Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.6 LAccepted-AOC 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | L1 | Accepted-AOC being lowest bid | |
| 2 | L2₹68.6 L+₹1.3 L (1.97%)Rejected-Finance MINISTRY OF DEFENCE MES G | L2 | Rejected-Finance Being not lowest |
Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
11 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE RnD Secunderabad
CE RnD Opp Jubilee bus station Picket Secunderabad
ADDITION / ALTERATION TO BUILDING No 21 (NAI CELL) AT HEMRL SUTARWADI PUNE
2023_MES_578138_1
81371
Open Tender
Civil Works
Item Rate
180 days
Pashan pune
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE(I) RnD Pashan
₹1.4 L
Yes
23 Mar 2023
31 Jan 2023
15 Mar 2023
31 Jan 2023
11 Mar 2023
20 Feb 2023
Amount
Taking down chowkhats incl shutterrs (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4 sqm each complete all as specified and directed.
Taking down chowkhats incl shutterrs (without taking off shutters from the frame) n. exc 1.5 sqm each complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviveable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL) complete all as specified and directed.
30mm thick PCC type B-0 1:2:4 using 12.5mm graded aggregate as specified and directed.
15 mm thick screed bed in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
Light Shade Vitrified tiles 8-9 mm thick (square / rectangular) in floor area of each tile exceeding 0.36 sqm but n exc 0.42 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Light Shade Vitrified tiles 8-9mm thick dark shade (square / rectangular) in skirting/dado area of each tile exceeding 0.36 sqm but n exc 0.42 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Colured ceramic non skid tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 but not exceeding 0.38sqm of premium quality in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Coloured ceramic non skid tiles in skirting 7 to 8mm thick set and joined in neat cement slurry and pointed in cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
10mm thick backing coat in CM 1:3 on brick or concrete surfaces for fixing of wall tiles as in dado / skirting complete all as specified and directed.
Glazed, coloured (including designer tiles as approved by GE) ceramic tiles in verticle surface of size 300 x 450 x 7 to 8mm thick set and joined in neat cement slurry and pointed in cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Colured dark shade non skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 but not exceeding 0.18sqm & shall be of premium quality (B-IIA Grade) confirming to IS-13712, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
POP cornise moulding design all as directed.
Anodised aluminium snap grid frame work for false ceiling all as specified hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified perforated particle board / tiles 12mm thick for insulation and acoustic purposes, 60 x 60 cm in size, fixed frame work or with staples on snap grid all as specified and directed.
Dismantling water tanks of capacity 1000 ltr and removing from site.
Rotational moulded polyethylene water storage tanks (cylindrical verticla with closed top) hoised and fixed in position all as specified in SSR Part I of capacity 1000 ltrs complete all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical verticla with closed top) hoised and fixed in position all as specified in SSR Part I of capacity 500 ltrs complete all as specified and directed.
Taking down AC / CI / PVC down take pipe 160mm bore complete all as specified and directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore complete all as specified and directed.
Supply, installation, fixing and testing of 12 mm thick toughened glass door with and including necessary hardware fittings, all accessories, fittings, fixtures, door springs, etc of door size not exc 4.5 sqm complete as per manufacturer's specifications / instructions and directed. Make: Dorma or equivalent make as approved by GE.
Aluminium Powder coating section (minimum thickness of powder coating 50 micron) for door / window / ventilators / partition etc frames & shutters sliding or openable type including necessary joining cleats, hinges, tower bolts, handles, mullion glazing clips, rubber packing, anodised aluminium snap beading, screws, sliding track, roller etc complete of standard sections all as specified and as directed.
Stainless steel wire mesh 0.45 nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples complete all as directed.
4 mm thick Figured glass, pin head type and glazing in squares in exc 0.5 sq.m in each pane complete all as specified and directed.
Framed work such as grills, gratings, railing etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Factory made solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube wood grain printed PVC sheet used instead of palain colour sheet and edges will be printed to match with printed sheet all as specified and directed.
Factory Made Solid PVC Moulded Door Shutters with wood free EPS 28 to 30 mm thick (stile:), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Prelam / plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
105 x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete supplied and fixed all as specified and directed.
Factory made 35mm thick flush shutter solid core with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
Aluminium anodised handles cast type, 150mm long.
MS butt hinges 100 mm long, medium weight, cold rolled and fixed.
MS butt hinges 75 mm long, medium weight, cold rolled and fixed.
250mm aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified.
Aluminium anodised barrel tower bolt, 150 mm long of extruded sections and fixed.
140 mm size, floor door stopper of aluminium alloy body and tongue with hard drawn spring all as specified.
Preparation of new or perviously untreated wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer all as specified and directed.
Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
18-20mm green marble as in flooring, staircase for treads including and over backing coat 15mm thick cement mortor 1:4 including pointing with white cement using marble dust (1:2) with admixture of pigment to match with the shade of granite including semicircular nosing and all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations.
Dismantling stone slabs and tiles of any description or thickness laid beded and pointed in cement mortar in floors, aprons etc.
Granite slab 20mm thick over CM (1:3) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types as in urinal partition etc all as specified and directed.
Demolition of Brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars, etc complete all as specified and directed.
Brick work with fly ash modular bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified.
Taking down cement plaster on brick / concrete / stone surface including raking out joints, hacking for key scrubbing down with water including necessary scaffolding at any height complete all as specified and directed.
Rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finished even & smooth without using extra cement all as specified and as directed.
15mm thick rendering on brick work / block masonry in CM (1:4) in two layers 10 mm thick in first layer and 5 mm thick in second layer with water proofing compound finished even and smooth without using extra cement including necessary scaffolding at any height complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
15mm thick renedering on brick work masonry in CM (1:6) finished even and smooth without using extra cement complete all as specified.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 3mm thick wall care putty finish complete all as specified and as directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified.
Applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over new surfaces including necessary scaffolding at any height complete all as specified and directed.
Dismantling of existing old padding concrete of any thickness of existing water proofing treatment over the RCC slab other than beams, chajjas, staircase etc by chipping of with proper tools viz chiesel and with applying reasonable force so as to avoid any damage to existing RCC roof slab complete as directed.
40mm thick PCC 1:2:4 (type B0 using 12.5 mm graded aggregate) as in levelling / padding course on roof slab, chajjas, projections on similar surfaces existing with slope, kerbs, roundedor chamfered edges, making the surface even and smooth without using extra cement including liquid water proofing compound complete as specified and directed. Note: Liquid water proofing compound will be measured and paid seperately as supply only.
PCC 1:2:4, type B0 (using 12.5mm graded stone aggregate) as in benching, copings, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork, complete all as specified and directed.
Rendering 10 mm thick on green fair faces of concrete surface in cement mortar 1:3 for receiving the roof finishes with water proofing compound all as specified and directed. Note: WPC will be measured and paid separately.
Mechanical cleaning of surface to make it free from any bituminous residue / dirt, oil, Greece or similar material. Thereafter crack treatment by cutting open cracks and cleaning bitumen based sealent including application of Pu based primer all as directed.
Applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of epoxy primer @ 15 Kg per Sqm followed by two coats of polyurethene coating with 1.5 Kg per sqm in two coats etc complete per manufacturer specification and as directed as under: - Notes for Sl item Nos. 56 & 57: 1. Properties of Polyurethane based chemical shall confirm to following Technical Parameters:- (i) Highly Elastic and shall have crack bridging ability of upto 3mm as per AS NZ 4548 (ii) UV Resistance. (iii) Adhesion to concrete and shall resist 7 bars of hydrostatic pressure.
(iv) Tensile strength should not less than 2.0 N/sq.mm for free film & 60% solid content as per ASTM C 1250 (v) Elongation should not less than 300% as per ASTM D2370 (vi) Solid content by weight should not less than 60%. (vii) Air/water permeability BSEN 12390 AT 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0mm. (viii) Accelerated weathering (ASTM453) should Pass 1000 hours. (ix) Reaction to fire - non inflammable. 2. The work shall be executed thru auth applicator of manufecturer only. Contarctor has to provide manufecturer test certificates for the above mentioned technical parameters & PVs. 3. The conractor has to submit the guarntee for 10 Years against the water proofing treatment. Make: Bostic, Berger, Fosroc, sika, Asian.
M&L for cleaning of surface and removal of loose concrete and filling cracks with polymer modified mortar using SBR polymer. High build elastomer water proofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, smartcare PU magnum US membrane with an elongation of 550% and tensile strength of 2.5 N/mm2 as ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, no leakage upto 7 bars of water pressure as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying smartcare PU magnum or approved equivalent in two coats with a consumption of 1.5 Kg per SQM on a primer surface with smartcare primer etc, complete as per manufacturer specifications. Make: Asian paints / Bostik / Fosroc / Sika.
20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed in repairs all as specified and directed.
20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed in repairs all as specified and directed.
Bib taps, long shank, fancy type, 15mm bore of pipe, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete fixed in repairs all as specified and directed.
15mm CP fancy type stop valve, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs all as specified and directed.
PVC connection 15 mm size with PTMT nuts of length 450 mm complete fixed in repairs all as specified and directed.
Wash hand basin, Vitreous China oval shaped, first quality, white colour, of size 550mm x 400mm x 175mm, including cutting for and pinning in ends of brackets or erecting stand, with and including CI brackets, PVC flexible pipe with both side brass nuts to joint and 750mm long PVC waste pipe 32mm dia, CP waste coupling with long screwed shanks and fly nuts, fixed in repairs, complete all as specified and directed.
Supply only 32mm bore waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms, suitable for vitreous china wash basin.
10 Litres capacity flushing cistern PVC valveless, syphonic action type, flushing cestern, low level, white, with inlet, ball valve, float and handle including brackets complete fixed in repairs all as specified and directed.
Pillar taps, fancy type, 15mm bore of pipe cast copper alloy, chromium plated, screwed for iron pipe complete all as specified and directed.
Vitreous china wash down water closet pan (pedestal pattern), white including fixing bolts (excluding flushing cistern and flush pipe) add fixed in repairs including pan seat cover complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store.
S&F 15mm dia bore GI tubing medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laid in floor etc including necessary scaffolding at any height complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, and removing from site.
20mm dia bore GI tubing medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laid in floor including necessary scaffolding at any height complete all as specified and directed.
P' or 'S' trap 100 mm dia pipe.
MS stack clamps out of 50 mm x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof in repairs all as specified and directed.
PVC bends, 110mm bore.
Towel Rail 600mm long 20 mm dia brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight 190 gms) complete fixed in repairs all as specified and directed.
Vitreous China Urinal, Half stall type, white excluding flushing cistern, flush pipe and waste pipe) complete fixed in repairs all as specified and directed.
Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete fixed in repairs all as specified and directed.
Sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Push cock, CP Fancy type 15mm bore complete fixed in repairs all as specified and directed.
Supply only integral liquid WPC of approved make.
French polishing coats on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats complete all as specified and directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with and including chromium plated bracket guard and railing 60cm long complete fixed in repairs all as specified and directed.
Toilet paper holder of chromium plated fixed to walls with and including chromium plated brass screws complete fixed in repairs all as specified and directed. Make: Jaquar cat No. CAN-1153N.
Chromium plated health foucet 1.2metre long including holder fixed to wall complete fixed in repairs all as specified and directed. Make: Jaquar cat No. ALD-CHR-573.
Soap dish, any type, fixed to plugs with chromium plated brass screws complete fixed in repairs all as specified and directed. Make: Jaquar / Hindware / Parryware. Note: Model and design as approved by GE.
Complete removal of exisiting treatment on wall / ceiling surfaces and preparation of old wall surfaces by filling holes etc and applying two coats of acryalic weather proof exterior emulsion paint over a coat of exterior primer on walls including necessary scaffolding at any height complete all as specified and directed.
Complete removal of existing treatment (paint / distemper) on walls and over and including 3mm thick wall care putty finish applying two coat of distemper oil emulsion over a coat of alkali resistance primer on wall complete all as specified and directed.
Preparation of old ceiling surfaces and applying two coats of white wash complete.
75mm thick plain cement concrete type C-1, 1:3:6 using 20mm graged aggregate as in plinth protection all as specified and directed.
Cement concrete type B-1, 1:2:4 (20mm graded aggregate) 100 mm thick as in floor, hardstanding etc. complete all as specified and directed.
Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed.
Taking down and refixing in same position shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, including easing and repair works, complete all as specified and directed.
Prelaminated particle board 12 mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work complete all as specified and directed.
Collapsible steel gates top hung consisting of channel pickets, pivoted flat bars top and bottom runners brass handles etc as specified erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
RCC 1:2:4 type B1 (using 12.5mm graded crushed stone aggregate) in chajjas, slabs, fins, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc, complete all as specified and directed.
Form work to sides and soffits of chajjas, fins, roof projection, shelves including supports etc, to fair finished surface of concrete flat complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips including anchoring and welding at places as directed complete all as specified and directed.
Venetian blinds with design on inner face, verticle type made of fiber cloth fixed to wall with necessary aluminium brackets, screws etc including aluminium frame ropes, rollers etc as approved by GE and all as specified and directed. Make: Vista Levalor or Techno-commercially equivalent make as approved by GE.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and directed.
Hardcore of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and directed.
Removing excavated materials exc 1.5 km but n exc 5 km outside MD land depositing where directed.
Plain cement concrete 100 mm thick type D2 1:4:8 cement concrete using 40mm graded stone aggregate as in levelling course complete all as specified and directed.
Plain cement concrete type B1, 1:2:4 (20mm graded aggregate) 100 mm thick as in hardstanding all as specified and directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Precast cement concrete kerb blocks of any size, shape and finished using white cement and pigment of any colour grade M-30, set and jointed in CM 1:4 to match complete all as specified and directed. Note: Laying of kerb stone in alternate any two colours.
Excavation in trenches, not exc 1.50 m depth & n. exc 1.5m wide for foundation, etc or shafts, wells, cesspits, manhole, etc in n. exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Demolition & breaking up drain pipes (salt glazedware / AC / RCC) set in cement mortar, of any internal dia of pipe i.e. 150 mm all as specified and directed.
Demoliton of brick work or stone / boulder precast concrete block masonry built in cement morter and precast concrete block all as specified and directed by Engineer-in-Charge.
Demolition of concrete (unreinforced) in ground floors and pavings n exc 15cm thick (below or above ground level).
Demolition of concrete (reinforced) in ground floors and pavings n exc 15cm thick (below or above ground level).
Plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation, filling and mass concrete all as specified and directed.
Plain cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate as in concrete bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore RCC pipes all as specified and directed.
Precast concrete block masonry type C1 1:3:6 (20mm graded aggregate) with solid blocks exc 10cm in width and setting in cement mortor 1:4 complete all as specified and directed.
Plain cement concrete type B0 1:2:4 (12.5mm grded aggregate) an in coping, bed plates like incliding weathering, slightly rounding weathering, slightly rounded or chamfered angles and throughting all as specified and directed.
Reinforced concrete pipes, class NP2, laid and jointed complete with collars of dia 150 mm.
Returning filling in, including spreading, levelling, watering and well ramming in laye not exc 25cm in soft / loose soil.
Removing excavated material exc 250 mtr and upto 500mtr from the starting point in soil outside MD land.
15mm thick renedering on other than fair faces of brick work in CM (1:4) finished even and smooth without using extra cement but using integral water proofing compound @ 3% by weight of cement complete all as specified and directed by the Engineer-in-Charge. Note: Integral water proofing compund shall be measured and paid separtely.
Liquid water proofing compound.
RCC type B1 1:2:4 (using 20mm graded aggregate) as in landings, cover slabs for man holes etc and similar articles and with plain faces set in cement mortar (1:4).
Mild steel deformed TMT bars 10 mm dia and over cut to length bent to shape required, including cranking, hooping / hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia.
Demolition of brickwork of stone / boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles.
Excavation in trenches not exe 1.5m wide and not exe 1.5m wide and not exe 1.5m in depth and getting out in hard/dense soil complete all as specified.
PCC 1:3:6 type C2 using 40mm graded stone aggregate as in fondation filling and mass concrete complete all as specified and directed.
Walling of random rubble, uncoursed well bonded, bedded, solidly hearted stone masonary built in cement mortar 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing or face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses 20 mm deep in granite or trap stone.
Cement concrete in surface channel and drains in type B2 1:2:4 (40mm graded aggregate) complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on brick or stone or concrete surfaces finished even and fair without using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc.
600 mm bore Reinforced concrete pipes class NP2, laid and jointed complete with collars complete all as specified and directed.
PCC 1:3:6 type C2, 40mm graded aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 600 mm bore complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in laye not exc 25cm in soils.
Removing excavated material exc 250 mtr and upto 500mtr from the starting point in soil outside MD land.
Dismantling fencing wire mesh, any type
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground in natural ground.
Walling of random rubble, uncoursed stone masonary built in cement mortar 1:6 but except stone. Note: Stone obtained from Sl item Nos. 43, 108 & 122 shall be reused.
PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:3).
Providing, cement concrete in string, lacing courses and copings etc, rounded or chamfered on edges type C1 1:3:6 (20 mm graded aggregate).
MS joist, channel, angle, or tee sections, fixed independently, without connection plate, as in fencing post etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 290 grade E-165 complete all as specified and directed.
MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe-290 grade E-165 complete all as specified and as directed.
Supply only chain link fencing of size 50 x 50 x 3.15mm dia weight per sqm n. exe 4 kg all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire.
Mild steel angles, bars, flats etc as in supports for posts and struts in fencing including cutting tops to shape as directed,drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc.,) including all necessary drilling, bolting or riveting etc., and similar work conforming to fe 410-0 or Fe 310-O complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm & n exc 10cm long complete all as specified and directed.
Taking down carefully aluminium / copper point wiring complete (light, fan socket & power) including unserviceable fixtures and fittings such as switches ceilimg roses pendents regulators sockets light fittings etc complete removing material to store for keeping in safe custody for taking credit & making good disturbed wall / floor etc complete all as directed.
Point wiring with 1.5 sqmm size, PVC insulated, unsheathed 1100 volts grade, single core multi stranded copper conductor cable (FRLS) drawn into and including PVC conduit medium grade 20 mm dia with all fittings and accessories fixed concealed (including chase cutting in brick / stone masonry walls for fixing conduit and plastering the external surface and matching the same with existing surface) and sunk cast iron or pressed steel terminal boxes for mounting fittings like modular switches, sockets & fan regulators etc including one continuous run of PVC insulated (green colour) 1.5 sqmm size solid copper conductor cable earth wire and connected to earth dolly complete all as specified and directed for One light point / bell point controlled by one way switch. Note: Verticle PVC pipe should be concealed from ceiling to switch board all as requires at site.
All as per Sl item No. 149 above, but for one ceiling fan / exhaust Fan point controlled by one one way switch.
All as per Sl item No. 149 above, but for one socket point 5 Amps on same board.
All as per Sl item No. 149 above, but for one socket point 5 Amps on independent board.
All as per Sl item No. 149 above, but with 2.5 Sq mm PVC insulated cable and 2.5 sq mm as earth wire for 15 Amps socket outlet on independent board.
Switch piano modular type 6A/10A Amps capacity.
Switch piano modular type 16 Amps capacity.
Socket, outlet, 5 pin 6 Amps, surface modular type, 2 module.
Socket, outlet, 5 pin 6/16 Amps, surface modular type, 2 module.
Bell push, modular type 5/6 Amps complete all as specified and directed.
Fan regulator step down modular type, 2 module.
Modular white cover plate with frame 1 or 2 module complete all as specified and directed.
Modular white cover plate with frame 4 module complete all as specified and directed.
Modular white cover plate with frame 6 module complete all as specified and directed.
Modular white cover plate with frame 8 module complete all as specified and directed.
Modular metal flush box 1 or 2 module complete all as specified and directed.
Modular metal flush box 4 module complete all as specified and directed.
Modular metal flush box 6 module complete all as specified and directed.
Modular metal flush box 8 module complete all as specified and directed.
Lamp holder, PVC / polycarbonite type with back plate suitable for batten fittings.
Ceiling rose, surface bakelite, 65 x 50 mm, 3 terminals complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp suitable for 240 Volts complete all as specified and directed.
Ultra modern recess mounting luminaire with high performance LED 36 W, suitable for mounting with Armstrong / Grid ceiling. Make: Cat Part No. PLANO2X2PLR36WLED865S of Havells / Crompton Greaves / Philips.
LED tube light fitting 1X20 W, 4 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories, internally prewired & including up with twin core twisted flexible copper cable of suitable size all as specified and as directed. Make: Havells Cat Part No. LUMILINE+BS20WLED865SPCSS / Philips / Crompton Greaves.
LED tube light fitting 2 x 20 W, 4 feet long suspended type anodized aluminium extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories, internally prewired & including up with twin core twisted flexible copper cable of suitable size complete fixed in repairs all as specified and as directed. Note: LED tube 20W will be measured and paid seperately. Make: Havells Cat Part No. REGALBATTENT8UPTO2X22WSSBSWH / Philips / Crompton Greaves.
Ultra bright LED tubelight (single side connection) with very high efficacy & THD <15% best suited for installation in existing tubelight LED Regal batten 1 x 20W / 2 x 20W luminaire with G13 lamp holders to give glare free light all as specified and directed by Engineer-in-Charge. Make: Havells Cat Part No. PHOTONULTRAE2.01213T8SSTL20WLED865SPC / Philips / Crompton Greaves.
Double stiff pendents, comprising of galvanised steel or chromium plated brass bell mouth connectors 2 Nos. with back plate and 2 x 1.5 mtrs long parallel 20 mm dia galvanised or stove enamelled screwed steel conduit with two check nuts for fixing tubelight fitting and upto 1.5 metre long twin core 0.5 sq mm copper conductor flexible wire / cable complete all as specified and directed.
Calling bell "ding dong" type AC 230 volt single pole fixed over with and including PVC rectangular block of size 175 mm x 100 mm x 50mm with 3 mm thick plastic laminated sheet 3 mm thick fixed with brass screws and cup washers complete all as specified and directed.
New generation, post top, energy saving, enviromental friendly, long life aesthetically designed with symetrical light distribution, spun aluminium land scape luminair with high power LED's as light source of 15 W suitable for fixing in 50 mm dia GI pipe complete all as specified and directed. Make: Havells Cat Part No. RUBYMINIPT15WLED757PSYMTOPC / Crompton Greaves / Philips.
Surface mounted LED 15W downlighter with white powder coated aluminium housing with integrated electronic driver all as specified and directed. Make: Havells Cat Part No. ENDURANEOHESURFA CEDLS15WLED857SS / Crompton Greaves / Philips.
Multipurpose surface and wall mounted mirror light, LED 10 W battern extruded alluminium housing provided for efficient heat dissiipation with polycarbonite diffuser and integrated electronic driver. Make: Havells Cat Part No. LUMILINE+BS10WLED865SPCS / Philips / Crompton Greaves.
LED bulk head fitting 10W IP-66 enviromental friendly ultra modern energy saving surface mounted decorative hexagon bulkhead backlite LED luminaire comprising of high brightness LEDs of Havells or equivalent. Make: Havells Cat Part No. HEXAFT10WLED857SSYMBOPC / Philips / Crompton Greaves.
New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK08. Make: Havells Cat Part No. ENDURASUNDOWNSL40WLED765PASYBOPC / Philips / Crompton Greaves.
Street light fitting bracket made out of GI Pipe 40 mm dia light grade or of suitable size as per requirement and suitable shape, 02 Nos of clamps made out from MS flat of size 40 mm x 3 mm with nuts and bolts (length of pipe should not less than 1.5 m) and applying single coat of alluminium paint over a coat of red primer painting complete all as specified and directed.
Taking down carefully unserviceable submain wiring any type completely & making good the disturbed surfaces complete all as directed.
Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, servicing and over oiliing, reinstalling the same as required at its original location after repairs of the building complete all as directed.
Sheet metal enclosure single pole and neutral DD’s (Double door type) when MCB’s to be used, 12 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall complete all as specified and directed.
VTPN DB 125A double door 415 V, 12 way of IP 43 protection provided with insulated vertical phase bus-bars neutral bar with shroud, earth bar, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification lables and conforms to IS-8623-1&3, IEC 61439-1&3 fixed sunk / flush to the wall / floor complete all as specified and directed.
S&F, MCCB 4P 125 A, 16 KA 415 V, 50Hz, with thermal magnetic release complete all as specified and directed.
MCB single pole and neutral, 240 volts, 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.
MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point in any type of soil / strata all as specified or indicated including testing on completion all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc., as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Heavy duty exhaust fan of size 300 mm sweep, with louvers connecting including provision of flexible cable from ceiling rose of connector to fan & including making suitable opening hole in wall with mounting arrangement and making good the disturbed surfaces with white / colour washing / distempering to match the existing wall complete all as specified and directed.
Submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable, multistranded drawn including PVC conduit medium grade 20 mm dia with all fittings and accessories fixed concealed (including chase cutting in brick / stone masonry walls for fixing conduit and plastering the external surface and matching the same with existing surface) all as specified and directed by Engineer-in-Charge for the following: - (a) 2x4.0 sq mm wiring cable and 1x4.0 sq mm as earth wire Note: 2 runs of wiring cable 1 run of earth wire & 1 run of PVC conduct shall be measured as one length.
Submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable, multistranded drawn including PVC conduit medium grade 25 mm dia with all fittings and accessories fixed concealed (including chase cutting in brick / stone masonry walls for fixing conduit and plastering the external surface and matching the same with existing surface) all as specified and directed by Engineer-in-Charge for the following: - (a) 2x6 sq mm wiring cable and 1x6 sq mm as earth wire. Note: 2 runs of wiring cable 1 run of earth wire & 1 run of PVC conduct shall be measured as one length.
Cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core on wall surface clamped with 1 mm thick saddle as required.
GI pipe light grade 50mm dia insert in PCC / brick work at entrance / exist gate column (each 2 metre lengh) for fixing of gate light fitting complete all as directed.
Rigid non-metallic PVC conduit concealed exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as directed.
Junction boxes (1 to 4 way) of dia 25 mm concealed complete all as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for laying of LT under ground cable and getting out in soft / disintegrated rock complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and lay in trenches unreinforced precast concrete cable cover class LV type 1, flat size 250 x 150 x 40 mm for cable protection all as specified and directed by Engineer-in-Charge.
Sand (stone crushed sand) in cable trenches as cushioning to cables including spreading and punning down all as per clause No. 3.21 of SSR Part-I (2009) complete all as specified and directed by Engr-in-Charge. Note: Punned thickness shall only be measured and paid.
GI tube 40mm dia light grade with all fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection including removing of old unserviceable pipe of any size all as specified. Note: Excavation and earth work where required shall be measured separately. MS clamps for fixing on wall / pole, etc are included in the unit rate.
LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply and install air conditioner inverter technology split units indoor & outdoor copper coiled complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser green gas with minimum 5 star rating and EER 3.3 of capacity 1.5 TR complete all as specified and directed.
Supply and install air conditioner inverter technology split units indoor & outdoor copper coiled complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser green gas with minimum 5 star rating and EER 3.3 of capacity 2 TR complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.
Supply, installation, commissioning of Water cooler with in-built RO+UV purification fully stainless steel, electric driven single phase having approx storage of 80 litres and nominal cooling of 40 litres per hour complete all as specified and as directed by Engineer-in-Charge.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed.
Supply & fixing GI pipe medium grade 15mm dia fixed on wall / ground / ceiling all as specified.
Supply & fixing stop cock, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes fancy type chromium plated 15 mm dia.
Pillar taps, fancy type, 15mm bore of pipe, cast copper alloy, chromium plated screwed for iron pipe complete all as specified and directed.
Making connection of G.I. distribution branch with G.I. main of 40 mm nominal bore sizes by providing and fixing tee, including cutting and threading the pipe etc. complete all as specified and directed.
sanjay m. suryawanshi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .