Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | ₹1.7 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.8 Cr+₹3.2 L (1.83%)Rejected-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | ₹1.8 Cr+₹3.2 L (1.83%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹1.8 Cr+₹5.9 L (3.40%)Rejected-AOC B 3 3 DHANALAXMI PARK OPP PMT BUS DEPOT BHUSARI COLONY PAUD ROAD KOTHRUD PUNE 411 038 | PUNE | PUNE | MAHARASHTRA | 411038 | ₹1.8 Cr+₹5.9 L (3.40%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹1.8 Cr+₹10.7 L (6.20%)Rejected-AOC | ₹1.8 Cr+₹10.7 L (6.20%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹1.9 Cr+₹14.3 L (8.29%)Rejected-AOC | ₹1.9 Cr+₹14.3 L (8.29%) | L5 | Rejected-AOC Being L5 |
Tender Value
Refer Docs
EMD Value
₹2.9 L
Closing Date
23 Dec 2024, 6:00 pmClosed
GE RnD Pashan
GE RnD Pashan
ADDITION/ALTERATION TO SECURITY LIGHT ALONGWITH PERIMETER WALL AT HEMRL, PUNE
2024_MES_684660_1
GERD/PSN/TOKEN/56 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE RnD Pashan
As per Tender documents
9 documents required · 9 mandatory
₹2,000
GE RnD Pashan
₹2.9 L
Yes
22 Mar 2025
20 Nov 2024
31 Dec 2024
20 Nov 2024
23 Dec 2024
16 Dec 2024
20 Nov 2024 - 1 Dec 2024
Amount
Note : The entire work shall be executed in Restricted and Hilly area. The contractor shall visit the site before quote the rates. The rate of labour and transportation for the same shall be deemed to be included in rate quoted
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws all as specified type 410 SP-31, 9 metre long complete all as specified and directed. Note : Excavation, Earth Work, PCC shall be measured and paid separately.
Painting with aluminium paint of approved brand and manufacture to give an even shade on street light poles with two coats including brackets, flat iron and clamps etc, including painting three black/red bands at lower portion of pole each of 300mm height and pole numbering after preparation of new steel surfaces by scraping with wire brush/sand paper complete all as specified and as directed by Engr-in-Charge.
Material and labour for PCC 1:4:8,Type D-2 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation filling mass concrete complete all as specified and directed.
Material and labour for PCC 1:3:6 type C1 (using 20 mm graded aggregate) as in coping weathering slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
Supply and fixing light grade GI pipe of 50mm dia (Nominal) 3 mtrs (1.5 m x 2 Nos) length along the pole/panel etc bend to shape to lay incoming and outgoing LT UG cables as per site requirement for protection of cable complete all as specified and directed by Engr-in-Charge. NOTE : (MS clamps and nuts, bolts/washers, where required are included in the unit rate quoted)
Supply and fixing light grade GI pipe of 80mm dia (Nominal) laid in trenches/road/culvert etc as per site requirement for protection of under ground cable complete all as specified and directed by engr-in-charge.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge. Make : Crompton Greaves/Havells/Philips/Wipro/Bajaj
Supply and fixing 40 mm dia x 1.5 metres long GI pipe (medium class) bracket for mounting of street light fitting on pole including bending the pipe to the required shape, 2 Nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and synthetic enamel paint etc complete all as specified and as directed by Engr-in-Charge.
Taking down existing unserviceable LT UG cable of size upto 95/120 Sqmm 3.5 core complete all as specified and directed by Emgr-in-charge,
Taking down existing unserviceable LT UG cable of size upto 16 Sqmm 4.0 core complete all as specified and directed by Emgr-in-charge,
Supply, laying, testing and commissioning UG cable, XLPE insulated screened PVC bedded, galvanised steel strip screened or wire armoured electic power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of120 Sqmm 3.5 core including necessary lugs and cable glands laid in trenches/floors complete all as specified and directed by Engr-in-Charge. Note : Excavation earth work cable cushion, cable protection shall be measured and paid separately. (a) 120 Sqmm 3.5 core
(b) All as per item No 10 here-in-before but 95 Sqmm 3.5 core
(c) All as per item No 10 here-in-before but 16 Sqmm 4 core
Supply and drawing 3 X 1.5 sq mm size FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ in the existing steel swaged pole as required complete all as specified and directed by engr-in-Charge. Note : 3 runs of cable shall be measured as one length)
Supply and fix pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 250mm X 200mm X 105 mm (internal ) comprising of 63A power terminal block 4 ways, one No SP MCB single pole of capacity 6 Amps 240 volts duly fixed on DIN rail 'C' type and one No terminal for loop in & loop out suitable for three phase street light system including nuts and bolts and washers, MS clamp fabricated from 25mm x 3mm MS flat iron complete mounted on pole complete all as specified and directed.
Supply and fixing Austronomical Street light timer panel of rating 12 kW, conforms to IS/IEC 60947-4-1, provided with Protection Degree IP 54, extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation including 65 Amps TP MCB 'C' Curve, 10 KA, 415V one No. and MCB SPN 63A, 'C' curve, 10 KA, 415V one No., all as required complete all as specified and directed by Engr-in-Charge Make : Havells/L&T/Legrand
Material and labour for special factory made earthing electrode comprising of hot dipped galvaized MS flat inserted in to GI pipe of 88mm bore (outer), 3 metre length, filled with non magnetic anti corrosive material specially developed for ground resistance enhancement power around the electrode to retain moisture conforming to IS 3043 including necessary boring in ground of 150 mm dia in any type of soil / strata connecting to test point all as specified and directed (the earth resistance shall be less than 1 ohm complete all as specified and directed. Contractor shall improve the earthing resistance within the permissible limit without any extra cost. Note:-GI earthing pipe should have successfully tested for salt spray test (corrosion test) Certificate for minimum 500 hours. The Earth Enhancing Compound should have Test certification from NABL accredited Lab. It should be tested as per IS 1350/ AHPA guideline’s. The pH value of Compound should be 7.59, Moisture % by mass should be 8.91& Solubility in 1:1 HCL should be 32.29 %. The Compound should be tested ELV Test as per protocol IEC 62321/111/54/CDV/ICP-OES for contain of Lead (23.0 ppm), Cadmium (15.0ppm), Mercury (Below Detection Level) & Hexa-chromium(Below Detection Level) (ii) Rate for FRP earthing pit cover shall be deemed to be included in rate quoted.
Supply and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc as required at site complete all as specified and directed.
Supply and fixing 6 SWG dia GI wire on surface or in recess for connections etc as required at site Gcomplete all as specified and directed.
Supply, installing, testing and commissioning of silent Diesel Engine Driven Generating Set, 415 Volts, 40 KVA (32KW), 3 Phase, 4 wire, 0.8 Power Factor, 50 Hz, 1500 RPM, radiator cooled engine, self excited, self regulated brushless AC generator suitable for ambient conditions complete with sound proof canopy as per CPCB IV norms, with battery, Control panel for automatic starting on main failure installed on cement concrete foundation as per recommendation of manufacturer and 60 cm above ground level complete all as specified in description given below and directed. (a) Diesel Engine : Diesel engine suitable BHP at 1500 RPM multi cylinder 4 stroke, water cooled, Electrical starter motor with soft start engagement feature, Coolant heater, Oil drain pump, Heavy duty air cleaner, Electronic Governing, Optimised turbocharger for increased altitude capabilities, Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature etc and ARAI approved capable of taking 10% over loading, 12 hour of continuous operation. The engine shall be fitted complete with all the required accessories. (b) Control panel shall be manufactured with 2 mm thick CRCA sheet and powder coated for weather-proof and long lasting finish. The control panel consists of the following parts :- (i) Microprocessor based generator set monitoring and control system. This control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics. Intuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches and generator set status LED lamps, Remote Start-Stop, Engine Metering : Oil pressure, Engine temperature, Starting battery voltage, Engine running hours, AC Alternator Metering : L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. Engine Protection : Low lube oil pressure, High/Low coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/ Start, Sensor failure, Cranking lockout, Low fuel level. AC Alternator Protection : Over/Under Voltage, Over/Under Frequency, Loss of AC Sensing. Data Logging : Engine Hours, Control Hours and upto 5 recent fault codes Configurable glow plug control, 12 Volt DC operation, Sleep mode, Modbus interface (RS485 RTU), InPower compatible (PC based service tool). (ii) Automatic starting on main failure as per the manufacturer standard practice and specification complete with Aluminum bus bars with suitable capacity of incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’. (iii) Instrument fuses duly wired and ferruled. (iv) Circuit breakers of suitable rating with overload and short circuit protections. (c) Alternator : Synchronous alternator rated at 40 KVA, 415 Volts at 1500 RPM 3 phase 50 Hz, AC supply, Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1, Compact design with sealed bearings and ƒImpregnation on all wound components suitable for tropical conditions and with class F/H insulations. (d) Mounting Arrangement : Engine and alternator shall be mounted on a common MS fabricated base frame with AVM pads. Base frame with integral fuel tank shall be provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning. (e) Fuel Tank : Daily service fuel tank of capacity as per manufacturer standard specification fabricated out of MS sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class C pipe of suitable dia complete with valves. (f) Exhaust System : Dry exhaust manifold with hospital exhaust silencer and catalytic converter. (g) Starting System : 12 V/24 V starting system comprising of starter motors, voltage regulator and arrangement for initial excitation complete with suitable Nos of batteries (lead acid type) as required as per specification. (iii) Instrument fuses duly wired and ferruled. (iv) Circuit breakers of suitable rating with overload and short circuit protections. (h) Acoustic Enclosure : Specially designed to meet stringent CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions. The acoustic enclosure is made of CRCA sheets and a structural/ sheet metal base frame painted in black, High quality noise absorbent and fire-retardant grade acoustic Insulation material (Foam) complying to IS 8183, Two point lifting for easy handling, Air inlet louvers specially designed to operate at rated load, 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling arrangement inside the enclosure etc. Notes : PCC and earth work for DG set foundation shall be deemed to be included in quoted rates
Supply, installing, testing and commissioning of silent Diesel Engine Driven Generating Set, 415 Volts, 82.5 KVA (66KW), 3 Phase, 4 wire, 0.8 Power Factor, 50 Hz, 1500 RPM, radiator cooled engine, self excited, self regulated brushless AC generator suitable for ambient conditions complete with sound proof canopy as per CPCB IV norms, with battery, Control panel for automatic starting on main failure installed on cement concrete foundation as per recommendation of manufacturer and 60 cm above ground level complete all as specified in description given below and directed. (a) Diesel Engine : Diesel engine suitable BHP at 1500 RPM multi cylinder 4 stroke, water cooled, Electrical starter motor with soft start engagement feature, Coolant heater, Oil drain pump, Heavy duty air cleaner, Electronic Governing, Optimised turbocharger for increased altitude capabilities, Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature etc and ARAI approved capable of taking 10% over loading, 12 hour of continuous operation. The engine shall be fitted complete with all the required accessories. (b) Control panel shall be manufactured with 2 mm thick CRCA sheet and powder coated for weather-proof and long lasting finish. The control panel consists of the following parts :- (i) Microprocessor based generator set monitoring and control system. This control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics. Intuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches and generator set status LED lamps, Remote Start-Stop, Engine Metering : Oil pressure, Engine temperature, Starting battery voltage, Engine running hours, AC Alternator Metering : L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. Engine Protection : Low lube oil pressure, High/Low coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/ Start, Sensor failure, Cranking lockout, Low fuel level. AC Alternator Protection : Over/Under Voltage, Over/Under Frequency, Loss of AC Sensing. Data Logging : Engine Hours, Control Hours and upto 5 recent fault codes Configurable glow plug control, 12 Volt DC operation, Sleep mode, Modbus interface (RS485 RTU), InPower compatible (PC based service tool). (ii) Automatic starting on main failure as per the manufacturer standard practice and specification complete with Aluminum bus bars with suitable capacity of incoming/outgoing terminals Indicating lamps for ‘Load ON’ and ‘Set Running’. (iii) Instrument fuses duly wired and ferruled. (iv) Circuit breakers of suitable rating with overload and short circuit protections. (c) Alternator : Synchronous alternator rated at 82.5 KVA, 415 Volts at 1500 RPM 3 phase 50 Hz, AC supply, Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1, Compact design with sealed bearings and ƒImpregnation on all wound components suitable for tropical conditions and with class F/H insulations. (d) Mounting Arrangement : Engine and alternator shall be mounted on a common MS fabricated base frame with AVM pads. Base frame with integral fuel tank shall be provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning. (e) Fuel Tank : Daily service fuel tank of capacity as per manufacturer standard specification fabricated out of MS sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class C pipe of suitable dia complete with valves. (f) Exhaust System : Dry exhaust manifold with hospital exhaust silencer and catalytic converter. (g) Starting System : 12 V/24 V starting system comprising of starter motors, voltage regulator and arrangement for initial excitation complete with suitable Nos of batteries (lead acid type) as required as per specification. (iii) Instrument fuses duly wired and ferruled. (iv) Circuit breakers of suitable rating with overload and short circuit protections. (h) Acoustic Enclosure : Specially designed to meet stringent CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions. The acoustic enclosure is made of CRCA sheets and a structural/ sheet metal base frame painted in black, High quality noise absorbent and fire-retardant grade acoustic Insulation material (Foam) complying to IS 8183, Two point lifting for easy handling, Air inlet louvers specially designed to operate at rated load, 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling arrangement inside the enclosure etc. Note : PCC and earth work for DG set foundation shall be deemed to be included in quoted rates
Supply, fix, connecting, testing and commissioining of high intensity, long range, auto-swivel, LED search light, beam range 500 meters (min), 1x200W single, LED light efficiency > 130 lm/w, PF > 0.95, CCT 5500K - 6500K, Optical grade PMMA-PC lens, anti - UV oxidation, narrow beam 8 degree, die cast LM6 body with air fins, fully powder coated, working voltage 150-270, 50hz, constant current, reflector/lens efficiency > 90% average lux level at 5 meter - 9000 (min) with circle of approx 600mm, IP-65, confirming to LM79 / LM80 hrs, search light should be installed on disc of revolving mechanism with suitable motor-gear unit and design such to rotate 360 degree continuously over the night in horizontal plane with speed controller (1 to 10 rpm) & R/F buttons and inbuilt push to tilting option upto 45 degree. A separate wall mounted wired control panel (consist of MCB's, V-meter, Fuse, LED indicators) is supplied for smooth & safe operation remotely. The revolving mechanism is fully covered with weather & rust proof fiber box with maintenance window/door and provision of 4 nos. foundation holes at bottom for proper installation including necessary civil work as required.
Dismantling and taking down street light fittings with bracket, wire and junction box for repair or replacement of burnt/worn out accessories or carrying for Schedule of credit complete all as specified and directed by Engr-in-Charge
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/ LT under ground cable/pole foundation and getting out soft/loose soil complete all as specified and as directed:-
All as per item No 25 here-in before but Hard / Dense Soil
All as per item No 25 here-in before Soft/ Disintegrated rock
All as per item No 25 here-in before Hard Rock (blasting prohibited).
Excavation in trenches not exceeding 1.5 metre wide and depth exc 1.5 metre and n exc 3.0 m for taking out/erection LT Pole and getting out in soft/loose soil complete all as specified and as directed by Engr-in charge.
All as per item No 29 above but as in Hard / Dense Soil
All as per item No 29 above but as in Soft/ Disintegrated rock
All as per item No 29 above but as in Hard Rock (blasting prohibited)
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class LV, Type-I, flat of size 250mm X 150mm x 40mm thick complete all as specified and directed by Engr-in-Charge
Material and labour for dry crushed stone sand filling in trenches to required width at bottom and top of cable cushioning including spreading leveling and consolidation complete all as specified and directed. Note : Punned thickness shall only be measured and paid.
Cutting Bituminous road/hard standing and making good the same with PCC 1:2:4 using 20mm graded stone aggregate complete all as specified and directed by Engr-in-Charge
Supplying and fixig cable route marker with 10cm x 10 cm x 5 mm thick GI plate with inspription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required complete all as specified and directed by Engr-in-Charge.
Earthling complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground (in any type of strata) (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion. Note : The quoted rate deemed to include cost of excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, type C1 40mm thick RCC 1:2:4, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with GI watering pipe 20mm dia medium grade, wire mesh, protection pipe 40mm dia GI pipe light grade for earth lead upto 7.50 metre long complete all as specified and directed.
Dismantling of existing coping of street light pole complete all as specified and directed
Painting with aluminium paint of approved brand and manufacture to give an even shade on existing street light poles with two coats including brackets, flat iron and clamps etc, painting three black/red bands at lower portion of pole each of 300mm height and pole numbering after removing old paint by paint removers and cleaning with scrappers complete all as specified and directed by Engr-in-Charge
om sai enterprises (BID ID -3196086)
Baljeet Singh Choudhari (BID ID -3195752)
SHAH BUILDERS (BID ID -3190526)
Mourya Construction (BID ID -3196182)
Prasur Electricals & Engineering Co. (BID ID -3196116)
Shree Ayyappa Engineering (BID ID -3196245)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .