Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | ₹19.9 L | L1 | Accepted-AOC Accpect |
| 2 | L2₹20.9 LRejected-AOC AGGARWAL COLONY RAMPURA PHUL DISTT BATHINDA | BATHINDA | PUNJAB | 151001 | ₹20.9 L | L2 | Rejected-AOC Reject |
| 3 | L3₹23.0 LRejected-AOC | ₹23.0 L | L3 | Rejected-AOC Reject |
Tender Value
Refer Docs
EMD Value
₹54,182
Closing Date
16 Jan 2026, 3:00 pmClosed
EE MD JDH
Jalandhar
Replacement of old and unserviceable conventional Fittings with new LED Panel Batten Fittings in JCC Distt Pathankot
2026_CEPW_157574_1
16/19-12-2025
Open Tender
Electrical Works
60 days
Pathankot
Please refer Tender documents.
21 documents required · 21 mandatory
₹5,000
₹54,182
22 May 2026
9 Jan 2026
16 Jan 2026
9 Jan 2026
16 Jan 2026
9 Jan 2026
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 25sq.mm (4Core) Un-armoured (Loose)
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- 16/20amp. One Way Modular Switch with Indicator (One Module)
6amp. 2/3 Universal Modular Shuttered Socket (two Module)
16/20amp. Universal Modular Shuttered Socket (two Module)
Step type Modular Electronic Fan Regulator 100watts (Two Module)
Call Bell 220/230 volts AC Ding Dong
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 6-32amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
NSR Supply and erection of LED batten 20 watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt. Input AC frequency 50 Hz ± 3%. Housing & driver shall be of same brand,5 years warrenty including there drivers complete along with erection of the same with connections,testing etc.complete in all approved and desired by the Engineer-in-charge at site. The certification and specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.
Supply and erection of LED batten 40 watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.
Supply and erection of Recessed mounted 36watt LED panel 2'X2' (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt warranty 5 years and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.
Supply and erection of LED Flood Light 150 watt with pressure die cast aluminium housing with control gear (with IP 66 protection), toughened glass fitting, 4 KV SPD outside driver compartment within driver surge protection 10KV external SPD and efficacy of LED fixture minimum 120 lumens per watt warranty 5 years complete in all respects as approved and desired by the Engineer in-charge at site .LED Fitting as per circular issued by O/o Advisor (Technical) Govt. of Punjab Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.
Supply and erection of LED Street Light 45 watt 5400 lumens with pressure die cast aluminium housing with control gear (with IP 66 protection), toughened glass fitting, 4 KV SPD within driver compartment surge protection 10KV external SPD outside driver compartment and efficacy of LED fixture minimum 120 lumens per watt warranty 5 years complete in all respects as approved and desired by the Engineer in-charge at site .LED Fitting as per circular issued by O/o Advisor (Technical) Govt. of Punjab Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.
Supply and erection of Heavy duty Exhaust Fans 300mm 900RPM with louver shutter ,double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Ceiling Fan 1200mm 48" with double ball bearing full Aluminium Body,3 Nos of blades,White in colour, but without regulator.The product should possess a minimum air deleivery of 210 CMM (appro.).The rated speed of the product must be minimum of 300 revolutions per minte and 5 Nos. of speeds.The product should have a manufcature's guarantee /warranty of 2 years,including flexible wire and petty material etc. Complete in all respects as appd. and desired by the Engineer in-charge at site.
Supply and Erection of LED Post top 25 Watt ( with IP 65/66 protection), toughened glass fitting, 4 KV SPDoutside driver compartment within driver surge protection 10KV external SPD and efficacy of LED fixture minimum 120 lumens per watt warranty 5 years complete in all respects as approved and desired by the Engineer in-charge at site. LED Fitting as per circular issued by O/o Advisor (Technical) Govt. of Punjab Letter No.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.
Old material credit
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.19 MB
SBDcompressed.pdf
Tender Documents • 17.88 MB
BOQ_319534.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid