Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.7 LAccepted-AOC | L-1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L-2₹13.2 L+₹51,410 (4.05%)Rejected-Finance | L-2 | Rejected-Finance Other Than Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
20 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Umroi
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
REPAIR REPLACEMNT OF RCC TANKS BY PVC TANKS AND ALLIED WORKS IN OLD JCOS/OR QTRS AT UMROI MIL STN UNDER GE UMROI
2022_MES_532955_1
8625/E8
Open Tender
Civil Works
Item Rate
150 days
Umroi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Umroi
₹30,000
25 Jul 2022
23 Jun 2022
21 Jul 2022
23 Jun 2022
20 Jul 2022
6 Jul 2022
60 days
Amount
Taking up or down GI tubing 15/20mm bore from wall/ceilings including all fittings segrated and stacking the pipe, complete all as specified and directed.
S&F for CPVC pipes of 20 mm outside dia, SDR 11 and plainf CPVC SDR 11 fittings on walls/ ceiling or laying in wall/ceiling or laying in floors complete all as specified
Supply & Fixing 3-layer PP-R Polypropylene random copolymer) of 20 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. with all fittings and fixed complete to wall and ceiling or laid in floors and making connection with old GI tube/PPR pipe using suitable section complete leakproof all as specified and as directed.
Cutting chases for concealed pipe where required and pointing in cement mortar 1:3 etc. in Brick walls for bore of pipe 15/20 mm complete all as directed.
Demolition of RCC with concrete cutter machine of any description and in any position not otherwise specifically provided for including taking out and seperating old reinforcement and removal of debries to a distance not exc 50m as directed by Engineer in charge and making site clean complete all as specified and directed.
Supply and fix of rotational moulded,multilayer HDPE water storage tank of 500 ltrs capacity( tripple layer wall construction , Cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed
Supply and fix of rotational moulded,multilayer HDPE water storage tank of 1000 ltrs capacity( tripple layer wall construction , Cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
Supply & fix 20 mm bore gun metal, glove or gate valves ISI marked with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F for stop valves fancy type chromimum plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe CPVC pipe or for union and of size 15 mm bore complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends,swan necks etc.including cleaning or refixing or removal to store, complete all as specified and as directed
Supply & Fix 3 mm thick Square/half round 6" to 8" perimeter color coated UPVC rain water gutter for rain water draining in bldgs (Single,double & triple story) including (drop outlet) runner drop,elbow drop,clamps etc all including attached downpout of suitable size fitting fixture discharging storm water into PVC SWR pipe of 110 mm dia and similar works height upto three story building etc complete all as specified and directed. Note: The rate shall be inclusive Scaffolding
Supply & fix PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls 110mm bore, complete all as specified and directed.
Supply & Fix 110mm bore PVC (SWR) bends any radius all as specified & directed.
Supply & Fix 110mm bore PVC (SWR) branch pieces, single 'Y' , equal or unequal all as specified & directed.
Supply & Fix 110mm bore PVC (SWR) junction single, (single T) equal or unequal all as specified & directed.
Supply & fix PVC (SWR) bends any radius 110mm bore, complete all as specified and directed.
Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e) Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left for air cure for min Seven days (without any movement). Make : - STP ShaliCryl LM or Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof , FOSROC or SIKA or as equivalent approved by GE. Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) Product should confirm ASTMD-6083 (iv) The work shall be executed through Authorised well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
Dismantling of plain/corrugated steel sheeting, any gauge or thickness including Nainital, Shimla pattern roof covering, complete all as specified and directed.
Supply & fix of Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ridge/ cladding to wall, fixed with self tapping screw (Heavy duty) with in built washers and neoprene & EDPM washers, in roofs, walls etc complete all as specified and directed.
S&F for 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugateion side lap fixed with L type or J type or cranked hook bolts in lieu of screw.
Supply & fix 0.50 mm thick prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding as wall, fixeed with self tapping screws as specified.and directed
Schedule of Credit
N.V.ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .