| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.9 L+₹1.4 L (30.5%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.7 L+₹2.1 L (47.6%)Rejected-Finance KHUKURANI MANDAL | MEDINIPUR EAST | WEST BENGAL | 721130 | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | KAUSHIK ENTERPRISE L2 | KAR ENTERPRISE L3 | SINHA ELECTRIC L1 |
|---|---|---|---|---|---|---|
| 1.00Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter-connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) [Temp PWD(El) [1] ] [ Upto 3 Days] | ||||||
| 1.01 | c) 415V, 200 amp TPN switch HRC fuse type [Temp PWD(El) [f)] ] [ Upto 3 Days] | 5 | Each | 820 ₹4,100 | 501 ₹2,505 | 452 ₹2,260 Lowest |
| 2.00Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter-connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) [Temp PWD(El) [2] ] [ Upto 3 Days] | ||||||
| 2.01 | 415V, Upto 8 Way 160 amp, VTPNDB With 100/160 amp MCCB As Incoming 8 No.63 amp FPMCB as Outgoing [Temp PWD(El) [c)] ] [ Upto 3 Days] | 5 | Each | 1,400 ₹7,000 | 920 ₹4,600 | 890 ₹4,450 Lowest |
| 2.02 | 240V, 2+12 Way SPNBDB With 6-32 amp SPMCB as Outgoing & 40/63 amp DPMCB as Incoming. [Temp PWD(El) [a)] ] [ Upto 3 Days] | 10 | Each | 260 ₹2,600 | 196 ₹1,960 | 186 ₹1,860 Lowest |
| 2.03 | 415V, Upto 6 Way TPNBDB With 1 No. 63 amp FPMCB as Incoming & 15 No. 6-32 amp SPMCB as Outgoing [Temp PWD(El) [b)] ] [ Upto 2 Days] | 10 | Each | 348 ₹3,480 | 303 ₹3,030 | 260 ₹2,600 Lowest |
| 3.00Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same and mending good the damages. [Temp PWD(El) [5] ] [ Upto 3 Days] | ||||||
| 3.01 | 4 Core 95 Sq. mm PVC/XLPE armourured cable per meter [Temp PWD(El) [d)] ] [ Upto 3 Days] | 800 | mtr | 54 ₹43,200 | 82 ₹65,600 | 30 ₹24,000 Lowest |
| 3.02 | 4 Core 25 Sq. mm PVC/XLPE armourured cable per meter [Temp PWD(El) [f)] ] [ Upto 3 Days] | 300 | mtr | 45 ₹13,500 | 56 ₹16,800 | 26 ₹7,800 Lowest |
| 3.03 | 2 Core 16 Sq. mm PVC/XLPE armourured cable per meter [Temp PWD(El) [h)] ] [ Upto 3 Days] | 450 | mtr | 28 ₹12,600 | 40 ₹18,000 | 20 ₹9,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹9,500
Closing Date
15 Jul 2026, 1:00 pmClosed
AE/KRESD/PWDte
Office of The Assistant Engineer, Kolkata Lok Bhavan Electrical Sub Division, P.W.Dte., 2 Larkin Lane, Kolkata-700062
Temporary Electrical Installation and security lighting in connection with celebration of various programmes/state foundation days and VVIP visits/night stays at Lok Bhavan, Kolkata.
2026_WBPWD_5016235_1
WBPWD/AE-KRESD/NIQ-03/2026-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
45 days
Lok Bhavan Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,500
1 Oct 2026
2 Jul 2026
17 Jul 2026
3 Jul 2026
15 Jul 2026
3 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter-connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) [Temp PWD(El) [1] ] [ Upto 3 Days] | |||||
| 1.01 | c) 415V, 200 amp TPN switch HRC fuse type [Temp PWD(El) [f)] ] [ Upto 3 Days] | 5 | Each | - | - |
| 2Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter-connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials) [Temp PWD(El) [2] ] [ Upto 3 Days] | |||||
| 2.01 | 415V, Upto 8 Way 160 amp, VTPNDB With 100/160 amp MCCB As Incoming 8 No.63 amp FPMCB as Outgoing [Temp PWD(El) [c)] ] [ Upto 3 Days] | 5 | Each | - | - |
| 2.02 | 240V, 2+12 Way SPNBDB With 6-32 amp SPMCB as Outgoing & 40/63 amp DPMCB as Incoming. [Temp PWD(El) [a)] ] [ Upto 3 Days] | 10 | Each | - | - |
| 2.03 | 415V, Upto 6 Way TPNBDB With 1 No. 63 amp FPMCB as Incoming & 15 No. 6-32 amp SPMCB as Outgoing [Temp PWD(El) [b)] ] [ Upto 2 Days] | 10 | Each | - | - |
| 3Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same and mending good the damages. [Temp PWD(El) [5] ] [ Upto 3 Days] | |||||
| 3.01 | 4 Core 95 Sq. mm PVC/XLPE armourured cable per meter [Temp PWD(El) [d)] ] [ Upto 3 Days] | 800 | mtr | - | - |
| 3.02 | 4 Core 25 Sq. mm PVC/XLPE armourured cable per meter [Temp PWD(El) [f)] ] [ Upto 3 Days] | 300 | mtr | - | - |
| 3.03 | 2 Core 16 Sq. mm PVC/XLPE armourured cable per meter [Temp PWD(El) [h)] ] [ Upto 3 Days] | 450 | mtr | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_5085533.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .