel paint on steel painted surfaces including preparation of surfaces of any description not otherwise described over 10 cm width or grith complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls/ceiling etc including ranking out joints, hacking for key, scrubing down with water etc complete all as specified.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc upto 3 storie height mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note 1: - Supply only water proofing compound shall be measured and paid for separately. 2. Cost of scafolding upto 5 storied hight of building for rendering is included in this item. 3: Rendering will be done in two layer. 1st layer will be 10 mm thick and 2nd layer will be 5 mm thick.
M&L for two coat OBD on newly plastered in ceiling surface with airless electric sprayers over a coat of primer applied using airless electric sprayers over over two coats of wall care putty of 1-1.5 mm thickness prepared and sanded with electrically operated sanding machine complete all as specified and directed.
M&L for two coat OBD on newly plastered in wall surface with airless electric sprayers over a coat of primer applied using airless electric sprayers over over two coats of wall care putty of 1-1.5 mm thickness prepared and sanded with electrically operated sanding machine complete all as specified and directed.
M&L for preparation new plastered wall surface to receive finshes upto 5 storey buildings by one coat water based premium acrylic smooth exterior emulsion 100% weather proof, anti fungal of approved colour with airless spray machine of paint application complete all as directed.
M&L for preparation new plastered wall surface to receive finshes upto 5 storey buildings by two coat cement base paint of approved colour with fully automatic airless spray machine of paint application complete all as directed.
Supply only integral water proofing compound complete all as specified and directed.
Dismantling of Brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' st or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan to any radius in half thick brick built in CM(1:4) complete all as specified and directed.
S&F framed brackets of angles or other similar sections and flanges cut to shape, drilled and counter sunk for screw, including welding etc n. exc. 10 Kg each conforming to Fe290, Gde E-165 complete all as spd & directed
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/ chajjas (one side half circle crank ), fixed with self tapping screws complete all as specified and directed.
M&L for cutting Shrubs, wild growth/trees n.exc 30cm girth and removing complete vegetation growth from walls incl taking out roots from roof/brick work and making good the disturbed surface with PCC 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate including treating affected area with acid wash to check further growth of vegetation and disposing off the rubbish from site (MoD land) from the above mentioned area complete all as specified and as directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.
"Supply and Application of 4 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete WALL surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min. 50% solids, filling and sealing the cracks, then over coating with 2 Coats of NEEWP + Cement mixture as waterproofing coat having +450% Elongation followed by curing and then top-coated with 1 protective coat of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 100 - 120 microns using brush, roller, airless spray gun as applicable. The product should be certified by NABL Approved Lab and application is to be done by company approved applicator only"
M&L for Filling cracks by cutting 'V' groove cracks of internel and extrnal plaster of wall ceilling /chajjas all along the racks up to 10 mm and remove the loose plaster /concrete by suitable tools , filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and external application must be coated with paint including necessary scafolding of any hieght all as specifed and directed.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for Epoxy bond coat of Make as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor of approved make on RCC surfaces , complete all as spd and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using primer of approved make by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from of approved make as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for building up the profile of structural members using polymer modified mortar of approved make while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar of approved make exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
Dismantling cast iron of any description etc complete all as specified and directed
S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) pipe single socketed (ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single (single T ) equal or unequal with access doors etc, complete all as specified and as directed.
Note for Item above (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b.) The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected. (c) The quoted rate shall deemed to be included the surface treatment for wall upto 16 storey buildings.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 12100.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Super Construction
SB CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .