Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.0 LAdmitted-Finance | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Trade Linkers Associates L1 |
|---|---|---|---|---|
| 1.00Current Transformer (at 220/132/66/33 KV Voltage level) | ||||
| 2.00 | Single phase,50c/s,245KVCurrent Transformer (1200-800-400/1-1-1-1-1 A) 40KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA, 4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 5,00,000 ₹5,00,000 Lowest |
| 3.00 | Single phase,50c/s,245kv Current Transformer (1600-1200-800/1-1-1-1-1 A) 40KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 5,00,000 ₹5,00,000 Lowest |
| 4.00 | Single phase,50c/s,245kv Current Transformer (1600-800-400/1-1-1-1-1 A) 40KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 5,00,000 ₹5,00,000 Lowest |
| 5.00 | Single phase,50c/s,145kv Current Transformer (1200-600-300/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 1,88,000 ₹1,88,000 Lowest |
| 6.00 | Single phase,50c/s,145kv Current Transformer (2000-1600-1200/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 1,88,000 ₹1,88,000 Lowest |
| 7.00 | Single phase,50c/s,145kv Current Transformer (1200-800-400/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 1,88,000 ₹1,88,000 Lowest |
| 8.00 | Single phase,50c/s,145kv Current Transformer (1200-800-600/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 1,88,000 ₹1,88,000 Lowest |
| 9.00 | Single phase,50c/s,145kv Current Transformer (600-300-150/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA, 4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 1,88,000 ₹1,88,000 Lowest |
| 10.00 | Single phase,50c/s,145kv Current Transformer (1600-800-400/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA, 4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors | 1 | Nos | 1,88,000 ₹1,88,000 Lowest |
Tender Value
₹60.3 L
EMD Value
₹1.2 L
Closing Date
15 Oct 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER TLMD-II GLADNI JKPTCL JAMMU
OFFICE OF THE EXECUTIVE ENGINEER TLMD-II GLADNI NARWAL JKPTCL JAMMU.
REQUIREMENT OF SPARE EQUIPMENTS (CIRCUIT BREAKERS CTs PTs LAs ETC TO MEET EMERGENCY BREAKDOWN AT ANY OF THE GRID STATIONS FALLING UNDER JKPTCL JAMMU
2025_PDD_284170_1
TLMD-II/J/05 OF 2025-26 Dated 14-08-2025
Open Tender
Electrical Goods/Equipments
Item Rate
120 days
Gladni
As per NIT and SBD
3 documents required · 3 mandatory
₹2,400
EXECUTIVE ENGINEER TLMD-II GLADNI JKPTCL JAMMU
₹1.2 L
24 Oct 2025
14 Aug 2025
17 Oct 2025
18 Aug 2025
15 Oct 2025
19 Aug 2025
Amount
Current Transformer (at 220/132/66/33 KV Voltage level)
Single phase,50c/s,245KVCurrent Transformer (1200-800-400/1-1-1-1-1 A) 40KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA, 4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,245kv Current Transformer (1600-1200-800/1-1-1-1-1 A) 40KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,245kv Current Transformer (1600-800-400/1-1-1-1-1 A) 40KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,145kv Current Transformer (1200-600-300/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,145kv Current Transformer (2000-1600-1200/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,145kv Current Transformer (1200-800-400/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,145kv Current Transformer (1200-800-600/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,145kv Current Transformer (600-300-150/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA, 4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,145kv Current Transformer (1600-800-400/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA, 4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,145kv Current Transformer (900-600-300/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,72.5kv Current Transformer (1200-600-300/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,72.5kv Current Transformer (1600-800-400/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA, 4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,72.5kv Current Transformer (600-300-150/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,72.5kv Current Transformer (400-200-100/1-1-1-1-1 A) 31.5KA for one second, rated dynamic current 100KA (peak), Class A Insulation, Burden 20VA,4 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,36kv Current Transformer (1200-600-300/1-1-1 A) 25KA for one second, rated dynamic current 25KA (peak), Class A Insulation, Burden 20VA, 2 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,36kv Current Transformer (1200-800-400/1-1-1 A) 25KA for one second, rated dynamic current 25KA (peak), Class A Insulation, Burden 20VA, 2Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,36kv Current Transformer (50-25-12.5/1-1-1 A) 25KA for one second, rated dynamic current 25KA (peak), Class A Insulation, Burden 20VA, 2 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Single phase,50c/s,36kv Current Transformer (800-400-200/1-1-1 A) 25KA for one second, rated dynamic current 25KA (peak), Class A Insulation, Burden 20VA, 2 Nos. PS Core, 01 No. 0.2s class, galvanized tank including first fill of transformer oil plus 20% extra and all acessories, auxiliaries, terminal connectors
Potential Transformer (132 KV Voltage level)
Single phase 50 c/s 132KV Capacitor voltage Transformer (132/1.733)KV/(110/1.733)V one min power freq withstand 275KVrms, Galvanized Tank, ACC Class 0.2
Lightning Arrestor (66/33 KV Voltage level)
Single phase 50 c/s outdoor metal oxide gapless type,60KV(rms) surge arrestor including surge counter/monitors, insulating base and all associated accessories, auxiliaries complete in all respects.
Single phase 50 c/s outdoor metal oxide gapless type,30KV(rms) surge arrestor including surge counter/monitors, insulating base and all associated accessories, auxiliaries complete in all respects.
Circuit breaker (33 KV Voltage level)
33KV VCB (36KV,1250A of 3phase,50c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries along with supporting structure etc complete in all respects universal spring charging motor along with mandatory spares like 1 set of closing & tripping coils, antipumping relay etc.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .