| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹20.4 L+₹9,290 (0.46%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹20.5 L+₹17,385 (0.86%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹21.4 L+₹1.1 L (5.40%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹23.5 L+₹3.2 L (15.7%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹43.7 L
EMD Value
₹87,480
Closing Date
6 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF STREET/SECURITY LIGHTS AND MISC WORKS AT COD INSIDE AND COD ESTATE, VRG LINE, ME LINE UNDER GE (I) KANPUR
2024_MES_660034_1
GE(I)/KAN/T-17 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹87,480
Yes
31 Aug 2024
15 Jun 2024
13 Jul 2024
15 Jun 2024
6 Jul 2024
29 Jun 2024
Amount
Taking down of existing unserviceable Street Light/Flood Light of any type/ Building Security Light any type any make from pole at any height etc any type complete after removing from existing bracket etc and re-fixing the same after necessary repair/ replacement of unserviceable Light with new fittings/component/led driver etc complete all as specified and directed. Note:- (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items. (iii) Any type of Ladder for dismantling and refixing of light from pole at any height shall be arranged by the contractor. (iii) Complaint slip book, complaint register and ladder and T & P shall be provided by the contractor (iv). Complaints of street/flood lights shall be done on daily bases and after completion the complaint slip deposited to concern JE E/M.)
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables complete all as specified and directed.
All as per item No-2 above but depth exc 1.5 mtr but not exc 3.00 mtr complete all as specified and directed.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed.
M&L for pre cast cement concrete ( 1:3:6) type C2 using 40mm graded stone aggregate for foundation filling of stays complete all as specified and directed.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for cable protection pipe upto 80 mm bore complete all as specified and as directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level complete all as specified and directed.
Disconnecting electrically and taking out old unserviceable LT UG cables any type of size 10 Sqmm to 16 Sqmm 2 core complete all as specified and directed.
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 10 sq. mm nominal cross section 2 core in service connections all as required and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No 11 above but cable of size 16 Sqmm 2 core complete all as specified and directed.
Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 4 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No-13 above but cable of size 16 Sqmm 4 core complete all as specified and directed.
All as per srl item No-13 above but cable of size 35 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No-13 above but cable of size 50 Sqmm 3.5 core complete all as specified and directed.
Material and labour for GI tubing light grade 50 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole cut to piece complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
Supply & fix in replacement cable PVC insulated flexible aluminium conductor cable of size 4 Sqmm twin core cut to pieces all as required for connection with proper thimbles, drawn in existing GI/PVC conduit pipe fixed on wal/pole, on steel pole and bracket from junction box to street light all as directed.(Rates of 20 mm PVC condiut pipe and AL/MS wire to fasten the Conduit pipe with poles are included)
S&F in replacement of highly efficient IP-66 LED street light fitting 35W with aluminium pressure die-cat housing, toughened glass in the fron the peanut lens for batwing light distribution, higher pcing between pos and maintenace free system camplete with all accessores complete all as specified and directed.
All as per item No-19 above but LED street light 60 Watt complete all as specified and directed.
All as per item No-19 above but LED street light 70 Watt complete all as specified and directed.
All as per item No-19 above but LED street light 90 Watt complete all as specified and directed.
All as per item No-19 above but LED street light 120 Watt complete all as specified and directed.
S&F in replacement of LED flood light 70 watt high efficiency IP-66 innovative with pressure die-cast aluminium housing and toughened glass in the fron with unuqe flood optics to ensure uniform distribuition and savings upto 50% as compared to conventional system all as specified and directed by Engr-in- Charge.
All as per item No-24 above but LED flood light 120 Watt complete all as specified and directed.
All as per item No-24 above but LED flood light 170 Watt complete all as specified and directed.
S & F in replacement of street light bracket made out of GI tubing, light grade, 25/32/40mm bore, 1000mm long, bent to shape at 120 degree, fixed on pole by providing two sets of MS clamp made up of flat iron 40 x 6mm including bolts, nuts and washer of suitable size including painting the bracket & clamp with two coats of aluminium paint over a coat of primer complete all as specified and directed.
Disconnecting, dismantling and taking out old steel tubular pole any size/ length and making good all disturbed surface to match with existing specifications complete all as specified and directed.
Supply, erecting and installation of steel tubular, swaged, pole of overall length 9 meter having maximum tensile strength 42 Kgf/mm2 of type 410 SP-31 conforming to IS-2713-1980, single swan neck made out of 50 mm dia MS pipe 1.5 mtr long to be jointed on top of LT pole incl fabrication work for fixing street light. A through hole of 14 mm dia shall be provided at height of 2.5 mtr from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings including earth work complete with cast iron base plate, having suitable dia of hole through the pole with nuts & bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 meter length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 metre length 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 meter length, 3.65 mm wall thickness of pole wall, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be deemed to be included in the unit rate.
Supply, fixing, testing and comissioning of automatic street light switch of capacity 8 kW in single phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure Make : Hensel confirming to IP66 enclosure box ,rust proof, electric shock proof, termite proof , including mounting arrangement with suitable size of FI clamps 02 Nos with complete acessories as under including taking down old street light switch complete all as specified and directed. (i) Contactor rating (AC3) single phase, 50-63 Amp : [Make : BCH/L&T/Schneider] (ii) MCB 63Amps (SP),10 kA, 240 volts: [Make : Schinder/ Legrand/ L&T] (iii) NATURESWITCH-01 [Make: HEALER (Model No. SWADEEP - 02EC8kW1P) or equivalent to Schenider/Hensal]
S&F in repair weatherproof junction box of size not less than 200x140x95 mm outdoor type made out of thermo polycarbonat to accmmodated 02 Nos aluminium bus bar of size 25x6 mm rating 100 Amps and MCB SP 16 Amps IP-55 with hinged door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/steel parts complete incl taking down old one all as specified and as directed.
Disconnecting electrically, dismantling and taking out existing street light junction box any size/type from PCC/steel pole and refixing on same pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc after repair including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/steel parts and making electrical connection complete all as specified and as directed.
Demolition & dismantling of cement concrete in ground floors and paving for making trench for laying XLPE cable etc including removing the debris from the site complete all as specified and directed.
Material & labour for plain cement concrete 1:3:6, type C1, using 20 mm grade stone aggregate for filling the pavings / trenches / foot path etc complete all as specified and directed.
S & F in replacement of LED solar street light fitting 20 Watt including galvanised steel pole in built lithium ion battery, solar panel, charge controller with dusk down senso complete with fitting & fixtures with duly painted as per directed by Engr-in charge complete all as specified and as directed.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to galvanised earth lead wire 4.0mm dia by means of nuts,bolt,washers etc.of copper / brass connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,GI water pipe with 20mm dia.funnel &wire mesh PCC pit with CI cover and frame etc all as specified and directed. Note:- All the joints shall be made with welding to get proper conductivity.
Supply and fix in replacement Gate light fitting LED type 20 W with CCT not less than 5700K/3000K/4000K ,and IP 65 Protection ,230V recessed mounting mirror opticluminare complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete including wire and making connection complete with pole all as specified and directed.
M&L for MCB single pole 240 volts 5 to 32 amps, with rupturing capacity 10 kA, using thimbles of required size complete all as specified and directed.
M/S DARSHAN ENGINEERING WORKS
M/S PASHUPATI TRADERS
S B ENTERPRISES
Kumar Electricals
santosh electronics
V.V CONSTRUCTIONS
SAKSHAM SUPPLIERS BUILDERS
PAWAN COOL CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .