| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.2 L+₹1.9 L (5.51%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹37.1 L+₹2.8 L (8.25%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹40.6 L+₹6.2 L (18.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹40.9 L+₹6.6 L (19.4%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
2 Sept 2021, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF INTERNAL ELECTRIFICATION AND FIXTURES AT CERTAIN OTM ACCN AND REPAIR MAINT OF DG SET AND SEWAGE PUMPS AT BAIRAGARH UNDER GE BHOPAL
2021_MES_467473_1
8817/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹78,000
Yes
14 Oct 2021
12 Aug 2021
4 Sept 2021
12 Aug 2021
2 Sept 2021
27 Aug 2021
Amount
Servicing of DG sets of capaity from 110 KVA to 200 KVA Make- Ashoka wand, Ruston & cummins at 250 running hours or 6 months whichever is earlier including replacement of defective / warnout parts by new spares such as filters, gaskets, V belts Engine oil, rubber hoses, worm drive clamps, nuts & bolts and B check kit complete all as specified and directed. NOTE:- (i) Spares/parts shall be paid under relevent item here-in-after under as supply only. (ii) Cost of Minor spare parts; which are not included in subsequent items given herein-after but are required for making the making the motor functional is deemed to be included in the quoted basic rate.
Supply only the following parts suitable for 110 KVA to 200 KVA DG set as per original manufacturers specification complete all as specified & directed. NOTE:- Cost of Minor spare parts; which are not listed below but are required for making the making the motor functional is deemed to be included in the quoted basic rate of respective item.
Element fuel filter Cat No-3238203
Element fuel filter Cat No-3238493
Kit supper by pass filter Element Cat No-3879488
Plug pipe Cat No- S-995
Plug pipe Cat No- S-915 A
Plug pipe Cat No- 67622
Hose flexible Cat No- AK-5033 SS
Cotrol Safety (Water), Part No-194505
Control Safety (Lub Oil) , Part No-194504
Servicing of DG sets of any capaity from upto 50 KVA Make- Kirlosker, Ruston & cummins at 250 running hours or 6 months whichever is earlier including replacement of defective / warnout parts by new spares such as filters, gaskets, V belts Engine oil, rubber hoses, worm drive clamps, nuts & bolts and B check KIT complete all as specified and directed. NOTE:- (i) Spares/parts shall be paid under relevent item here-in-after under as supply only. (ii) Cost of Minor spare parts; which are not included in subsequent items given herein-after but are required for making the making the motor functional is deemed to be included in the quoted basic rate.
Supply only the following parts suitable for 50 KVA DG set as per original manufacturers specification complete all as specified & directed. NOTE:- Cost of Minor spare parts; which are not listed below but are required for making the making the motor functional is deemed to be included in the quoted basic rate of respective item.
Element fuel filter
Element oil filter
Kit supper by pass filter Element
Plug pipe Cat No- S-995
Plug pipe Cat No- S-915 A
Plug pipe Cat No- 67622
Hose flexible
Cotrol Safety (Water),
Cuppling Suitable for exising DG Set with Lubjoy rubber cuppling
Servicing of DG sets of any capaity from 320 KVA Make- Cummins at 250 running hours or 6 months whichever is earlier including replacement of defective / warnout parts by new spares such as filters, gaskets, V belts Engine oil, rubber hoses, worm drive clamps, nuts & bolts and B check KIT complete all as specified and directed. NOTE:- (i) Spares/parts shall be paid under relevent item here-in-after under as supply only. (ii) Cost of Minor spare parts; which are not included in subsequent items given herein-after but are required for making the making the motor functional is deemed to be included in the quoted basic rate.
Supply only the following parts suitable for 320 KVA DG set as per original manufacturers specification complete all as specified & directed. NOTE:- Cost of Minor spare parts; which are not listed below but are required for making the making the motor functional is deemed to be included in the quoted basic rate of respective item.
Element Lub oil Cat No-3238204
Element Fuel filter Cat No-3238493
Kit supper by pass filter Element Cat No-3879488
Belt V Cat No- 3001600
Belt V Cat No- 178567
Hose flexible Cat No- AK-5041 SS
Hose flexible Cat No- AK-6045 SS
Hose flexible Cat No- AK-6065 SS
Hose flexible Cat No- AK-10075 MS
Hose flexible Cat No- AK-10024 SS
Hose flexible Cat No- AK-10030 SS
Hose flexible Cat No- AK-6054 ST
S&F in replacement diesel filter suitable for 63 KVA and upto 110 KVA Primery & secondary DG set Make-Ruston complete all as specified and directed.
S&F in replacement Engine oil filter suitable for 63 KVA and upto 110 KVA DG set Cat No-1260370120 complete all as specified and directed.
S&F in replacement the following parts as per original manufacturers specification complete all as specified & directed. NOTE:- Cost of Minor spare parts; which are not listed below but are required for making the making the motor functional is deemed to be included in the quoted basic rate of respective item.
Air cleaner elements inner and outer for 110 KVA to 200 KVA DG sets of cummins make .(Inner & outer)
Air cleaner elements inner and outer for 320 KVA DG sets of cummins make .Cat No-3226018, 3226019 (Inner & Outer )
Battery turminal heavy duty brass with nut & bolts complete.
Petrolium jelly in 1 kg plastic sealed container.
Battery lead for 180 AH 12 volts battary copper conductor PVC insulated multisranded 1.5 mtr longe duly fixed with turminals & lugs .
Bty link lead with Bty terminal of +/- terminal 0.3 mtr long
Oil pressure gauge suitable for YDA serise DG set
Supply and filling in sump / topping up engine oil, multi grade 20w / 40 in engine or relpacement of engine oil complete all as specified and directed. Make :- Indian oil / Hindusthan petrolium / Castrol / Pried /Servo
Repair overhauling and removel of leakage from radiator & refixing it duly repaired, cleaning descaling, welding brazing etc . including replacement of rubber hoses & clips etc. complete in all respect of 100 KVA to 320 KVA DG sets complete all as specified and directed.
Repair overhauling and removel of leakage from radiator & refixing it duly repaired, cleaning descaling, welding brazing etc . including replacement of rubber hoses & clips etc. complete in all respect of 10 KVA to 100 KVA DG sets complete all as specified and directed.
Repair / overhauling of self starter 10 KVA -320 KVA (make lucas) including replacement of carbon brusses, bearing, bushes, rewinding of armature and fild etc. complete all as specified and directed.
Spray painting of 110 KVA to 200 KVA DG sets, Alternator, Panel, diesel tank and base frame etc. with one coat of synthetic enameld paint as per MES colour code after cleaning of old painted surface rubbing of old paint and making surface for paint etc complete all as specified and directed.
Spray painting of 320 KVA DG sets, Alternator, Panel, diesel tank and base frame etc. with one coat of synthetic enameld paint as per MES colour code after cleaning of old painted surface rubbing of old paint and making surface for paint etc complete all as specified and directed.
Spray painting of 10 KVA to 100 KVA DG sets, Alternator, Panel, diesel tank and base frame etc. with one coat of synthetic enameld paint as per MES colour code after cleaning of old painted surface rubbing of old paint and making surface for paint etc complete all as specified and directed.
S&F heat proof Asbestos rope 12 mm dia in engine exhaust pipe including dismantling of worn out Asbestos rope and minor welding / tightning in leakage exhaust complete all as directed conferming to IS specification fire proof/flame proof etc complete all as specified and directed.
Calibration and over hauling FTP or PT Pump of 62.5 KVA t0 110 KVA DG Set with replacement of the following parts complete all as specified and directed :- (a) Delivery valve - 06 Nos. (b) Bearing - 02 Nos. (c) Elements - 06 Nos. (d) Main spring - 06 Nos. (e) Gasket sets. (f) Seal. (g) Cap screw. (h) 'O' ring - 01 Set. (j) Governer assembly - 01 Set. (k) Screen filter.
Dismantling of unserviceable self starter of capacity 24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of one field coil, repair and rewinding of armature and return to the existing place after repairing, complete all as specified and directed.
Earthing complete with GI steel earth plate electrode 60cm x 60cmx6.3mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI iron or steel earth wire 4mm dia (8 SWG) by means of nuts, volts checks nuts and washers made of GI iron or steel earth wire protected by GI iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Part-I and testing after completion.
Supply only the following items for various DG Sets.
Battery 12 volts 92 AH (Make Exide.)
Battery 12 volts 180 AH (Make Exide.)
Rubber coupling.
Repairing of diesel engine generating set, capacity 110 KVA and dismantling of the engine strip opening etc complete all as specified and directed. (a) Valve seat cutting and fixing of the valve guide. (b) Griding and polishing of crank shaft complete. (c) Fixing of the cylinder liner. (d) Cylinder block line bearing and threading of existing holes. (e) Fixing of the piston ring complete. (f) Repair to cylinder head, injector sleeves including fixing and testing complete. (Note : All spare parts for replacement/fixing shall be supplied under relevant items).
Testing of collected water sample from NABL lab from Bairagarh all as specified and directed
Main filter pump house, Bairagarh
TRS Pump House, Bairagarh (at 115 ER Unit Area)
Key personnel Pump House, MES Colony Area
21 CGSR Pump House
Swimming Pool Bairagarh
S&F Change Over switch 4 pole 250 Amps, 50 KA complete all as specified and directed. Make - L&T/siemens/Schneider
S&F Change Over switch 4 pole 450 Amps, 50 KA complete all as specified and directed. Make - L&T/siemens/Schneider
Disconnecting / Dismantling of 5/20 HP Non Clog motor Pump Set assy from its foundation at Sewage Pump House Bairagarh and transporting to civil workshop for repair complete and taking back after repairing, fixing to its existing position and making all connections.Dismentling and opening of pump assy for checking out defects. Taking out shaft from pump and carrying out lathe work on shaft for checking and making straightness. Taking out of old worn out brass impeller and M&L for filling material on worn out part , grinding, poilshing and carrying out complete lathe work, refixing on shaft and check for its smooth functioning and balancing complete all as specified and directed. NOTE:- (i) Spares/parts shall be paid under relevent item here-in-after under as supply only. (ii) Cost of Minor spare parts; which are not included in subsequent items given herein-after but are required for making the making the motor functional is deemed to be included in the quoted basic rate.
Removing of burnt winding, cleaning of slots and Rewinding of 5/15/20 HP motor with new high class insulated copper wire of existing gauge, insulation paper, varnishing, heating etc. complete all as specified and directed.
Supply only the following parts suitable for 5/20 HP Non Clog motor Pump as per original manufacturers specification complete all as specified & directed.
Bearing
Impuller
Ishpenter Bush
Neck Ring
Shaft Turning
Rotor Seal
Bowl bush
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/ one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor FRLS as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ L&T/ Havells] Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Rate includes chase cutting for concealed wiring.
All as per item No. 30.00 here-in-before but for one light point controlled by two 2 way switches, with FRLS cables of 1.5 sqmm complete all as specified and directed.
All as per BOQ item No. 30.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No. 30.00 above, 3 pin 5 Amps switch socket combination on independent board with other switches complete all as specified and directed.
All as per item No. 30.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item No. 30.00 here -in- before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
M&L for point wiring for one light / fan / bell point/one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in existing concealed/surface conduit including one run of 1.5 sqmm copper conductor FRLS as earth continuity wire connected to common earth dolly by suitable lugs and 3mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed. [Make of Cable : Polycab/ L&T/ Havells] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No. 36.00 above, but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per BOQ item No. 36.00 above, one 5 Amps socket outlet point controlled by one switch on independent board with other switches complete all as specified and directed.
All as per BOQ item No. 36.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No. 36.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item 36.00 herein before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/one 3 pin 5 Amp socket outlet on independent board with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, including sunken box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface, including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code. Make of Cable : Polycab/ L&T/ Havells
All as per item No. 42.00 herein before One light point controlled by two 2-way switches.
All as per BOQ item No. 42.00 above, 3 pin 5 Amps socket outlet point controlled by one switch on independent board complete all as specified and directed.
All as per BOQ item No. 42.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per item 42.00 herein before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item 42.00 herein before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket oulet, multipurpose, 2 in 1, 3 pin, 5 & 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, one way, single pole, 16/20 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F ceiling fan regulator electronic steped type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR / LEADER/ LEGRAND /HAVELLS as approved by GE]
S&F Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 10 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 10 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 10.0 sqmm cable, one run of 10.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
Taking down old unserviceable MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar, 4 way Double door ( Vertical DB) factory made conforming to IS: 13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutal link and 200 Amp, 440 volt rated bus bar, 16 KA, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditioning protection against corossive atmosphere, IP 43 protection class. DB shall also be provided with lable marking indicating the incoming and out going circuit including suitable size rectangular board for mounting complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar, 6 way Double door ( Vertical DB) factory made conforming to IS: 13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutal link and 200 Amp, 440 volt rated bus bar, 25 KA, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditioning protection against corossive atmosphere, IP 43 protection class. DB shall also be provided with lable marking indicating the incoming and out going circuit including suitable size rectangular board for mounting complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F MCCB TPN 100 Amps, 16 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 10 KA, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 10 KA, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 16 KA, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated without busbar 16 KA, 2 way Single door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCCB TPN 40 to 63 Amps, 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F in replacement LED 20/21Watt tube light fitting (T8 type), including LED retrofit tube 20/21 W one side connection type, 240 v, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative patti suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :-Havells cat Part No. BS20WLED840SPCWH or equivalent in Philips/ Crompton/Bajaj (Titania LED tube with Regal batten LED) as approved by GE.
S&F in replacement LED tube light rod 20/21 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, to be fixed in existing or new batten/ patti including taking down of existing tube light fitting and changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting complete. Make :- Wipro / Havells/ Philips as approved by GE.
S&F in replacement LED tube Highly durable surface mounted LED batten constructed of fire retardant engineering grade extruded plastic and decorative end caps. 20/22 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, including taking down of existing tube light fitting complete. Make :- Wipro / Havells/ Philips as approved by GE.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
S&F GI tubing light grade 40 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
S&F GI tubing light grade 50 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
S&F GI tubing light grade 15 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer complete and all as specified and directed.
Supply and fixing switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type complete and all as specified and directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in replacement bulk head luminare weather proof, including one No. LED lamp 9W and connecting with copper flexible three core 23/0.0076 and all necessary fittings complete and all as specified and directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
M&L for cutting PCC/floor/road for taking out/ laying of cable, GI earth wire etc in protection pipe and making good, including material as per existing after laying of pipe for cable protection, GI wire etc, size of trench not more than 0.30 x 0.30 m complete all as specified and directed.
Supply and fixing switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type, including taking out old unserviceable Switch socket combination complete and all as specified and directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/ HAVELLS as approved by GE]
S&F in replacement LED 9/10 Watt mirror tube light fitting intergated type, approx 2 feet, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :-C&S / Wipro/ Philips/ Crompton as approved by GE.
Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm x 2 core nominal cross section in service connections in ulding taking down old cable complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/ KEI/V-MARC as approved by GE]
Excavating in trenches, nott exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
S&F in replacement surface mounted economical LED panel light 2 ftx 2ft, 36 watt with high quality diffuser for uniform light, CRCA housing, Separate replaceable electronic driver, suitable for recess and surface, CRCA panel 36ECW including LED lamp, nut, wire all connected accessories complete all as specified and directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
S&F in replacement Garden light, including LED lamp 9 Watt, 220 volt, 50 Hz complete all as specified and directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with (parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board wooden board first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specified and directed. Make : Secure/HPL/ L&T Note : Old meter to be deposite in AGE E/M store.
S&F in repair Three phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V per phase , 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board wooden board first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specified and directed. Make : Secure/HPL/ L&T Note : Old meter to be deposite in AGE E/M store.
S&F Hanging Rod of required sizes for fan, rubber type, suitable for hanging ceiling fan, complete all as specified and directed.
S&F MS Screws of required sizes for mounting fan blades / rods, suitable for hanging ceiling fan, complete all as specified and directed.
S&F MS Screws of required sizes for mounting / tightning electric boards, complete all as specified and directed.
S&F 1 Sqmm x 3 core FRLS mutistranded copper conductor flexible wire, suitable for 220 Volts, 50 Hz, complete all as specified and directed. .
S&F 2.5 Sqmm x 2 core FRLS mutistranded copper conductor wire, suitable for garden light, 220 Volts, 50 Hz, complete all as specified and directed. .
Deduct schedule of credit (calculation will be done off line) Rs. 118786.00
HRK ENGINEERING CORPORATION
ELITE WORKS
Neelam Traders
UMESH ENTERPRISES
POONAM ELECTRIC INDUSTRY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .