Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.7 L+₹1.5 L (5.04%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹32.2 L+₹3.0 L (10.2%)Rejected-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L3 | Rejected-AOC L3 | |
| 4 | L4₹36.4 L+₹7.2 L (24.6%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
14 Jul 2023, 6:00 pmClosed
CWE (AF) Borjhar
HQ CWE (AF) Borjhar, Military Engineer Services, PO - Borjhar Airport, Guwahati (Assam) - 781015 Tele 0361 2841626
SPECIAL REPAIR TO ROOF AND WALL WITH ALLIED WORKS AT CERTAIN LOCATIONS AT AFS DIGARU
2023_MES_603825_1
CWE(AF)/DIG/TOKEN-04 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Digaru
Please refer Tender documents
8 documents required · 8 mandatory
₹500
Yes
AGE (I) (AF) Digaru
₹87,000
Yes
16 Aug 2023
16 Jun 2023
21 Jul 2023
16 Jun 2023
14 Jul 2023
30 Jun 2023
Amount
SCHEDULE 'A' PART-I (B/R PORTION)
Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Excavation in trenches n exc. 1.5 m wide and n. exc. 1.5 m depth for foundation etc. n. exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
All as per Item No 2 above but depth beyond 1.5m and n.exc. 3.00m complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance exc. 50 m but n.exc. 1.50 KM and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
PCC (1:4:8) type D-2 (using 40mm graded stone aggregates) as in foundations, fillings and mass concrete complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat rough finished surface of concrete complete all as specified and as directed.
M&L Formwork to sides of pillars,posts, struts, piers, columns and stanchions, square, rectangular or polygonal rough finished surface of concrete complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc.for flat rough finished surfaces complete all as specified and as directed.
M&L TMT bars 10 mm dia and over cut to length bend to shape required, including cranking, bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and as directed
Description all as per Item No 10 above but 5 mm dia and over upto 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 disgn mix using 20 mm grade stone aggregate as in Columns, pillars, piers,posts and struts complete all as specified and directed.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L brick work with sub class 'B' bricks strait or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and as directed.
M&L for rendering 15 mm thick in CM (1:4) on internal surfaces of wall complete all as specified and as directed.
M&L for preparation of newly plastered surface and applying two coat of Acrylic Smooth exterior paint of required shade applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as per manufacturer instruction.
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance 50 m and n.exc. 100m including roughening of old surface of roof by wire brushing and cleaning the surface to remove the loose dust complete all as specified
M&L for 15 mm thick screed bed or bedding layers in cement mortar 1:4 mixed with liquid WPC as per manufacturer's instruction in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, finished even and smooth without using extra cement and Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m including APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including applying aluminium paint over APP based polymeric membrane @ 0.11 Kg /Sqm complete all as specified and as directed.
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm graded stone agg., for filling up the undulation on RCC roof slab, chajjas ,roof kerbs etc. to maintain slope complete all as specified and directed.
Supply only liquid water proofing all as specified and directed.
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
Dismantling wall and ceiling boards (fibre,pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed.
S&F Anodised aluminium snap grid frame work main Tee & cross Tee size 25.40X25.40X1.63 mm supported at ends with 38.10X25.40X1.32 mm forming grid 600x600 mm for false ceiling, suspended with 6 mm GI wire , (upto 1200mm length). Adjusting level fixed to roof slab by means of ceilling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasterners 12.5mm dia 40 mm long complete all as specified and directed.
M&L for providing and fixing gypsum board 10 mm, thick in ceiling fixed with screws as per manufacturer instruction
M&L for 6mm thick non Asbestos fibre cement building boards, fixed or laid/inserted to Aluminium framework with screws complete all as specified and directed
M&L for preparation of new ceiling surfaces and applying two coat of oil bound distemper complete all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Supply and fix pre painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and directed
S&F pre painted galvalume aluminium zinc coating plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and as directed
Dismantling wrought iron MS work of any description not otherwise provided for complete all as specified and as directed
S&F steel work in tubular purlins post, rafter including necessary cutting welding etc complete all as specified and as directed
S&F in repair galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc as directed (each line wire to be measured and paid)
Fixing only, galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc as directed.
S/F MS steel post struts fencing post including cutting top to shape,drilling holes notching for wire etc including all necessary drilling bolting andd similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
M&L for providing, cement concrete type B0 1:2:4 ,using 12.5mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edgesin lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth not otherwise described complete all as specified and as directed.
M/S DAS CONSTRUCTION
Ms N D Enterpise
FRIENDS ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .