Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹37.7 L+₹49,110 (1.32%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹43.0 L+₹5.8 L (15.6%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹45.5 L+₹8.3 L (22.3%)Rejected-AOC 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L4 | Rejected-AOC L4 Bidder | |
| 5 | L5₹45.6 L+₹8.4 L (22.7%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L5 | Rejected-AOC L5 Bidder |
Tender Value
Refer Docs
EMD Value
₹99,460
Closing Date
8 Jul 2021, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
AUGMENTATION/MODIFICATION OF FIRE PROTECTION SYSTEM FOR NEW BUILDING AT CFEES UNDER GE I RND DELHI
2021_MES_435966_1
GE/RND-20/DLI/2021-2022
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class D, Cat c(vi)
2 documents required · 2 mandatory
₹500
GE I RND DELH
₹99,460
Yes
17 Jul 2021
12 Apr 2021
10 Jul 2021
12 Apr 2021
8 Jul 2021
26 Jun 2021
Amount
Supply, Installation, Testing and Commissioning of 4 loop Addressable fire alarm panel Epoxy powder coated, with loop capacity of 126 devices per loop, IP30 protection, 16 zonal LED indicators, 2 programmable sounder circuit, large graphic display, sensitive adjustment and drift compensation, variable language and character settings and supports Apollo protocols complete all as specified and directed. The panel should have an integral 240 X 64 pixel graphic LCD and built-in 220 VAC power supply with battery charger capable of charging 02 nos X 07 Ah 12 VDC batteries. The panel should support both 'A' class and 'B' class wiring with user friendly interface and should have 05 nos digital inputs for silence, reset, fault etc and daily/weekly/monthly/yearly backup facility. The panel should also have provision for graphic software with TCP/IP and provision for BMS integration over MODBUS protocol. The panel should be EN-54/LPCB/UL/VDS approved. The panel should clearly indicate the following indications: o POWER ON green LED indicator o FIRE ALARM red LED indicator o PRE-ALARM yellow LED indicator o ON TEST yellow LED indicator o BUZZER SILENCED yellow LED indicator o DELAY ACTIVE yellow LED indicator o MORE EVENTS yellow LED indicator o GENERAL DISABLEMENT yellow LED indicator o GENERAL FAULT yellow LED indicator o POWER FAULT yellow LED indicator o SYSTEM FAULT yellow LED indicator
Supply, Installation, Testing and Commissioning of Active Repeater panel Epoxy powder coated, with IP30 protection, 16 zonal LED indicators, 2 programmable sounder circuit, large graphic display, sensitive adjustment and drift compensation, variable language and character settings and supports Apollo protocols complete all as specified and directed. Note:- The panel shall be EN-54/LPCB/UL/VDS approved.
Supply, Installation, Testing and Commissioning of Apollo Addressible Multi sensor smoke & Heat Detector with a base as required complete all as specified and directed.
Supply, laying of multi stranded copper conductor PVC insulated, unsheathed FRLSH cable 2 core 1.5 sqmm ISI marked complete all as specified and directed.
Supply, laying of multi stranded copper conductor PVC insulated, unsheathed FRLSH cable 4 core 1.5 sqmm ISI marked complete all as specified and directed.
Supply, Installation, Testing and Commissioning of dust and vermin proof addressable analogue manual call boxes with flashing LED with isolator to initiate audio visual alarm in case of human detection of fire complete all as specified and directed. Note: The manual call point shall be EN-54/LPCB/UL/VDS approved and compatible with the addressable fire alarm panel.
Supply, Installation, Testing and Commissioning of addressable loop sounder cum strobe suitable for audio and visual alarm siren upto 90 dBA @ 1 m and 15 cd flashing complete all as specified and directed. Note: The sounder cum strobe shall be EN-54/LPCB/UL/VDS approved and compatible with the addressable fire alarm panel.
Supply, Installation, Testing and Commissioning of addressable control module required for various outputs to other systems , access control etc. complete all as specified and directed. The control module should be EN-54/LPCB/UL/VDS approved.
Supply and fixing of Response Indicator complete all as specified and directed.
Supply and fixing in repair of swinging type First Aid hose reel (IS:884-1985) in red colour drum with 30 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia gate gun metal valve stop cock, (IS:778, class-II) terminating with SS coupling & nozzle of 6 mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastener, bolts & nuts complete all as specified and directed.
Supply and fixing in repair SS (Stainless Steel) Single head landing valve with 80 mm N.B. flanged inlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290. Including fixing with anchor fastener and flanged tapping from wet riser. (For Internal Hydrant/Outer Hydrant post) complete all as specified and directed.
Supply and fixing in repair of Non-percolating rubber reinforced lined fire hose pipe (as per IS : 636) Type-A of 63 mm dia and 15 mts long as described below. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & riveted to hose pipe with aluminum rivets & 1.5 mm GI wire. (For Internal Hydrant) complete all as specified and directed.
S&F in repair 63 mm dia instantaneous pattern SS (Stainless Steel) Short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Supply and fixing Photoluminiscent Gas Release caution sign board complete with fixing arrangements
Supply of ABC type stored pressure 6 kg fire extinguisher ISI marked under IS 15683 complete in all respect.
Supply of CO2 type 4.5 kg fire extinguisher ISI Marked complete in all respect.
Supply, Installation, Testing and commissioning of 120 Watt Amplifier.
Supply, Installation, Testing and commissioning of 6 Watt ceiling/Wall Speaker.
Supply, Installation, Testing and commissioning of Microphone for announcement compatible with the public addressable system complete all as specified and directed.
Supply and laying of public address system wire 2 core, PVC insulator Copper conductor of suitable size (min 1.5 Sqmm), required size medium grade PVC conduit complete all as directed and directed.
Supply, Installation, Testing and commissioning of Single master and 8 way slave for talk back PA system complete as required.
M&L for fixing of Steel conduit of size 20 mm on wall/ ceiling with clamps, screw and all connected items all as directed.
M&L for fixing of Steel conduit of size 25mm on wall/ ceiling with clamps, screw and all connected items all as directed.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core complete all as specified and directed.
M&L for servicing to monoblock motor and pump set 7.5 HP with greasing and replacement of elctrical terminal including painting complete all as specified and directed.
S&F in repair MS sheet/angle with enamel paint two coat over one coat of red oxide primer complete all as specified and directed.
S&F in repair of automatic star-delta motor starter in sheet metal enclosure type ML suitable for 3 phase electric motor of capacity upto 7.5 HP, 3 phase 415V complete all as specified and directed.
S&F in repair of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed.
M&L for painting with two coat of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed.
S&F in repair of Solonoid valve with complete wiring and cover.
S&F in repair of Solonoid switch with box complete wiring and cover.
S&F MS ERW pipe of bore 150 mm confirming to IS-1259 PART-2, medium grade complete all as specified and directed.
S&F MS ERW pipe of bore 100 mm confirming to IS-1259 PART-2, medium grade complete all as specified and directed.
S&F Non Return Sluice Valve of dia 100 mm confirming to IS-5312 PART-2, complete all as specified and directed.
S&F Non Return Sluice Valve of dia 150 mm confirming to IS-5312 PART-2, complete all as specified and directed.
Supply and fix 150mm bore hand operated butterfly valve of pressure not less than 15 Kg/Sqcm with complete set complete all as specified and directed.
Supply and fixing sluice valve 100 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed.
Supply and fixing sluice valve 150 mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed.
M&L for Pressure gauge 4"dial 0-14 kgs rating complete all as specified and directed.
M&L Yard hydrant Post / Stand Post 80mm Dia MS both flanged type 1.5m Height complete all as specified and directed.
M&L for hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed.
Supply and fix Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two way 63 mm dia instantaneous type male coupling with built in check valve and 150 mm dia , flanged out let complete with all accessories.
Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out complete all as specified and as directed.
All as per item No. 44 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc complete all as specified and as directed.
Returning, filling and including spreading, leveling watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed complete all as specified and as directed.
Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed.
M&L for bocky system under path/road to pass the MS ERW pipe of 150 mm dia manually complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) finished even and smoooth without using extra cement as on brick pillars complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. Complete all as specified and directed.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:6, complete all as specified and directed.
Taking down Aluminium windows or of any descriptions with shutters area not exc 1.50 sqm each complete all as specified and as directed.
S&F aluminium powder coated section of size 63.50x38.10x1.60mm thick as in frame for aluminium door shutter fixed to walls etc with rawl plugs and steel screws incl all cuttings etc for fixing pivots complete all as specified and as directed.
S&F 50 micron thick powder coated aluminium section swing door shutters partly panelled and partly glazed comprising top rail 85.00mmX44.45mmX2.70mm, bottom rail 150mmX44.45mmX2.20mm, lock rail 150X44.45mmX3.00mm and styles 47.62mmX44.45mmX1.62mm And including jointing cleats,alum snap beading , rubber gasket glazing clips and two Nos disc type handles and one nos alum tower bolt 200mm long for each leaf on one side and 01 no 6 lever dead lock of brass for each leaf fixed in position complete all as specified and as directed.
S&F Floor door stopper of aluminium alloy body and tonge anodised with hard drawn steel spring with overall length of cover plate 150mm all as specified.
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty and fixed all as specified.
M&L 12 mm thick Prelaminated particle board, interior grade, prelaminated on both side with decorative choice laminations, fixed to aluminium frame work anodised aluminium beading complete all as specified and as directed.
S&F 4.8 mm thick Sheet glass, ordinary quality of any colour, fixed with aluminium glazing clips, rubber beading / gaskets in area exc 0.5 sq. m in each pane complete all as specified and as directed.
M&L for plain Cement concrete type C2 1:3:6 (using 20mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L mild steel work as in Stairs (framed) including stringers, treads, landing, balusters, hand rails etc. including cleats, brackets, etc. complete all as specified and as directed.
M&L mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for plain cement concrete type C2, 1:3:6 (40 mm graded crushed stone aggregate) 75 mm thick as in subbase complete all as specified and directed.
M&L for cement concrete type B-1,1:2:4 (20mm graded crushed stone aggregate) 25 mm thick as in floor finish complete all as specified and directed.
Removing excavated material exc 1.5 Km but not exc 5 KM outside MoD land complete all as specified and directed
FORTUNE STAR
Continental Engineers and contractors
ALPHA ENGINEERS AND BUILDERS
Pradeep Bros
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .