Tender Value
₹71.1 L
EMD Value
₹1.4 L
Closing Date
16 Jun 2023, 9:00 amClosed
Xen,Kandi Canal Stage2 Division,hoshiarpur
Xen,Kandi Canal Stage2 Division,hoshiarpur
Repair of Electrical and Sub 200HP, Seals etc. of Pojewal lift Irrigation scheme-I off taking at RD 2150m of Pojewal rising main off-taking at RD 112526 m of Kandi Canal Stage-2.
2023_WR_103530_1
03
Open Tender
Electrical Works
Item Rate
120 days
Pojewal
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹1.4 L
Yes
14 Jul 2023
2 Jun 2023
16 Jun 2023
2 Jun 2023
16 Jun 2023
2 Jun 2023
Amount
Repair & Replacement of MINOR COMPONENTS incluiding dehydration, chemical cleaning, X- terminator along with labour work for taking out springs mechanisms of VCB and replacing with new components to make 11kV vacuum circuit breaker operationalized consisting of 1250Amp. Drawout type panel for incoming 110 VDC operative control wiring, for ON/OFF TRIP/TRIP CKT Healthy, spring charged, R,Y,B Phase Indicators, .TP IDMTL microprocessor based relay having 3 overcurrent elements & one earth fault element, . instantaneous under voltage relays reset table between ,breaker control switch,control fuses, insulator,cable termination for power cable gland for control cable, control wiring etc. (SEEREX PUMPS PVT. LTD.)
Repair & Replacement of MINOR COMPONENTS incluiding dehydration, chemical cleaning, X- terminator along with labour work on 2000kVA ,3 Phase,4 wire,50 cycle, transformer replacing of breather, transformer oil dehydration, top up of transformer oil level, outdoor type, naturally self cooled 11kV/.433kV.OFF LOAD TAP CHANGER.and tested to comply with National and International Standards-BIS-2026/IEC-76/BS-171 etc. Out door type.HV /LV both end cable box etc. (SEEREX PUMPS PVT. LTD.)
Supplying of HT VCB Terminals indoor- upto 120 sqmm Make: ISI marked
Supplying of HT TRF. Terminals outdoor - upto 120sqmm Make: ISI marked
Labour work for testing all types of existing damaged HT /LT cables from Main starter Panel to TRF /D.G set and TRF to VCB with high voltage and low voltage magger values and earth testing for any leakages and removing defects by replacing the defective part and making new joints , glands, thinmbles etc for making it same as for operational use ( labour work only )
Providing of Cable Connection outgoing and Incoming terminals of the Alu and copper thimbles etc complete in all respect.
Supplying of 400 sqmm 3.5 core Aluminium cable armoured grade cables conductor,PVC/XLPE insulated aluminium conductor armoured,extruded outer PVC sheathed 1100V,grade cables. Make : Indian Cable CCI / Universal cables / ICL / Havells. /Polycab
Supplying of 2.5 sqmm 3 core copper cable armoured in PVC rigid flexible cable Make : Havells /Polycab
Providing and Fixing of flat Submersible 3 core copper conductor cable confirming to IS:694 flexible 1100 V size 70 sq.mm Make B.C.H/ L&T/Finolex/Havells/Polycab/KEI
Supply & laying of GI earthing strip 50 mm x 6mm and earthing Cable inside pump chamber for earthing.
Repair & Replacement of minor components inculding dehydration,cleaning taking out softstarters fixing in main panel for operationlize for use of repcaking of terminations of control wiring replacement of defective components and re-programming 200 HP SOFT STARTER; 400A , MCCB with Adjustable overload protection soft starter 200 HP 3-wire suitable for inline connection with LCD display for precise motor start, stop, monitor, control and protection having adjustable settings like initial voltage output between 30-70% of the nominal voltage, Soft starter must have integrated motor and load protection features like overload protection with dual overload class settings, high current protection, locked rotor protection, under load protection and torque control feature
Replacement of new 200 HP SOFT STARTER; Adjustable overload protection soft starter 200 HP 3-wire suitable for inline connection with LCD display for precise motor start, stop, monitor, control and protection having adjustable settings like initial voltage output between 30-70% of the nominal voltage, Dual current limit between 200% and 500% of the soft starter's rated full load current with timer, adjustable Ramp in and ramp out time, kick start etc. Soft starter must have integrated motor and load protection features like overload protection with dual overload class settings, high current protection, locked rotor protection, under load protection and torque control feature for precise pump control compateable with SCADA and PLC Make of softstarters- ABB/Schnider/Seimens
Repair & standard Service of Existing Connected 500 KVR DG Make kirloskar
Replacement of missing parts of dg set such Battery 2 Nos. 12 V 180 AH Maintenance free with leads • Brushless self starter- Self-excited, self-regulated Class ‘H’ insulation limited to temperature rise of class H • Automatic voltage regulator repair
Providing and fixing of HT panel battery bank and battery charger 24 VOLT DC supply capacity for 1250 Amb VCB safety protection, metering, annunciation, charger cabinet, wiring etc complete in all respect as per site requirement
Supply and Fixing of Single monorail along with chain pulley block lift of 10 mtr capacity of 3 ton span on existing MS structure and welding at site along with repairing oiling and greasing in all respect to make unity in running condition.
Repair and rewinding of existing VERTICAL SUBMERSIBLE POLDER TYPE PUMPS 200 HP along with lifting shipping to workshop and back lowering to site including making of water proof cable joints from inside of pump casing and changing of lubricants and replacement of defective parts if any inside the pump like Bushes, wear rings, bush sleeves and thrust plate and bearings, carter couplings and mechanical seal complete in all respects
Supply & laying of shock proof HT rubber matting for control panel room in 2 SQM sheet as per site requirement
Rent of Diesel Gen set including cost of diesel etc.complete in all respects for execution of work for reparing at site
Repairing including providing of MS ladders, framed grills, gratings, iron doors, windows shutter repairs, and gate repair panels room etc. including cost of fixing and grouting complete re fixing in position
Any other item
MITTAL CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .