Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹82.3 L+₹2.6 L (3.32%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹84.7 L+₹5.1 L (6.39%)Rejected-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹85.8 L+₹6.2 L (7.76%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹87.4 L+₹7.8 L (9.76%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
29 Jan 2020, 6:00 pmClosed
CWE NO 2
CWE NO 2 DELHI CANTT
SPL REPAIR TO BLDG NO P-84B (MNS OTM ACCN) AND T-24 (MNS OTM ACCN) AT BASE HOSPITAL UNDER GE (E/M) BASE HOSP, DELHI CANTT-10
2019_MES_308522_1
CWE/BH-30/2019-20
Open Tender
Civil Works
Item Rate
240 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (E/M) BASE HOSP
₹2.1 L
Yes
6 Mar 2020
21 Dec 2019
30 Jan 2020
21 Dec 2019
29 Jan 2020
18 Jan 2020
Amount
Taking down wooden roof trusses coupled rafter or trussed beam above 4.0 M and upto 8.0 M complete all as specified and directed.
Dismantling timber scantling in fillet, rail post, rafter, purline etc under 40 Sqcm in section in any position unframed work complete all as specified and directed.
Dismantling post & struts (wood, steel, RCC) any section including taking out embeded portion and making good disturbed ground post embeded in concrete complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layer not exc 25cm in soft/ loose soil including PCC complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (40mm graded agg) as in foundation, filling and mass concrete complete all as specified and directed.
S&F Steel work in tubular trusses/Posts/Rafters/Purlins, etc including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS- 1161-1998 gde St-240 complete all as specified and directed.
S & F plain MS plate including cutting / welding & drilling complete all as specified and directed.
Dismantling AC corrugated/semi-corrugated sheets in roof coverings including ridges complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specifed & directed.
M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding confirming to Fe-410 W(Gde-E-250) complete all as specifed & directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces width or girth exc 10cm including preperation of surfaces complete all as specified and directed.
Dismantling wall ceiling boards (Fibre pulp. Insulation, AC boards,wooden boards etc) or insulation boards/slabs/composite panel, etc any thickness complete all as specifed & directed.
M& L for GI anodised snap grid ceiling made of Tee and angle of size 24.5 x 24.5 x1.50 mm thick, size of grid 605 x 605 mm with GI wire suspender 2 to 3 mm dia fixed with wooden/steel truss/rafter flat or slope including taking down old ceiling complete all as specified and directed.
M&L for 4 mm thick E-board (designer)classic of size 595 x 595 mm, fixed to GI snap grid ceiling flat or slope complete all as specified and directed.
Demolition of brick work built in cement mortar of any description and including disposal of all debris complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in Cement Mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in Cement Mortar 1:4 complete all as specified and directed.
Dismantling brick tiles or terracing tiles, single layer on roof laid over mud pushaka and pointing with cement mortar complete all as specifed & directed.
Demolition of Mud in roofs, any thickness, including PCC/plastering and leeping complete and disposal of all debris distance exc 250Mtr not exc 500Mtr complete all as specifed & directed.
M&L for providing plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded stone agg) as in roof padding, Gola, etc including cleaning the surface by wire brushing complete all as specified and directed.
M&L for 20 mm thick rendering on concrete surface of roof with cement mortar 1:4 finished even and fair including mixing of water proofing compound as per manufacturers instruction complete all as specified and directed. (Note : Water proofing compound shall be measured and paid separately)
Supply only water proofing compound (powder) complete all as specifed & directed.
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 3.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end over laps & 10 cm side over laps etc as per manufacturers instruction. (c) M&L for finishing of top surface by a coat of aluminium paint complete all as specified and directed. Make: Ms Sika India Pvt Ltd/ Ms Fosroc chemicals/ Ms IWL India limited/ Ms Tiki Tar Danosa (India) Pvt Ltd/ Ms Torchtar Membrane & Bitumen Pvt Ltd.
Demolition of reinforcement cement concrete in ground floor and paving n exe 15cm thickness and any thickness below or above ground level disposal of all debris complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and paving exc 15cm thickness( below or above ground level) .including disposal of all debris complete all as specified and directed
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A1 using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A1 concrete using 20mm graded stone aggregate as in sunken slabs etc complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L Mild steel TMT bars 6mm to 8mm dia and over, cut to length bent to shape required including cranking bending,spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Form work to soffits of suspended slab such as roof slabs floor slab landing and similar work n.exc 200mm thick complete all as specified and directed
Demolition of unreinforced cement concrete in ground floors and paving not exc 15cm thickness( below or above ground level) including disposal of all debris and complete all as specified and directed
M&L 25 mm thick PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) below tiles for levelling of existing surface, mass concrete, etc complete all as specified and directed.
Supply and laying sand (25 to 30 mm thickness ) for cushioning to interlocking paver block complete all as specified and directed.
M&L for vibrator compacted rubber/glass moulded precast concrete interlocking paver block shape, size and colour as approved confirming to IS 15658-2006 of 60 mm thickness M-35 Grade made with grey cement and pigment complete all as specified and directed.
M&L for heavy duty coloured (approved colour) fully vitrified paving tiles of size 300mmx300mmx10-12mm thick, set and jointed in neat cement slurry and pointed in coloured or white cement to match the shade of tiles over and including 15 mm thick screed in Cement Mortar 1:6 complete all as specified and directed.
M&L for 75 mm PCC 1:3:6 type C-2 (40mm graded agg) as in plinth protection/hard standing and finished the surface even and smooth without using extra cement complete all as specified and directed.
Demolition of stone slabs laid bedded and pointed in any mortar and cladding tiles of any description or thickness in floors, aprons, walls, etc and removing the debris off MOD land complete all as specified and directed.
M&L 20 - 25 mm thick machine cut kota stone flooring laid over and including screed bed or bedding layer mortar 15mm thick in cement mortar 1:4 for laying floor finished jointed and pointed with grey cement slurry mixed with pigments to match the sheds including all grade rubbing and polishing upto mirror (polishing) image complete all as specified and directed.
All as per item No.40 here- in before but on skirting/dado including & over 10 mm thick rendering coat in cement mortar 1:3 complete all as specified and directed.
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in floors, steps, cooking platforms and like over and including 15 mm thick in cement screed mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of other than white and black including moulding, etc complete all as specified and directed.
M&L for 20 mm thick of approved shade granite stone (superior Quality) slab (table rubbed and polished as in floors, jambs,steps,cooking platform, etc and the like, over & including 15 mm thick screed in Cement Mortar 1:4 including pointed in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including two strip of line make of (stread of stair case) granite complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and including disposal of all debris exc 1.5 KM not exc 5 Km and complete all as specified and directed
M&L digitally printed double charged Vitrified ceramic tiles 1st quality 10mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed or bedding layer in Cement Mortar (1:4 )complete all as specified and directed by Engr-in-Charge.
All as per item No. 45 here-in-before but on vertical surfaces over and including 10 mm thick plaster in Cement Mortar 1:4 complete all as specified and directed.
M&L for 7mm to 8mm thick 1st quality ceramic non skid tiles coloured of area exc 0.11 Sqm but n exc 0.18 Sqm (400x400mm) in flooring set and jointed in neat cement slurry and pointed in coloured cement to match with tiles laid on 15mm thick cement screed (1:4) complete all as specified and directed.
M&L for digital coloured glazed ceramic tiles of 400 x 300 x 7mm thick and 600 x300mm size 7mm thick in vertical surfaces (including designed borders ) such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match over rendering 10 mm thick on fair faces of brick work in Cement Mortar (1:4) complete all as specified and directed. Note:- (Rate of Designer border in vertical surface will be deemed into quoted rates)
Taking down cement plaster on brick or stone walls etc including raking out of joints, hacking for key,scrubbing down with water etc. any description including disposal of all debris and complete all as specified and directed.
M&L for 10mm thick cement plastering on ceiling surfaces and finished the surfaces even and smooth w/o using extra cement in Cement Mortar 1:3 complete all as specified and directed
M&L rendering 15mm thick in Cement Mortar 1:6 on fair faces of brick or concrete, external surfaces of walls finished the surface fair and even without using extra cement complete all as specifed & directed.
M&L rendering 15mm thick in Cement Mortar 1:4 on other than fair faces of brick surfaces of walls at any height finished the surface fair and even without using extra cement complete all as specifed & directed.
M&L for for two coat of oil bound distemper including prepration of new ceiling surface and priming plastered and other surfaces with alkali resistant priming paint over 3 to 5mm thick wall care putty complete all as specified and directed
M & L preparation of new surfaces of walls plastered or unplastered and applying two coats of cement base paint over a coat of primer to walls to obtain uniform surfaces including making good the surface complete all as specifed & directed.
M&L for preparation of new plastered surfaces of wall and applying 2 mm thick wall care putty and applying two coats of Oil Bound Distemper over a coat of chalk whiting complete all as specified & directed.
M&L for complete removal of existing treatment and appling two coat of cement base paint over one coat of primer complete all as specified and directed.
M & L for applying one coat of synthetic enamel paint to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of old steel surfaces including primer complete all as specified and directed.
M & L for complete removal of existing treatment from old decorated wall surface by scrapping by electrically operated grinder machine and applying priming coat of chalk whiting followed by two coats of Oil bound distemper of any tint on walls complete all as specified and directed.
M&L for preventive treatment against the danger of carbonation in exposed laces of RCC members:- (i) Cleaning existing surfaces of RCC members and making surface free of loose material oil grease etc.by vigorous wire brushing including light gril blasting where necessary recommended by Engr in charge. (ii) Further cleaning using biocide(as recommended by manufacturer) to ensure that surface is algae and fungus free and no trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer(as recommended by manufacturer) over dry cleaned surface as required prior to final finish.Primer shall be diluted in proposition 2:1 with mineral turpentine,after application primer shall be allowed to dry for 03 hrs or as directed. (v) Apply a coat of neat aliphatic acrylic anti corbonation (ACC) over the primed surface with air/spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufaturer. (vi) Apply a more coat of aliphal anti corbonation (ACC) after 5 to 6 hrs as recommended by manufaturer complete all as specified and directed.
M&L for followings:- (i) removing plaster & finishes all around the columns,slabs & beams(on all four sides of column to full height. Three sides of beam to entire span & bottom of slab to area as directed) (ii) after cleaning gently removing cover concrete using pnaumatic/electric chipper or any other aprroved tool in entire portion of structural member removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member removal cover concrete shall be done to an extent when reinforcement is visible. (iii)removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed (concrete shall be slopped to an extent concrete substrate is exposed. (iv) Cleaning exposed concret substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved.(The Engr in charge may order sand blasting if rust is approved) (vi) Any other work as directed by Engr in charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof/anti corrosive treatment to bars:- (i) Cleaning of all exposed bars (new & old) around. (ii) Apply a single coat of alkaline rust converting primer on all round bars new or old as recommenede by the manufacturer (iii) apply two coats of epoxy phenolic anti corrosive protective coat on bars alround new or old as recommended by the manufacturer. (Note: Anti corrosive treatment shall be continuous espcially in the regions where pitting imperfections etc where present on the surface of the bars. it is important that the rear portions of re bars (those towards the concrete substrate should not be left without coating)
M& L for providing PMM(poly modified cementitious mortar):- (i) Dry sub state surface and free of debris & dust (ii) Applying epoxy bond coat on the sound substate using approved spray machine & ensuring that no pin holes are visible (in case pin holes are still visible after a coat,a second coat shall be applied to ensure absence of pin holes) (iii) Immediately after applicaion of epoxy bond coat as above apply PMM (polymer modified cementitious mortar) of 25mm thick. Note (Application of PMM shall be prefeably be in coats of appx 10mm thickness PMM work shall be excuted in fairely rapid successions so as entire work is completed with in 30 mins)PMM shall be pre packed ready to use (iv)PMM surface to be moist cured for three days followed by air curing in temp as recommended by manufacturer complete all as specified and dircted.
Taking down chowkhat or frames (without taking off shutter from the frame) not exc 1.50 sqm each complete all as specified and directed.
All as per item No. 63 above but exc 1.50 sqm but not exc 4.00 sqm complete all as specified and directed.
M&L for Framed work as in doors, Chowkhats or gates of angle or other section with gusset plates, rails, braces,and hold fast etc. confirming to Fe 290 gde E 165 complete all as specified and directed.
S&F solid PVC moulded door frame of size, 50x47mm, made out of 5mm thick plain colour PVC sheet, reinforced with MS square tube fixed with screw/plugs to brick walls complete all as specified and directed.
S&F Factory made solid panel PVC moulded door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails,MS frame shall be covered with heat moulded of any colour PVC 'C' chanel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the tiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing including 3 Nos 100mm PTMT Hinge, 2 Nos 150 mm PTMT Tower bolt and 2 Nos 150 mm PTMT handle complete all as specified and directed.
S & F flush shutters 32 to 35mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete al as specified and directed.
Supply, fabricating and fixing windows of powder coated aluminium section two track with two sliding shutters with following sections : (a) Frame section shall be 63.50 mmx38.10 mmx2 mm thick. (b) Two track bottom rail for sliding of shutters 61.85mm x 31.75mmx2mm thick. (c) Two track top section shall be 61.85mmx31.75mmx2mm thick (d) for sliding shutter handle& 'H' bottom section should be 40mmx(18mm+9)mmx1.45mm thick (e) sliding shutter to be provided with 5.5mm thick sheet glass (tinted, plain, frosted) (f) stainless steel wire clothes 0.36mm nominal dia of wire and average width of aperature 1.40mm and solar film complete all as specified and as directed.
S&F powder coated Aluminium grill 8 to 10mm thick fixed with separate channel to window/ventilator complete all as specified and directed
M&L for powder coated aluminium frame ventilator shutters, sliding type with or without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, 4 to 5mm thick glass panes,rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays/lock, Rollers, hinges type B-21 100mm long (2 no.) suitable handle (1 no per shutter) complete all as specified and directed.
M&L for 18/19 mm thick block board exterior grade decorative type fixed with screws to timber frame works with decorative face veneer on both sides, including frames and taking down old one including provision of fixing arrangement /fixing & fixtures (magnetic catches,piono hinges and knob etc) complete all as specified and directed.
S&F of 18/19mm thick PVC moulded solid board one side prelam for cabinet boxes etc with self and shutter full size fitted under/ above the kitchen cooking platform and other platform including provision of fixing arrangement /fixing & fixtures (magnetic catches,piono hinges and knob etc) complete all as specified and directed.
S&F 300mm long mild steel sliding door bolt, stove enamelled black with bright belt not less than 12mm dia with and including a minimum of 6 belts and nuts four on belt plate and two on stapple plate complete all as specified and directed.
S&F 200mm long Aluminum anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long Aluminum handles, cast type anodised complete all as specified and directed.
S&F 100mm long MS butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 140mm long floor door stopper of Aluminum alloy body and tongue, anodised with hand drawn steel spring fixed in floor complete all as specified and directed.
Cutting holes in brick walls (exc half brick but not exc one brick) built in cement mortar for inserting hold fast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 complete all as specified and directed.
S&F stainless steel 25mm dia stainless steel curtain rod of medium weight and fixing brackets, finsals decorative end supports etc complete all as specified and directed and as approved by GE.
Taking up or down 15 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches complete all as specified and directed.
Refixing 15 mm bore old steel tubing and conncetions in new or old position to walls complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning or refixing or removal to store complete all as specified and directed.
S&F 20 mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches complete all as specified and directed.
Refixing 20 mm bore old steel tubing and conncetions in new or old position to walls complete all as specified and directed.
S&F in repair 20 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
Dismantling of water tanks exc 250 ltrs & n. exc 500 ltrs capacity and removing to store complete all as specified and directed.
Dismantling of water tanks exe 500 ltrs not exe 1000 ltrs capacity and removing to store complete all as specified and directed.
S & F 1000 Ltr cap Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed in SSR Part-I.
S&F for Mirror cabinet 350 x 450 mm compete all as specified and directed.
S & F in repair ball brass valves, high pressure, with polyethene float and flynut screwed for iron pipe of 20mm dia complete all as specified and directed.
Taking down/Dismantling eaves gutter, rainwater pipes and CI soil,PVC (any type) including all fittings heads, shoes, bends, swan necks etc including cleaning for refixing or removal to store complete all as specified and directed.
S&F 100 mm dia cast iron soil spun pipes, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with stack clamps or laid in floors complete all as specified and directed.
S&F 75 mm dia cast iron soil spun pipes,waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with stack clamps or laid in trenches or in floors complete all as specified and directed.
S&F in repair 100 mm dia cast iron floor trap including joints, etc complete all as specified and directed.
S&F in repair 100 mm dia cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F in repair 100 mm dia cast iron branch pieces,single (equal or unequal) Tee, sockets, etc with oval access door if required and fitted with stack clamps, etc complete all as specified and directed.
S & F Vitreous China wash down water closet pan (pedstal pattern) white (squatting pan & trap including connection to drain) or out going pipe and to flushing pipe anti syphonic pipe etc and fixed in repairs complete all as specified and directed.
S & F in repairs plastic water closet seat , black/white, closed pattern with flat bottom & cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F in repairs 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve, float, chain and pull and brackets etc complete all as specified and directed.
S&F in repair 15 mm bore Bib taps fancy type cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron pipe or brass ferrule fixed complete all as specified and directed.
S&F in repair 15 mm bore angle cock with flange, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore 2-way angle cock with flange, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore centre hole basin mixer W/o pop up, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore wall mixer 3-in-1 (with provision for OHS & Hand shower both), screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair vitreous china wash hand basin white flat back of size 550mmx400 mm including cutting for and pinning in end of brackets,15mm angular stop cock,32 mm waste fittings,PVC connections as per reqd size ,brass chromium plated for glazed ware sinks,basins etc.including 15 mm bore CP fancy type piller tap with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed.and flush pipe of polytethylene of low or high density or PVC 32 mm dia complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed stoneware) set in cement mortar 150 mm internal dia of pipe complete all as specified and directed.
S&F Reinforced concrete pipes,class NP2 laid and jointed complete with collars ware drain pipes laid in trenches and jointed internal dia of pipe 150 mm complete all as specified and directed.
M&L cement mortar concrete bed to drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) including packing under and haunching against the sides of pipes after they are laid and tested in bores of pipe 150 mm dia complete all as specified and directed.
Cutting into existing manholes for connecting new mains pipe making good to pipes rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finish and reforming benching as required, internal dia of pipe 150 mm dia complete all as specified and directed.
S&F in repair over head shower with arm & flange , etc complete all as specified and directed.
S&F in repair Handshower with 1.5 mtr flexible tube and hook complete all as specified and directed.
S&F in repair for toilet paper holder compete all as specified and directed.
S&F in repair for soap dish compete all as specified and directed.
S&F in repair for health faucet with 1 mtr tube and hook compete all as specified and directed.
S&F in repair sink with drainage board made of 1mm thick stainless steel, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair for towel rail compete all as specified and directed.
S&F in repair corner glass shelf 300 mm with ABS brackets complete all as specified and directed.
S&F in repair for Looking mirror 600 x 450 mm compete all as specified and directed.
M&L for Providing precast cement concrete louvres and jallies type B-0, 1:2:4 using 12.5 mm graded stone aggregate and set in cement mortar 1:6, 35mm thick (measured solid), including all mouldings but excluding frame and applying two coats of white wash including demolition of concrete compete all as specified and directed Engr in charge.
S&F factory made precast reinforced cement concrete manhole cover(RCC 1:2:4, using 20 mm graded stone aggregate) 100 mm thick (Square/rectangulr/circular) with and including 10 mm dia TMT bars and placed over manholes at site complete all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundations of walls and not exc 10 Sqm on plan and n.exc 1.5m in soft soil complete all as specified and directed.
Returning and filling in soil incl levelling, watering and well rammingin layers n. exc 25cm in foundation trenches complete all as specified and directed.
Removing excavated soil including disposal of all debris exc 1.5 KM not exc 5 Km outside of MOD land complete all as specifed & directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
Taking down ceiling fan, exhaust fan including connection cable, dismantling blades and removing fan and blades to MES stores all as specified and directed by Engg -in-charge
M&L point wiring for modular switches or normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through concealed Conduit as requirement of site including cadmium plated screws as per ISS, including replacement of 3 mm thick phenolic laminated sheet top covers on and including sunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single polecomplete all as specified and directed.
All as per item No. 130 above but one fan point controlled by one switch 5 Amps one way single pole complete all as specified and directed.
All as per item No. 130 above but one three pin 5 Amps socket out let on independent board complete all as specified and directed.
All as per item No. 130 above but one three pin 5 Amps socket out let on same board complete all as specified and directed.
All as per item No. 130 but one bell point controlled by one bell push independent complete all as specified and directed.
All as per item No. 130 but one light point controlled by two way switch complete all as specified and directed.
All as per item No. 130 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
All as per item No. 130 above but point wiring of copper cable multi stranded 4.00 Sqmm size for AC point wiring with 4.0 Sqmm size of earth conductor complete all as specified and directed.
Supply and fix in repair Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete all as specified and directed.
S & F in replacement modular type Ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , one way 10 Amps complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , two way 6 Amps complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , one way 15 amps complete all as specified and directed.
S&F in repair Modular socket outlet 3 pin and 2 pin , 10 amps , flush type complete all as specified and directed.
S&F in repair Modular socket outlet 2-in-1, 3 pin, 10 and 20 amps , flush type complete all as specified and directed.
S&F in repair modular type one way electronic fan regulator (5 Step up type) 280 Volts suitable for ceiling fan complete all as specified and directed.
Supply and fix in repair for Modular Bell push 6A 1 Module complete all as specified and directed. Make :- Legrand Cat Part No :-573413 or equivalent in Anchor woods/ Philips
S&F in repair existing sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 25 Amps , 240 Volts complete all as specified and directed.
M & L Sub main wiring using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note Two runs of 2.5sqmm copper FRLS cable & one run of 2.5 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
M & L Sub main wiring using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note Two runs of 4sqmm copper FRLS cable & one run of 4.0 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
M & L Sub main wiring using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note Two runs of 6 sqmm copper FRLS cable & one run of 6.0 sqmm copper cable in and including 32mm PVC conduit medium grade will be measured as one unit.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 10 sqmm with rigid non metalic PVC conduit of size 40 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 10 Sq mm etc complete all as specified and directed. Note four runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 40 mm PVC conduit medium grade will be measured as one unit.
S &F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 507612 or equivalent in Seimens/ Scheneider/ L&T/ ABB/ C&S Electric/ Havells
S &F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed.
S & F in repair with taking down distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 4 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 100 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed.
S & F in repair with taking down distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 8 way with 200 Amps rated copper busbar, 415 Volts, MCCB 100 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed.
S & F in repair with taking down distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 12 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 160 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 507748 or equivalent in Seimens/ Scheneider/ L&T/ ABB/ C&S Electric/ Havells
S & F in repair MCB TPN, 415 Volts, 40-63 Amps complete all as specified and directed.
S & F in repair MCB SPN, 240 Volts, 40-63 Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 6-32 Amps Ç'type complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 40 Amps Ç'type complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 63 Amps Ç'type complete all as specified and directed.
S & F in replacement for existing 36/40 Watt tube light fiiting by energy efficient LED light fitting 18/20 Watt,230 Volt of 1200 mm + 50 mm length along with fixture, heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed.
S & F in replacement for existing 18/20 Watt tube light fiiting by energy efficient LED light fitting 9/10 Watt,230 Volt of 600 mm + 60 mm length 6000 K colour temp ,decorative ultra slim linear LED lighting fixture with extruded Al. heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed.
S&F in repair Bldg security light fitting LED 45 Watt cast aluminium housing, toughened glass,silicon gaskect, high power LED with lens for uniform istribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including GI bracket 1.5 Mtr with clamps and bolts complete all as specified and directed. Make - Crompton Cat pt no-LSTS-45-CDL-1 or equivalent in Havells/ Bajaj/ Crompton Greaves/ C&S Electric/ Polycab
S &F in repair Earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of the plate not less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 5 of SSR of part-I (1991) complete all as specified and directed by Engr-in-charge.
S and F ceiling fan 1200mm, BEE 5 star rating including suitable size of down rod and flexible wire 2 core of size 23 X .0076' and clamps and nut and bolts complete all specidied and directed. Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
S& F exhaust fan 300 mm dia sweep, 900 RPM, 240 Volt heavy duty exhaust fan with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed. Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
S& F exhaust fan 250 mm dia sweep, 900 RPM, 240 Volt plastic body exhaust fan with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed. Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
S & F Water heater geyser of capacity 25 Ltr AC Single Phase 240 Volts, 2 KW 5 star rated with all assessories such as copper tank, assembly, element including plumbing works, elect connection ,geyser mounting , including hot and cold water duty free pvc pipes of size 15mm bore and 60cm long for connection and inlet and outlet pipe line connection , inside the existing wall and making good disturbed surfaces complete all as specified and directed by engineer in charge. Note :- Old unserveciable water heater will be deposited to MES store yard.
S&F in repair of modular white cover plate with frame , 2 module complete all as specified and directed. Make:Anchor Roma /Crab tree
S&F in repair of modular white cover plate with frame , 3 module complete all as specified and directed. Make:Anchor Roma /Crab tree
S&F in repair of modular white cover plate with frame , 6 module complete all as specified and directed. Make:Anchor Roma /Crab tree
S&F in repair of modular white cover plate with frame square type , 8 module complete all as specified and directed. Make:Anchor Roma /Crab tree
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. & cutting chases for concealed water tubing or concealed conduit wiring, etc & making good, cutting not exc 10 cm girth complete all as specified and directed.
S and F in repair Rigid non-metallic PVC conduit of 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
S & F in repair ding dong bell complete all as specified and directed. Make Anchor / Havells/ Cona
S & F in repair LED bulk head of 10W complete all as specified and directed. Make Hallonix cat No. HLBH-02-10-CW or equivalent in Havells/ Bajaj/ Crompton Greaves/ C&S Electric/ Polycab
S & F with Taking down existing AC Single Phase Two Wire, static energy Meter with LCD display of Class 1.0, 240 V, 50 Hz, 10-60 A ,conforming to IS-13779 and relevant IEC standards,including transparent hinge type meter box made from engineering plastic and required length of 6 Sqmm copper stranded wire PVC insulated 1100 Volt grade and taking down old unserviceable meter complete all as specified and directed. Note-Old dismanteled energy meter shall be deposited to the MES store syard.
S&F for 100mm cast iron cowls complete all as specified and directed.
M/s GANJOO AND CO
Shivom Projects Private limited
imran construction company
M/S Yamin
n s kumar and sons
Shiv Shankar Nirman Co.
M/s M M BAHL
JAIN BUILDER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .