| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.8 LAccepted-AOC | 1 | Accepted-AOC Reasonable | |
| 2 | 2₹28.1 L+₹34,090 (1.23%)Rejected-Finance | 2 | Rejected-Finance High Rate |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
6 Feb 2020, 6:00 pmClosed
GE NDA KHADKWASLA
GE NDA KHADKWASLA
PROVN OF CONTROL PANELS TO MACHINERY INSTALLED AT CADETS MESS AND ENERGY MONITORING AND TRANSFORMER MONITORING SYSTEM AT NDA KHADAKWASLA
2020_MES_312318_1
GE (K) 54 OF 2019-2020
Open Tender
Civil Works
Item Rate
180 days
GE NDA KHADKWASLA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADKWASLA
₹58,000
Yes
20 Feb 2020
6 Jan 2020
7 Feb 2020
7 Jan 2020
6 Feb 2020
17 Jan 2020
8 Jan 2020 - 16 Jan 2020
Amount
Disconnecting LT DB/Busbar box/Panel etc from existing place and depositing to MES store, dismantling existing LT cables/ submain wiring etc from LT DB/Busbar box/Panel etc and reconnecting cable with existing size of cable lugs and cable galnds to the same to new one by taking proper shut down etc all as specified and directed.
Supply & fix control panel weather proof Indoor type Double door with wall mounting arrangement, fabricated out of 2 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated as per CPRI norms only. The Panel shall be design totally enclosed, dust and vermin proof, conforming to degree of protection IP-53, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, electrolytic grade after Incoming MCCB and Copper PVC cables of adequate rating for all outgoings or as specified below. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. Following accessories :-
The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters/Push button/NO NC of contactor/Timers etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The Panel shall be provided with cast Resign CTs & LED indicating lamps at Incoming for RYB. The panel shall be provided with heavy duty ss cable glands of adequate size for incoming and all outgoing cables. The single line circuit diagram showing the arrangements of circuit inside the distribution board shall be provided inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided wall mounting arrangement as per site requirement. MCCBs shall be provided with spreader links with phase separators on both sided and suitable for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not be less than 900mmx200mmx900mm (LxDxH). The panel shall be provided with and including
Note : (a) The panel shall be fitted on wall with adequate size of fasterners and if existing surface is damged during installation of the panel the contratcor shall make it good with at his own cost. (b)Drawing and design of control Panels, busbar size shall be approved by Engr- in-charge before manufacturing of the Panel. a) Aluminium bus bars 200 amps, 50KA rating suitable for 3 phase 4 wire system b) Incoming MCCB 4P 100 amps, 36 KA breaking capacity with adjustable short circuit setting from 1.5 -12 x Ir or 1.5-12 x In and adjustable magnetic overload protection with setting 0.25 - 1.0 x In, Ics =100% of Icu - 01 Nos Make- L&T/Legrand/Schnider d) Outgoing 3 Pole Power contactor, 50Hz, 415V, AC3 type MO 18 with Aux contactos 1 NO + 1 NC conforms to IS/IEC 60947-4-1 including its push button for on/off, Indication Lamp of ON position for each contactor Nos - 2 , Make- L&T/Legrand/Schnider
e) Outgoing 3 Pole Power contactor, 50Hz, 415V, AC3 type MO 12 with Aux contactos 1 NO + 1 NC conforms to IS/IEC 60947-4-1 including its push button for on/off, Indication Lamp of ON position for each contactor Nos - 1 Make- L&T/Legrand/Schnider f) Outgoing Electronic Protection Relay 0.15 to 12 type REO 1.1G - Direct Mounting on MO Contactor with protections: Overload, Single phasing, Phase unbalance, Locked rotor, Earth fault, Trip Indication etc Nos - 3 Make- L&T/Legrand/Schnider g) outgoing MCB 6- 32A ,B curve, Three Pole Nos -3 Make- L&T/Legrand/Schnider h) outgoing MCB 63A ,B curve, Double Pole Nos -3 (For each phase 1), and MCB 20 A DP B curve DP Nos- 9 (for each phase 3) including DP copper busbar/short link with end caps, MCB mounting arrangement etc Make- L&T/Legrand/Schnider j) Multifunction Meter LED ,Accuracy Class 1, with RS 485 Parameters V,A,F,PF,kW,kVA, kVAR,kWh,kVAh,kVARh, Runhours,On Hours,Phase angle,Interrupts,THD,Events(High-Low), Neutral Current Nos-1
Supply & fix control panel weather proof Indoor type single door with wall mounting arrangement, fabricated out of 2 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated as per CPRI norms only. The Panel shall be design totally enclosed, dust and vermin proof, conforming to degree of protection IP-53, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, electrolytic grade after Incoming MCCB and Copper PVC cables of adequate rating for all outgoings or as specified below. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment.
The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters/Push button/NO NC of contactor/Timers etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The Panel shall be provided with cast Resign CTs & LED indicating lamps at Incoming for RYB. The panel shall be provided with heavy duty ss cable glands of adequate size for incoming and all outgoing cables. The single line circuit diagram showing the arrangements of circuit inside the distribution board shall be provided inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided wall mounting arranegment as per site requirement. MCCBs shall be provided with spreader links with phase separators on both sided and suitable for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not be less than 1000mmx200mmx1200mm (LxDxH). The panel shall be provided with and including following accessories :- Note : (a) The panel shall be fitted on wall with adequate size of fasterners and if existing surface is damged during installation of the panel the contratcor shall make it good with at his own cost. (b)Drawing and design of control Panels, busbar size shall be approved by Engr- in-charge before manufacturing of the Panel. a) Aluminium bus bars 200 amps, 50KA rating suitable for 3 phase 4 wire system
b) Incoming MCCB 4P 100 amps, 36 KA breaking capacity with adjustable short circuit setting from 1.5 -12 x Ir or 1.5-12 x In and adjustable magnetic overload protection with setting 0.25 - 1.0 x In, Ics =100% of Icu Nos -01 Make- L&T/Legrand/Schnider c) Outgoing 3 Pole Power contactor, 50Hz, 415V, AC3 type MO 12 with Aux contactos 1 NO + 1 NC conforms to IS/IEC 60947-4-1 including by pass switch to each contactor Nos - 6, Digital Timer Nos -01 Make- L&T/Legrand/Schnider d) Outgoing Electronic Protection Relay 0.15 to 12 type REO 1.1G - Direct Mounting on MO Contactor with protections: Overload, Single phasing, Phase unbalance, Locked rotor, Earth fault, Trip Indication etc Nos - 6 Make- L&T/Legrand/Schnider e) outgoing MCB 6- 32A ,B curve, Three Pole Nos -10 Make- L&T/Legrand/Schnider f) outgoing MCB 63A ,B curve, Double Pole Nos -3 (For each phase 1), and MCB 20 A DP B curve DP Nos- 9 (for each phase 3) including DP copper busbar/short link with end caps, MCB mounting arrangement etc Make- L&T/Legrand/Schnider g) Multifunction Meter LED ,Accuracy Class 1, with RS 485 Parameters V,A,F,PF,kW,kVA,kVAR,kWh,kVAh,kVARh,Runhours,On Hours,Phase angle,Interrupts,THD,Events(High-Low), Neutral Current Nos-1
Supply & fix control panel weather proof Indoor type Single door with wall mounting arrangement, fabricated out of 2 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated as per CPRI norms only. The Panel shall be design totally enclosed, dust and vermin proof, conforming to degree of protection IP-53, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, electrolytic grade after Incoming MCCB and Copper PVC cables of adequate rating for all outgoings or as specified below. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment.
The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters/Push button/NO NC of contactor/Timers etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The Panel shall be provided with cast Resign CTs & LED indicating lamps at Incoming for RYB. The panel shall be provided with heavy duty ss cable glands of adequate size for incoming and all outgoing cables. The single line circuit diagram showing the arrangements of circuit inside the distribution board shall be provided inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided wall mounting arranegment as per site requirement. MCCBs shall be provided with spreader links with phase separators on both sided and suitable for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not be less than 600mmx200mmx600mm (LxDxH). The panel shall be provided with and including following accessories :-
Note : (a) The panel shall be fitted on wall with adequate size of fasterners and if existing surface is damged during installation of the panel the contratcor shall make it good with at his own cost. (b)Drawing and design of control Panels, busbar size shall be approved by Engr- in-charge before manufacturing of the Panel. a) Aluminium bus bars 100 amps, 50KA rating suitable for 3 phase 4 wire system b) Incoming MCCB 4P 40 amps, 36 KA breaking capacity with adjustable short circuit setting from 1.5 -12 x Ir or 1.5-12 x In and adjustable magnetic overload protection with setting 0.25 - 1.0 x In, Ics =100% of Icu Nos -01 Make- L&T/Legrand/Schnider c) Outgoing 3 Pole Power contactor, 50Hz, 415V, AC3 type MO 12 with Aux contactos 1 NO + 1 NC conforms to IS/IEC 60947-4-1 including bypass switch to each contactor, Indication Lamp of ON position for each contactor Nos - 2, Digital Timer Nos -01 Make- L&T/Legrand/Schnider d) Outgoing Electronic Protection Relay 0.15 to 12 type REO 1.1G - Direct Mounting on MO Contactor with protections: Overload, Single phasing, Phase unbalance, Locked rotor, Earth fault, Trip Indication etc Nos - 2 Make- L&T/Legrand/Schnider e) outgoing MCB 6- 32A ,B curve, Three Pole Nos -2 Make- L&T/Legrand/Schnider f) outgoing MCB 63A ,B curve, Double Pole Nos -1 , and MCB 20 A DP B curve DP Nos- 3 including DP copper busbar/short link with end caps, MCB mounting arrangement etc Make- L&T/Legrand/Schnider
Supply & fix control panel weather proof Indoor type single door with wall mounting arrangement, fabricated out of 2 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated as per CPRI norms only. The Panel shall be design totally enclosed, dust and vermin proof, conforming to degree of protection IP-53, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, electrolytic grade after Incoming MCCB and Copper PVC cables of adequate rating for all outgoings or as specified below. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment.
The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters/Push button/NO NC of contactor/Timers etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The Panel shall be provided with cast Resign CTs & LED indicating lamps at Incoming for RYB. The panel shall be provided with heavy duty ss cable glands of adequate size for incoming and all outgoing cables. The single line circuit diagram showing the arrangements of circuit inside the distribution board shall be provided inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided wall mounting arranegment as per site requirement. MCCBs shall be provided with spreader links with phase separators on both sided and suitable for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not be less than 300mmx200mmx300mm (LxDxH). The panel shall be provided with and including following accessories :-
Note : (a) The panel shall be fitted on wall with adequate size of fasterners and if existing surface is damged during installation of the panel the contratcor shall make it good with at his own cost. (b)Drawing and design of control Panels, busbar size shall be approved by Engr- in-charge before manufacturing of the Panel. a) Aluminium bus bars 100 amps, 50KA rating suitable for 3 phase 4 wire system b) Incoming MCCB 4P 40 amps, 36 KA breaking capacity with adjustable short circuit setting from 1.5 -12 x Ir or 1.5-12 x In and adjustable magnetic overload protection with setting 0.25 - 1.0 x In, Ics =100% of Icu Nos -01 Make- L&T/Legrand/Schnider c) Outgoing 3 Pole Power contactor, 50Hz, 415V, AC3 type MO 12 with Aux contactos 1 NO + 1 NC conforms to IS/IEC 60947-4-1 including bypass switch to each contactor, Indication Lamp of ON position for each contactor Nos - 1, Digital Timer Nos -01 Make- L&T/Legrand/Schnider d) Outgoing Electronic Protection Relay 0.15 to 12 type REO 1.1G - Direct Mounting on MO Contactor with protections: Overload, Single phasing, Phase unbalance, Locked rotor, Earth fault, Trip Indication etc Nos - 1 Make- L&T/Legrand/Schnider
S & F in replacement Timer panel weather proof indoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-53, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, shall not be less than 150mmX20mmX5mm( L x W x thickness) electrolytic grade of adequate rating, . The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided wall mounting arrangement. The overall size of the panel shall not be less than 300mmx200mmx300mm (LxWxH).including earthwork all as directed and specified including follwing Acessories:-
a) Incoming MCB 4P 63 amps Nos -01 Make- L&T/Legrand/Schnider b) Outgoing 3 Pole Power contactor, 50Hz, 415V, AC3 type MO 18 with Aux contactos 1 NO + 1 NC conforms to IS/IEC 60947-4-1 including bypass switch, Indication Lamp of ON position Nos - 1, Digital Timer Nos -01 Make- L&T/Legrand/Schnider c) Outgoing Electronic Protection Relay 0.15 to 12 type REO 1.1G - Direct Mounting on MO Contactor with protections: Overload, Single phasing, Phase unbalance, Locked rotor, Earth fault, Trip Indication etc Nos - 1 , MCB TP 6 to 32 Amp Nos- 3 Make- L&T/Legrand/Schnider
M&L for replacement of earthing complete with galvanised steel earth plate electrode 60x60cmx6.3mm GI thick burried directly in ground ( earth plate pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 40 mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 32x6mm galvanised iron strip and it shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent sag complete all as specified and directed.
Supply & fix control panel weather proof Indoor type single door with wall mounting arrangement, fabricated out of 2 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated as per CPRI norms only. The Panel shall be design totally enclosed, dust and vermin proof, conforming to degree of protection IP-53, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, electrolytic grade after Incoming MCCB and Copper PVC cables of adequate rating for all outgoings or as specified below. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment.
The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters/Push button/NO NC of contactor/Timers etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The Panel shall be provided with cast Resign CTs & LED indicating lamps at Incoming for RYB. The panel shall be provided with heavy duty ss cable glands of adequate size for incoming and all outgoing cables. The single line circuit diagram showing the arrangements of circuit inside the distribution board shall be provided inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided wall/angle iron mounting arranegment as per site requirement. MCCBs shall be provided with spreader links with phase separators on both sided and suitable for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not be less than 800mmx250mmx900mm (LxDxH). The panel shall be provided with and including following accessories :-
Note : (a) The panel shall be fitted on wall with adequate size of fasterners and if existing surface is damged during installation of the panel the contratcor shall make it good with at his own cost. (b)Drawing and design of control Panels, busbar size shall be approved by Engr- in-charge before manufacturing of the Panel. a) Aluminium bus bars 300 amps, 50KA rating suitable for 3 phase 4 wire system (b) Incomer MCCB 4Pole, 160 AMP, 25 KA with adjustable over load setting .8 -1.0 x In and adjustable short circuit setting 6 -10 x In, Ics=100%Icu (Incomer) Nos - 1. (c) MCCB 4Pole , 100 AMP, 25 KA with adjustable over load setting .8-1.0 x In and adjustable short circuit setting 6 - 10 x In, Ics=100%Icu (Outgoing) Nos - 4.
Supply, laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated, screened and PVC shealhed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall with MS saddels etc complete of size 70 Sqmm 3.5 Core
S & F wire mesh Cable Tray Hot Dipped Galvanized 3Mtrs Length 54 X 200mm.Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the atandard IEC 61537.Wire cable trays must be designed with an optimum span of 1.5 m, taking into account the maximum carrying capacity authorised by the manufacturer. Assemblies with specific fire resistant properties must have an E30-E90 certificate. The loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537. It shall be manufactured with a longitudinal 'T- welded' safety edge.
M&L in replacement supports clamps and back plate fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one umder coat and one finishing coat of paint complete all as specified and directed by Engr-in-charge
M & L for Wiring for circuit/submain wiring in PVC conduit alongwith earth wire with the 2 x 6 Sqmm sizes and 1 x 6 Sqmm size earth conductor of FRLS PVC insulated copper conductor, single core cable multistranded in surface/recessed as required complete all as specified and directed
M &L for dismantling of tiles and refixing it after fixing of angle iron supports of surface wherever required and making good to match with existing surface.
M&L for plain concrete cement 1:3:6 type C2 using 40mm graded coarse aggregate for foundation of Panels etc including necessary form work and PCC Demoltion of any description and in any position.
S & F, testing & commsissioning RS 485 to Ethernet converter & wireless Transreciver module with supported Protocols i.e. MODBUS TCP,MODBUS RTU Over TCP,MODBUS ASCII Over TCP,MODBUS RTU, MODBUS ASCII, suitable to Operating Temperature -10 to 60 °C, Isolation:- 1.4kV RMS ,Ethernet :-10/100 Base-TX Network Feature :- 6 Remote Connection, Ability to Configure by the Web Interface, DHCP ,Automatic IP Receive ,ARP,Ping blocking Serial Communication:- Supports up to 25 Devices, Baudrate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, Stop Bit and Parity Bit Adjustment. having USB Ability to Configure over USB, Micro USB Connection Interface , including connection of control cables to Multifucntion meters and breakers complete all as specified and directed. Note : Converter should connect all RS485 terminals of multifunction meter and wireless Transreciver module shall be fixed at main incomer 22KV VCB breakers room to fetch required data from minimum 50 Mtr distance
Supply & fix Control panel weather proof indoor type single door, fabricated out of 2.00 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturere only. The Panel shall be dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with Wire Harness and connecting accessories for control system. The overall size of the panel shall not be less than 450mmx250mmx500mm (LxDxH). The panel shall be provided with and including following accessories :- (a) MICROCONTROLLER UNIT : SERIAL COMMUNICATION PORTS: (RS-232 and 1 RS-485). a 10 base T/100 Base-TX Ethernet port communicates with up to ten protocols simultaneously accepts one expansion communication module to add canopen, j1939, profibus, devicenet and more one usb device port to load the unit’s configuration or transfer data to and from a PC SD card socket for data logging and loading database in field power unit from 24 vdc supply built-in web server for remote access real-time data logging for alarm notifications via Email or SMS messages. Make :Advantech/Moxa/ Robustell or suitable to software/Hardware
(b) 16 Channel DI/DO,PLC DIGITAL DIO MODULE WITH ETHERNET:Built-in Web Server Support Modbus TCP/UDP Protocols, Powerful 32-bit MCU Handles Efficient Network Traffic , 2-port Ethernet Switch (LAN Bypass) for Daisy-Chain Wiring, Dual Watchdog, I/O Pair Connection (Push and Polling), Easy Firmware Update via Ethernet LED Indication I/O status, 16 channels of Universal DIO, Provide Digital Output Maximum Load Current ,ET-2254: 100 mA/Channel, ET-2254P: 400 mA/Channel, Bi-direction Universal DIO ports under software control, Wide Operating Temperature Range: -25 ~ +75°C Make : L&T/Siemens(Modl)/Rockwell Automation or suitable to software/Hardware (c) SMPS 24V/5AMP :ISOLATION Input – Output : 2.5KVAC, 1 minute Input – Earth : 2KVAC, 1 minute Output – Earth : 0.5KVAC, 1 minute EFFICIENCY 80 ~ 85% @ full load & Nominal input voltage O/P VOLTAGE ADJUSTMENT +/- 10% of nominal output voltage OVERLOAD PROTECTION 105% ~ 130% of rated load LINE & LOAD REGULATION Better than 0.5% HOLD UP TIME > 20ms at rated input voltage and load OPERATING AMBIENT 0 ~ 50oC, 95% RH STORAGE AMBIENT -20oC to 85oC SAFETY STANDARD Design refers to EN60950-1 EMC STANDARD Design refers to EN55022, EN55024 APPROVAL / MARK CE TERMINATIONS Screw type, for 2.5mm sq. wire MOUNTING 35 mm DIN rail
S & F GPRS/GSM sim card with 3 years internet recharge. Provider: Idea/Airtel/Vodaphone
S & F Magnetic base ANTENNA with 20 Mtr long wire DBI antenna for GSM FCT/GSM SMA FEMALE 900/1800/2300/2600 mhz FOR - GSM FCT,FWP,POS MACHINE,GSM module circuit
S& F 4G LT Modem :LTE-TDD B40/B41 LTE-FDD B1/B3/B5/B8 UMTS/HSPA+ B1/B8 GSM/GPRS/ EDGE B3/B8 Control Via AT Commands Supply voltage range: 24VDC Typical Operation temperature: -40°C to +85°C Dimension: 105*85*38mm
S & F Cloud service for 2 year to data transferring suitable to item No 7 and required trouble shooting related to data fetching complete all as specified and directed
S & fix testing, commssioning and installation of Software including prjoect development and installation of all accessories etc : Individual Login Page with Overall Information in single page including GroupWise Analytics, Electrical system Live view connected to software, ACB/VCB Breaker status i.e. On/OFF/Trip & remotely operation of RMU through software etc connected to software, MAP based view system, Real Time Feeder Information, History – chart and table based representation Reports for different systems [Excel export report] Email and SMS alerts, API for app based alerts (customizable) Automated Control command complete including fixing of GPRS communication gateway complete all as specified and directed. Make :ABB/SIEMENS(Modl)/L&T(Smartcomm)
S & F RS 485 cable for looping/daisy chain wiring of MF meters including fixing on wall in pvc casing caping and in panel in pvc flexible complete all as specified and directed. Make : Polycab/RR
Supply & fix Control panel weather proof indoor type single door, fabricated out of 2.00 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturere only. The Panel shall be dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with Wire Harness and connecting accessories for control system. The overall size of the panel shall not be less than 450mmx250mmx500mm (LxDxH). The panel shall be provided with and including following accessories :- (a) RS 485 to Ethernet converter module with supported Protocols Make :Advantech/Moxa/ Robustell or suitable to software/Hardware (b) MICROCONTROLLER UNIT : SERIAL COMMUNICATION PORTS: (RS-232 and 1 RS-485).
A 10 BASE T/100 BASE-TX ETHERNET PORT COMMUNICATES WITH UP TO TEN PROTOCOLS SIMULTANEOUSLY ACCEPTS ONE EXPANSION COMMUNICATION MODULE TO ADD CANOPEN, J1939, PROFIBUS, DEVICENET AND MORE ONE USB DEVICE PORT TO LOAD THE UNIT’S CONFIGURATION OR TRANSFER DATA TO AND FROM A PC SD CARD SOCKET FOR DATA LOGGING AND LOADING DATABASEIN FIELD POWER UNIT FROM 24 VDC SUPPLY BUILT-IN WEB SERVER FOR REMOTE ACCESS REAL-TIME DATA LOGGING FOR ALARM NOTIFICATIONS VIA EMAIL OR SMS MESSAGES Make :Advantech/Moxa/ Robustell or suitable to software/Hardware (c) 16 Channel DI/DO,PLC DIGITAL DIO MODULE WITH ETHERNET:Built-in Web Server Support Modbus TCP/UDP Protocols, Powerful 32-bit MCU Handles Efficient Network Traffic , 2-port Ethernet Switch (LAN Bypass) for Daisy-Chain Wiring, Dual Watchdog, I/O Pair Connection (Push and Polling), Easy Firmware Update via Ethernet LED Indication I/O status, 16 channels of Universal DIO, Provide Digital Output Maximum Load Current ,ET-2254: 100 mA/Channel, ET-2254P: 400 mA/Channel, Bi-direction Universal DIO ports under software control, Wide Operating Temperature Range: -25 ~ +75°C Make : L&T/Siemens(Modl)/Rockwell Automation or suitable to software/Hardware
(d) SMPS 24V/5AMP :ISOLATION Input – Output : 2.5KVAC, 1 minute Input – Earth : 2KVAC, 1 minute Output – Earth : 0.5KVAC, 1 minute EFFICIENCY 80 ~ 85% @ full load & Nominal input voltage O/P VOLTAGE ADJUSTMENT +/- 10% of nominal output voltage OVERLOAD PROTECTION 105% ~ 130% of rated load LINE & LOAD REGULATION Better than 0.5% HOLD UP TIME > 20ms at rated input voltage and load OPERATING AMBIENT 0 ~ 50oC, 95% RH STORAGE AMBIENT -20oC to 85oC SAFETY STANDARD Design refers to EN60950-1 EMC STANDARD Design refers to EN55022, EN55024 APPROVAL / MARK CE TERMINATIONS Screw type, for 2.5mm sq. wire MOUNTING 35 mm DIN rail Make: suitable to software/Hardware
S & F Wiring for circuit/submain wiring alongwith earth wire including PVC casing capping with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required 2x1.5 sq. mm + 1x1.5 sq. mm earth wire.
SONU ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .