| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹13.6 L+₹94,831.50 (7.52%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 | |
| 3 | L3₹14.1 L+₹1.5 L (11.6%)Rejected-Finance ALPHA HOUSE PLOT NO 29 AGP P10 ASHWIN SECTOR NEW CIDCO NASIK 422 009 | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance SINCE NOT L1 | |
| 4 | L4₹14.7 L+₹2.0 L (16.2%)Rejected-Finance | L4 | Rejected-Finance SINCE NOT L1 | |
| 5 | L5₹15.4 L+₹2.8 L (22.4%)Rejected-Finance | L5 | Rejected-Finance SINCE NOT L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
4 Feb 2021, 6:00 pmClosed
GE DEOLALI
GE DEOLALI, 422401
SPL REPAIRS TO BLDG NO.T09 URO SHED OF MT BTY, SPL REPAIRS TO ROOF TREATMENT OF BLDG NO.P447 P448 IN C MAGZINE AND PROVN OF NEW WATER SUPPLY CONNECTION AT JCOS /ORS MD ACCN OF 70 COY ASC TYPE C UNDER THE AOR OF GE DEOLALI
2020_MES_408148_1
8939/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEOLALI
CLASS E cat a i
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹30,000
Yes
22 Mar 2021
30 Dec 2020
6 Feb 2021
30 Dec 2020
4 Feb 2021
22 Jan 2021
Amount
Dismantling of manglore pattern roofing tiles laid dry etc complete all as specified and directed.
Dismantling of timber battens for tiles of any size including tilting fillets spaced exc 15cm centres etc complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position framed work etc complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E- 250) quality-A
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
M& L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking down cement plaster on brick masonry walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
M&L for 10mm thick rendering in CM 1:6 finished even & smooth without using extra cement complete all as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete.
Demolition of plain cement concrete (un reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) in copings as in adjoining to roof sheet and wall and like etc and finishing of exposed surfaces smooth etc including formwork if any complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate ) in foundations, flooring etc complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M & L for preparation of new plastered surfaces of walls and apply two coats of oil bound distemper over a coat of 3mm (2mm +1mm) wall care putty complete all specified and directed.
M & L for preparation of new plastered surfaces of walls and apply two coats of cement base paint over a coat of 3mm (2mm +1mm) wall care putty complete all specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered wall surfaces and applying two coats oil bound distemper over a coat of 3mm (2mm +1mm) wall care putty all as specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered wall surfaces and applying two coats of cement base paint over a coat of white wash all as specified and directed.
Dismantling and taking down of lightning conductor including air termination, aluminium/ GI strip and insulators from the roof of building all as specified and directed
Supply & fix single pointed air termination Copper rod 12mm dia and 300 mm long incl support block incl taking down u/s complete all as specified.
Supply and installation of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawin in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm GI strip incl taking down u/s strip any type complete
Supply & fix aluminium strip 25mmx 3mm as a roof conductor or down conductor complete all with saddles and fixing screws for fitting the strip incl taking down any type strip complete all as specified and directed .
M&L for HDPE/porceiline insulator suitable for fixing earthing strip to the wall / floor/pole or any indicated location etc all as specified and directed
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm , drilled and screwed including 3 nos. 8mm dia 25 mm long hex. head screw, complete with suitable polycaronate box with locking arrangement all as specified and directed by Engr-in-charge.
M&L for maintenance free Chemical Earthing of Dual Pipe Technology of 3 Meter long with Outer pipe Diameter of 88 mm & inner pipe diameter 48 mm, the pipe outer surface is properly copper coated up to 250 micron and Wall thickness of inner pipe 2.6 mm and 1.8 mm of outer pipe. The terminal for connection of 75 X 5.2 mm with two holes of 14mm diameter electrode is dully filled with the highly conductive material with sealing at both ends with lead terminal of 75 X 5.2 mm at top. The electrode shall be duly tested & certified by CPRI (Central Power Research Institute), Govt. Of India for a minimum short circuit current of 42 kArms for 1 Second with initial pick of 88.2 kA. The Electrode should be tested in MSME Govt of India. The Electrode should be type tested for Salt Spray test as per BIS 117-09 for corrosion for minimum 500 hrs.Along with Supply of Fast Electrode Earth Enhancing Compound of 25kgs each. The chemical compound should be tested and certified by any international accredited and BIS (Bureau of Indian Standards) accredited laboratory.
M & L for Earthing complete with galvanised Mild steel earth plate electrode size 600 x600x6 mm thick buried directly in ground (preferably in vertical position earth pit not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 3 mm (BGL) connected to galvanised iron strip 32x6mm as earthing lead by means bolts, nuts check nuts including PCC pit in RCC 1:2:4 type B-I, 20 mm bore medium grade, GI water tubing fixed with CI funnel wire mesh 15 mm light grade for protection pipe including charcoal common salt complete all as specified in EP No 3 of SSR -1991 Part-I connected to test point complete all as specified.
M&L for PCC block of size 45cmx 45cm x50cm in 1:2:4 type B-1 for fixing/embedding of GI Pipe which is fitted in Air termination complete all as specified and directed.
S&F tubes light grade, galvanised, with all fittings, laid in trenches and/or fixed in wall/ roof, etc. with suitable size of clamps, nuts bolts and washers for fixing of air terminal, bore pipe 50mm dia.
S&F tubes light grade, galvanised, with all fittings, laid in trenches and/or fixed in wall/ roof, etc. with suitable size of clamps, nuts bolts and washers forProtection og GI/ Aluminium Strip, bore pipe 40mm dia.
Taking down existing water proofing treatment of any description, thickness and in any position including removal of rubbish of the premises etc complete all as directed.
M&L for Plain Cement concrete type Bo 1:2:4 (using 12.5mm graded stone aggregate) 25mm thick as in roof to achieve slope on existing roof surface all as directed.
M&L rendering 10mm thick plaster in CM 1:4 on roof slab using water proofing compound @ 3% by weight of cement finshed even and smooth without using extra cement etc complete all as directed. Note : Water proofing compound will be measured and paid separately.
Supply only Integral water proofing compound
M&L for preparation of surfaces and applying water proofing treatment are as under :- (i) Applying one coat of bituminous primer @ 0.25 Kg/Sqm. (ii) Laying torch applied APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. (iii) Applying aluminium bituminious paint 0.11 Kg/Sqm.
Excavation in trenches not exc.1.5 m wide and not exc 1.5 m depth (for taking out and laying of water pipe line and getting out in soft/loose soil complete all as specified and directed.
Returning filling in trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as directed.
Removing of excavated material not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply , laying, connect and test GI tubing 50mm bore medium grade ISI marked with all fittings laid in trenches etc complete all as specified and directed.
Supply , lay, connect and test GI tubing 20 mm bore medium grade ISI marked with all fittings and fixed complete walls and ceilings or laid in floors etc complete all as specified and directed.
Supply , lay, connect and test GI tubing 15mm bore medium grade ISI marked with all fittings and fixed complete walls and ceilings or laid in floors etc complete all as specified and directed.
Supply and fixing gun metal globe or gate valve with iron wheel head screwed both end for iron pipe and fixed of 50 mm bore
Material and labour for replacement bib tap cast copper alloy chromium plated fancy type with crutch or butterfly handle screwed down , for iron pipes of size 15mm complete all as specified and directed .
Cutting the existing road surface i.e.surfacing WBM soiling any type of soil etc and making suitable trench of minimum 100mm x 60 cm deep along the cross section of road for Lying GI Pipe, returning refilling, filling, well ramming and removal of surplus surface soil to a distance not exceeding 50 m and repair to road surface to match the existing specifications complete.
Tapping the existing CI/GI distribution main in position for taking tapping/branch connection upto 150 mm all as specified and directed.
Note: Amount of sch of credit of Rs.16,970.00/- will be deducted from total amount of BOQ.
M/s KISHOR CHHAGAN WAGH
Alpha Construction
Vishal Constructions
Vinod Enterprises
RELIANCE ELECTRONICS
M/S YOGESH CONSTRUCTION
DEVA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .