CHIEF ENGINEER COAST GUARD GOA
CHIEF ENGINEER COAST GUARD GOA 403806
ADDITION/ ALTERATION AND SPECIAL REPAIRS TO HANGARS WITH ALLIED BUILDINGS AT DAMAN
2026_MES_769555_1
84062/E8
Open Tender
Civil Works
720 days
DAMAN
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹3,000
GE DAMAN
₹7.3 L
Yes
3 Jun 2026
3 Jun 2026
9 Jul 2026
3 Jun 2026
2 Jul 2026
25 Jun 2026
REPAIR & RETROFITTING WORKS
Injection Grouting: M & L for providing and applying grout made of cement slurry mixed with non-shrink additive like MasterFlow 150 of BASF / Cebex 100 of Fosroc / Intraplast Ep of Sika or equivalent by injection grouting under pressure through nozzles provided, into cracks/ honeycombed areas by using suitable grouting pump till refusal including all tools and tackles, transportation, supervision etc, complete all as specified and directed.
M & L for cleaning rusted reinforcement bars by tapping or using mechanical wire brush or any other suitable way including from all around the reinforcement bars to give it a totally rust free finished steel surface complete all as specified and directed. Note: Mode of measurement - Flat surface area of exposed reinforcement.
M & L for supplying and providing one component, polymer modifed, cementitious anti-corrosive primer, formulated to provide dual protection of a polymeric barrier and an integral corrosion-inhibiting system, to the existing steel and additional steel provided before patching of damaged areas, using suitable tools and equipment, all as per manufacturer's instructions complete all as specified and directed. Make: BASF MasterEmaco P130 / Fosroc Nitoprime Zincrich / Sika Rustoff 100 or other equivalent. Note: Mode of measurement - Flat surface area of exposed reinforcement.
M & L for repairing damaged concrete portion with single component, fibre reinforced, dual shrinkage-compensated, thixotropic, cementitious patch repair mortar, applying 25mm thick mortar in single layer initially by hand and finishing with trowel, carefully compacting the mortar around the rebars and finishing to bring it in line with existing concrete surface with an average thickness of 25mm using suitable tools and equipment, all as per manufacturer's instructions complete all as specified and directed. Make: MasterEmaco S348 of BASF / Renderoc HB-60 of Fosroc / Sikadur 41 of Sika or equivalent.
M & L for repairing damaged concrete portion with single component, fibre reinforced, dual shrinkage-compensated, thixotropic, cementitious patch repair mortar, applying total 50 mm thick mortar in two layers, initially by hand and finishing with trowel, carefully compacting the mortar around the rebars and finishing to bring it in line with existing concrete surface with an average thickness of 50mm using suitable tools and equipment, all as per manufacturer's instructions complete all as specified and directed. Make: MasterEmaco S348 of BASF / Renderoc HB-60 of Fosroc / Sikadur 41 of Sika or equivalent.
M & L for providing mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as steel reinforcement for RCC work including straightening, cutting, bending, placing in position arid binding above plinth level complete all as specified and directed.
M & L for repairing damaged concrete portion with single component, fibre reinforced, dual shrinkage-compensated, thixotropic, cementitious patch repair mortar, applying in thickness more than 50 mm upto 60mm, in two or more layers, initially by hand and finishing with trowel, carefully compacting the mortar around the rebars and finishing to bring it in line with existing concrete surface with an average thickness morethan 50mm, upto 60mm using suitable tools and equipment, all as per manufacturer's instructions complete all as specified and directed. Make: MasterEmaco S348 of BASF / Renderoc HB-60 of Fosroc / Sikadur 41 of Sika or equivalent.
STRUCTURAL STEEL REPAIRS IN DOORS & TRUSSES
Dismantling aluminium bird proofing jalli of any size and refixing after completion of all repairs including making way for serviceable cable, pipe line, including minor repairs, cleaning other connected items complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F structural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde E-250) Quality `A' complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
PERIODICALS
M & L for preparation of old painted steel surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted steel surfaces n.exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted wooden surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old decorated wall surfaces and applying two coats of white wash complete all as specified and directed.
M & L for preparation of old decorated ceiling surfaces and applying two coats of white wash complete all as specified and directed.
M & L for preparation of old decorated plastered or unplastered wall surfaces and applying one coat of oil bound distemper white or tinted including filling of the holes/cracks with wall care putty and finished as required complete all as specified and directed.
M & L for preparation of old treated surface of wall, chajja, parapet etc and applying one coat of Acrylic smooth exterior paint of required shade @ 0.9 ltr/10 sqm as required complete all as specified and directed.
ROOF / ROOF DRAINAGE SYSTEM, CLADDING TO HANGAR DOORS
M & L for providing pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, as in hangar door /cladding to wall, height n.exc 15m, fixed with self tapping screws including dismantling old sheeting complete all as specified and directed.
M & L for providing pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, as in hangar door / cladding to wall, height n.exc 15m, fixed with self tapping screws including dismantling old sheeting complete all as specified and directed.
JOINERY
Taking down door/ window shutter with frame (without taking off shutters from frame) of any description exc. 1.50 Sqm but not exc 4.00 Sqm each etc complete all as specified and as direted.
S & F factory made uPVC door frame made of uPVC extruded sections having an overall dimension (extruded section profile) 42 x 50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded, hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge.
M & L for provision of toughned glass as in hinged doors, automatic doors and similar work including cutting to shape, drilling holes as required (12mm thick) complete all as specified and directed.
Taking down door/ window/ ventilator shutter with frame (without taking off shutters from frame) of any description n.exc. 1.50 Sqm each etc complete all as specified and directed.
Refixing door/ window shutter with frame (without taking off shutters from frame) of any description n.exc. 1.50 Sqm each in same opening complete all as specified and directed.
Refixing door/ window shutter with frame (without taking off shutters from frame) of any description exc. 1.50 Sqm but n.exc. 4.00 each in same opening complete all as specified and directed.
Providing and fixing factory made uPVC white colour Sliding window three track, area not exceeding 2.00 sqm each, made of extruded profiles with wall thickness of 2.3mm ( ± 0.2mm). window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding mesh sash (42mm x 57mm) sliding interlock (one vertical length in each shutters) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware; EPDM gasket, 1.2 ± 0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners; Hardware incl Touch Lock of zinc alloyed (white powder coated), steel roller system. stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. Notes: 1. The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. 2. Net opening will be measured for payment purpose.
Providing and fixing factory made uPVC white colour Sliding window three track, area exceeding 2.00 sqm each, made of extruded profiles with wall thickness of 2.3mm ( ± 0.2mm). window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding mesh sash (42mm x 57mm) sliding interlock (one vertical length in each shutters) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware; EPDM gasket, 1.2 ± 0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners; Hardware incl Touch Lock of zinc alloyed (white powder coated), steel roller system. stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. Notes: 1. The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. 2. Net opening will be measured for payment purpose.
S & F aluminium powder coated frame (minimum thickness of powder coating 50 micron) in any position such as door, window & ventiator frame, grills, guard bars etc members made out of extruded Aluminium of any section and in any position including fixing clips and provision of roller for fixing of prelaminated particle board, roller and roller plate for fixing of shower cubicles complete all as specified and directed. Make of aluminium section - Jindal/ Indalco/ Hindalco or equivalent.
S & F powder coated aluminium door shutters (thickness of powder coating not less than 50 micron)., aluminium sections weighing 0.55 kg/m, handles 2 Nos in each door, SS hinges 100mm size 03 Nos including, rubber gasket, PVC wheel with ball bearing, concealed type lock and fixing of glass complete all as specified and directed. Make of aluminium section - Jindal/ Indalco/ Hindalco or equivalent. Note: (i) The measurement shall be recorded weight of aluminium section only and rate quoted shall be deemed to be inclusive of rubber gasket, rubber beading, PVC wheel with ball bearing, concealed type locks, handle etc (ii) Glass and steel wire cloth shall be measured and paid separately as supply only.
S & F powder coated aluminium side hung type without sash bars/ sliding window and ventilator shutters, aluminium sections weighing 0.55 kg/m, including, rubber gasket, PVC wheel with ball bearing, concealed type lock and fixing of glass complete all as specified and directed. Make of aluminium section - Jindal/ Indalco/ Hindalco or equivalent. Note: (i) The measurement shall be recorded weight of aluminium section only and rate quoted shall be deemed to be inclusive of rubber gasket, rubber beading, PVC wheel with ball bearing, concealed type locks, handle etc (ii) Glass and steel wire cloth shall be measured and paid separately as supply only.
S & F solar controlled film, 50 micron, reflective type stuck to glass as per instructions of manufacturers complete all as specified and directed.
S & F aluminium anodised XPM grill aluminium alloy DG 202 grill 4.8 mm thick (in the shape of expanded metal of aluminium XPM jalli) opening size 59mm (length expansion) and 45 mm (width expansion) fixed in and including E/H frame, as bird proofing jalli below trusses all as per manufacturers instruction complete all as specified and directed.
S & F aluminium (extruded section) body door closer, hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 60 to 80 Kgs complete all as specified and directed.
M & L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of mild steel heavy duty and fixed complete all as specified and directed.
S & F mortice lock vertical type of brass of size 100mm 4 lever fixed to aluminium door with complete fittings etc complete all as specified and directed.
M & L for moulded polyethylene water storage tanks 1000 Lts (cylindrical vertical with closed top) hoisted and fixed in position all as specified including dismantling water tanks capacity exc 1000 ltr but not exc 2000 ltrs and removing to store complete all as specified and directed.
ALLIED BUILDINGS
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons, counter etc laid, bedded and pointed in any cement mortar complete all as specified and directed.
M & L for providing acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors and walls complete all as specified and directed.
Demolition of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as direted.
S & F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
M & L for providing 12 mm thick mineral fibre insulation board/tiles, ordinary type, of size 595 x 595 mm and fixed to timber frame work with nails complete all as specified and directed. (Make - Armstrong or equivalent )
M & L for providing 12mm seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seamless finish complete all as specified and directed. Note: Frame work for ceiling shall be measured and paid separately under relevant item of this schedule.
M & L providing Granite (of any type) work (table rubbed and polished) In steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for rounding to edges of stone slabs one edge, such as in steps, columns, cooking platform, window cills and other similar situations complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, at any description laid dry complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
Demolition of concrete in ground floors and pavings n exc 15cm thickness at any description (below or above ground level) complete all as specified and directed.
M & L for providing PCC (1:3:6) type C1 (using 20 mm graded aggregate) 75mm thick as in plinth protection etc complete all as specified and directed.
S & F vitrified dark shade/double charged/ultracharged tiles of 10 mm thick (square / rectangular) area of each tiles exc 0.42 sqm but not exc 1.00 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured to match coloured tiles, laid over 20 mm screed bedding in CM (1:6) and 20mm thick PCC 1:2:4 type B0 using 12.5mm aggrgate graded flooring below screed complete all as specified and directed.
S & F vitrified dark shade/double charged/ultracharged tiles of 10 mm thick (square / rectangular) area of each tiles exc 0.42 sqm but not exc 1.00 sqm as in skirting / dados etc set and jointed in neat cement slurry and pointed in white or coloured to match coloured tiles including rendering 10 mm thick in CM (1:3) complete all as specified and directed.
S & F non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm matt finish as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles, laid over 15 mm thick screed in CM (1:4) and 20mm thick PCC 1:2:4 type B0 12.5 aggrgate graded flooring below screed complete all as specified and directed.
S & F glazed ceramic coloured tiles 600 x 350 x 7mm thick on vertical surfaces such as skirting / dados set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles including rendering 10 mm thick in CM (1:3) as in backing coat complete all as specified and directed.
Taking down cement plaster of any description from walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water etc. removal of rubbish off the premises and removal of debris outside from MD land etc complete all as specified and directed.
M & L for rendering 10mm thick in CM (1:6) internal plaster on brick/concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
M & L for rendering 15mm thick in CM (1:4) in two coats (10 mm first coat + 5mm finishing coat) on brick/ concrete surfaces with water proofing compound @ 3% by weight of cement in finishing coat and surfaces finished even and smooth without using extra cement etc complete all as specified and directed. Note:- WPC shall be measured and paid seperately under relevant item of the schedule.
M & L for rendering 5 mm thick on fair faces of brick or concrete surfaces of ceilings in CM (1:3), finished even and smooth without using extra cement complete all as specified and directed.
Supply only Integral waterproofing compound complete all as specified and directed.
M & L for preparation of newly plastered surfaces and applying two coats of oil bound distemper paint on walls over a coat of alkali resistant primer etc complete all as specified and directed.
M & L for preparation of newly plastered surface of wall, chajja, parapet etc and applying two coats of acrylic emulsion paint, two or more coat applied @ 1.67 ltr/10 sqm over including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specidied and directed.
M&L for preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer etc complete all as specified and directed.
S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought framed, rebated on the solid, single or double rebate rounded or chamfered, put together with glue pinned at joints etc complete all as specified and directed.
M & L for providing 18mm thick veneered decorative plywood, in repairs, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with screws to timber frame work complete all as specified and directed.
M & L for providing 12mm thick veneered decorative plywood, in repairs, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with screws to timber frame work complete all as specified and directed.
M & L for providing second class hardwood plain fillets, square /rectanguliar wrought sectional area exc 13 and n exc 25 sqcm and secured with screws etc complete all as specified and directed.
M & L for providing 6 mm thick teak wood lipping fixed with nails etc complete all as specified and directed.
M & L for providing 0.9 mm thick decorative laminate type I of surface finish, colour and pattern as approved, fixed with approved adhesive all as per makers instructions complete all as specified and directed.
M & L for providing french polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats etc complete all as specified and directed.
S & F in repairs continuous (piano) hinges, mlid steel, bright finish or electrogalvanised, 40 mm wide flaps (when open), to chowkat/ window frame/ cupboard complete all as specified and directed.
S & F 125 mm size brass handles cast type polished bright complete all as specified and directed.
S & F magnetic catcher of approved size and pattern fixed to shutters etc complete all as specified and directed.
S & F brass 4 lever cupboard lock 75mm size of approved type and pattern etc complete all as specified and directed.
S & F 100mm size hasp and staple, safety type, brass with aluminium anodised hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed.
S & F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelaminated PVC sheet and edges painted to match with prelaminated sheet, reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S & F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelamiated PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S & F 125 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-22 complete all as specified and directed.
S & F 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S & F 150mm size aluminium handles, cast type, anodised complete all as specified and directed.
Taking up or down 15 mm bore dia steel tubing and connecions fixed to walls or laid in floors/ trenches etc complete all as specified and directed.
Taking up or down 20 mm bore dia steel tubing and connecions fixed to walls or laid in floors/ trenches etc complete all as specified and directed.
Supplying and laying CPVC pipes SDR 11 & plain CPVC SDR 11 fittings of external dia 16mm on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and laying CPVC pipes SDR 11 & plain CPVC SDR 11 fittings of external dia 20mm on walls/ceiling or laying in floors complete all as specified.
S & F in repairs bib taps chromium plated fancy type with capstan head, with flange, screwed down, screwed for iron pipe or for brass ferrule 15mm bore, complete at any position all as specified and directed.
M & L for providing vitreous China coupled WC, with UF soft close seat cover, hinges, accessories set, size 660 x 380 x 770, 180mm P-trap, dual flush cistern and all cistern fittings, all accessories including taking down old WC and flushing cistern complete all as specified and directed. Make: Jaquar Cat Part No LYS-WHT-38751 P (for WC) and LYS-WHT-38201C (for cistern) or equivalent.
M & L for providing WHB, counter type, size 350 x 450 x 165mm including taking down old WHB complete all as specified and directed. Make-Jaquar Cat No CNS-WHT-803 or equivalent
S & F in repairs vitreous china, 1st quality urinal half stall type, white, with and including brass chromium plated flush pin, 40mm dia brass CP waste coupling, 40mm dia HDPE waste pipe with all other necessary fittings etc complete all as specified and directed.
S & F in repairs health faucet with 1 meter long CP flexible tube & hook and all necessary fittings complete all as specified and directed.
S & F in repairs 2 way CP Bib cock, double handle with flange and all necessary fittings complete all as specified and directed.
S & F in repairs pillar tap cast copper alloy with capstan head, fancy type, chromium plated screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe & fixed, of 15 mm dia, suitable for WHB complete all as specified and directed.
S & F in repairs 15 mm size stop valves fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends etc complete all as specified and directed.
S & F in repairs soap dish of PTMT any colour fixed with and including CP brass screws and wooden/plastic cleats complete all as specified and directed
M & L for providing tubular towel rail, brass, chromium plated, 20mm dia inlcuding taking down old towel rail complete all as specified and directed. Make: Jaquar or equivalent
S & F towel ring of long PTMT fixed with and including chromium plated brass screwes and wooden/plastic cleats (minimum weight 90gms) inlcuding taking down old complete all as specified and directed
S & F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 3330mm x 160mm complete all as specified and directed.
S & F in repairs CI floor/nahani trap 75mm dia with grating, incl jointing to waste pipe in run lead and making good the disturbed surface to match existing surface complete all as specified and directed.
Demolition & breaking up drain pipes upto 110/75 mm dia (salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed.
M & L for providing PVC (SWR) pipe, 110 mm dia, double socketed in any length with solvent cement, fixed to walls including connecting to making hole and connecting to valley gutter complete all as specified and directed.
M & L for providing PVC (SWR) bends, 110mm dia, any radius, with solvent cement complete all as specified and directed.
HANGAR FLOORING
M & L for providing cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed.
Supplying and applying of a four component pre-measured pack for self-smoothening, pigmented, UV stable, 1000 micron thick, rapid curing, Polyaspartic flooring material like Spartikote SL of Dr Cipy or equivalent products having tensile strength > 12 MPa as per ASTM D 638, elonagtion > 2% as per ASTM D 638, abrasion resistance of 37 mg loss as per ASTM D 4060 by CS, 17 wheel 1000 cycles, flexural strength ≥13 MPa as per ASTM D 790; Pull of Adhesion test ≥ 2 MPa for M20 grade concrete as per ASTM D 4541; Hardness, Shore D: ≥ 80 as per ASTM D 2240 and impact resistance of 9.81 Joule as ASTM D 2794, scratch resistance upto 4kg pass as per IS 101, Slip resistance upto 56 PVT as per EN 13036, UV stable as per ASTM D 4329 and average dry film thickness of topcoat about 1000 microns as per ASTM D 7091; flooring having hot tyre pickup resistance and applied over a solvent free epoxy-based primer coat like CIPOXY 16 of Dr Cipy or equivalent products having bond strength more than 2MPa or as recommended by the manufacturer complete all as specified and directed. Make: Cipy/ Sika/ Bostic/ Fosroc with similar or superior specifications.
AUTOMATIC DOOR FOR HANGAR
Design, supply, install, testing, automatic door operation electromechanical system on hangar door at various locations, of sizes and leaves as mentioned below, complete all as specified and directed.
750 Sqn (Twin hangar). Size - 44 m x 12 m, 20 leaf, 10 leaf one side, another 10 leaf another side x 2 entry (both front and rear side) = 40 leaf.
841 Sqn hangar. Size - 18 m x16m (6 leaf), each leaf size = 3.2 m x 6 m.
AED/ ALD hangar Size - 32 m x 8m (8 leaf), bi-parting x 2 entry so total 16 leaf and each leaf of size 4m x 8 m.
The automation electromechanical system of hangar doors shall be designed and executed as per following specifications and specifications as given in Particular Specifications:-
(a) Electric Operation Outdoor type fully enclosed weather proof heavy duty 3 H.P 3-phase weather proof electric motor (there will be one Motor each for every 2 leaves i.e master and slave leaf), suitable/ capable to take load of each leaf. Each electromechanical Motor Gear Drive Unit shall include Idler Braking System, manual de-clutching system, motor foundation, fully enclosed weather protected control panel duly fitted with overload protection, MCCB, motor protection, emergency switch, and LED push button switch for forward Reverse-Stop Function, Festoon type cable carrier with rope wire arrangement, tightner, fire rated electric cable minimum 2.5 mm multicore from motor unit to control panel, other fire rated electric cable minimum 0.75 mm multicore for limit switches to control panel, cable fixing MS conducting with bends, clamps complete with nut bolt & other hardware. The door shall also include hooter cum blinker for safety of door, Idier assemblies, wire brush track cleaner at bottom in each leaf, heavy duty cleat to protect from de-railing, manual de-clutching arrangement in case of power failure; EPDM/ Neoprene Gasket-D & Flat Shape Gasket duly fixed with aluminium strip; flat 3 mm Neoprene soft rubber fixed at Edges of each leaf to cover gap between two leafs to protect inside hangar premises from rain & dust, heavy duty buffer stopper at extreme end of each side parking bay for each leaf for extra safety; anti-falling arrangement. The speed of Door shall be maintained at 6 to 7 meter per minute.
(b) Operation of Door System Each master door leaf shall have a separate traction drive operating unit driving one or more of the bottom wheels. Each Master leaf shall have a motor-mounted, spring-set, solenoid-released motor brake, Each Master leaf shall move with one slave leaf of the other leaves. The mode of operation/speed will be same at both ends. There should be no jerk in door during operation at any point.
(c) Operating Units Each operating unit shall move its master leaf at a speed of approximately to 6 to 7 meter per minute at a zero wind load conditions. The operating unit shall consist suitable 3-Phase bi-directional motor with speed reducer and other attachments all duly enclosed to protect from weather, high speed shaft idler brake, and necessary roller chains and sprockets.
(d) Auto cut limit switch There shall be auto-cut limit switch for each master leaf both at initial and final destination.
(e) Idler Braking System Braking systems shall be designed under normal, dry rail conditions within the safety edge over travel limit. The braking system shall be attached with motor mechanism. This prevents motor from direct transmission of master wheel which ultimately minimizes jerk caused due to start of motor. This also helps at the of closing of door at final destination.
(f) Outdoor Type Control Panel Each door master leaf shall have outdoor type control stations at each leading edge above the floor and from the edge, to avoid interference from the weather stripping, but still permit hand access when leaves are stacked in the open position. Stations shall be heavy-duty with constant switch hold down pressure, mushroom type push buttons, requiring a operator to walk each door leaf open or close while depressing the button. Controls shall be weather tight with convenient hand access when doors are stacked fully open. Control panel shall be of motor protection, overload, emergency power off, other safety features, LED switches with Forward-Reverse-Stop options. Each individual leaf shall have an individual surface mounted control station at each end, each side permitting individual door operation.
(g) Warning Devices (Hooter cum Flasher): Clearly audible signal shall be provided on each individually operated leaf. The warning device shall operate when the push button is actuated for movement of the door in either direction.
(h) Emergency Manual Operation Motorization of hangar doors, shall be constructed and equipped with a manual declutching twisting arrangement to be fixed at normal height so that they can be operated by on-site emergency power or manually.
(j) Auto Track Cleaner For automatic cleaning of bottom tracks from dust and small pieces, a hard nylon brush shall be provided at the bottom of each door leaves.
INTERNAL ELECTRIFICATION
Taking down carefully copper/aluminium point wiring (light,fan socket or power) point complete,including fixtures and fittings such as switches, ceiling rose, pendents, regulators, sockets, tube light fitting,main switch,MCB and DB's etc complete all as specified and directed.
M & L for point wiring using ISI marked 1.1 kV grade single core 1.5 Sqmm FR-LSH flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130-1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor (1.5 Sqmm), connecting to earth dolly, drawn in not less than 25 mm nominal bore PVC conduit with all conduit accessories concealed in wall, conforming to IS: 9537 (Part 3) -1983, colour-coded as specified in IS: 11353-1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772-2000 and including modular cover-plates as specified in IS: 732-1989 for the following complete all as specified and directed. Notes : (i) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping. (ii) Three run of 1.5 Sqmm wire and 01 run of PVC conduit shall be measured as one unit.
One light point controlled by one switch.
One fan point controlled by one switch.
One light point controlled by two way switch.
One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sqmm size
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board with cable 1.5 sqmm size
One 3 pin socket outlet, 5 Amps on the same board with other switches.
M & L for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm nominal bore PVC conduit with all conduit accessories concealed in wall, conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353-1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772-2000 and including modular cover-plates as specified in IS: 732-1989 for one 16 A socket outlet, independent, with cables three run of 4 sqmm size (phase, neutral & earth) complete all as specified and directed. Notes : (i) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping. (ii) Three run of 4 Sqmm wire and 01 run of PVC conduit shall be measured as one unit.
S & F modular type 6 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal complete all as specified and directed.
S & F modular type 6 A two-way SP switch, conforming to IS: 3854-1997 with finger proof terminal complete all as specified and directed.
S & F modular type 16 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal complete all as specified and directed.
S & F modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293-2005 complete all as specified and directed.
S & F modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293-2005 complete all as specified and directed.
S & F modular type bell push 6 Amps, 6 Pin combined 2 module complete all as specified and directed.
S & F bell, suitable for 230 V AC supply, single pole complete all as specified and directed.
S & F ceiling rose, 3 terminal, PVC polycarbonate body complete all as specified and directed.
S & F modular type fan regulator stepped type 120 W, 2 module complete all as specified and directed.
Taking down existing tube light fitting, ceiling light fitting of any type/make complete with all accessories complete all as specified and directed.
S & F LED 4' ft light fitting 1x22W, 220V, AC decorative box type with driver, including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED tube light (2 feet) along with fixture, 10 watts, 230 volts including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F LED flood light 200 watt 230 V AC outdoor type with cast aluminium housing, toughned glass cover, high power LEDs, secondary optical lenses, 10KV SPD, >100 lm/watt, with IP66 protection, impact and corrosion resistant, wired with all accessories complete all as specified and directed.
S & F in repairs integral LED aviation light complete with all accessories, prewired, aluminium housing with polycarbonate diffuser & cast aluminium housing IP-65, fixed on roof top/ hangar at any height by adopting saftey precautions complete all as specified and directed.
S & F telephone cable of size 0.5 mm, two pair type-solid annealed copper polythene insulated sheathed drawn through and including steel conduit medium grade with conduit accessories concealed in wall/ roofs/ floors/ beams/ columns etc and making connections on both sides complete all as specified and directed.
S & F telephone socket/ jack with shutter including pressed steel sunken box, concealed, flush mounting with 3 mm thick hylam sheet top cover complete all as specified and directed.
Taking down air circulator fan 600 mm sweep wall mounted/ pedestal type, of any make, from its existing position after disconnecting electric connections for carrying out repairs to oscillation and speed regulation mechanism including servicing, overhauling, winding, greasing etc after cleaning the body internally and externally with cleaning agent and replacement of spare parts, split pins, capacitor holder, nuts, bolts and washers, ball bearings, gun metal bushes, capacitor, rewinding of fan motor including fixing back in existing location and making cable connections and testing complete all as specified and directed.
S & F air circulator fans 230 volts, turbo force, single phase oscillating 600 mm sweep, 3 blades, 280 mm, 1380 RPM, suitable for wall mounting including mounting accessories complete all as specified and directed.
Supplying, installing, testing and commissioning, factory fabricated LT cubicle housing box, wall mounted type, made out of 2.00mm thick CRCA sheet, multifold design, chemically treated surface with multi seven tank process powder coating, indoor modular type, dust free, vermin proof, totally enclosed, confirming to IP 43, single door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 wire system, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embedded with iron angle frame complete with internal connection with suitable size of cable, cable lugs and cable glands and comprising of the following including removing existing old and unsv panel complete all as specified and and directed:-
(a) MCCB FP 63 Amps, 25 kA, Ics=Icu, thermal magnetic type (Incomer) (b) Industrial Wall/ Panel mounted plug socket suitable for IP67 degree of protection 32 Amps 5 pin, 3 phase + neutral + earth (for 415/420 V 3 phase) - 01 No (c) Industrial wall/ panel mounted plug socket suitable for IP67 degree of protection 32 Amps 3 pin, single phase + neutral + earth (for 240 V 1 phase) - 01 No (d) Industrial wall/ panel mounted plug socket suitable for IP67 degree of protection 16 Amps 3 pin, single phase + neutral + earth (for 240 V 1 phase) - 01 No
S & F in repairs triple pole and neutral, sheet steel enclosure complete with 3 pin and earth plug and socket including MCB FP 63 Amps, 10 kA 'C 'series, 415 volts complete all as specified and directed.
S & F in repairs triple pole and neutral, sheet steel enclosure complete with 3 pin and earth plug and socket including MCB SP 20 Amps, 10 kA 'C 'series, 240 volts complete all as specified and directed.
S & F sheet metal enclosure VTPN DB 6 Way, 8+18 modules, vertical type with 150 Amps rated bus bar, 415 volts, double door with magnetic locking system including necessary provision for inserting FP RCCB / RCBO / Isolator / MCB as incomer and fixing the DBs in wall by cutting the brick/ stone masonary etc and making good distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F sheet metal enclosure VTPN DB 4 Way, vertical type with 250 Amps rated bus bar, 415 volts, double door with magnetic locking system including necessary provision for inserting 125 Amp FP MCCB as incomer and fixing the DBs in wall by cutting the brick/stone masonary etc and making good distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F sheet metal enclosure VTPN DB 8 Way, vertical type with 250 Amps rated bus bar, 415 volts, double door with magnetic locking system including necessary provision for inserting 160 Amp FP MCCB as incomer and fixing the DBs in wall by cutting the brick/stone masonary etc and making good distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F triple pole & neutral, double door, 12-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set & cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
S & F triple pole & neutral, double door, 8-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set & cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
S & F triple pole & neutral, double door, 6-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set & cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
S & F triple pole & neutral, double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set & cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
S & F in repairs sheet metal enclosure MCB SPN DB 8 Way, 240 volts, double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F in repairs sheet metal enclosure MCB SPN DB 12 Way, 240 volts, double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F MCCB 4 Pole, 415 V, 320/ 350 Amps with breaking capacity 36 kA, Ics=Icu, thermal magnetic adjustable type complete all as specified and directed.
S & F MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 kA, Ics=Icu, thermal magnetic adjustable type complete all as specified and directed.
S & F MCCB 4 Pole, 415 V, 125 Amps with breaking capacity 25 kA, Ics=Icu, thermal magnetic adjustable type complete all as specified and directed.
S & F ISI marked RCBO FP 63 A, 30 mA, 440 V 4 Pole for AC applications, conforming to IS 12640 (Part-2) - 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed.
S & F ISI marked RCBO FP 40 A, 30 mA, 440 V 4 Pole for AC applications, conforming to IS 12640 (Part-2) - 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed.
S & F miniature circuit breaker (MCB) of following poles and current carrying capacity suitable for 240V; 10kA 'C' curve, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
SP 6 to 32 A
S & F MCB TP 63 A, 415V 10 kA 'C' curve miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning complete all as specified and directed.
S & F MCB TP 40 A, 415V 10 kA 'C' curve miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning complete all as specified and directed.
Supplying, instaling and testing exhaust fans, 54 inch with louvers, metal body, industrial type, hammer with copper winding, 2300 RPM, 6 blade, 220 Volt complete all as specified and directed.
Taking out window/split type AC of capacity 1.5/2.0TR, opening of the same and carrying out necessary repair and replacement of unserviceable spare/parts as required to make it operational, reassembling, gas charging etc and refixing the unit to its position complete all as specified and directed. Note:- (a) The labour cost for replacement of spares/parts shall be deemed to be included in this item. (b) The rates shall be inclusive of transport from the site to workshop and vice versa before and after the repair.
Taking down ceiling fan/ exhaust fan of any sweep and type after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades complete all as specified and directed.
M & L for refixing the celing fan/ exhaust fan obtained from item No 162 above after replacing unsv 3 core PVC insulated PVC sheathed 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including rewinding, over hauling the fan, painting of fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and directed.
S & F ceiling fans (with remote control) with BLDC motor including electronic type regulator and accessories 230 Volts, 1200 mm sweep BEE 5 star rated complete all as specified and directed.
S & F down rod made of 15mm dia MS pipe medium grade, 60cm long, with pre-drilled holes at both ends & slot with hole in other end, suitable for fixing ceiling fan complete all as specified and directed.
M & L for providing submain wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694 - 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130 - 1984 and insulation conforming to IS: 5831 - 1984, for phase, neutral and earth continuity conductor as specified below, connecting to earth dolly, drawn in not less than 25 mm nominal bore stove enamelled rigid steel conduits, with all conduit accessories concealed in wall etc conforming to IS: 9537 (Part 3) - 1983, colour-coded as specified in IS: 11353 - 1985, complete all as specified in IS: 732 - 1989 complete all as specified and directed. Note: (i) 03 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of steel conduit shall be measured as unit length. (ii) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping.
4 x 6 mm² + 1 x 6 mm² earth wire
4 x 10 mm² + 1 x 10 mm² earth wire
M & L for providing submain wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694 - 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130 - 1984 and insulation conforming to IS: 5831 - 1984, for phase, neutral and earth continuity conductor as specified below, connecting to earth dolly, drawn in not less than 25 mm nominal bore stove enamelled rigid steel conduits, with all conduit accessories concealed in wall etc conforming to IS: 9537 (Part 3) - 1983, colour-coded as specified in IS: 11353 - 1985, complete all as specified in IS: 732 - 1989 complete all as specified and directed. Note: (i) 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of steel conduit shall be measured as one length. (ii) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping.
2 x 2.5 mm² + 1 x 2.5 mm² earth wire One light/ fan point controlled by MCB 6 Amps Note: (i) 3 to 4 light point controlled by one MCB SP 6 A, MCB will be measured & paid seperately under relevant item. (ii) 2 nos fan point controlled by one MCB SP 6 A, MCB will be measured & paid seperately under relevant item.
2 x 4.0 mm² + 1 x 4.0 mm² earth wire
M & L for providing submain wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694 - 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130 - 1984 and insulation conforming to IS: 5831 - 1984, for phase, neutral and earth continuity conductor as specified below, connecting to earth dolly, drawn in not less than 25 mm nominal bore PVC conduits, with all conduit accessories concealed in wall etc conforming to IS: 9537 (Part 3) - 1983, colour-coded as specified in IS: 11353 - 1985, complete all as specified in IS: 732 - 1989 complete all as specified and directed. Note: (i) 03 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC conduit shall be measured as unit length. (ii) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping.
4 x 6 mm² + 1 x 6 mm² earth wire
4 x 10 mm² + 1 x 10 mm² earth wire
4 x 16 mm² + 1 x 16 mm² earth wire
M & L for providing submain wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694 - 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130 - 1984 and insulation conforming to IS: 5831 - 1984, for phase, neutral and earth continuity conductor as specified below, connecting to earth dolly, drawn in not less than 25 mm nominal bore PVC conduits, with all conduit accessories concealed in wall etc conforming to IS: 9537 (Part 3) - 1983, colour-coded as specified in IS: 11353 - 1985, complete all as specified in IS: 732 - 1989 complete all as specified and directed. Note: (i) 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC conduit shall be measured as one length. (ii) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping.
2 x 4.0 mm² + 1 x 4.0 mm² earth wire
2 x 6.0 mm² + 1 x 6.0 mm² earth wire
S & F cable tray made out of galvanised perforated sheet in 14 gauge,100 mm width & 50mm height including accessories like coupler, wall brackets up/down elbows, bend, tees etc., and fixing with FRP saddles in equal distances on wall crossing and making good to the surfaces as per direction complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point incl removing of existing old earthing including testing on completion complete all as specified and directed.
Supply and lay UG cable, XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) of size 3.5 Core 95 Sqmm, 1100V grade, with screened aluminium conductor including taking down old unserviceable cables complete all as specified and directed. Note: Excavation, cable protection etc shall be measured under relevant items of the schedule.
Excavation in trenches, not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layers n exc 25 cm complete all as specified and directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Demolition of cement concrete (unreinforced), in any position, exc. 15 cm below or above ground level and removing rubbish off premises min 500m away from bldg complex, complete all as specified and directed.
M & L for providing PCC 1:3:6 type C1 using 20 mm graded coarse aggregate for platform, mass concrete and coping including form work complete all as specified and directed.
M & L for providing PCC 1:4:8 type D2 using 40 mm graded coarse aggregate as in fondations, mass concrete complete all as specified and directed.
M & L for boring holes below roads, pavements, hard standing using trenchless technology using ultra sounding technique and necessary machine including providing DI pipe of 80 mm dia suitable for 0.4 MPa working pressure complete all as specified and directed.
Supply and laying DWC pipe, 80 mm outer diameter for laying under ground cables complete all as specified and directed
Supply and laying DWC pipe, 50 mm outer diameter for laying under ground cables complete all as specified and directed.
M & L for taking out old unserviceable HID (high intensity discharge) flash light with 12 Volt Lithium-ion battery and supplying and fixing of HID flash light, dual mode, portable, housing constructed of machined aerospace grade, aluminium alloy designed for rugged use, machined aluminium reflector, IP-68 water proof protection, dust & dirt proof, having 50 watt 4700 lumens, beam length 7000 feet beam and 35 watt 3500 lumens, beam length 5000 feet beam, continious operation of 110 minutes, overall weight 1.9 kg with one number 12 Volt Lithium-ion battery, facility of charging in 110 Volt to 220 Volts AC, omplete all as specified and directed. Make: Magna light, XENON or equivalent
FLAMEPROOF WIRING
M & L for point wiring using ISI marked 1.1 kV grade single core 1.5 Sqmm FR-LSH flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130-1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor (1.5 Sqmm), connecting to earth dolly, drawn in not less than 25 mm nominal bore steel conduit with all conduit accessories concealed in wall, conforming to IS: 9537 (Part 3) -1983, colour-coded as specified in IS: 11353-1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772-2000 and including modular cover-plates as specified in IS: 732-1989 for the following complete all as specified and directed. Notes : (i) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping. (ii) Three run of 1.5 Sqmm wire and 01 run of steel conduit shall be measured as one unit.
One light point controlled by one flame proof switch.
One ceiling/ exhaust/ wall mounted fan point controlled by one flame proof switch.
M & L for point wiring using ISI marked 1.1 kV grade single core 1.5 Sqmm FR-LSH flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors, conforming to IS: 8130-1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor (4.0 Sqmm), connecting to earth dolly, drawn in not less than 25 mm nominal bore steel conduit with all conduit accessories concealed in wall, conforming to IS: 9537 (Part 3) -1983, colour-coded as specified in IS: 11353-1985, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772-2000 and including modular cover-plates as specified in IS: 732-1989 for one socket outlet point 16 Amp controlled by one flame proof switch complete all as specified and directed. Notes : (i) Concealed wiring shall be done till ceiling height and there after on ceiling, wiring shall be done through PVC conduit/casing capping. (ii) Three run of 4.0 Sqmm wire and 01 run of steel conduit shall be measured as one unit.
S & F in repairs flame proof-weather proof switch socket with plug combination 3 pin, 16 Amps, 240 volts, 50 Hz made of pressure die cast aluminium alloy LM6 including making incoming and outgoing electric connections and necessary fixing arrangement complete all as specified and directed.
S & F in repairs flame proof-weather proof switch socket with plug combination 3 pin, 63 Amps, 400 volts, 50 Hz made of pressure die cast aluminium alloy LM6 including making incoming and outgoing electric connections and necessary fixing arrangement complete all as specified and directed.
S & F in repairs LED light fitting 1x16 Watt flame proof, CMRI certified, recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, including LED tube light fixtures driver, holders, connector etc., all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S & F flame proof-weather proof ceiling fan 1200 mm sweep, 240 volts, 50 Hz made of pressure die cast aluminium alloy LM6 including making incoming and outgoing electric connections and necessary fixing arrangement complete all as specified and directed.
S & F flame proof-weather proof exhaust fan,12 inch, 240 volts, 50 Hz made of pressure die cast aluminium alloy LM6 including making incoming and outgoing electric connections and necessary fixing arrangement complete all as specified and directed.
S & F switch, flame proof, rotary type, with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply and lay UG cable, XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) of following sizes, 1100V grade, with screened aluminium conductor including taking down old unserviceable cables complete all as specified and directed. Note: Cable protection shall be measured under relevant items of the schedule.
3.5 Core 240 Sqmm
3.5 Core 185 Sqmm
3.5 Core 120 Sqmm
3.5 Core 70 Sqmm
3.5 Core 50 Sqmm
Supplying, Installing, testing and commissioning factory fabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies, confirming to IEC 60349-1 & 2, LT feeder pillar box made out of 3.15 mm thick CRCA Sheet multifold design, chemically treated surface with multi tank process powder coating, indoor modular type, dust free, vermin proof, totally enclosed, confirming to IP 54 for indoor panel, single door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embedded with 50X50X6mm galvanised iron angle frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (using 20 mm graded stone aggregate) and testing after installation and comprising of following complete all as specified and directed. (hangar Panel, AED/ALD)
Supplying, Installing, testing and commissioning factory fabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies, confirming to IEC 60349-1 & 2, LT feeder pillar box made out of 3.15 mm thick CRCA sheet multifold design, chemically treated surface with multi tank process powder coating, indoor modular type, dust free, vermin proof, totally enclosed, confirming to IP 54 for indoor panel, single door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embedded with 50X50X6mm galvanised iron angle frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (using 20 mm graded stone aggregate) and testing after installation and comprising of following complete all as specified and directed. (hangar Panel, 750)
Supplying, Installing, testing and commissioning factory fabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies, confirming to IEC 60349-1 & 2, LT feeder pillar box made out of 3.15 mm thick CRCA sheet multifold design, chemically treated surface with multi tank process powder coating, indoor modular type, dust free, vermin proof, totally enclosed, confirming to IP 54 for indoor panel, single door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embedded with 50X50X6mm galvanised iron angle frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (using 20 mm graded stone aggregate) and testing after installation and comprising of following complete all as specified and directed. (hangar Panel, DTF)
Supplying, Installing, testing and commissioning factory fabricated LT panel board, type tested by CPRI /Authorised Govt. Agencies, confirming to IEC 60349-1 & 2, LT feeder pillar box made out of 3.15 mm thick CRCA sheet multifold design, chemically treated surface with multi tank process powder coating, indoor modular type, dust free, vermin proof, totally enclosed, confirming to IP 54 for indoor panel, single door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embedded with 50X50X6mm galvanised iron angle frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (using 20 mm graded stone aggregate) and testing after installation and comprising of following complete all as specified and directed. (hangar Panel RHS & LHS)
Taking down LT panel including all accessories after discconecting of all electrical connection including packing, bus bar, MCCBs, MCBs, voltmeter ammeter, indicators, nuts, bolts and washers; dismantling all parts and making good surface complete all as specified and directed.
S & F GI earthing strip 25 x 4 mm fixed to wall or recess or chases or buried in ground complete all as specified and directed.
Supply and lay GI pipe 50mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, tee etc laid in trenches/ duct/ culvert/ road crossing etc for protection of airfield lighting cable and electric cable including removing old unserviceable pipes complete all as specified and directed.
Supply and lay GI pipe 80mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, tee etc laid in trenches/ duct/ culvert/ road crossing etc for protection of airfield lighting cable and electric cable including removing old unserviceable pipes complete all as specified and directed.
FIRE FIGHTING
Supplying, installing, testing and commissioning beam master detector, motorized type, transceiver type, audible alarm, wall mounted, high sensititvity combined with fast response time to ensure rapid and accurate detection, multiple output option for maximum flexibility and compactibility, relays for detection, auxillary and fault; with fully adjustable swivel mounting base fixing at any height of hangar, compliance to NFPA 409 & NFPA 72, UL listed, including taking out old unserviceable detector complete all as specified and directed.
Supply, laying and connecting and testing of 1.5 sqmm, 2 core, 1100 volts, twisted pair, PVC insulated , FRLS, GI strip wire armoured, multistranded copper conductor GI wire armoured, cable confirming to IS standards and specification including medium grade, 25 mm dia, ISI marked conduit pipe including providing acrylic fire stop sealant in the opening where cables are passing through fire compartment wall of RCC, floors, masonary walls etc to provide upto 2 hrs fire rating taking out old unserviceable cable complete all as specified and directed.
Supplying, installing, testing and commissioning addressable electronic hooter cum strobe and connecting with fire cables including taking out old unserviceable hooter complete all as specified and directed.
Supplying, installing, testing and commissioning double action pull push type manual call point glass break system, housed in MS enclosure with mounting accessories including taking out old unserviceable manual call point complete all as specified and directed. Make: GE/ NOTIFIER/ EXFLAME/HONEYWELL
Supplying, installing, testing and commissioning main fire alarm control panel fabricated by MS sheet not less than 16 guage having MS sheet rear enclosure, ABS plastic front cover, addressable analogue fire detection and alarm type with capacity of 2 loops panel size not less than 391.5 x 390 x 145 mm of approximate weight 4.5 kg, suitable canopy 3 nos for mounting on wall to withstand 0 degree to 40 degree temperature, relative humidity 5% to 95%, non condencing IP 30 (BS EN 54) protection conforming to BSEN 54, comprisig to RS 232 communication port, req-signal port for foam generator, with DC power backup for 72 Hrs in standby mode and 15 min in alarm condition, 99 to 200 character display, each loop capacble of supporting analogue/ addressable devices for maximum system capacity and have TCP/IP facility and QWERTY keypad for programming, panel operating voltage of 230 volts AC (+ 15%, -15% ), 50 Hz PSU rating, 24 volt DC , 4A , standby batteries 2x17 AH duration 48 hrs with network card or repeater connected 24 hrs; auxillary output 24 Volt DC, 250mA fused including taking out old unserviceable fire alarm control panel complete all as specified and directed. Make: GE/HONEYWELL/BLUESTAR/EXFLAME .
S & F in repairs water foam sprinkler nozzle of 1/2 inch dia, BSPT threaded, made of brass and bronze, operating pressure 2.1 bar (30 psi) to 4.2 bar (60 psi), pendent type, having K factor K-42, approx discharge 61 LPM at 2.1 bar, complete all as specified and directed.
Supplying, installation and testing sprinkler rossette 25 mm dia at any height complete all as specified and directed.
S & F in repairs 63 mm dia 15m long hose pipe; externally elastomeric coated, all synthetic jacketted rubberised fabric, reinforced rubber lined (RRL), non-percolating, flexible fire fighting hose; resistant to liquids chemical abrasion & heat, having 38 kg/sqcm working pressure, bearing IS: 636 type "A" mark; fitted with gunmetal instantaneous pattern, heavy duty male & female hose coupling bearing IS:903 mark, bound by copper wire, with gun metal branch nozzle and necessary fittings complete all as specified and directed.
S & F in repairs first aid fire hose reel, wall mounted swivel type, fitted with 30 mtrs long 20mm dia, high pressured dunlop hose, confirming to IS:5132, with 15mm dia outlet branch nozzle, shut off valves as per IS 884 - 1969 including all necessary fitting items complete all as specified and directed.
S & F in repairs fire hose cabinet box of size 800 x 600 x 250 mm made of 18 gauge MS sheet for mounting of hose reel of size 63 mm dia and 15 mtr long and nozzle, with double leafed glazed shutters, door frame made of 16 guage MS sheet, painted fire red outside and brilliant white inside, with lettering as "FIRE HOSE", including locking arrangement, fixing by providing MS clamps, nut, bolts; incl branch pipe and nozzle, adaptor coupling etc as per site requirment complete all as specified and directed.
S & F in repairs fire hydrant landing valve, 63mm dia, gun metal, confirming to IS-5290 type 'A', instantaneous type, single headed outlet, with brass spindle, cast iron wheel coupling cap with chain etc, ISI marked, suitable for connecting hose pipe complete all as specified and directed.
S & F in repairs fire hydrant landing valve, 63mm dia, gun metal, confirming to IS-5290 type 'A', instantaneous type, double headed outlet, with brass spindle, cast iron wheel coupling cap with chain etc, ISI marked, suitable for connecting hose pipe complete all as specified and directed.
S & F in repairs solenoid valve, 24 V DC, brass body, operating pressure 0-150 Psi, IP-65, UL Listed, CE marked, corroson resistance, including necessary fittings and making connections complete all as specified and directed.
S & F in repairs butterfly valve, of following sizes, cast iron body, wafer type, ISI marked, confirming to IS- 13095, pressure rating PN 1.6, stainless steel SS 316 (CF8M) disc, single piece SS304 shaft, EPDM sleeve, luberized bushing, as per BS stranded lever operated type complete all as specified and directed. Note: Butterfly valve shall be fitted between two flanges on either side of pipe flanges. The valve edge rubber shall be projected outside such that they are welded with the pipe flanges to prevent leakages.
150 mm dia
100 mm dia
150 mm dia bore
100 mm dia bore
50 mm dia bore
25 mm dia bore
Supplying, installing, testing and commissioning deluge valve, differential diaphragm operated, auto reset type, can be easily actuated by manual, hydraulic, pneumatic and electic realse trim, can be mounted horizontally as well as vertically, UL listed, working pressure 20 to 300 Psi, suitable for mounting over 150/ 100 dia MS pipe including all fitting accessories i.e. actuator, ball valve, check valve, pressure gauge, Y-strainer, angle valve, water relay, drip valve; duly connected with MS tube including taking out old unserviceable valve complete all as specified and directed.
Supply, laying, connecting and testing cable, 1.5 sqmm 2 core, 1100 volts, twisted pair, PVC insulated, FRLS, GI strip wire armoured, multistranded copper conductor, GI wire armoured, confirming to IS standards and specification including 25 mm dia medium grade, ISI marked conduit pipe; providing acrylic fire stop sealant in the opening of cables passing through fire compartment walls of RCC, floors, masonary walls to provide upto 2 hrs fire rating including taking out old unserviceable cable complete all as specified and directed.
S & F in repairs pressure switches of suitable range (0.2 bar to 7.5 bar) for pump sets, with ball valve, including fittings like unions/ collars/ reducers etc and interlock with pump starter for automatic operation complete all as specified and directed.
S & F in repairs water flow switch 150 mm dia, to be fitted in sprinkler main distribution line to operate electrically operated alarm complete all as specified and directed.
S & F in repairs pressure gauge 100 mm dia, ball valve of pressure 0 to 21 Kg/Sqcm complete all as specified and directed.
S & F in repairs 25 mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.19 MB
84062TENDERPAGES.pdf
Tender Documents • 0.95 MB
84062PARTICULARSPECIFICATIONS.pdf
Tender Documents • 0.87 MB
BOQ_861804.xls
BOQ • 10.04 MB
Download all tender documents and submit your bid