Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.7 L+₹1.9 L (6.90%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹29.2 L+₹2.3 L (8.55%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹29.4 L+₹2.6 L (9.49%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹29.7 L+₹2.8 L (10.4%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
11 Dec 2025, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
REPAIR/ REPLACEMENT OF UNSV PARTS OF COLD ROOM DUCTABLE ACs AND CONNECTED MISC E/M WORKS AT BASE HOSP AFTC AND AFMSD UNDER GE (EAST) DELHI CANTT-10
2025_MES_740724_1
GE/DE-113/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Cat c (i)/ Class D
9 documents required · 9 mandatory
₹500
GE (EAST) DELHI CANTT-10
₹90,000
Yes
27 Jan 2026
20 Nov 2025
13 Dec 2025
20 Nov 2025
11 Dec 2025
4 Dec 2025
Amount
S&F in replacement Controller Suitable for Cold Chamber of any make and model, complete all as specified and as directed.
S&F in replacement of IDU axial fan complete Set, suitable for cold chamber (Model No-RAUH0-2012 KP-I). Make: Blue Star/ Carrier/ Ice Make.
S&F in replacement of IDU axial fan complete Set, suitable for cold chamber (Model No RAUH0-1015 KP-I). Make: Blue Star/ Carrier/ Ice Make.
S&F in replacement of IDU axial fan complete Set, suitable for cold chamber (Model No RAUH0-1012 KP-I). Make: Blue Star/ Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chamber (Model No RUAH0-2012 KP-O). Make: Blue Star/ Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chambers (Model No RUAH0-1015 KP-O). Make: Blue Star/ Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chambers (Model No RUAH0-1012 KP-O). Make: Blue Star / Carrier/ Ice Make.
S&F in replacement of ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-2012 KP-O). Make: Blue Star/ Carrier/ Ice Make.
S&F in replacement of ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-1015 KP-O). Make: Blue Star/ Carrier/ Ice Make.
S&F in replacement of ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-1012 KP-O). Make: Blue Star/ Carrier/ Ice Make.
S & F in replacement Compressor working on 230 Volt, AC, single phase complete duly filled with capila 'D' including supply and charging the refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for outer door unit 40000 BTU/Hour ( Cold chamber Model No- RUAH04012KP-O). Make: Blue Star/ Emerson Copeland/ Danfoss
S & F in replacement Compressor working on 230 Volt, AC, single phase complete duly filled with capila 'D' including supply and charging the refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for outer door unit 20000 BTU/Hour ( Cold chamber Model No- RUAH0-2012 KP-O). Make - Blue Star/ Danfoss/ Emerson Copeland.
S & F in replacement Compressor working on 230 Volt, AC, single phase complete duly filled with capila 'D' including supply and charging the refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chambersuitable for outer door unit 15000 BTU/Hour ( Cold chamber Model No- RUAH01015KP-O). Make: Blue Star/ Emerson Copeland/ Danfoss
S & F in replacement Compressor working on 230 Volt, AC, single phase complete duly filled with capila 'D' including supply and charging the refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for outer door unit 10000 BTU/Hour ( Cold chamber Model No- RUAH01012KP-O). Make: Blue Star/ Emerson Copeland/ Danfoss
S&F in replacement of Evaporator Coil suitable for cold chamber (Model No RUAH0-2012 KP-I). Make : Blue Star /Carrier/ Ice make.
S&F in replacement of Evaporator Coil suitable for cold chamber (Model No RUAH0-1015 KP-I). Make : Blue Star/ Carrier/ Ice make.
S&F in replacement of Evaporator Coil suitable for cold chamber (Model No RUAH0-1012 KP-I). Make : Blue Star/ Carrier /Ice make.
S&F in replacement of Condenser Coil, Size 24 inch and 2 Row suitable for cold chamber (Model No RUAH0-2012 KP-O). Make : Blue Star/ Carrier/ Ice make.
S&F in replacement of Condenser Coil, Size 24 inch and 2 Row suitable for cold chamber (Model No RUAH0-1015 KP-O). Make : Blue Star/ Carrier/ Ice make.
S&F in replacement of Condenser Coil, Size 24 inch and 2 Rowsuitable for cold chamber (Model No RUAH0-1012KP-O). Make : Blue Star/ Carrier/ Ice make.
S&F in replacement Service Valve 7/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in replacement Service Valve 5/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in replacement Service Valve 6/8'' suitable for ductable Ac/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in replacement Service Valve 3/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in replacement Service Valve 1/2'' , 1/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and as directed. Make : Blue Star/ Carrier/ Ice make.
S&F in replacement copper tubing 7/8" dia & wall thickness- 20 SWG with required insulation complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S&F in replacement copper tubing 6/8" dia & wall thickness- 22 SWG with required insulation complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S&F in replacement copper tubing 5/8" dia & wall thickness-20 SWG with required insulation as per site requirement complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S&F in replacement copper tubing 3/8" dia & wall thickness- 16 SWG with required insulation complete all as specified and as directed. Make: Totaline/ Godrej or equivalent.
S & F in replacement copper tubing ½” dia & wall thickness - 22 SWG with required insulation complete all as specified & as directed.
S & F in replacement copper tubing 1/4” dia & wall thickness - 22 SWG with required insulation complete all as specified & as directed.
Supply and charging of refrigerant gas R-22, of suitable grade after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and as directed.
Supply and charging of refrigerant gas of suitable grade R-407C after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and as directed.
Supply and charging of refrigerant gas of suitable grade R-410 after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and as directed.
S&F in replacement strainer 3/8" for cold chamber of suitable size and make as per existing site complete all as specified and as directed. Make-Blue Star/Carrier/ Ice make.
S&F in replacement strainer 5/8" for cold chamber of suitable size and make as per existing site complete all as specified and as directed. Make-Blue Star/Carrier/ Ice make.
S&F in replacement watch timer switch single phase 2400 Hrs, 16 Amps for cold chamber including necessary wiring complete all as specified and as directed. Make : L&T/GIC(FM1 series) or equivalent.
S&F in replacement expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and as directed. (Model No. RUAHO-1012 KP-1) Make- Danfoss/Indfoss/Sporlon/Alco.
S&F in replacement expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and as directed. (Model No. RUAHO-1015 KP-1) Make- Danfoss/Indfoss/Sporlon/Alco.
S&F in replacement expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and as directed. (Model No. RUAHO-2012 KP-1) Make- Danfoss/Indfoss/Sporlon/Alco.
M&L for servicing, and cleaning of condenser/evaporator of out door and indoor unit of cold chamber respectively with suitable chemical, detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes , fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including top up of refrigerant Gas complete all as specified and as directed.
Attending the break down/ complaint of all nature including wiring of panels and all others mentioned below for walk in cooler of base hospital and carry out the required repairs, on all days including Sunday and holidays complete all as specified and as directed. Note- (i)The spare parts required to be replaced shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii) Adequate resources (Minimum one skilled refrigerator mech with helper) shall be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended within 06 Hour failing which a damage of Rs 1000/- per day per complaint shall be made from contractor dues.
S&F in replacement single phase preventer VSP-II complete all as specified and as directed. Make: Minilac/Siemens/L&T
S&F in replacement running capacitor 50 + 5 MFD complete all as specified and as directed.
M&L for servicing and cleaning of condenser/evaporator of out door and indoor unit of ductable AC respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including top up of refrigerant Gas complete all as specified and as directed.
Attending the break down/ complaint of all nature including wiring of DB for ductable AC of base hospital and carry out the required repairs, on all days including Sunday and holidays complete all as specified and as directed. Note- (i)The spare parts required to be replaced shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii) Adequate resources will be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended within 06 Hour failing which a recovery of Rs 1000/- per day per complaint shall be made from contractor dues.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for out door unit of ductable AC of cap 8.5 TR (102000 BTU/HR), (Ductable AC Model No- DSA1021R3-OA). Make - Blue Star / Danfoss/Emerson Copeland.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for out door unit of ductable AC of cap 8.75 TR (102000 BTU/HR), (Ductable AC Model No- ACDCUSC-875DGR407IM). Make - Blue Star / Danfoss/Emerson Copeland.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chambersuitable for out door unit of ductable AC of cap 8.5 TR (102000 BTU/HR), (Ductable AC Model No- DSA1021R2-OT). Make - Blue Star / Danfoss/Emerson Copeland.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for out door unit of ductable AC of cap 5.5 TR (66000 BTU/HR) ( Ductable ac Model No- DSA661R3-OA). Make - Blue Star / Danfoss/Emerson Copeland.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for out door unit of ductable AC of cap 5.5 TR (66000 BTU/HR) ( Ductable ac Model No- DSA661R2-O ). Make - Blue Star / Danfoss/Emerson Copeland.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber suitable for out door unit of ductable AC of cap 3 TR (9000 BTU/HR), ( Ductable ac Model No- DSA361R2-O). Make - Blue Star / Danfoss/Emerson Copeland.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber compressor of Capacity 2 TR working on 230 V, AC, single phase (Ductable AC Model No - DSA522R3-O) complete all as specified and as directed.
S&F in replacement of Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
AS&F in replacement of fan Motor of single Phase, 230V, Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan blade Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan blade Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan blade suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan blade suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan blade Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Outdoor Unit Fan blade Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of ODU fan blade Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Indoor unit blower Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement indoor Unit blower Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement Indoor Unit blower Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement Indoor Unit blower Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement Indoor Unit blower Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement Indoor Unit blower Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement Indoor unit blower Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Indoor unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Indoor Unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Indoor Unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Indoor unit blower Motor of 1 Phase, 230V, Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Expansion valve Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Expansion valve Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Expansion valve Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Expansion valve Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Expansion valve Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Expansion valve Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Expansion valve Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Evaporative coil Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Evaporative coil Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Evaporative coil Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Evaporative coil Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Evaporative coil Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Evaporative coil Suitable for ductable AC (Model No - DSA661R2-O ). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Evaporative coil Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Condenser coil Suitable for ductable AC (Model No - DSA1021R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Condenser coil Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Condenser coil Suitable for ductable AC (Model No - DSA1021R2-OT). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Condenser coil Suitable for ductable AC (Model No -DSA661R3-OA). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Condenser coil Suitable for ductable AC (Model No-DSA361R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Condenser coil Suitable for ductable AC (Model No - DSA661R2-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of Condenser coil Suitable for ductable AC (Model No DSA522R3-O). Make: Blue Star /Carrier/ Ice Make.
S&F in replacement of gas filter/ dryer 5/8" suitable for ductable AC of any make and model complete all as specified and as directed.
S&F in replacement of PCB for IDU suitable for ductable AC of any make and model complete all as specified and as directed.
S&F in replacement of capillary thermostat for controlling temperature complete all as specified and as directed.
M&L for servicing and cleaning of York mortury Chamber for capacity of 6 body respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including replacement of unserviciceable parts, top up of refrigerant Gas complete all as specified and as directed.
S&F in replacement of PCB for mortury chamber complete all as specified and directed.
S&F in replacement of Capacitor for mortury chamber complete all as specified and directed.
S&F in replacement of display unit for mortury chamber complete all as specified and directed.
S&F in replacement of Door handle for mortury chamber complete all as specified and directed.
S&F in replacement of Door gaskit for mortury chamber complete all as specified and directed.
S&F in replacement of tray wheel for mortury chamber complete all as specified and directed.
M&L for detecing of gas leakage in coil by nitrogen testing and charging fresh Gas as required by OEM and repairing lekage by brazing method complete all as specified and directed. Note: Cost of refrigerant shall be demand to be included in the quoted rate. No extra payment shall be made on this account.
Supply, Installing & testing and commissioning factory made and tested (CPRI test certified) LT panel, Indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 400 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 43 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 10 Sqmm. PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engr-in-charge, The scope of work includes the following :
Supply, Installing & testing and commissioning factory made and tested (CPRI test certified) LT panel, Indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 600 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 43 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 16 Sqmm. The scope of work includes the following :
S&F in replacement Absolute HEPA filter of size 830x550x70 mm B.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Absolute HEPA filter of size 550x540x70 mm B.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Absolute HEPA filter of size 915x610x70 mm F.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement Absolute HEPA filter of size 610x610x70 mm B.T. having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete
S&F in replacement of hepa filter screen complete all as specified and directed.
Hepa filter testing : OT validation as per NABH by using aerosol generator, photometer, particle counter, digital anemometer, differential pressure meter & thermo hygrometer and following test carried out : Hepa/ ULPA filter air velocity test Particle count test DOP test Room differential pressure test Temp & RH test complete all as specified and directed by Engr in charge. Note : Third party cetificate required for above test and submit this office for record purpose.
RUCHIKA ENGG.WORKS (BID ID -3490482)
Iconic Engineers (BID ID -3495508)
Singh Associates (BID ID -3496042)
sheetal engineering (BID ID -3501674)
SANJEEV ENTERPRISES (BID ID -3490979)
Flint India (BID ID -3495212)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tender113.pdf
Tender Documents • 1.26 MB
BOQ_829433.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .