Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC Lowest tender accepted | |
| 2 | L2₹8.7 L+₹1.4 L (19.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
6 Sept 2022, 6:00 pmClosed
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR AND MAINT OF INTERNAL WIRING INCL FITTING FIXTURE AND OTHER CONNECTED WORK IN 4 AREA UNDER GE AF ADM AREA AGRA
2022_MES_544513_1
8000-1979/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
Cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹20,000
Yes
3 Oct 2022
10 Aug 2022
8 Sept 2022
10 Aug 2022
6 Sept 2022
25 Aug 2022
10 Aug 2022 - 22 Aug 2022
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
M&L for point wiring complete for one light/fan/ exhaust fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anodised pressed steel concealed terminal switch boxes not less than 2 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.
All as per item No. 02 above but for One bell/ buzzer point on an independent board controlled by one bell push
All as per item No. 02 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per item No. 02 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per Item No 02 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm.
M&L for point wiring complete with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 2.50 sqmm nominal cross sectional area single core drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, complete including 2.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 5/6 Amp 230 Volts complete all as specified and directed.
S&F bell push, flush type, single pole, one way 5/6 Amp, 230 volt flush type complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, 2 in 1, 5 pin 5/6 Amp, 230 volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 6 pin 15/16 Amp, 230 volts complete all as specified and directed.
S&F call bell, ding dong type, AC single pole, 230 volt complete all as specified and directed.
S&F Lamp holder/ angle holder PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body, surface bakelite sheet 63.50 mm dia complete all as specified and directed.
S&F ceiling fan regulator, electronic, socket type, 5 speed 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed.
S&F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- Power factor should not be less thtn 0.95 Make- Havells Cat part No- LUMILINE+BS20WLED865SPCSS , ORIENT Cat part No-LBLN-20-C-AL /Phlips Cat part No- BN021C LED22S PSU CW GR
S&F in replacement of old U/S tube light fitting with energy saving decorative batten type 10 watt energy efficient tube light fitting (2 Feet) highly durable surface mounted LED batten constructed of fire retardent engineering grade extruded plastic and decorative end caps with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Make- ORIENT Cat part No-LBLN-10-C-SQ/Phlips cat part- BN021LED12S6500PSUGR, Havells Cat part No- LUMILINE+ BS10WLED865SPCSS
S&F in replacement enery saving new generation LED 10 Watts, IP-65 bulk head luminarie with opal diffuser complete including making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Make :- ORIENT Cat part No-LIBHP-10-C /Phlips cat part- WT202W LED10S CW PSU S3 PC/ Havells Cat part No- RUGBY GENXFS 10WLED 865SSYMBOPC
S&F fixing 18 W LED tube with builtin driver complete all as specified and directed Make :- ORIENT Cat part No-LTXL-18-C, Phillps cat part No-MAS LEDTUBE 18W,865T8I-1800LM, Havells Cat part No- PHOTO NULTRAE2 .01213T8 SSTL 18WLED865SPC
S&F in replacement decorative wall light fitting including LED lamp complete all as specified and directed. Make:- Phlips Stylo wall light, Havells cat part No.- LHFHANDBTN1O007, Halonix cat part No.- HLWB-01-E27 .
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Make:- Orient cat part No-LTSAQ-36-C/ Phillps cat part No-RC380BLED36S-6500 G6 L60W60PSUOD /Havells Cat part No- VENUS NEOHE2X2R 36WLED830PIRSENSOR
M&L for replacement of existing unsv building security light fittings with LED street light fitting 18 Watts, come with in-built IR Sensor , IP-65 including making connections complete all as specified and directed. Make:Helonix Cat Ref LED SL HLSLD-09H-18-CWL-R01-IRSEN or equivalent in Orient/Havells
S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCB SPN 240 volts, 'C' curve of rating 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCB TPN 415 volts, 'C' curve of rating from 40 to 63 amps, 50 Hz with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts, 8 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection TPN 415 Volts, 4 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
M&L for removal of existing old unsv earthing complete and providing new earthing with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth work in any type of soil , removal of surplus soil to a distance n.exc 50 m and connecting, testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Dismantling of existing meter panel board removing existig energy meter keeping safe custody and Design ,Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 650X245), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparant Door foor meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE only . DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make . The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 04 nos in separate chamber with locking arrrangement. (a) Four pole MCCB 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incomming side - 01 No. (b) MCB DP 32 Amp 10 KA , C Curve - 4 Nos (To be connected with 4 Nos Meters) (c) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (d) Ten Nos terminal blocks provided for output supply. (e) MCCB/MCB Nos Operated by flip Cover
S&F in replacement MCCB 63 Amps 415 volts, 50 Hz, 4 pole 16 KA breaking capacity including providing thimbles for out going cable complete all as specified and directed.
S&F in replacement MCCB 100 Amps 415 volts, 50 Hz, 4 pole 16 KA breaking capacity including providing thimbles for out going cable complete all as specified and directed.
S&F in replacement of existing unsv/ broken bakellite sheet cover 3 mm thick of size 5"x5" all as required at site including cutting sheet for fixing switches/sockets, drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed..
S&F in replacement of existing unsv/ broken bakellite sheet cover 3 mm thick of size 7"x4" all as required at site including cutting sheet for fixing switches/sockets, drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed.
S&F in replacement sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F in replacement two way terminal block, 63 Amp, screw clamp including nut, bolt, washer etc. suitable for mounting in existing din rail complete all as directed.
Balaji Associate
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .