Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical BHU | Admitted-Fee/PreQual/Technical |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
4 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) E/M CHAKERI
O/o GE(AF) E/M CHAKERI
UPGRADATION OF HT DISTRIBUTION SYSTEM WITH DISTRIBUTION TRANSFORMER MONITORING UNITS FOR PREVENTIVE MAINTENANCE AT AFS KANPUR.
2026_MES_794031_1
8847/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Area under GE(AF) E/M Chakeri
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE(AF) E/M Chakeri
₹1 L
Yes
11 Nov 2026
15 Oct 2026
11 Nov 2026
15 Oct 2026
4 Nov 2026
29 Oct 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending to transformer complaint 24 hrs of capacity uo to 63 KVA 400 KVA tripping including meggaring of the cables and checking the physicall condition of the transformer and assessing the physical condition and, checking oil level, conducting electrical LT testing like, measuring of IR values, ratio test, magnetic balance test, oil BDV test to assess the healtness of the windings and if found statisfactory, then connections of the cable terminations and make arrange for charging the transformer, if transformer is found faulty, then recommended for the further repair/rewinding works to be carried out put back the transformer into service all as specified and directed | 12 | Each Job | 1.25 | ₹15 |
| - | All as per item no. 01 here-in-before but for transformer apacity 500 KVA to 2000 KVA 11/0.415 KV | 10 | Each Job | - | - |
| - | Overhauling of transformers of capacity up to 63 to 400 KVA opening of top cover in situ or at wksp by unscrewing all nuts, bolts & washers, draining out transformer oil upto required level and keeping in clean container for repair/replacement of HT/LT bushings, tap changer, physical check of any defects, for lifting of core assy, for cleanning/repair and refixing top cover complete with RC 70 C rubberised cork sheet gasket sheet, existing/nenuts, bolts & washers for transformer indoor/outddoor type. The transformer to be put inside the hearting chamber for IR valuess imporvement , refilling of oil for transformer all as specified and directed. Note :- (a) HT/LT bushings, stud, tap changer, nuts, bolts & washers requirednew shall be measured separately here-in-after (b) silicom oil proof gusket shall be inclusive of quoted rate. (c) nTransportation and loading and unloading charge to be measured and paid included. | 10 | Each Job | 100 | ₹1,000 |
| - | all as per item No. 03 here-in-above but for transformer capacity 500 KVA to 2000 KVA, 11/0.415 KV. | 10 | Each Job | 53 | ₹530 |
| - | M & L for filtration/dehydratyion transformer oil of transformer voltage grade 11/0.415 KV, 63 KVA to 2000 KVA capacity indoor/oput door type, in situ till achieve dielectric strength minimum 60 KV at 4mm gap all as specified and directed. | 11,000 | Ltr | 10 | ₹1,10,000 |
| - | M&L for toping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 voltd grade including necessary dehydration to achieve dielectric strerngth min 40 KV at 4 mm gapall as specified and directed. | 1,000 | Ltr | - | - |
| - | M &L for shifting of transformer of capacity 63 KVA to 2000 KVA from its position and transportation by vehicle to other location n exc 5 KM inside Air Force station incl all cable/earth connections all as specified and directed. (Note :- rate for dismentling of HT/LT cable & earthing and reconnection after installation deemed to be included in the quoted rate (b) necessary crane for lifting of transformer and vehicle for transportation shall be arrange by the contractor and deemed to be included in the quoted rate) | 3 | Each Job | 100 | ₹300 |
| - | M&L for complete painting of transformer outer surface in situ/wksp with one coat of synthetic enamel paint using sprayer for transformer capacity 63 to 2000 KVA after prliminary preparation of old painted surface (Note : during process of painting , transformer will be under shut down for the period and the rate deemed to be included for running the sprayer machine with alternative arrangment by the contracotr. (ii) After completion of painting HT/LT outdoor bushing, cable termination joint, oil inspection glass meters and name plates to be made clean using volatile cleaner) | 40 | Each Job | 53 | ₹2,120 |
| - | Maintenance and attending break down of of transformer to VCB/RMU/ACBs/ Transformer/LT panels of sub stations and upto main distribution boards at buildings, over head lines, street lights including attending minor repairs and day to day maintenance of panels for smooth and trouble free power supply , rectification of minor defects to electrical controls and accessories and attending break down at any time round the clock all as specified and directed. Note : The rate quoted is inclusive of the following :- (a) Attending minor repairs/breakdown without involving any new materials shall be deemed to be included in the unit rate (b) Major repairs/break down involving supply and fixing of materials such as cables, cable joints MCCBs etc are outside scope of contract | 30 | Each Job | - | - |
| - | Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for HT / LT underground cable / pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed. | 135 | Cum | 100 | ₹13,500 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
Workdetails.pdf
Additional Documents • 0.09 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
8847_tender_1.pdf
Tender Documents • 0.82 MB
8847E8_CreditSchdule_1.pdf
Additional Documents • 0.26 MB
BOQ_890521.xls
BOQ • 1.75 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .